Skip to main content
Top
Published in: European Radiology 5/2021

01-05-2021 | Computed Tomography | Interventional

Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention

Authors: Ronald S. Arellano, Kai Yang, Madan M. Rehani

Published in: European Radiology | Issue 5/2021

Login to get access

Abstract

Objective

To identify a patient cohort who received ≥ 100 mSv during a single computed tomography (CT)-guided intervention and analyze clinical information.

Materials and methods

Using the dose-tracking platform Radimetrics that collects data from all CT scanners in a single hospital, a patient-level search was performed retrospectively by setting a threshold effective dose (E) of 100 mSv for the period from January 2013 to December 2017. Patients who received ≥ 100 mSv in a single day during a single CT-guided intervention were then identified. Procedure types were identified, and medical records were reviewed up to January 2020 to identify patients who developed short- and/or medium-term (up to 8 years) medical consequences.

Results

Of 8952 patients with 100 mSv+, there were 33 patients who underwent 37 CT-guided interventions each resulting in ≥ 100 mSv. Procedures included ablations (15), myelograms (8), drainages (7), biopsies (6), and other (1). The dose for individual procedures was 100.2 to 235.5 mSv with mean and median of 125.7 mSv and 111.8 mSv, respectively. Six patients (18 %) were less than 50 years of age. During the study period of 0.2 to 7 years, there were no deterministic or stochastic consequences identified in this study cohort.

Conclusions

While infrequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv. Awareness of the possibility of such high doses and potential for long-term deleterious effects, especially in younger patients, and consideration of alternative imaging guidance and/or further dose optimization should be strongly considered whenever feasible.

Key Points

• Although not so frequent, CT-guided interventions may result in a single procedure dose of ≥ 100 mSv
• Procedures with potential for high dose includes ablations, myelograms, drainages, and biopsies
Literature
1.
go back to reference Charalel RA, McGinty G, Brant-Zawadzki M et al (2015) Interventional radiology delivers high-value health care and is an Imaging 3.0 vanguard. J Am Coll Radiol 12:501–506CrossRef Charalel RA, McGinty G, Brant-Zawadzki M et al (2015) Interventional radiology delivers high-value health care and is an Imaging 3.0 vanguard. J Am Coll Radiol 12:501–506CrossRef
2.
go back to reference Mettler FA, Mahesh M, Bhargavan-Chatfield M et al (2020) Patient exposure from radiologic and nuclear medicine procedures in the United States: procedure volume and effective dose for the period 2006-2016. Radiology 295:418–427CrossRef Mettler FA, Mahesh M, Bhargavan-Chatfield M et al (2020) Patient exposure from radiologic and nuclear medicine procedures in the United States: procedure volume and effective dose for the period 2006-2016. Radiology 295:418–427CrossRef
3.
go back to reference Tsapaki V, Balter S, Cousins C et al (2018) The International Atomic Energy Agency action plan on radiation protection of patients and staff in interventional procedures: achieving change in practice. Phys Med 52:56–64 Tsapaki V, Balter S, Cousins C et al (2018) The International Atomic Energy Agency action plan on radiation protection of patients and staff in interventional procedures: achieving change in practice. Phys Med 52:56–64
5.
go back to reference Rehani MM, Vano E, Ciraj-Bjelac O, Kleiman NJ (2011) Radiation and cataract. Radiat Prot Dosimetry 147:300–304CrossRef Rehani MM, Vano E, Ciraj-Bjelac O, Kleiman NJ (2011) Radiation and cataract. Radiat Prot Dosimetry 147:300–304CrossRef
6.
go back to reference Balter S, Hopewell JW, Miller DL, Wagner LK, Zelefsky MJ (2010) Fluoroscopically guided interventional procedures: a review of radiation effects on patients’ skin and hair. Radiology 254:326–341CrossRef Balter S, Hopewell JW, Miller DL, Wagner LK, Zelefsky MJ (2010) Fluoroscopically guided interventional procedures: a review of radiation effects on patients’ skin and hair. Radiology 254:326–341CrossRef
8.
go back to reference Liu B, Hirsch JA, Li X et al (2019) Radiation dose monitoring for fluoroscopically guided interventional procedures: effect on patient radiation exposure. Radiology 290:744–749CrossRef Liu B, Hirsch JA, Li X et al (2019) Radiation dose monitoring for fluoroscopically guided interventional procedures: effect on patient radiation exposure. Radiology 290:744–749CrossRef
9.
go back to reference Kostova-Lefterova D, Vassileva J, Rehani MM (2017) Lessons from two cases of radiation induced skin injuries in fluoroscopic procedures in Bulgaria. J Radiol Prot 37:938–946CrossRef Kostova-Lefterova D, Vassileva J, Rehani MM (2017) Lessons from two cases of radiation induced skin injuries in fluoroscopic procedures in Bulgaria. J Radiol Prot 37:938–946CrossRef
11.
go back to reference Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505CrossRef Pearce MS, Salotti JA, Little MP et al (2012) Radiation exposure from CT scans in childhood and subsequent risk of leukaemia and brain tumours: a retrospective cohort study. Lancet 380:499–505CrossRef
13.
go back to reference Brambilla M, Marano G, Dominietto M, Cotroneo AR, Carriero A (2004) Patient radiation doses and references levels in interventional radiology. Radiol Med 107:408–418PubMed Brambilla M, Marano G, Dominietto M, Cotroneo AR, Carriero A (2004) Patient radiation doses and references levels in interventional radiology. Radiol Med 107:408–418PubMed
14.
go back to reference Mettler FA, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRef Mettler FA, Huda W, Yoshizumi TT, Mahesh M (2008) Effective doses in radiology and diagnostic nuclear medicine: a catalog. Radiology 248:254–263CrossRef
15.
go back to reference Leng S, Christner JA, Carlson SK et al (2011) Radiation dose levels for interventional CT procedures. AJR Am J Roentgenol 197:W97–W103CrossRef Leng S, Christner JA, Carlson SK et al (2011) Radiation dose levels for interventional CT procedures. AJR Am J Roentgenol 197:W97–W103CrossRef
16.
go back to reference Rehani MM, Yang K, Melick ER et al (2020) Patients undergoing recurrent CT scans: assessing the magnitude. Eur Radiol 30:1828–1836CrossRef Rehani MM, Yang K, Melick ER et al (2020) Patients undergoing recurrent CT scans: assessing the magnitude. Eur Radiol 30:1828–1836CrossRef
17.
go back to reference National Council of Radiation Protection and Measurements (2018) Implications of recent epidemiologic studies for the linear-non threshold model and radiation protection. NCRP Commentary No. 27. Bethesda, Maryland: NCRP National Council of Radiation Protection and Measurements (2018) Implications of recent epidemiologic studies for the linear-non threshold model and radiation protection. NCRP Commentary No. 27. Bethesda, Maryland: NCRP
19.
go back to reference Yang K, Ganguli S, DeLorenzo MC, Zheng H, Li X, Liu B (2018) Procedure-specific CT dose and utilization factors for CT-guided interventional procedures. Radiology 289:150–157CrossRef Yang K, Ganguli S, DeLorenzo MC, Zheng H, Li X, Liu B (2018) Procedure-specific CT dose and utilization factors for CT-guided interventional procedures. Radiology 289:150–157CrossRef
20.
go back to reference Jones AK, Dixon RG, Collins JD, Walser EM, Nikolic B (2018) Society OIRHASC. Best practice guidelines for CT-guided interventional procedures. J Vasc Interv Radiol 29:518–519CrossRef Jones AK, Dixon RG, Collins JD, Walser EM, Nikolic B (2018) Society OIRHASC. Best practice guidelines for CT-guided interventional procedures. J Vasc Interv Radiol 29:518–519CrossRef
21.
go back to reference Li X, Yang K, Liu B (2019) Exam-level dose monitoring in CT: quality metric consideration for multiple series acquisitions. Med Phys 46:1575–1580CrossRef Li X, Yang K, Liu B (2019) Exam-level dose monitoring in CT: quality metric consideration for multiple series acquisitions. Med Phys 46:1575–1580CrossRef
22.
go back to reference Rehani MM, Melick ER, Alvi RM et al (2020) Patients undergoing recurrent CT exams: assessment of patients with non-malignant diseases, reasons for imaging and imaging appropriateness. Eur Radiol 30:1839–1846CrossRef Rehani MM, Melick ER, Alvi RM et al (2020) Patients undergoing recurrent CT exams: assessment of patients with non-malignant diseases, reasons for imaging and imaging appropriateness. Eur Radiol 30:1839–1846CrossRef
23.
go back to reference Yang K, Li Z, Li X, Liu B (2019) Characterization of dynamic collimation mechanisms for helical CT scans with direct measurements. Phys Med Biol 64:215006CrossRef Yang K, Li Z, Li X, Liu B (2019) Characterization of dynamic collimation mechanisms for helical CT scans with direct measurements. Phys Med Biol 64:215006CrossRef
24.
go back to reference Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRef Carlson SK, Felmlee JP, Bender CE et al (2005) CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 237:701–708CrossRef
25.
go back to reference Artner J, Cakir B, Reichel H, Lattig F (2012) Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations. J Pain Res 5:265–269CrossRef Artner J, Cakir B, Reichel H, Lattig F (2012) Radiation dose reduction in CT-guided sacroiliac joint injections to levels of pulsed fluoroscopy: a comparative study with technical considerations. J Pain Res 5:265–269CrossRef
26.
go back to reference Kloeckner R, dos Santos DP, Schneider J, Kara L, Dueber C, Pitton MB (2013) Radiation exposure in CT-guided interventions. Eur J Radiol 82:2253–2257CrossRef Kloeckner R, dos Santos DP, Schneider J, Kara L, Dueber C, Pitton MB (2013) Radiation exposure in CT-guided interventions. Eur J Radiol 82:2253–2257CrossRef
27.
go back to reference McCarthy CJ, Kilcoyne A, Li X et al (2018) Radiation dose and risk estimates of CT-guided percutaneous liver ablations and factors associated with dose reduction. Cardiovasc Intervent Radiol 41:1935–1942CrossRef McCarthy CJ, Kilcoyne A, Li X et al (2018) Radiation dose and risk estimates of CT-guided percutaneous liver ablations and factors associated with dose reduction. Cardiovasc Intervent Radiol 41:1935–1942CrossRef
28.
go back to reference Eisenberg JD, Gervais DA, Singh S et al (2015) Radiation exposure from CT-guided ablation of renal masses: effects on life expectancy. AJR Am J Roentgenol 204:335–342CrossRef Eisenberg JD, Gervais DA, Singh S et al (2015) Radiation exposure from CT-guided ablation of renal masses: effects on life expectancy. AJR Am J Roentgenol 204:335–342CrossRef
29.
go back to reference Crocetti L, Lencioni R, Debeni S, See TC, Pina CD, Bartolozzi C (2008) Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system. Invest Radiol 43:33–39CrossRef Crocetti L, Lencioni R, Debeni S, See TC, Pina CD, Bartolozzi C (2008) Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system. Invest Radiol 43:33–39CrossRef
Metadata
Title
Analysis of patients receiving ≥ 100 mSv during a computed tomography intervention
Authors
Ronald S. Arellano
Kai Yang
Madan M. Rehani
Publication date
01-05-2021
Publisher
Springer Berlin Heidelberg
Published in
European Radiology / Issue 5/2021
Print ISSN: 0938-7994
Electronic ISSN: 1432-1084
DOI
https://doi.org/10.1007/s00330-020-07458-5

Other articles of this Issue 5/2021