Skip to main content
Top
Published in: Clinical Oral Investigations 9/2013

01-12-2013 | Original Article

The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems

Authors: Petya K. Brawek, Stefan Wolfart, Lutz Endres, Armin Kirsten, Sven Reich

Published in: Clinical Oral Investigations | Issue 9/2013

Login to get access

Abstract

Objectives

The purpose of the study was to compare the accuracy of crowns exclusively fabricated by the digital workflow of two systems. The null hypothesis stated was: Both systems do not differ with respect to marginal and internal accuracy.

Materials and methods

In 14 patients, 13 molars and 1 premolar were prepared. Each preparation was scanned intraorally with two different digital impression systems, Lava COS and Cerec AC. On the basis of these data, Lava DVS crowns [DVS] and Vita Rapid Layering Technique crowns [RLT] were fabricated, respectively. Both systems contained of a zirconia framework and a digitally fabricated silicate ceramic veneering. The marginal and internal fit of the crowns was documented by a replica technique. The replicas were examined under microscope with a magnification of ×200. The Wilcoxon signed rank test was applied in order to test if the values of the two systems showed significant differences at p ≤ 0.05.

Results

The results were as follows in micrometers (±standard deviation): at the marginal gap, 51 (±38) for [DVS] and 83 (±51) for [RLT]; mid-axial, 130 (±56) for [DVS] and 128 (±66) for [RLT]; axio-occlusal, 178 (±55) for [DVS] and 230 (±71) for [RLT]; and centro-occlusal, 181 (±41) for [DVS] and 297 (±76) for [RLT]. According to the Wilcoxon signed rank test, the results differed significantly at the marginal, axio-occlusal, and centro-occlusal gaps.

Conclusions

The null hypothesis had to be rejected.

Clinical relevance

The exclusively digital workflow on the basis of intraoral digital impressions delivered clinically satisfying results for single crowns with both systems.
Literature
1.
go back to reference Jager K, Vogtlin C (2012) [Digital workflow with the Lava Chairside Oral Scanner C.O.S. and Lava technique]. Schweiz Monatsschr Zahnmed 122 (4):307–324. doi:smfz-2012-04-01 Jager K, Vogtlin C (2012) [Digital workflow with the Lava Chairside Oral Scanner C.O.S. and Lava technique]. Schweiz Monatsschr Zahnmed 122 (4):307–324. doi:smfz-2012-04-01
2.
go back to reference Fasbinder DJ (2010) Digital dentistry: innovation for restorative treatment. Compend Contin Educ Dent 31(Spec. No. 4):2–11 (quiz 12) Fasbinder DJ (2010) Digital dentistry: innovation for restorative treatment. Compend Contin Educ Dent 31(Spec. No. 4):2–11 (quiz 12)
3.
go back to reference Craddock MR, Windhorn RJ (2011) Is the US Army Dental Corps ready for the digital impression? US Army Med Dep J Jan–Mar:38–41 Craddock MR, Windhorn RJ (2011) Is the US Army Dental Corps ready for the digital impression? US Army Med Dep J Jan–Mar:38–41
4.
go back to reference Mehl A, Hickel R (1999) Current state of development and perspectives of machine-based production methods for dental restorations. Int J Comput Dent 2(1):9–35PubMed Mehl A, Hickel R (1999) Current state of development and perspectives of machine-based production methods for dental restorations. Int J Comput Dent 2(1):9–35PubMed
5.
go back to reference Gozdowski S, Reich S (2009) A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress. Int J Comput Dent 12(3):279–289PubMed Gozdowski S, Reich S (2009) A comparison of the fabrication times of all-ceramic partial crowns: Cerec 3D vs IPS Empress. Int J Comput Dent 12(3):279–289PubMed
6.
go back to reference Kurbad A (2011) Digital veneering—manufacturing computer-generated veneers with the CAD-on technique. Int J Comput Dent 14(3):255–271 Kurbad A (2011) Digital veneering—manufacturing computer-generated veneers with the CAD-on technique. Int J Comput Dent 14(3):255–271
7.
go back to reference Wiedhahn K (2011) The impression-free Cerec multilayer bridge with the CAD-on method. Int J Comput Dent 14(1):33–45 Wiedhahn K (2011) The impression-free Cerec multilayer bridge with the CAD-on method. Int J Comput Dent 14(1):33–45
8.
go back to reference Holmes JR, Sulik WD, Holland GA, Bayne SC (1992) Marginal fit of castable ceramic crowns. J Prosthet Dent 67(5):594–599PubMedCrossRef Holmes JR, Sulik WD, Holland GA, Bayne SC (1992) Marginal fit of castable ceramic crowns. J Prosthet Dent 67(5):594–599PubMedCrossRef
9.
go back to reference Schwickerath H (1979) Marginal cleft and solubility. Dtsch Zahnarztl Z 34(9):664–669PubMed Schwickerath H (1979) Marginal cleft and solubility. Dtsch Zahnarztl Z 34(9):664–669PubMed
10.
go back to reference McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131(3):107–111PubMedCrossRef McLean JW, von Fraunhofer JA (1971) The estimation of cement film thickness by an in vivo technique. Br Dent J 131(3):107–111PubMedCrossRef
11.
go back to reference Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20(4):383–388PubMed Sailer I, Feher A, Filser F, Gauckler LJ, Luthy H, Hammerle CH (2007) Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont 20(4):383–388PubMed
12.
go back to reference Pfeiffer J (1998) Dental CAD/CAM technologies: the optical impression (I). Int J Comput Dent 1(1):29–33PubMed Pfeiffer J (1998) Dental CAD/CAM technologies: the optical impression (I). Int J Comput Dent 1(1):29–33PubMed
13.
go back to reference Pfeiffer J (1999) Dental CAD/CAM technologies: the optical impression (II). Int J Comput Dent 2(1):65–72PubMed Pfeiffer J (1999) Dental CAD/CAM technologies: the optical impression (II). Int J Comput Dent 2(1):65–72PubMed
14.
go back to reference Mehl A, Ender A, Mormann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28PubMed Mehl A, Ender A, Mormann W, Attin T (2009) Accuracy testing of a new intraoral 3D camera. Int J Comput Dent 12(1):11–28PubMed
15.
go back to reference Rohaly J (2009) The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people. Interview by Laslo Faith. Int J Comput Dent 12(2):165–169PubMed Rohaly J (2009) The development of the Lava chairside oral scanner C.O.S. technology—masterstroke of a legion of talented and committed people. Interview by Laslo Faith. Int J Comput Dent 12(2):165–169PubMed
16.
go back to reference Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21PubMed Ender A, Mehl A (2011) Full arch scans: conventional versus digital impressions—an in-vitro study. Int J Comput Dent 14(1):11–21PubMed
17.
go back to reference Kohorst P, Junghanns J, Dittmer MP, Borchers L, Stiesch M (2011) Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy. Clin Oral Invest 15(4):527–536. doi:10.1007/S00784-010-0415-9 CrossRef Kohorst P, Junghanns J, Dittmer MP, Borchers L, Stiesch M (2011) Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy. Clin Oral Invest 15(4):527–536. doi:10.​1007/​S00784-010-0415-9 CrossRef
18.
go back to reference Fransson B, Oilo G, Gjeitanger R (1985) The fit of metal–ceramic crowns, a clinical study. Dent Mater 1(5):197–199PubMedCrossRef Fransson B, Oilo G, Gjeitanger R (1985) The fit of metal–ceramic crowns, a clinical study. Dent Mater 1(5):197–199PubMedCrossRef
20.
go back to reference Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Invest 15(4):521–526. doi:10.1007/S00784-010-0414-X CrossRef Reich S, Uhlen S, Gozdowski S, Lohbauer U (2011) Measurement of cement thickness under lithium disilicate crowns using an impression material technique. Clin Oral Invest 15(4):521–526. doi:10.​1007/​S00784-010-0414-X CrossRef
21.
go back to reference Reich S, Kappe K, Teschner H, Schmitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116(6):579–584PubMedCrossRef Reich S, Kappe K, Teschner H, Schmitt J (2008) Clinical fit of four-unit zirconia posterior fixed dental prostheses. Eur J Oral Sci 116(6):579–584PubMedCrossRef
22.
go back to reference Boening KW, Wolf BH, Schmidt AE, Kastner K, Walter MH (2000) Clinical fit of Procera AllCeram crowns. J Prosthet Dent 84(4):419–424PubMedCrossRef Boening KW, Wolf BH, Schmidt AE, Kastner K, Walter MH (2000) Clinical fit of Procera AllCeram crowns. J Prosthet Dent 84(4):419–424PubMedCrossRef
23.
go back to reference Molin M, Karlsson S (1993) The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study. Acta Odontol Scand 51(4):201–206PubMedCrossRef Molin M, Karlsson S (1993) The fit of gold inlays and three ceramic inlay systems. A clinical and in vitro study. Acta Odontol Scand 51(4):201–206PubMedCrossRef
24.
go back to reference Holst S, Karl M, Wichmann M, Matta RE (2011) A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int 42(8):651–657PubMed Holst S, Karl M, Wichmann M, Matta RE (2011) A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int 42(8):651–657PubMed
25.
go back to reference Luthardt RG, Bornemann G, Lemelson S, Walter MH, Huls A (2004) An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont 17(6):680–685PubMed Luthardt RG, Bornemann G, Lemelson S, Walter MH, Huls A (2004) An innovative method for evaluation of the 3-D internal fit of CAD/CAM crowns fabricated after direct optical versus indirect laser scan digitizing. Int J Prosthodont 17(6):680–685PubMed
27.
28.
go back to reference Scotti R, Cardelli P, Baldissara P, Monaco C (2011) Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling. J Dent. doi:10.1016/j.jdent.2011.10.005 Scotti R, Cardelli P, Baldissara P, Monaco C (2011) Clinical fitting of CAD/CAM zirconia single crowns generated from digital intraoral impressions based on active wavefront sampling. J Dent. doi:10.​1016/​j.​jdent.​2011.​10.​005
29.
go back to reference Tuntiprawon M, Wilson PR (1995) The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J 40(1):17–21PubMedCrossRef Tuntiprawon M, Wilson PR (1995) The effect of cement thickness on the fracture strength of all-ceramic crowns. Aust Dent J 40(1):17–21PubMedCrossRef
Metadata
Title
The clinical accuracy of single crowns exclusively fabricated by digital workflow—the comparison of two systems
Authors
Petya K. Brawek
Stefan Wolfart
Lutz Endres
Armin Kirsten
Sven Reich
Publication date
01-12-2013
Publisher
Springer Berlin Heidelberg
Published in
Clinical Oral Investigations / Issue 9/2013
Print ISSN: 1432-6981
Electronic ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-013-0923-5

Other articles of this Issue 9/2013

Clinical Oral Investigations 9/2013 Go to the issue