Skip to main content
Top
Published in: Abdominal Radiology 1/2019

01-01-2019

Can MR elastography be used to measure liver stiffness in patients with iron overload?

Authors: Suraj D. Serai, Andrew T. Trout

Published in: Abdominal Radiology | Issue 1/2019

Login to get access

Abstract

Untreated hepatic iron overload causes hepatic fibrosis and cirrhosis and can predispose to hepatocellular carcinoma. MR elastography (MRE) provides a non-invasive means to measure liver stiffness, which correlates with liver fibrosis but standard gradient recalled echo (GRE)-based MRE techniques fail in patients with high iron due to very low hepatic signal. Short echo time (TE) 2D spin echo echoplanar imaging (SE-EPI)-based MRE may allow measurement of stiffness in the iron loaded liver. The purpose of this study was to describe the use of such an MRE sequence in patients undergoing liver iron quantification by MRI. In our preliminary study of 43 patients with mean LIC of 9.3 mg/g (range 1.8–21.5 mg/g), liver stiffness measurements could be made in 77% (33/43) of patients with a short TE, SE-EPI based MRE sequence. On average, mean LIC in patients with failed MRE was higher than in those with successful MRE (15.9 mg/g dry weight vs. 7.3 mg/g), but a cut-off value for successful MRE could not be established. Seven patients (21% of those with successful MRE) had liver stiffness values suggestive of the presence of significant fibrosis (> 2.49 kPa). A short TE, SE-EPI based MR elastography sequence allows successful measurement of liver stiffness in a majority of patients with liver iron loading, potentially allowing non-invasive screening for fibrosis.
Literature
1.
go back to reference Brown K, Subramony C, May W, et al. (2009) Hepatic iron overload in children with sickle cell anemia on chronic transfusion therapy. J Pediatr Hematol Oncol 31(5):309–312CrossRefPubMed Brown K, Subramony C, May W, et al. (2009) Hepatic iron overload in children with sickle cell anemia on chronic transfusion therapy. J Pediatr Hematol Oncol 31(5):309–312CrossRefPubMed
2.
go back to reference Ware HM, Kwiatkowski JL (2013) Evaluation and treatment of transfusional iron overload in children. Pediatr Clin North Am 60(6):1393–1406CrossRefPubMed Ware HM, Kwiatkowski JL (2013) Evaluation and treatment of transfusional iron overload in children. Pediatr Clin North Am 60(6):1393–1406CrossRefPubMed
3.
go back to reference Ghavamzadeh A, Mirzania M, Kamalian N, Sedighi N, Azimi P (2015) Hepatic iron overload and fibrosis in patients with beta thalassemia major after hematopoietic stem cell transplantation: a pilot study. Int Journal Hematol Oncol Stem Cell Res 9(2):55–59 Ghavamzadeh A, Mirzania M, Kamalian N, Sedighi N, Azimi P (2015) Hepatic iron overload and fibrosis in patients with beta thalassemia major after hematopoietic stem cell transplantation: a pilot study. Int Journal Hematol Oncol Stem Cell Res 9(2):55–59
4.
5.
go back to reference Towbin AJ, Serai SD, Podberesky DJ (2013) Magnetic resonance imaging of the pediatric liver: imaging of steatosis, iron deposition, and fibrosis. Magn Reson Imaging Clin N Am 21(4):669–680CrossRefPubMed Towbin AJ, Serai SD, Podberesky DJ (2013) Magnetic resonance imaging of the pediatric liver: imaging of steatosis, iron deposition, and fibrosis. Magn Reson Imaging Clin N Am 21(4):669–680CrossRefPubMed
6.
go back to reference Serai SD, Trout AT, Sirlin CB (2017) Elastography to assess the stage of liver fibrosis in children: concepts, opportunities, and challenges. Clin Liver Dis 9(1):5–10CrossRef Serai SD, Trout AT, Sirlin CB (2017) Elastography to assess the stage of liver fibrosis in children: concepts, opportunities, and challenges. Clin Liver Dis 9(1):5–10CrossRef
7.
go back to reference Serai SD, Towbin AJ, Podberesky DJ (2012) Pediatric liver MR elastography. Dig Dis Sci 57(10):2713–2719CrossRefPubMed Serai SD, Towbin AJ, Podberesky DJ (2012) Pediatric liver MR elastography. Dig Dis Sci 57(10):2713–2719CrossRefPubMed
8.
go back to reference Serai SD, Dillman JR, Trout AT (2017) Spin-echo echo-planar imaging MR elastography versus gradient-echo MR elastography for assessment of liver stiffness in children and young adults suspected of having liver disease. Radiology 282(3):761–770CrossRefPubMed Serai SD, Dillman JR, Trout AT (2017) Spin-echo echo-planar imaging MR elastography versus gradient-echo MR elastography for assessment of liver stiffness in children and young adults suspected of having liver disease. Radiology 282(3):761–770CrossRefPubMed
9.
go back to reference Mariappan YK, Dzyubak B, Glaser KJ, et al. (2016) Application of modified spin-echo-based sequences for hepatic MR elastography: evaluation, comparison with the conventional gradient-echo sequence, and preliminary clinical experience. Radiology. 282:390–398CrossRefPubMedPubMedCentral Mariappan YK, Dzyubak B, Glaser KJ, et al. (2016) Application of modified spin-echo-based sequences for hepatic MR elastography: evaluation, comparison with the conventional gradient-echo sequence, and preliminary clinical experience. Radiology. 282:390–398CrossRefPubMedPubMedCentral
10.
go back to reference Mariappan YK, Glaser KJ, Hubmayr RD, et al. (2011) MR elastography of human lung parenchyma: technical development, theoretical modeling and in vivo validation. J Magn Reson Imaging 33(6):1351–1361CrossRefPubMedPubMedCentral Mariappan YK, Glaser KJ, Hubmayr RD, et al. (2011) MR elastography of human lung parenchyma: technical development, theoretical modeling and in vivo validation. J Magn Reson Imaging 33(6):1351–1361CrossRefPubMedPubMedCentral
11.
go back to reference Wood JC, Enriquez C, Ghugre N, et al. (2005) MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 106(4):1460–1465CrossRefPubMedPubMedCentral Wood JC, Enriquez C, Ghugre N, et al. (2005) MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood 106(4):1460–1465CrossRefPubMedPubMedCentral
12.
go back to reference Serai SD, Fleck RJ, Quinn CT, Zhang B, Podberesky DJ (2015) Retrospective comparison of gradient recalled echo R2* and spin-echo R2 magnetic resonance analysis methods for estimating liver iron content in children and adolescents. Pediatr Radiol 45(11):1629–1634CrossRefPubMed Serai SD, Fleck RJ, Quinn CT, Zhang B, Podberesky DJ (2015) Retrospective comparison of gradient recalled echo R2* and spin-echo R2 magnetic resonance analysis methods for estimating liver iron content in children and adolescents. Pediatr Radiol 45(11):1629–1634CrossRefPubMed
13.
go back to reference Serai SD, Smith EA, Trout AT, Dillman JR (2017) Agreement between manual relaxometry and semi-automated scanner-based multi-echo Dixon technique for measuring liver T2* in a pediatric and young adult population. Pediatr Radiol. 48:94–100CrossRefPubMed Serai SD, Smith EA, Trout AT, Dillman JR (2017) Agreement between manual relaxometry and semi-automated scanner-based multi-echo Dixon technique for measuring liver T2* in a pediatric and young adult population. Pediatr Radiol. 48:94–100CrossRefPubMed
15.
go back to reference Xanthakos SA, Podberesky DJ, Serai SD, et al. (2014) Use of magnetic resonance elastography to assess hepatic fibrosis in children with chronic liver disease. J Pediatr 164(1):186–188CrossRefPubMed Xanthakos SA, Podberesky DJ, Serai SD, et al. (2014) Use of magnetic resonance elastography to assess hepatic fibrosis in children with chronic liver disease. J Pediatr 164(1):186–188CrossRefPubMed
16.
go back to reference Garbowski MW, Carpenter JP, Smith G, et al. (2014) Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan. J Cardiovasc Magn Reson 16:40CrossRefPubMedPubMedCentral Garbowski MW, Carpenter JP, Smith G, et al. (2014) Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan. J Cardiovasc Magn Reson 16:40CrossRefPubMedPubMedCentral
17.
go back to reference Dillman JR, Trout AT, Costello EN, et al. (2018) Quantitative liver MRI-biopsy correlation in pediatric and young adult patients with nonalcoholic fatty liver disease: can one be used to predict the other? AJR Am J Roentgenol 210(1):166–174CrossRefPubMed Dillman JR, Trout AT, Costello EN, et al. (2018) Quantitative liver MRI-biopsy correlation in pediatric and young adult patients with nonalcoholic fatty liver disease: can one be used to predict the other? AJR Am J Roentgenol 210(1):166–174CrossRefPubMed
19.
go back to reference Trout ATSR, Serai SD, Xanthakos SA, et al. (2018) Diagnostic performance of MR elastography for liver fibrosis in children and young adults with a spectrum of liver diseases. Radiology. 287:824–832CrossRefPubMed Trout ATSR, Serai SD, Xanthakos SA, et al. (2018) Diagnostic performance of MR elastography for liver fibrosis in children and young adults with a spectrum of liver diseases. Radiology. 287:824–832CrossRefPubMed
20.
go back to reference Maira D, Cassinerio E, Marcon A, et al. (2017) Progression of liver fibrosis can be controlled by adequate chelation in transfusion-dependent thalassemia (TDT). Ann Hematol 96(11):1931–1936CrossRefPubMed Maira D, Cassinerio E, Marcon A, et al. (2017) Progression of liver fibrosis can be controlled by adequate chelation in transfusion-dependent thalassemia (TDT). Ann Hematol 96(11):1931–1936CrossRefPubMed
22.
go back to reference Wood JC (2014) Use of Magnetic resonance imaging to monitor iron overload. Hematol Oncol Clin N Am 28(4):747–764CrossRef Wood JC (2014) Use of Magnetic resonance imaging to monitor iron overload. Hematol Oncol Clin N Am 28(4):747–764CrossRef
23.
go back to reference Joshi M, Dillman JR, Singh K, et al. (2017) Quantitative MRI of fatty liver disease in a large pediatric cohort: correlation between liver fat fraction, stiffness, volume, and patient-specific factors. Abdom Radiol. 43:1168–1179CrossRef Joshi M, Dillman JR, Singh K, et al. (2017) Quantitative MRI of fatty liver disease in a large pediatric cohort: correlation between liver fat fraction, stiffness, volume, and patient-specific factors. Abdom Radiol. 43:1168–1179CrossRef
24.
go back to reference Joshi M, Dillman JR, Towbin AJ, Serai SD, Trout AT (2017) MR elastography: high rate of technical success in pediatric and young adult patients. Pediatr Radiol 47(7):838–843CrossRefPubMed Joshi M, Dillman JR, Towbin AJ, Serai SD, Trout AT (2017) MR elastography: high rate of technical success in pediatric and young adult patients. Pediatr Radiol 47(7):838–843CrossRefPubMed
25.
go back to reference Trout AT, Sheridan RM, Serai SD, et al. (2018) Diagnostic performance of MR elastography for liver fibrosis in children and young adults with a spectrum of liver diseases. Radiology 287(3):824–832CrossRefPubMed Trout AT, Sheridan RM, Serai SD, et al. (2018) Diagnostic performance of MR elastography for liver fibrosis in children and young adults with a spectrum of liver diseases. Radiology 287(3):824–832CrossRefPubMed
26.
go back to reference Paparo F, Cevasco L, Zefiro D, et al. (2013) Diagnostic value of real-time elastography in the assessment of hepatic fibrosis in patients with liver iron overload. Eur J Radiol 82(12):e755–e761CrossRefPubMed Paparo F, Cevasco L, Zefiro D, et al. (2013) Diagnostic value of real-time elastography in the assessment of hepatic fibrosis in patients with liver iron overload. Eur J Radiol 82(12):e755–e761CrossRefPubMed
27.
go back to reference Hamidieh AA, Shazad B, Ostovaneh MR, et al. (2014) Noninvasive measurement of liver fibrosis using transient elastography in pediatric patients with major thalassemia who are candidates for hematopoietic stem cell transplantation. Biol Blood Marrow Transplant 20(12):1912–1917CrossRefPubMed Hamidieh AA, Shazad B, Ostovaneh MR, et al. (2014) Noninvasive measurement of liver fibrosis using transient elastography in pediatric patients with major thalassemia who are candidates for hematopoietic stem cell transplantation. Biol Blood Marrow Transplant 20(12):1912–1917CrossRefPubMed
28.
go back to reference Pipaliya N, Solanke D, Parikh P, et al. (2017) Comparison of tissue elastography with magnetic resonance imaging T2* and serum ferritin quantification in detecting liver iron overload in patients with thalassemia major. Clin Gastroenterol Hepatol. 15(2):292CrossRefPubMed Pipaliya N, Solanke D, Parikh P, et al. (2017) Comparison of tissue elastography with magnetic resonance imaging T2* and serum ferritin quantification in detecting liver iron overload in patients with thalassemia major. Clin Gastroenterol Hepatol. 15(2):292CrossRefPubMed
29.
go back to reference Serai S, Towbin AJ, Podberesky DJ (2012) Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging. Pediatr Radiol 42(3):364–368CrossRefPubMed Serai S, Towbin AJ, Podberesky DJ (2012) Non-contrast MRA using an inflow-enhanced, inversion recovery SSFP technique in pediatric abdominal imaging. Pediatr Radiol 42(3):364–368CrossRefPubMed
30.
go back to reference Elalfy MS, Esmat G, Matter RM, Abdel Aziz HE, Massoud WA (2013) Liver fibrosis in young Egyptian beta-thalassemia major patients: relation to hepatitis C virus and compliance with chelation. Ann Hepatol. 12(1):54–61CrossRef Elalfy MS, Esmat G, Matter RM, Abdel Aziz HE, Massoud WA (2013) Liver fibrosis in young Egyptian beta-thalassemia major patients: relation to hepatitis C virus and compliance with chelation. Ann Hepatol. 12(1):54–61CrossRef
Metadata
Title
Can MR elastography be used to measure liver stiffness in patients with iron overload?
Authors
Suraj D. Serai
Andrew T. Trout
Publication date
01-01-2019
Publisher
Springer US
Published in
Abdominal Radiology / Issue 1/2019
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-018-1723-9

Other articles of this Issue 1/2019

Abdominal Radiology 1/2019 Go to the issue