Published in: BMC Medical Imaging 1/2013

Open Access 01-12-2013 | Research article

CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction

Authors: Yasutaka Ichikawa, Kakuya Kitagawa, Naoki Nagasawa, Shuichi Murashima, Hajime Sakuma

Published in: BMC Medical Imaging | Issue 1/2013

Login to get access

Abstract

Background

The recently developed model-based iterative reconstruction (MBIR) enables significant reduction of image noise and artifacts, compared with adaptive statistical iterative reconstruction (ASIR) and filtered back projection (FBP). The purpose of this study was to evaluate lesion detectability of low-dose chest computed tomography (CT) with MBIR in comparison with ASIR and FBP.

Methods

Chest CT was acquired with 64-slice CT (Discovery CT750HD) with standard-dose (5.7 ± 2.3 mSv) and low-dose (1.6 ± 0.8 mSv) conditions in 55 patients (aged 72 ± 7 years) who were suspected of lung disease on chest radiograms. Low-dose CT images were reconstructed with MBIR, ASIR 50% and FBP, and standard-dose CT images were reconstructed with FBP, using a reconstructed slice thickness of 0.625 mm. Two observers evaluated the image quality of abnormal lung and mediastinal structures on a 5-point scale (Score 5 = excellent and score 1 = non-diagnostic). The objective image noise was also measured as the standard deviation of CT intensity in the descending aorta.

Results

The image quality score of enlarged mediastinal lymph nodes on low-dose MBIR CT (4.7 ± 0.5) was significantly improved in comparison with low-dose FBP and ASIR CT (3.0 ± 0.5, p = 0.004; 4.0 ± 0.5, p = 0.02, respectively), and was nearly identical to the score of standard-dose FBP image (4.8 ± 0.4, p = 0.66). Concerning decreased lung attenuation (bulla, emphysema, or cyst), the image quality score on low-dose MBIR CT (4.9 ± 0.2) was slightly better compared to low-dose FBP and ASIR CT (4.5 ± 0.6, p = 0.01; 4.6 ± 0.5, p = 0.01, respectively). There were no significant differences in image quality scores of visualization of consolidation or mass, ground-glass attenuation, or reticular opacity among low- and standard-dose CT series. Image noise with low-dose MBIR CT (11.6 ± 1.0 Hounsfield units (HU)) were significantly lower than with low-dose ASIR (21.1 ± 2.6 HU, p < 0.0005), low-dose FBP CT (30.9 ± 3.9 HU, p < 0.0005), and standard-dose FBP CT (16.6 ± 2.3 HU, p < 0.0005).

Conclusion

MBIR shows greater potential than ASIR for providing diagnostically acceptable low-dose CT without compromising image quality. With radiation dose reduction of >70%, MBIR can provide equivalent lesion detectability of standard-dose FBP CT.
Appendix
Available only for authorised users
Literature
1.
go back to reference Brenner DJ, Hall EJ: Computed tomography: an increasing source of radiation exposure. N Engl J Med. 2007, 357: 2277-2284. 10.1056/NEJMra072149.CrossRefPubMed Brenner DJ, Hall EJ: Computed tomography: an increasing source of radiation exposure. N Engl J Med. 2007, 357: 2277-2284. 10.1056/NEJMra072149.CrossRefPubMed
2.
go back to reference Nelson RC, Feuerlein S, Boll DT: New iterative reconstruction techniques for cardiovascular computed tomography: how do they work, and what are the advantages and disadvantages?. J Cardiovac Comput Tomgr. 2011, 5: 286-292. 10.1016/j.jcct.2011.07.001.CrossRef Nelson RC, Feuerlein S, Boll DT: New iterative reconstruction techniques for cardiovascular computed tomography: how do they work, and what are the advantages and disadvantages?. J Cardiovac Comput Tomgr. 2011, 5: 286-292. 10.1016/j.jcct.2011.07.001.CrossRef
3.
go back to reference Prakash P, Kalra MK, Ackman JB, Digmarthy SR, Hsieh J, Do S, et al: Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology. 2010, 256: 261-269. 10.1148/radiol.10091487.CrossRefPubMed Prakash P, Kalra MK, Ackman JB, Digmarthy SR, Hsieh J, Do S, et al: Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology. 2010, 256: 261-269. 10.1148/radiol.10091487.CrossRefPubMed
4.
go back to reference Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, et al: Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm – initial clinical experience. Radiology. 2010, 254: 145-153. 10.1148/radiol.09090094.CrossRefPubMed Marin D, Nelson RC, Schindera ST, Richard S, Youngblood RS, Yoshizumi TT, et al: Low-tube-voltage, high-tube-current multidetector abdominal CT: improved image quality and decreased radiation dose with adaptive statistical iterative reconstruction algorithm – initial clinical experience. Radiology. 2010, 254: 145-153. 10.1148/radiol.09090094.CrossRefPubMed
5.
go back to reference Leipsic J, Nguyen G, Brown J, Sin D, Mayo JR: A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction. AJR Am J Roentgenol. 2010, 195: 1095-1099. 10.2214/AJR.09.4050.CrossRefPubMed Leipsic J, Nguyen G, Brown J, Sin D, Mayo JR: A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction. AJR Am J Roentgenol. 2010, 195: 1095-1099. 10.2214/AJR.09.4050.CrossRefPubMed
6.
go back to reference Singh S, Kalra MK, Gilman MD, Hseigh J, Pien HH, Digmarthy SR, et al: Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011, 259: 565-573. 10.1148/radiol.11101450.CrossRefPubMed Singh S, Kalra MK, Gilman MD, Hseigh J, Pien HH, Digmarthy SR, et al: Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology. 2011, 259: 565-573. 10.1148/radiol.11101450.CrossRefPubMed
7.
go back to reference Leipsic J, Labountry TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP: Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol. 2010, 195: 649-654. 10.2214/AJR.10.4285.CrossRefPubMed Leipsic J, Labountry TM, Heilbron B, Min JK, Mancini GB, Lin FY, Taylor C, Dunning A, Earls JP: Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol. 2010, 195: 649-654. 10.2214/AJR.10.4285.CrossRefPubMed
8.
go back to reference Sagara Y, Hara A, Pavlicek W, Silva AC, Paden RG, Wu Q: Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol. 2010, 195: 713-719. 10.2214/AJR.09.2989.CrossRefPubMed Sagara Y, Hara A, Pavlicek W, Silva AC, Paden RG, Wu Q: Abdominal CT: comparison of low-dose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol. 2010, 195: 713-719. 10.2214/AJR.09.2989.CrossRefPubMed
9.
go back to reference Prakash P, Kalra MK, Kambadakone AK, Pien H, Hsieh J, Blake MA, Sahani DV: Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol. 2010, 45: 202-210. 10.1097/RLI.ob013e3181dzfeec.CrossRefPubMed Prakash P, Kalra MK, Kambadakone AK, Pien H, Hsieh J, Blake MA, Sahani DV: Reducing abdominal CT radiation dose with adaptive statistical iterative reconstruction technique. Invest Radiol. 2010, 45: 202-210. 10.1097/RLI.ob013e3181dzfeec.CrossRefPubMed
10.
go back to reference Thibault JB, Sauer KD, Bouman CA, Hsieh J: A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007, 34: 4526-4544. 10.1118/1.2789499.CrossRefPubMed Thibault JB, Sauer KD, Bouman CA, Hsieh J: A three-dimensional statistical approach to improved image quality for multislice helical CT. Med Phys. 2007, 34: 4526-4544. 10.1118/1.2789499.CrossRefPubMed
11.
go back to reference Yamada Y, Jinzaki M, Tanami Y, et al: Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung. A pilot study. Invest Radiol. 2012, 47: 482-489. 10.1097/RLI.0b013e3182562a89.CrossRefPubMed Yamada Y, Jinzaki M, Tanami Y, et al: Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung. A pilot study. Invest Radiol. 2012, 47: 482-489. 10.1097/RLI.0b013e3182562a89.CrossRefPubMed
12.
go back to reference Katsura M, Matsuda I, Akahane M, et al: Model-base iterative reconstruction technique for radiation dose reduction in chest CT: comparison with adaptive statistical reconstruction technique. Eur Radiol. 2012, 22: 1613-1623. 10.1007/s00330-012-2452-z.CrossRefPubMed Katsura M, Matsuda I, Akahane M, et al: Model-base iterative reconstruction technique for radiation dose reduction in chest CT: comparison with adaptive statistical reconstruction technique. Eur Radiol. 2012, 22: 1613-1623. 10.1007/s00330-012-2452-z.CrossRefPubMed
14.
go back to reference Funama Y, Awai K, Miyazaki O, et al: Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: evaluation with a computer- simulated liver including tumors. Invest Radiol. 2006, 41: 1-7. 10.1097/01.rli.0000188026.20172.5d.CrossRefPubMed Funama Y, Awai K, Miyazaki O, et al: Improvement of low-contrast detectability in low-dose hepatic multidetector computed tomography using a novel adaptive filter: evaluation with a computer- simulated liver including tumors. Invest Radiol. 2006, 41: 1-7. 10.1097/01.rli.0000188026.20172.5d.CrossRefPubMed
15.
go back to reference Funama Y, Awai K, Nakayama Y, et al: Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology. 2005, 237: 905-910. 10.1148/radiol.2373041643.CrossRefPubMed Funama Y, Awai K, Nakayama Y, et al: Radiation dose reduction without degradation of low-contrast detectability at abdominal multisection CT with a low-tube voltage technique: phantom study. Radiology. 2005, 237: 905-910. 10.1148/radiol.2373041643.CrossRefPubMed
16.
go back to reference Kalra MK, Maher MM, Blake MA, et al: Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology. 2004, 232: 791-797. 10.1148/radiol.2323031563.CrossRefPubMed Kalra MK, Maher MM, Blake MA, et al: Detection and characterization of lesions on low-radiation-dose abdominal CT images postprocessed with noise reduction filters. Radiology. 2004, 232: 791-797. 10.1148/radiol.2323031563.CrossRefPubMed
17.
go back to reference Kalra MK, Maher MM, Toth TL, et al: Strategies for CT radiation dose optimization. Radiology. 2004, 230: 619-628. 10.1148/radiol.2303021726.CrossRefPubMed Kalra MK, Maher MM, Toth TL, et al: Strategies for CT radiation dose optimization. Radiology. 2004, 230: 619-628. 10.1148/radiol.2303021726.CrossRefPubMed
18.
go back to reference Linton OW, Mettler FA: National conference ondose reduction in CT, with an emphasis on pediatric patients. AJR. 2003, 181: 321-329. 10.2214/ajr.181.2.1810321.CrossRefPubMed Linton OW, Mettler FA: National conference ondose reduction in CT, with an emphasis on pediatric patients. AJR. 2003, 181: 321-329. 10.2214/ajr.181.2.1810321.CrossRefPubMed
19.
go back to reference Nakayama Y, Awai K, Funama Y, et al: Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology. 2005, 237: 945-951. 10.1148/radiol.2373041655.CrossRefPubMed Nakayama Y, Awai K, Funama Y, et al: Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise. Radiology. 2005, 237: 945-951. 10.1148/radiol.2373041655.CrossRefPubMed
20.
go back to reference Okumura M, Ota T, Kainuma K, Sayre JW, Mc-Nitt-Gray M, Katada K: Effect of edge-preserving adaptive image filter on low-contrast detectability in CT systems: application of ROC analysis. Int J Biomed Imaging. 2008, 2008: 379486-CrossRefPubMedPubMedCentral Okumura M, Ota T, Kainuma K, Sayre JW, Mc-Nitt-Gray M, Katada K: Effect of edge-preserving adaptive image filter on low-contrast detectability in CT systems: application of ROC analysis. Int J Biomed Imaging. 2008, 2008: 379486-CrossRefPubMedPubMedCentral
21.
go back to reference Valentin J: International Commission on Radiation Protection. Managing patient dose in multidetector computed tomography (MDCT): ICRP publication 102. Ann ICRP. 2007, 37: 1-79. Valentin J: International Commission on Radiation Protection. Managing patient dose in multidetector computed tomography (MDCT): ICRP publication 102. Ann ICRP. 2007, 37: 1-79.
22.
go back to reference Kalra MK, Maher MM, Sahani DV, et al: Low dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology. 2003, 228: 251-256. 10.1148/radiol.2281020693.CrossRefPubMed Kalra MK, Maher MM, Sahani DV, et al: Low dose CT of the abdomen: evaluation of image improvement with use of noise reduction filters pilot study. Radiology. 2003, 228: 251-256. 10.1148/radiol.2281020693.CrossRefPubMed
23.
go back to reference Ziegler A, Kohler T, Proska R: Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys. 2007, 34: 585-598. 10.1118/1.2409481.CrossRefPubMed Ziegler A, Kohler T, Proska R: Noise and resolution in images reconstructed with FBP and OSC algorithms for CT. Med Phys. 2007, 34: 585-598. 10.1118/1.2409481.CrossRefPubMed
24.
go back to reference Yu Z, Thibault J, Bouman C, Sauer K, Hsieh J: Fast model-base X-ray CT reconstruction using spatially non-homogeneous ICD optimization. IEEE Trans Image Process. 2011, 20: 161-175.CrossRefPubMed Yu Z, Thibault J, Bouman C, Sauer K, Hsieh J: Fast model-base X-ray CT reconstruction using spatially non-homogeneous ICD optimization. IEEE Trans Image Process. 2011, 20: 161-175.CrossRefPubMed
25.
go back to reference Scheffel H, Stolzmann P, Schlett CL, et al: Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol. 2011, in press Scheffel H, Stolzmann P, Schlett CL, et al: Coronary artery plaques: Cardiac CT with model-based and adaptive-statistical iterative reconstruction technique. Eur J Radiol. 2011, in press
Metadata
Title
CT of the chest with model-based, fully iterative reconstruction: comparison with adaptive statistical iterative reconstruction
Authors
Yasutaka Ichikawa
Kakuya Kitagawa
Naoki Nagasawa
Shuichi Murashima
Hajime Sakuma
Publication date
01-12-2013
Publisher
BioMed Central
Published in
BMC Medical Imaging / Issue 1/2013
Electronic ISSN: 1471-2342
DOI
https://doi.org/10.1186/1471-2342-13-27

Other articles of this Issue 1/2013

BMC Medical Imaging 1/2013 Go to the issue