Skip to main content
Top
Published in: European Archives of Oto-Rhino-Laryngology 3/2017

01-03-2017 | Review Article

A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis

Authors: Yingwei Luo, Xi Li, Jianwei Dong, Weifeng Sun

Published in: European Archives of Oto-Rhino-Laryngology | Issue 3/2017

Login to get access

Abstract

This meta-analysis compared harmonic scalpel and LigaSure® systems with the conventional clamp-and-tie technique in thyroidectomy. Medline, Cochrane, EMBASE, and Google Scholar databases were searched until December 30, 2015. Randomized controlled studies (RCTs) or two-arm prospective studies were included. The primary outcome was operation time. The data were evaluated both by pair-wise meta-analyses and network meta-analysis within a Bayesian framework using Markov chain Monte Carlo methods. Compared with the conventional hemostasis, there was a significant reduction in operation time with harmonic scalpel (HS) and LigaSure (LS) (difference in means = −24.27 min, 95 % CI −28.11 to −20.44 min, P < 0.001; and difference in means = −13.08 min, 95 % CI −16.88 to −9.27 min, P < 0.001, respectively). For total thyroidectomy and hemi-thyroidectomy, subgroup pair-wise meta-analyses found a reduction of 26.31 and 21.90 min in operation time for harmonic scalpel, and a reduction of 12.77 and 17.48 min for LigaSure, respectively. Among studies with mixed total and hemi-thyroidectomy, no significant difference in operation time was seen between harmonic scalpel and the conventional hemostasis (P = 0.313). Network meta-analysis also found harmonic scalpel and LigaSure to have less operation time than the conventional hemostasis, and that harmonic scalpel was associated with a significant 9.78 min reduction in operation time than LigaSure which was not seen in pair-wise comparison. Harmonic scalpel had significantly less risk of definitive recurrent laryngeal nerve palsy, intra-operation blood loss, and post-operation bleeding than the conventional hemostasis. LigaSure was associated with significantly less intra-operative blood loss than the conventional hemostasis (P = 0.023). There was no significant difference among three different procedures in rates of transient recurrent laryngeal nerve palsy. This study found that harmonic scalpel and LigaSure decreased operation time compared with the conventional hemostasis and that harmonic scalpels was associated with the lowest operation time.
Appendix
Available only for authorised users
Literature
4.
go back to reference Roye GD, Monchik J, Amaral JF (2000) Endoscopic adrenalectomy using ultrasonic cutting and coagulating. Surg Technol Int IX:129–138 Roye GD, Monchik J, Amaral JF (2000) Endoscopic adrenalectomy using ultrasonic cutting and coagulating. Surg Technol Int IX:129–138
7.
go back to reference Contin P, Goossen K, Grummich K et al (2013) ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery—the ENERCON systematic review and network meta-analysis. Langenbecks Arch Surg 398(8):1039–1056. doi:10.1007/s00423-013-1137-7 CrossRefPubMed Contin P, Goossen K, Grummich K et al (2013) ENERgized vessel sealing systems versus CONventional hemostasis techniques in thyroid surgery—the ENERCON systematic review and network meta-analysis. Langenbecks Arch Surg 398(8):1039–1056. doi:10.​1007/​s00423-013-1137-7 CrossRefPubMed
12.
14.
go back to reference Brooks SP, Gelman A (1998) General methods for monitoring convergence of iterative simulations. J Comput Graph Stat 7(4):434–455 Brooks SP, Gelman A (1998) General methods for monitoring convergence of iterative simulations. J Comput Graph Stat 7(4):434–455
15.
go back to reference Lu G, Ades AE (2006) Assessing evidence inconsistency in mixed treatment comparisons. J Am Stat Assoc 101:447–459CrossRef Lu G, Ades AE (2006) Assessing evidence inconsistency in mixed treatment comparisons. J Am Stat Assoc 101:447–459CrossRef
16.
go back to reference Dias S, Welton NJ, Ades AE (2010) Checking consistency in mixed treatment comparison meta-analysis. Stat Med 29:932–944CrossRefPubMed Dias S, Welton NJ, Ades AE (2010) Checking consistency in mixed treatment comparison meta-analysis. Stat Med 29:932–944CrossRefPubMed
17.
go back to reference van Valkenhoef G, Tervonen T, Zwinkels T et al (2013) ADDIS: a decision support system for evidence-based medicine. Decis Support Syst 55:447–459 van Valkenhoef G, Tervonen T, Zwinkels T et al (2013) ADDIS: a decision support system for evidence-based medicine. Decis Support Syst 55:447–459
22.
go back to reference Zanghi A, Cavallaro A, Di Vita M et al (2014) The safety of the Harmonic(R) FOCUS in open thyroidectomy: a prospective, randomized study comparing the Harmonic(R) FOCUS and traditional suture ligation (knot and tie) technique. Int J Surg 12(Suppl 1):S132–S135. doi:10.1016/j.ijsu.2014.05.028 CrossRefPubMed Zanghi A, Cavallaro A, Di Vita M et al (2014) The safety of the Harmonic(R) FOCUS in open thyroidectomy: a prospective, randomized study comparing the Harmonic(R) FOCUS and traditional suture ligation (knot and tie) technique. Int J Surg 12(Suppl 1):S132–S135. doi:10.​1016/​j.​ijsu.​2014.​05.​028 CrossRefPubMed
25.
go back to reference Docimo G, Ruggiero R, Gubitosi A et al (2012) Ultrasound scalpel in thyroidectomy. Prospective randomized study. Ann Ital Chir 83(6):491–496PubMed Docimo G, Ruggiero R, Gubitosi A et al (2012) Ultrasound scalpel in thyroidectomy. Prospective randomized study. Ann Ital Chir 83(6):491–496PubMed
26.
go back to reference Konturek A, Barczynski M, Stopa M et al (2012) Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears - a prospective randomized study. Wideochir Inne Tech Maloinwazyjne 7(4):268–274. doi:10.5114/wiitm.2011.30675 PubMedPubMedCentral Konturek A, Barczynski M, Stopa M et al (2012) Total thyroidectomy for non-toxic multinodular goiter with versus without the use of harmonic FOCUS dissecting shears - a prospective randomized study. Wideochir Inne Tech Maloinwazyjne 7(4):268–274. doi:10.​5114/​wiitm.​2011.​30675 PubMedPubMedCentral
28.
go back to reference Sista F, Schietroma M, Ruscitti C et al (2012) New ultrasonic dissector versus conventional hemostasis in thyroid surgery: a randomized prospective study. J Laparoendosc Adv Surg Tech A 22(3):220–224. doi:10.1089/lap.2011.0266 CrossRefPubMed Sista F, Schietroma M, Ruscitti C et al (2012) New ultrasonic dissector versus conventional hemostasis in thyroid surgery: a randomized prospective study. J Laparoendosc Adv Surg Tech A 22(3):220–224. doi:10.​1089/​lap.​2011.​0266 CrossRefPubMed
34.
go back to reference Papavramidis TS, Sapalidis K, Michalopoulos N et al (2010) UltraCision harmonic scalpel versus clamp-and-tie total thyroidectomy: a clinical trial. Head Neck 32(6):723–727. doi:10.1002/hed.21240 PubMed Papavramidis TS, Sapalidis K, Michalopoulos N et al (2010) UltraCision harmonic scalpel versus clamp-and-tie total thyroidectomy: a clinical trial. Head Neck 32(6):723–727. doi:10.​1002/​hed.​21240 PubMed
38.
go back to reference Basoglu M, Ozturk G, Atamanalp SS et al (2008) The use of harmonic scalpels in thyroidectomies: clinical experiences. Eurasian J Med 40(2):75–78PubMedPubMedCentral Basoglu M, Ozturk G, Atamanalp SS et al (2008) The use of harmonic scalpels in thyroidectomies: clinical experiences. Eurasian J Med 40(2):75–78PubMedPubMedCentral
39.
go back to reference Hallgrimsson P, Loven L, Westerdahl J et al (2008) Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial. Langenbecks Arch Surg 393(5):675–680. doi:10.1007/s00423-008-0361-z CrossRefPubMed Hallgrimsson P, Loven L, Westerdahl J et al (2008) Use of the harmonic scalpel versus conventional haemostatic techniques in patients with Grave disease undergoing total thyroidectomy: a prospective randomised controlled trial. Langenbecks Arch Surg 393(5):675–680. doi:10.​1007/​s00423-008-0361-z CrossRefPubMed
41.
go back to reference Lombardi CP, Raffaelli M, Cicchetti A et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393(5):627–631. doi:10.1007/s00423-008-0380-9 CrossRefPubMed Lombardi CP, Raffaelli M, Cicchetti A et al (2008) The use of “harmonic scalpel” versus “knot tying” for conventional “open” thyroidectomy: results of a prospective randomized study. Langenbecks Arch Surg 393(5):627–631. doi:10.​1007/​s00423-008-0380-9 CrossRefPubMed
43.
go back to reference Kilic M, Keskek M, Ertan T et al (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638CrossRefPubMed Kilic M, Keskek M, Ertan T et al (2007) A prospective randomized trial comparing the harmonic scalpel with conventional knot tying in thyroidectomy. Adv Ther 24(3):632–638CrossRefPubMed
47.
go back to reference Ortega J, Sala C, Flor B et al (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12. doi:10.1089/109264204322862289 CrossRefPubMed Ortega J, Sala C, Flor B et al (2004) Efficacy and cost-effectiveness of the UltraCision harmonic scalpel in thyroid surgery: an analysis of 200 cases in a randomized trial. J Laparoendosc Adv Surg Tech A 14(1):9–12. doi:10.​1089/​1092642043228622​89 CrossRefPubMed
48.
go back to reference Defechereux T, Rinken F, Maweja S et al (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277CrossRefPubMed Defechereux T, Rinken F, Maweja S et al (2003) Evaluation of the ultrasonic dissector in thyroid surgery. A prospective randomised study. Acta Chir Belg 103(3):274–277CrossRefPubMed
50.
go back to reference Coiro S, Frattaroli FM, De Lucia F et al (2015) A comparison of the outcome using Ligasure small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study. Langenbecks Arch Surg 400(2):247–252. doi:10.1007/s00423-014-1270-y CrossRefPubMed Coiro S, Frattaroli FM, De Lucia F et al (2015) A comparison of the outcome using Ligasure small jaw and clamp-and-tie technique in thyroidectomy: a randomized single center study. Langenbecks Arch Surg 400(2):247–252. doi:10.​1007/​s00423-014-1270-y CrossRefPubMed
51.
go back to reference Molnar C, Voidazan S, Rad CC et al (2014) Total thyroidectomy with LigaSure Small Jaw versus conventional thyroidectomy: a clinical study. Chirurgia (Bucur) 109(5):608–612 Molnar C, Voidazan S, Rad CC et al (2014) Total thyroidectomy with LigaSure Small Jaw versus conventional thyroidectomy: a clinical study. Chirurgia (Bucur) 109(5):608–612
52.
go back to reference Hirunwiwatkul P, Tungkavivachagul S (2013) A multicenter, randomized, controlled clinical trial of LigaSure small jaw vessel sealing system versus conventional technique in thyroidectomy. Eur Arch Otorhinolaryngol 270(7):2109–2114. doi:10.1007/s00405-012-2289-8 CrossRefPubMed Hirunwiwatkul P, Tungkavivachagul S (2013) A multicenter, randomized, controlled clinical trial of LigaSure small jaw vessel sealing system versus conventional technique in thyroidectomy. Eur Arch Otorhinolaryngol 270(7):2109–2114. doi:10.​1007/​s00405-012-2289-8 CrossRefPubMed
54.
go back to reference Scerrino G, Paladino NC, Di Paola V et al (2010) Total thyroidectomy performed with the Starion vessel sealing system versus the conventional technique: a prospective randomized trial. Surg Innov 17(3):242–247. doi:10.1177/1553350610376394 CrossRefPubMed Scerrino G, Paladino NC, Di Paola V et al (2010) Total thyroidectomy performed with the Starion vessel sealing system versus the conventional technique: a prospective randomized trial. Surg Innov 17(3):242–247. doi:10.​1177/​1553350610376394​ CrossRefPubMed
55.
go back to reference Singh P, O’Connell D, Langille M et al (2010) LigaSure versus conventional hemostasis in thyroid surgery: prospective randomized controlled trial. J Otolaryngol Head Neck Surg 39(4):378–384PubMed Singh P, O’Connell D, Langille M et al (2010) LigaSure versus conventional hemostasis in thyroid surgery: prospective randomized controlled trial. J Otolaryngol Head Neck Surg 39(4):378–384PubMed
56.
go back to reference Saint Marc O, Cogliandolo A, Piquard A et al (2007) LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study. Arch Surg 142(2):150–156. doi:10.1001/archsurg.142.2.150 (discussion 157) Saint Marc O, Cogliandolo A, Piquard A et al (2007) LigaSure vs clamp-and-tie technique to achieve hemostasis in total thyroidectomy for benign multinodular goiter: a prospective randomized study. Arch Surg 142(2):150–156. doi:10.​1001/​archsurg.​142.​2.​150 (discussion 157)
58.
go back to reference Manouras A, Lagoudianakis EE, Antonakis PT et al (2005) Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy. Head Neck 27(11):959–962. doi:10.1002/hed.20271 CrossRefPubMed Manouras A, Lagoudianakis EE, Antonakis PT et al (2005) Electrothermal bipolar vessel sealing system is a safe and time-saving alternative to classic suture ligation in total thyroidectomy. Head Neck 27(11):959–962. doi:10.​1002/​hed.​20271 CrossRefPubMed
59.
go back to reference Kwak HY, Chae BJ, Park YG et al (2014) Comparison of surgical outcomes between papillary thyroid cancer patients treated with the Harmonic ACE scalpel and LigaSure Precise instrument during conventional thyroidectomy: a single-blind prospective randomized controlled trial. J Surg Res 187(2):484–489. doi:10.1016/j.jss.2013.11.1093 CrossRefPubMed Kwak HY, Chae BJ, Park YG et al (2014) Comparison of surgical outcomes between papillary thyroid cancer patients treated with the Harmonic ACE scalpel and LigaSure Precise instrument during conventional thyroidectomy: a single-blind prospective randomized controlled trial. J Surg Res 187(2):484–489. doi:10.​1016/​j.​jss.​2013.​11.​1093 CrossRefPubMed
60.
go back to reference Dionigi G, Boni L, Rausei S et al (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure (LF1212) and the Harmonic(R) FOCUS. Langenbecks Arch Surg 397(5):817–823. doi:10.1007/s00423-011-0898-0 CrossRefPubMed Dionigi G, Boni L, Rausei S et al (2012) The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure (LF1212) and the Harmonic(R) FOCUS. Langenbecks Arch Surg 397(5):817–823. doi:10.​1007/​s00423-011-0898-0 CrossRefPubMed
63.
go back to reference Soroush A, Pourbakhtyaran E, Allame S et al (2013) Harmonic scalpel is more secure than conventional methods in total thyroidectomy: a randomized clinical tria. J Minim Invasive Surg Sci 2(3):23–27 Soroush A, Pourbakhtyaran E, Allame S et al (2013) Harmonic scalpel is more secure than conventional methods in total thyroidectomy: a randomized clinical tria. J Minim Invasive Surg Sci 2(3):23–27
66.
go back to reference Revelli L, Damiani G, Bianchi CB et al (2016) Complications in thyroid surgery. Harmonic Scalpel, Harmonic Focus versus Conventional Hemostasis: a meta-analysis. Int J Surg 28 Suppl 1:S22–S32. doi:10.1016/j.ijsu.2015.12.050 Revelli L, Damiani G, Bianchi CB et al (2016) Complications in thyroid surgery. Harmonic Scalpel, Harmonic Focus versus Conventional Hemostasis: a meta-analysis. Int J Surg 28 Suppl 1:S22–S32. doi:10.​1016/​j.​ijsu.​2015.​12.​050
Metadata
Title
A comparison of surgical outcomes and complications between hemostatic devices for thyroid surgery: a network meta-analysis
Authors
Yingwei Luo
Xi Li
Jianwei Dong
Weifeng Sun
Publication date
01-03-2017
Publisher
Springer Berlin Heidelberg
Published in
European Archives of Oto-Rhino-Laryngology / Issue 3/2017
Print ISSN: 0937-4477
Electronic ISSN: 1434-4726
DOI
https://doi.org/10.1007/s00405-016-4190-3

Other articles of this Issue 3/2017

European Archives of Oto-Rhino-Laryngology 3/2017 Go to the issue