Background

There is a need to standardise non-invasive measurements of liver iron concentrations (LIC) so clear inferences can be drawn about body iron levels that are associated with hepatic and extra-hepatic complications of iron overload. Since the first demonstration of an inverse relationship between biopsy LIC and liver magnetic resonance (MR) using a proof-of-concept T2* sequence, MR technology has advanced dramatically with a shorter minimum echo-time, closer inter-echo spacing and constant repetition time. These important advances allow more accurate calculation of liver T2* especially in patients with high LIC.

Methods

Here, we used an optimised liver T2* sequence calibrated against 50 liver biopsy samples on 25 patients with transfusional haemosiderosis using ordinary least squares linear regression, and assessed the method reproducibility in 96 scans over an LIC range up to 42 mg/g dry weight (dw) using Bland-Altman plots. Using mixed model linear regression we compared the new T2*-LIC with R2-LIC (Ferriscan) on 92 scans in 54 patients with transfusional haemosiderosis and examined method agreement using Bland-Altman approach.

Results

Strong linear correlation between ln(T2*) and ln(LIC) led to the calibration equation LIC = 31.94(T2*)-1.014. This yielded LIC values approximately 2.2 times higher than the proof-of-concept T2* method. Comparing this new T2*-LIC with the R2-LIC (Ferriscan) technique in 92 scans, we observed a close relationship between the two methods for values up to 10 mg/g dw, however the method agreement was poor.

Conclusions

New calibration of T2* against liver biopsy estimates LIC in a reproducible way, correcting the proof-of-concept calibration by 2.2 times. Due to poor agreement, both methods should be used separately to diagnose or rule out liver iron overload in patients with increased ferritin.
Appendix
Available only for authorised users
Literature
1.
go back to reference Angelucci E, Brittenham GM, McLaren CE, Ripalti M, Baronciani D, Giardini C, Galimberti M, Polchi P, Lucarelli G: Hepatic iron concentration and total body iron stores in thalassemia major. N Engl J Med. 2000, 343: 327-331. 10.1056/NEJM200008033430503.CrossRefPubMed Angelucci E, Brittenham GM, McLaren CE, Ripalti M, Baronciani D, Giardini C, Galimberti M, Polchi P, Lucarelli G: Hepatic iron concentration and total body iron stores in thalassemia major. N Engl J Med. 2000, 343: 327-331. 10.1056/NEJM200008033430503.CrossRefPubMed
2.
go back to reference Porter J, Galanello R, Saglio G, Neufeld EJ, Vichinsky E, Cappellini MD, Olivieri N, Piga A, Cunningham MJ, Soulieres D, Gattermann N, Tchernia G, Maertens J, Giardina P, Kwiatkowski J, Quarta G, Jeng M, Forni GL, Stadler M, Cario H, Debusscher L, Della Porta M, Cazzola M, Greenberg P, Alimena G, Rabault B, Gathmann I, Ford JM, Alberti D, Rose C: Relative response of patients with myelodysplastic syndromes and other transfusion-dependent anaemias to deferasirox (ICL670): a 1-yr prospective study. Eur J Haematol. 2008, 80: 168-176.PubMedCentralPubMed Porter J, Galanello R, Saglio G, Neufeld EJ, Vichinsky E, Cappellini MD, Olivieri N, Piga A, Cunningham MJ, Soulieres D, Gattermann N, Tchernia G, Maertens J, Giardina P, Kwiatkowski J, Quarta G, Jeng M, Forni GL, Stadler M, Cario H, Debusscher L, Della Porta M, Cazzola M, Greenberg P, Alimena G, Rabault B, Gathmann I, Ford JM, Alberti D, Rose C: Relative response of patients with myelodysplastic syndromes and other transfusion-dependent anaemias to deferasirox (ICL670): a 1-yr prospective study. Eur J Haematol. 2008, 80: 168-176.PubMedCentralPubMed
3.
go back to reference Aydinok Y, Ulger Z, Nart D, Terzi A, Cetiner N, Ellis G, Zimmermann A, Manz C: A randomized controlled 1-year study of daily deferiprone plus twice weekly desferrioxamine compared with daily deferiprone monotherapy in patients with thalassemia major. Haematologica. 2007, 92: 1599-1606. 10.3324/haematol.11414.CrossRefPubMed Aydinok Y, Ulger Z, Nart D, Terzi A, Cetiner N, Ellis G, Zimmermann A, Manz C: A randomized controlled 1-year study of daily deferiprone plus twice weekly desferrioxamine compared with daily deferiprone monotherapy in patients with thalassemia major. Haematologica. 2007, 92: 1599-1606. 10.3324/haematol.11414.CrossRefPubMed
4.
go back to reference Cappellini MD, Cohen A, Piga A, Bejaoui M, Perrotta S, Agaoglu L, Aydinok Y, Kattamis A, Kilinc Y, Porter J, Capra M, Galanello R, Fattoum S, Drelichman G, Magnano C, Verissimo M, Athanassiou-Metaxa M, Giardina P, Kourakli-Symeonidis A, Janka-Schaub G, Coates T, Vermylen C, Olivieri N, Thuret I, Opitz H, Ressayre-Djaffer C, Marks P, Alberti D: A phase 3 study of deferasirox (ICL670), a once-daily oral iron chelator, in patients with beta-thalassemia. Blood. 2006, 107: 3455-3462. 10.1182/blood-2005-08-3430.CrossRefPubMed Cappellini MD, Cohen A, Piga A, Bejaoui M, Perrotta S, Agaoglu L, Aydinok Y, Kattamis A, Kilinc Y, Porter J, Capra M, Galanello R, Fattoum S, Drelichman G, Magnano C, Verissimo M, Athanassiou-Metaxa M, Giardina P, Kourakli-Symeonidis A, Janka-Schaub G, Coates T, Vermylen C, Olivieri N, Thuret I, Opitz H, Ressayre-Djaffer C, Marks P, Alberti D: A phase 3 study of deferasirox (ICL670), a once-daily oral iron chelator, in patients with beta-thalassemia. Blood. 2006, 107: 3455-3462. 10.1182/blood-2005-08-3430.CrossRefPubMed
5.
go back to reference Brittenham GM, Cohen AR, McLaren CE, Martin MB, Griffith PM, Nienhuis AW, Young NS, Allen CJ, Farrell DE, Harris JW: Hepatic iron stores and plasma ferritin concentration in patients with sickle cell anemia and thalassemia major. Am J Hematol. 1993, 42: 81-85. 10.1002/ajh.2830420116.CrossRefPubMed Brittenham GM, Cohen AR, McLaren CE, Martin MB, Griffith PM, Nienhuis AW, Young NS, Allen CJ, Farrell DE, Harris JW: Hepatic iron stores and plasma ferritin concentration in patients with sickle cell anemia and thalassemia major. Am J Hematol. 1993, 42: 81-85. 10.1002/ajh.2830420116.CrossRefPubMed
6.
go back to reference Porter JB, Huehns ER: Transfusion and exchange transfusion in sickle cell anaemias, with particular reference to iron metabolism. Acta Haematol. 1987, 78: 198-205.CrossRefPubMed Porter JB, Huehns ER: Transfusion and exchange transfusion in sickle cell anaemias, with particular reference to iron metabolism. Acta Haematol. 1987, 78: 198-205.CrossRefPubMed
7.
go back to reference Chapman RW, Hussain MA, Gorman A, Laulicht M, Politis D, Flynn DM, Sherlock S, Hoffbrand AV: Effect of ascorbic acid deficiency on serum ferritin concentration in patients with beta-thalassaemia major and iron overload. J Clin Pathol. 1982, 35: 487-491. 10.1136/jcp.35.5.487.PubMedCentralCrossRefPubMed Chapman RW, Hussain MA, Gorman A, Laulicht M, Politis D, Flynn DM, Sherlock S, Hoffbrand AV: Effect of ascorbic acid deficiency on serum ferritin concentration in patients with beta-thalassaemia major and iron overload. J Clin Pathol. 1982, 35: 487-491. 10.1136/jcp.35.5.487.PubMedCentralCrossRefPubMed
8.
go back to reference Origa R, Galanello R, Ganz T, Giagu N, Maccioni L, Faa G, Nemeth E: Liver iron concentrations and urinary hepcidin in beta-thalassemia. Haematologica. 2007, 92: 583-588. 10.3324/haematol.10842.CrossRefPubMed Origa R, Galanello R, Ganz T, Giagu N, Maccioni L, Faa G, Nemeth E: Liver iron concentrations and urinary hepcidin in beta-thalassemia. Haematologica. 2007, 92: 583-588. 10.3324/haematol.10842.CrossRefPubMed
9.
go back to reference Puliyel M, Sposto R, Berdoukas VA, Hofstra TC, Nord A, Carson S, Wood J, Coates TD: Ferritin trends do not predict changes in total body iron in patients with transfusional iron overload. Am J Hematol. 2014, 89 (4): 391-394. 10.1002/ajh.23650.CrossRefPubMed Puliyel M, Sposto R, Berdoukas VA, Hofstra TC, Nord A, Carson S, Wood J, Coates TD: Ferritin trends do not predict changes in total body iron in patients with transfusional iron overload. Am J Hematol. 2014, 89 (4): 391-394. 10.1002/ajh.23650.CrossRefPubMed
10.
go back to reference Porter J, Elalfy M, Aydinok Y, Chan A, Lee S, Sutcharitchan P, Taher A, Habr D, Roubert B, El-Beshlawy A: Correlations of serum ferritin (sf) and liver iron concentration before and after 1 year of deferasirox treatment. Haematologia. 2010, 95 (suppl.2): 708- Porter J, Elalfy M, Aydinok Y, Chan A, Lee S, Sutcharitchan P, Taher A, Habr D, Roubert B, El-Beshlawy A: Correlations of serum ferritin (sf) and liver iron concentration before and after 1 year of deferasirox treatment. Haematologia. 2010, 95 (suppl.2): 708-
11.
go back to reference Brittenham GM, Sheth S, Allen CJ, Farrell DE: Noninvasive methods for quantitative assessment of transfusional iron overload in sickle cell disease. Semin Hematol. 2001, 38: 37-56.CrossRefPubMed Brittenham GM, Sheth S, Allen CJ, Farrell DE: Noninvasive methods for quantitative assessment of transfusional iron overload in sickle cell disease. Semin Hematol. 2001, 38: 37-56.CrossRefPubMed
12.
go back to reference Fischer R, Piga A, Harmatz P, Nielsen P: Monitoring long-term efficacy of iron chelation treatment with biomagnetic liver susceptometry. Ann N Y Acad Sci. 2005, 1054: 350-357. 10.1196/annals.1345.043.CrossRefPubMed Fischer R, Piga A, Harmatz P, Nielsen P: Monitoring long-term efficacy of iron chelation treatment with biomagnetic liver susceptometry. Ann N Y Acad Sci. 2005, 1054: 350-357. 10.1196/annals.1345.043.CrossRefPubMed
13.
go back to reference Jensen PD, Jensen FT, Christensen T, Eiskjaer H, Baandrup U, Nielsen JL: Evaluation of myocardial iron by magnetic resonance imaging during iron chelation therapy with deferrioxamine: indication of close relation between myocardial iron content and chelatable iron pool. Blood. 2003, 101: 4632-4639. 10.1182/blood-2002-09-2754.CrossRefPubMed Jensen PD, Jensen FT, Christensen T, Eiskjaer H, Baandrup U, Nielsen JL: Evaluation of myocardial iron by magnetic resonance imaging during iron chelation therapy with deferrioxamine: indication of close relation between myocardial iron content and chelatable iron pool. Blood. 2003, 101: 4632-4639. 10.1182/blood-2002-09-2754.CrossRefPubMed
14.
go back to reference St Pierre TG, Clark PR, Chua-anusorn W, Fleming AJ, Jeffrey GP, Olynyk JK, Pootrakul P, Robins E, Lindeman R: Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance. Blood. 2005, 105: 855-861. 10.1182/blood-2004-01-0177.CrossRefPubMed St Pierre TG, Clark PR, Chua-anusorn W, Fleming AJ, Jeffrey GP, Olynyk JK, Pootrakul P, Robins E, Lindeman R: Noninvasive measurement and imaging of liver iron concentrations using proton magnetic resonance. Blood. 2005, 105: 855-861. 10.1182/blood-2004-01-0177.CrossRefPubMed
15.
go back to reference Gandon Y, Olivie D, Guyader D, Aube C, Oberti F, Sebille V, Deugnier Y: Non-invasive assessment of hepatic iron stores by MRI. Lancet. 2004, 363: 357-362. 10.1016/S0140-6736(04)15436-6.CrossRefPubMed Gandon Y, Olivie D, Guyader D, Aube C, Oberti F, Sebille V, Deugnier Y: Non-invasive assessment of hepatic iron stores by MRI. Lancet. 2004, 363: 357-362. 10.1016/S0140-6736(04)15436-6.CrossRefPubMed
16.
go back to reference Anderson LJ, Holden S, Davis B, Prescott E, Charrier CC, Bunce NH, Firmin DN, Wonke B, Porter J, Walker JM, Pennell DJ: Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J. 2001, 22: 2171-2179. 10.1053/euhj.2001.2822.CrossRefPubMed Anderson LJ, Holden S, Davis B, Prescott E, Charrier CC, Bunce NH, Firmin DN, Wonke B, Porter J, Walker JM, Pennell DJ: Cardiovascular T2-star (T2*) magnetic resonance for the early diagnosis of myocardial iron overload. Eur Heart J. 2001, 22: 2171-2179. 10.1053/euhj.2001.2822.CrossRefPubMed
17.
go back to reference Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD, Coates TD: MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood. 2005, 106: 1460-1465. 10.1182/blood-2004-10-3982.PubMedCentralCrossRefPubMed Wood JC, Enriquez C, Ghugre N, Tyzka JM, Carson S, Nelson MD, Coates TD: MRI R2 and R2* mapping accurately estimates hepatic iron concentration in transfusion-dependent thalassemia and sickle cell disease patients. Blood. 2005, 106: 1460-1465. 10.1182/blood-2004-10-3982.PubMedCentralCrossRefPubMed
18.
go back to reference Hankins JS, McCarville MB, Loeffler RB, Smeltzer MP, Onciu M, Hoffer FA, Li CS, Wang WC, Ware RE, Hillenbrand CM: R2* magnetic resonance imaging of the liver in patients with iron overload. Blood. 2009, 113: 4853-4855. 10.1182/blood-2008-12-191643.PubMedCentralCrossRefPubMed Hankins JS, McCarville MB, Loeffler RB, Smeltzer MP, Onciu M, Hoffer FA, Li CS, Wang WC, Ware RE, Hillenbrand CM: R2* magnetic resonance imaging of the liver in patients with iron overload. Blood. 2009, 113: 4853-4855. 10.1182/blood-2008-12-191643.PubMedCentralCrossRefPubMed
19.
go back to reference Deugnier Y, Turlin B, Ropert M, Bejaoui M, Athanassiou-Metaxa M, Cario H, Vichinsky E, Opitz H, Ressayre-Djaffer C, Rabault B, Ford J: Semi-quantitative assessment of hemosiderin distribution accurately reflects reductions in liver iron concentration following therapy with Deferasirox (exjade®, ICL670) or Deferoxamine in patients with transfusion-dependent anemia. Blood. 2005, 106 (11 Suppl): abstract 2708- Deugnier Y, Turlin B, Ropert M, Bejaoui M, Athanassiou-Metaxa M, Cario H, Vichinsky E, Opitz H, Ressayre-Djaffer C, Rabault B, Ford J: Semi-quantitative assessment of hemosiderin distribution accurately reflects reductions in liver iron concentration following therapy with Deferasirox (exjade®, ICL670) or Deferoxamine in patients with transfusion-dependent anemia. Blood. 2005, 106 (11 Suppl): abstract 2708-
20.
go back to reference Cappellini MD, Porter J, El-Beshlawy A, Li CK, Seymour JF, Elalfy M, Gattermann N, Giraudier S, Lee JW, Chan LL, Lin KH, Rose C, Taher A, Thein SL, Viprakasit V, Habr D, Domokos G, Roubert B, Kattamis A, Investigators, Epic Study: Tailoring iron chelation by iron intake and serum ferritin: the prospective EPIC study of deferasirox in 1744 patients with transfusion-dependent anemias. Haematologica. 2010, 95: 557-566. 10.3324/haematol.2009.014696.PubMedCentralCrossRefPubMed Cappellini MD, Porter J, El-Beshlawy A, Li CK, Seymour JF, Elalfy M, Gattermann N, Giraudier S, Lee JW, Chan LL, Lin KH, Rose C, Taher A, Thein SL, Viprakasit V, Habr D, Domokos G, Roubert B, Kattamis A, Investigators, Epic Study: Tailoring iron chelation by iron intake and serum ferritin: the prospective EPIC study of deferasirox in 1744 patients with transfusion-dependent anemias. Haematologica. 2010, 95: 557-566. 10.3324/haematol.2009.014696.PubMedCentralCrossRefPubMed
21.
go back to reference Soriano MJ, de la Guardia M: A comparative study of flame atomic-absorption methods for determination of zinc in serum and blood plasma. Talanta. 1984, 31: 347-352. 10.1016/0039-9140(84)80094-6.CrossRefPubMed Soriano MJ, de la Guardia M: A comparative study of flame atomic-absorption methods for determination of zinc in serum and blood plasma. Talanta. 1984, 31: 347-352. 10.1016/0039-9140(84)80094-6.CrossRefPubMed
22.
go back to reference Ropert-Bouchet M, Turlin B, Graham G, Rabault B, Le Treut A, Brissot P, Loreal O, Alberti D, Deugnier Y: Drying methods affect the wet dry ratio of liver tissue samples and impact on iron content measurements. BioIron. 2005, 107: Abstract P274- Ropert-Bouchet M, Turlin B, Graham G, Rabault B, Le Treut A, Brissot P, Loreal O, Alberti D, Deugnier Y: Drying methods affect the wet dry ratio of liver tissue samples and impact on iron content measurements. BioIron. 2005, 107: Abstract P274-
23.
go back to reference He T, Kirk P, Firmin DN, Lam WM, Chu WC, Au WY, Chan GC, Tan RS, Ng I, Biceroglu S, Aydinok Y, Fogel MA, Cohen AR, Pennell DJ: Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment. J Cardiovasc Magn Reson. 2008, 10: 11-10.1186/1532-429X-10-11.PubMedCentralCrossRefPubMed He T, Kirk P, Firmin DN, Lam WM, Chu WC, Au WY, Chan GC, Tan RS, Ng I, Biceroglu S, Aydinok Y, Fogel MA, Cohen AR, Pennell DJ: Multi-center transferability of a breath-hold T2 technique for myocardial iron assessment. J Cardiovasc Magn Reson. 2008, 10: 11-10.1186/1532-429X-10-11.PubMedCentralCrossRefPubMed
24.
go back to reference Porter JB, Elalfy MS, Taher AT, Aydinok Y, Chan LL, Lee SH, Sutcharitchan P, Habr D, Martin N, El-Beshlawy A: Efficacy and safety of deferasirox at low and high iron burdens: results from the EPIC magnetic resonance imaging substudy. Ann Hematol. 2013, 92: 211-219. 10.1007/s00277-012-1588-x.PubMedCentralCrossRefPubMed Porter JB, Elalfy MS, Taher AT, Aydinok Y, Chan LL, Lee SH, Sutcharitchan P, Habr D, Martin N, El-Beshlawy A: Efficacy and safety of deferasirox at low and high iron burdens: results from the EPIC magnetic resonance imaging substudy. Ann Hematol. 2013, 92: 211-219. 10.1007/s00277-012-1588-x.PubMedCentralCrossRefPubMed
25.
go back to reference Bland JM, Altman DG: Measuring agreement in method comparison studies. Stat Methods Med Res. 1999, 8: 135-160. 10.1191/096228099673819272.CrossRefPubMed Bland JM, Altman DG: Measuring agreement in method comparison studies. Stat Methods Med Res. 1999, 8: 135-160. 10.1191/096228099673819272.CrossRefPubMed
26.
go back to reference Tanner MA, He T, Westwood MA, Firmin DN, Pennell DJ: Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron. Haematologica. 2006, 91: 1388-1391.PubMed Tanner MA, He T, Westwood MA, Firmin DN, Pennell DJ: Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron. Haematologica. 2006, 91: 1388-1391.PubMed
27.
go back to reference Angelucci E, Baronciani D, Lucarelli G, Baldassarri M, Galimberti M, Giardini C, Martinelli F, Polchi P, Polizzi V, Ripalti M, Muretto P: Needle liver biopsy in thalassaemia: analyses of diagnostic accuracy and safety in 1184 consecutive biopsies. Br J Haematol. 1995, 89: 757-761.CrossRefPubMed Angelucci E, Baronciani D, Lucarelli G, Baldassarri M, Galimberti M, Giardini C, Martinelli F, Polchi P, Polizzi V, Ripalti M, Muretto P: Needle liver biopsy in thalassaemia: analyses of diagnostic accuracy and safety in 1184 consecutive biopsies. Br J Haematol. 1995, 89: 757-761.CrossRefPubMed
28.
go back to reference Emond MJ, Bronner MP, Carlson TH, Lin M, Labbe RF, Kowdley KV: Quantitative study of the variability of hepatic iron concentrations. Clin Chem. 1999, 45: 340-346.PubMed Emond MJ, Bronner MP, Carlson TH, Lin M, Labbe RF, Kowdley KV: Quantitative study of the variability of hepatic iron concentrations. Clin Chem. 1999, 45: 340-346.PubMed
29.
go back to reference Barry M, Sherlock S: Measurement of liver-iron concentration in needle biopsy specimens. Lancet. 1971, 1: 100-103.CrossRefPubMed Barry M, Sherlock S: Measurement of liver-iron concentration in needle biopsy specimens. Lancet. 1971, 1: 100-103.CrossRefPubMed
30.
go back to reference Kreeftenberg HG, Koopman BJ, Huizenga JR, van Vilsteren T, Wolthers BG, Gips CH: Measurement of iron in liver biopsies–a comparison of three analytical methods. Clin Chim Acta. 1984, 144: 255-262. 10.1016/0009-8981(84)90061-5.CrossRefPubMed Kreeftenberg HG, Koopman BJ, Huizenga JR, van Vilsteren T, Wolthers BG, Gips CH: Measurement of iron in liver biopsies–a comparison of three analytical methods. Clin Chim Acta. 1984, 144: 255-262. 10.1016/0009-8981(84)90061-5.CrossRefPubMed
31.
go back to reference Westwood MA, Anderson LJ, Firmin DN, Gatehouse PD, Lorenz CH, Wonke B, Pennell DJ: Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. J Magn Reson Imaging. 2003, 18: 616-620. 10.1002/jmri.10396.CrossRefPubMed Westwood MA, Anderson LJ, Firmin DN, Gatehouse PD, Lorenz CH, Wonke B, Pennell DJ: Interscanner reproducibility of cardiovascular magnetic resonance T2* measurements of tissue iron in thalassemia. J Magn Reson Imaging. 2003, 18: 616-620. 10.1002/jmri.10396.CrossRefPubMed
32.
go back to reference Kirk P, He T, Anderson LJ, Roughton M, Tanner MA, Lam WW, Au WY, Chu WC, Chan G, Galanello R, Matta G, Fogel M, Cohen AR, Tan RS, Chen K, Ng I, Lai A, Fucharoen S, Laothamata J, Chuncharunee S, Jongjirasiri S, Firmin DN, Smith GC, Pennell DJ: International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. J Magn Reson Imaging. 2010, 32: 315-319. 10.1002/jmri.22245.PubMedCentralCrossRefPubMed Kirk P, He T, Anderson LJ, Roughton M, Tanner MA, Lam WW, Au WY, Chu WC, Chan G, Galanello R, Matta G, Fogel M, Cohen AR, Tan RS, Chen K, Ng I, Lai A, Fucharoen S, Laothamata J, Chuncharunee S, Jongjirasiri S, Firmin DN, Smith GC, Pennell DJ: International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. J Magn Reson Imaging. 2010, 32: 315-319. 10.1002/jmri.22245.PubMedCentralCrossRefPubMed
33.
go back to reference St Pierre TG, El-Beshlawy A, Elalfy M, Al Jefri A, Al Zir K, Daar S, Habr D, Kriemler-Krahn U, Taher A: Multicenter validation of spin-density projection-assisted R2-MRI for the noninvasive measurement of liver iron concentration. Magn Reson Med. 2014, 71 (6): 2215-2223. 10.1002/mrm.24854.PubMedCentralCrossRefPubMed St Pierre TG, El-Beshlawy A, Elalfy M, Al Jefri A, Al Zir K, Daar S, Habr D, Kriemler-Krahn U, Taher A: Multicenter validation of spin-density projection-assisted R2-MRI for the noninvasive measurement of liver iron concentration. Magn Reson Med. 2014, 71 (6): 2215-2223. 10.1002/mrm.24854.PubMedCentralCrossRefPubMed
34.
go back to reference McCarville MB, Hillenbrand CM, Loeffler RB, Smeltzer MP, Song R, Li CS, Hankins JS: Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload. Pediatr Radiol. 2010, 40: 1360-1367. 10.1007/s00247-010-1596-8.PubMedCentralCrossRefPubMed McCarville MB, Hillenbrand CM, Loeffler RB, Smeltzer MP, Song R, Li CS, Hankins JS: Comparison of whole liver and small region-of-interest measurements of MRI liver R2* in children with iron overload. Pediatr Radiol. 2010, 40: 1360-1367. 10.1007/s00247-010-1596-8.PubMedCentralCrossRefPubMed
35.
go back to reference Ghugre NR, Wood JC: Relaxivity-iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model. Magn Reson Med. 2011, 65: 837-847. 10.1002/mrm.22657.PubMedCentralCrossRefPubMed Ghugre NR, Wood JC: Relaxivity-iron calibration in hepatic iron overload: probing underlying biophysical mechanisms using a Monte Carlo model. Magn Reson Med. 2011, 65: 837-847. 10.1002/mrm.22657.PubMedCentralCrossRefPubMed
36.
go back to reference Wood JC, Zhang P, Rienhoff H, Abi-Saab W, Neufeld E: R2 and R2* are equally effective in evaluating chronic response to iron chelation. Am J Hematol. 2014, 89 (5): 505-508. 10.1002/ajh.23673.CrossRefPubMed Wood JC, Zhang P, Rienhoff H, Abi-Saab W, Neufeld E: R2 and R2* are equally effective in evaluating chronic response to iron chelation. Am J Hematol. 2014, 89 (5): 505-508. 10.1002/ajh.23673.CrossRefPubMed
37.
go back to reference Wood JC, Jones A, Rienhoff HY, Neufeld EJ: Disparities between Two common MRI metrics of liver iron concentration in transfusional siderosis. ASH Ann Meeting Abstracts. 2011, 118: 1088- Wood JC, Jones A, Rienhoff HY, Neufeld EJ: Disparities between Two common MRI metrics of liver iron concentration in transfusional siderosis. ASH Ann Meeting Abstracts. 2011, 118: 1088-
38.
go back to reference Butensky E, Fischer R, Hudes M, Schumacher L, Williams R, Moyer TP, Vichinsky E, Harmatz P: Variability in hepatic iron concentration in percutaneous needle biopsy specimens from patients with transfusional hemosiderosis. Am J Clin Pathol. 2005, 123: 146-152. 10.1309/PUUXEGXDLH26NXA2.CrossRefPubMed Butensky E, Fischer R, Hudes M, Schumacher L, Williams R, Moyer TP, Vichinsky E, Harmatz P: Variability in hepatic iron concentration in percutaneous needle biopsy specimens from patients with transfusional hemosiderosis. Am J Clin Pathol. 2005, 123: 146-152. 10.1309/PUUXEGXDLH26NXA2.CrossRefPubMed
39.
go back to reference Feng Y, He T, Gatehouse PD, Li X, Harith Alam M, Pennell DJ, Chen W, Firmin DN: Improved MRI R2* relaxometry of iron-loaded liver with noise correction. Magn Reson Med. 2013, 70 (6): 1765-1774. 10.1002/mrm.24607.CrossRefPubMed Feng Y, He T, Gatehouse PD, Li X, Harith Alam M, Pennell DJ, Chen W, Firmin DN: Improved MRI R2* relaxometry of iron-loaded liver with noise correction. Magn Reson Med. 2013, 70 (6): 1765-1774. 10.1002/mrm.24607.CrossRefPubMed
Metadata
Title
Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan
Authors
Maciej W Garbowski
John-Paul Carpenter
Gillian Smith
Michael Roughton
Mohammed H Alam
Taigang He
Dudley J Pennell
John B Porter
Publication date
01-12-2014
Publisher
BioMed Central
Published in
Journal of Cardiovascular Magnetic Resonance / Issue 1/2014
Electronic ISSN: 1532-429X
DOI
https://doi.org/10.1186/1532-429X-16-40

Other articles of this Issue 1/2014

Journal of Cardiovascular Magnetic Resonance 1/2014 Go to the issue