Abstract

Objectives

To assess the accuracy of reduced-dose, low-mA chest CT (RD-CT) reconstructed with model-based iterative reconstruction (MBIR) in detecting usual early complications following pulmonary transplantation, as compared to standard-dose chest CT (SD-CT) reconstructed with adaptative statistical iterative reconstruction (ASIR).

Methods

Our institutional review board approved this prospective study and patients provided written informed consent. Two thoracic radiologists independently evaluated 47 examinations performed routinely in 20 patients during 6 months following lung transplantation for the detection and/or evolution of usual pleuropulmonary complications and for subjective image quality. Each examination consisted of successive acquisition of unenhanced SD-CT (100–120 kV, noise index 45, ASIR) and RD-CT (100 kV, 16–24mAs/slice, MBIR).

Results

Mean CTDIvol was 4.12 ± 0.88 and 0.65 ± 0.09 mGy for SD-CT and RD-CT, respectively. Complications were found in 40/47 (85 %) examinations. Sensitivity and negative predictive value of RD-CT were 92–100 % for the detection of pneumonia, fungal infection, pleural effusion, pneumothorax, and bronchial dehiscence or stenosis, as compared to SD-CT. Image quality of RD-CT was graded good for 81 % of examinations.

Conclusions

MBIR-RD-CT is accurate, as compared to SD-CT, for delineating most usual pleuropulmonary complications during the 6 months following pulmonary transplantation and might be used routinely for the early monitoring of pulmonary allografts.

Key Points

Early chest complications are frequent following a pulmonary transplantation
CT has a key role for their detection and follow-up
Low-mAMBIR CT is accurate for monitoring most lung allograft early pleuropulmonary complications
MBIR chest CT allows a six-fold dose reduction compared to standard CT
Literature
1.
go back to reference Yusen RD, Christie JD, Edwards LB et al (2013) The Registry of the International Society for Heart and Lung Transplantation: Thirtieth Adult Lung and Heart-Lung Transplant Report—2013; Focus Theme:Age. J Heart Lung Transplant 32:965–978CrossRefPubMed Yusen RD, Christie JD, Edwards LB et al (2013) The Registry of the International Society for Heart and Lung Transplantation: Thirtieth Adult Lung and Heart-Lung Transplant Report—2013; Focus Theme:Age. J Heart Lung Transplant 32:965–978CrossRefPubMed
2.
go back to reference Krishnam MS, Suh RD, Tomasian A et al (2007) Postoperative complications of lung transplantation: radiologic findings among a time continuum. Radiographics 27:957–974CrossRefPubMed Krishnam MS, Suh RD, Tomasian A et al (2007) Postoperative complications of lung transplantation: radiologic findings among a time continuum. Radiographics 27:957–974CrossRefPubMed
3.
go back to reference Brenner DJ, Hall EJ (2007) Computed Tomography — An Increasing Source of Radiation Exposure. N Engl J Med 357:2277–2284CrossRefPubMed Brenner DJ, Hall EJ (2007) Computed Tomography — An Increasing Source of Radiation Exposure. N Engl J Med 357:2277–2284CrossRefPubMed
4.
go back to reference Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771CrossRefPubMed Hara AK, Paden RG, Silva AC, Kujak JL, Lawder HJ, Pavlicek W (2009) Iterative reconstruction technique for reducing body radiation dose at CT: feasibility study. AJR Am J Roentgenol 193:764–771CrossRefPubMed
5.
go back to reference Thibault JB, Sauer KD, Bouman CA, Hsieh J (2007) A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 34:4526–4544CrossRefPubMed Thibault JB, Sauer KD, Bouman CA, Hsieh J (2007) A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys 34:4526–4544CrossRefPubMed
6.
go back to reference Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X (2013) Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination :preliminary observations. Eur Radiol 23:360–366CrossRefPubMed Neroladaki A, Botsikas D, Boudabbous S, Becker CD, Montet X (2013) Computed tomography of the chest with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination :preliminary observations. Eur Radiol 23:360–366CrossRefPubMed
7.
go back to reference Miéville FA, Berteloot L, Grandjean A et al (2013) Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis. Pediatr Radiol 43:558–567CrossRefPubMed Miéville FA, Berteloot L, Grandjean A et al (2013) Model-based iterative reconstruction in pediatric chest CT: assessment of image quality in a prospective study of children with cystic fibrosis. Pediatr Radiol 43:558–567CrossRefPubMed
8.
go back to reference Vardhanabhuti V, Loader RJ, Mitchell GR, Riordan RD, Roobottom CA (2013) Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. AJR Am J Roentgenol 200:545–552CrossRefPubMed Vardhanabhuti V, Loader RJ, Mitchell GR, Riordan RD, Roobottom CA (2013) Image quality assessment of standard- and low-dose chest CT using filtered back projection, adaptive statistical iterative reconstruction, and novel model-based iterative reconstruction algorithms. AJR Am J Roentgenol 200:545–552CrossRefPubMed
9.
go back to reference Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212 Katsura M, Matsuda I, Akahane M et al (2013) Model-based iterative reconstruction technique for ultralow-dose chest CT: comparison of pulmonary nodule detectability with the adaptive statistical iterative reconstruction technique. Investig Radiol 48:206–212
10.
go back to reference Yamada Y, Jinzaki M, Tanami Y et al (2012) Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung. A pilot study. Investig Radiol 47:482–489CrossRef Yamada Y, Jinzaki M, Tanami Y et al (2012) Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung. A pilot study. Investig Radiol 47:482–489CrossRef
11.
go back to reference Ichikawa Y, Kitagawa K, Nagasawa N, Murashima S, Sakuma H (2013) CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction. BMC Med Imaging 13:27CrossRefPubMedPubMedCentral Ichikawa Y, Kitagawa K, Nagasawa N, Murashima S, Sakuma H (2013) CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction. BMC Med Imaging 13:27CrossRefPubMedPubMedCentral
12.
go back to reference Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic medicine: a catalog. Radiology 248:254–263CrossRefPubMed Mettler FA Jr, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic medicine: a catalog. Radiology 248:254–263CrossRefPubMed
13.
go back to reference Pontana F, Pagniez J, Flohr T et al (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol 21:627–635CrossRefPubMed Pontana F, Pagniez J, Flohr T et al (2011) Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol 21:627–635CrossRefPubMed
14.
go back to reference American Association of Physicists in Medicine (2011) Size-Specific dose estimates (SSDE) in pediatric and adult body CT examinations. Task Group 204, College Park American Association of Physicists in Medicine (2011) Size-Specific dose estimates (SSDE) in pediatric and adult body CT examinations. Task Group 204, College Park
15.
go back to reference Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed Landis JR, Koch GG (1977) The measurement of observer agreement for categorical data. Biometrics 33:159–174CrossRefPubMed
16.
go back to reference Ng YL, Paul N, Patsios D et al (2009) Imaging of lung transplantation: review. AJR Am J Roentgenol 192:S1–S13CrossRefPubMed Ng YL, Paul N, Patsios D et al (2009) Imaging of lung transplantation: review. AJR Am J Roentgenol 192:S1–S13CrossRefPubMed
17.
go back to reference Gotway MB, Dawn SK, Sellami D, Golden JA, Reddy GP, Keith FM et al (2001) Acute rejection following lung transplantation:limitations in accuracy of thin-section CT for diagnosis. Radiology 221:207–212CrossRefPubMed Gotway MB, Dawn SK, Sellami D, Golden JA, Reddy GP, Keith FM et al (2001) Acute rejection following lung transplantation:limitations in accuracy of thin-section CT for diagnosis. Radiology 221:207–212CrossRefPubMed
18.
go back to reference Kotloff RM, Ahya VN, Crawford SW (2004) Pulmonary complications of solid and hematopoietic stem cell transplantation. Am J Respir Crit Care Med 170:22–48CrossRefPubMed Kotloff RM, Ahya VN, Crawford SW (2004) Pulmonary complications of solid and hematopoietic stem cell transplantation. Am J Respir Crit Care Med 170:22–48CrossRefPubMed
19.
go back to reference Neofytos D, Fishman JA, Horn D, Anaissie E, Chang CH, Olyaei A et al (2010) Epidemiology and outcome of invasive fungal infections in solid organ transplant recipients. Transpl Infect Dis 12:220–229CrossRefPubMed Neofytos D, Fishman JA, Horn D, Anaissie E, Chang CH, Olyaei A et al (2010) Epidemiology and outcome of invasive fungal infections in solid organ transplant recipients. Transpl Infect Dis 12:220–229CrossRefPubMed
20.
go back to reference Collins J, Müller NL, Kazerooni EA, Paciocco G (2000) CT findings of pneumonia after lung transplantation. AJR Am J Roentgenol 175:811–818CrossRefPubMed Collins J, Müller NL, Kazerooni EA, Paciocco G (2000) CT findings of pneumonia after lung transplantation. AJR Am J Roentgenol 175:811–818CrossRefPubMed
21.
go back to reference Ko JP, Shepard JA, Sproule MW, Trotman-Dickenson B, Drucker EA, Ginns LC et al (2000) CT manifestations of respiratory syncytial virus infection in lung transplant recipients. J Comput Assist Tomogr 24:235–241CrossRefPubMed Ko JP, Shepard JA, Sproule MW, Trotman-Dickenson B, Drucker EA, Ginns LC et al (2000) CT manifestations of respiratory syncytial virus infection in lung transplant recipients. J Comput Assist Tomogr 24:235–241CrossRefPubMed
22.
go back to reference Shiley KT, Van Deerlin VM, Miller WT Jr (2010) Chest CT features of community-acquired respiratory viral infections in adult inpatients with lower respiratory tract infections. J Thorac Imaging 25:68–75CrossRefPubMed Shiley KT, Van Deerlin VM, Miller WT Jr (2010) Chest CT features of community-acquired respiratory viral infections in adult inpatients with lower respiratory tract infections. J Thorac Imaging 25:68–75CrossRefPubMed
23.
go back to reference Semenkovich JW, Glazer HS, Anderson DC, Arcidi JM Jr, Cooper JD, Patterson GA (1995) Bronchial dehiscence in lung transplantation: CT evaluation. Radiology 194:205–208CrossRefPubMed Semenkovich JW, Glazer HS, Anderson DC, Arcidi JM Jr, Cooper JD, Patterson GA (1995) Bronchial dehiscence in lung transplantation: CT evaluation. Radiology 194:205–208CrossRefPubMed
24.
go back to reference Montet X, Hachulla AL, Neroladaki A et al (2014) Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial. Eur Radiol. doi:10.1007/s00330-014-3563-5 Montet X, Hachulla AL, Neroladaki A et al (2014) Image quality of low mA CT pulmonary angiography reconstructed with model based iterative reconstruction versus standard CT pulmonary angiography reconstructed with filtered back projection: an equivalency trial. Eur Radiol. doi:10.​1007/​s00330-014-3563-5
Metadata
Title
Diagnostic accuracy of low-mA chest CT reconstructed with Model Based Iterative Reconstruction in the detection of early pleuro-pulmonary complications following a lung transplantation
Authors
Marie-Pierre Debray
Gaëlle Dauriat
Antoine Khalil
Sebastien Leygnac
Sarah Tubiana
Albane Grandjean
Elisabeth Schouman-Claeys
Jean-Pierre Laissy
Phalla Ou
Publication date
01-09-2016
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 9/2016
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-015-4126-0

Other articles of this Issue 9/2016

European Radiology 9/2016 Go to the issue