Background

Thyroidectomies of hyperthyroidic patients are known to be more blood-spattered than the operations performed for euthyroid nodular diseases and require careful hemostasis. Our purpose was to evaluate the efficacy of the use of LigaSure in patients with hyperthyroidism.

Materials and methods

Between January 2004 and October 2005, 100 patients underwent total or near-total thyroidectomy. Bipolar vessel ligation system (LigaSure) was the choice of modality for hemostasis in half of these patients, and the conventional suture ligation technique was used for the rest. The following data were evaluated non-randomized and prospectively in this study: patients demographics, thyroid pathology, operative duration, presence of complications, and the duration of the hospital stay. Comparisons of the data were evaluated by the Wilcoxon and chi-square tests.

Results

Among the patients of the LigaSure group, 14 patients were detected to have hyperthyroidism (seven patients with Graves’ disease and another seven patients with multinodular toxic goiter), while 36 patients were found to be euthyroidic. The durations of the operation time and of the hospital stay of the patients in the LigaSure group were significantly lower than the conventional thyroidectomy group (p<0.05). The complication rates of the LigaSure and conventional thyroidectomy groups were 4 and 6%, respectively (p>0.05).

Conclusions

The use of LigaSure as an operative technique in the treatment of Graves’ disease and toxic goiter is a safe and effective modality that provides a shorter hospital stay and a shorter operation time as well.
Literature
1.
go back to reference Dilek ON, Yilmaz S, Degirmenci B, Ali Sahin D, Akbulut G, Dilek FH (2005) The use of a vessel sealing system in thyroid surgery. Acta Chir Belg 105(4):369–372PubMed Dilek ON, Yilmaz S, Degirmenci B, Ali Sahin D, Akbulut G, Dilek FH (2005) The use of a vessel sealing system in thyroid surgery. Acta Chir Belg 105(4):369–372PubMed
2.
go back to reference Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29:771–774PubMedCrossRef Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29:771–774PubMedCrossRef
3.
go back to reference Shen WT, Baumbusch MA, Kebebew E, Duh QY (2005) Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. Asian J Surg 28(2):86–89PubMedCrossRef Shen WT, Baumbusch MA, Kebebew E, Duh QY (2005) Use of the electrothermal vessel sealing system versus standard vessel ligation in thyroidectomy. Asian J Surg 28(2):86–89PubMedCrossRef
4.
go back to reference Sosa JA, Bowman HM, Tielsch JM et al (1998) The importance of surgeon experience for clinical and economic outcomes from thyroidectomy. Ann Surg 228:320–330PubMedCrossRef Sosa JA, Bowman HM, Tielsch JM et al (1998) The importance of surgeon experience for clinical and economic outcomes from thyroidectomy. Ann Surg 228:320–330PubMedCrossRef
5.
go back to reference Landman J, Kerbl K, Rehman J et al (2003) Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 169:697–700PubMedCrossRef Landman J, Kerbl K, Rehman J et al (2003) Evaluation of a vessel sealing system, bipolar electrosurgery, harmonic scalpel, titanium clips, endoscopic gastrointestinal anastomosis vascular staples and sutures for arterial and venous ligation in a porcine model. J Urol 169:697–700PubMedCrossRef
6.
go back to reference Matthews BD, Pratt BL, Backus CL et al (2001) Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis. Am Surg 67:901–906PubMed Matthews BD, Pratt BL, Backus CL et al (2001) Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis. Am Surg 67:901–906PubMed
7.
go back to reference Jayne DG, Botterill I, Ambrose NS et al (2002) Randomized clinical trial of Ligasure_ versus conventional diathermy for day-case haemorrhoidectomy. Br J Surg 89:428–432PubMedCrossRef Jayne DG, Botterill I, Ambrose NS et al (2002) Randomized clinical trial of Ligasure_ versus conventional diathermy for day-case haemorrhoidectomy. Br J Surg 89:428–432PubMedCrossRef
8.
go back to reference Sandonato L, Cipolla C, Gracefta G et al (2003) Bipolar electrothermic coagulation (Ligasure bipolar vessel sealing system) in thyroid surgery. Chir Ital 55:411–415PubMed Sandonato L, Cipolla C, Gracefta G et al (2003) Bipolar electrothermic coagulation (Ligasure bipolar vessel sealing system) in thyroid surgery. Chir Ital 55:411–415PubMed
9.
go back to reference Levy B, Emery L (2003) Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy.Obstet Gynecol 102:147–151PubMedCrossRef Levy B, Emery L (2003) Randomized trial of suture versus electrosurgical bipolar vessel sealing in vaginal hysterectomy.Obstet Gynecol 102:147–151PubMedCrossRef
10.
go back to reference Lee WJ, Chen TC, Lai IR et al (2003) Randomized clinical trial of LigaSure trade mark versus conventional surgery for extended gastric cancer resection. Br J Surg 90:1493–1496PubMedCrossRef Lee WJ, Chen TC, Lai IR et al (2003) Randomized clinical trial of LigaSure trade mark versus conventional surgery for extended gastric cancer resection. Br J Surg 90:1493–1496PubMedCrossRef
11.
go back to reference Dror A, Salim M, Yoseph R (2003) How I do it: sutureless thyroidectomy using electrothermal system; a new technique. J Laryngol Otol 17:198–201 Dror A, Salim M, Yoseph R (2003) How I do it: sutureless thyroidectomy using electrothermal system; a new technique. J Laryngol Otol 17:198–201
12.
go back to reference Heniford BT, Matthews BD, Sing RF et al (2001) Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 15(8):799–801, (Grade B)PubMedCrossRef Heniford BT, Matthews BD, Sing RF et al (2001) Initial results with an electrothermal bipolar vessel sealer. Surg Endosc 15(8):799–801, (Grade B)PubMedCrossRef
13.
go back to reference Kennedy JS, Stranahan PL, Taylor KD et al (1998) High-burststrength, feedback-controlled bipolar vessel sealing. Surg Endosc 12:876–878, (Grade B)PubMedCrossRef Kennedy JS, Stranahan PL, Taylor KD et al (1998) High-burststrength, feedback-controlled bipolar vessel sealing. Surg Endosc 12:876–878, (Grade B)PubMedCrossRef
14.
go back to reference Lachanas VA, Prokopakis EP, Mpenakis AA et al (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngology Head Neck Surg 132(3):487–489CrossRef Lachanas VA, Prokopakis EP, Mpenakis AA et al (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngology Head Neck Surg 132(3):487–489CrossRef
15.
go back to reference Siperstein AE, Berber E, Morkoyun E (2002) The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 137:137–142PubMedCrossRef Siperstein AE, Berber E, Morkoyun E (2002) The use of the harmonic scalpel vs conventional knot tying for vessel ligation in thyroid surgery. Arch Surg 137:137–142PubMedCrossRef
16.
go back to reference Harold KL, Pollinger H, Matthews BD et al (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17(8):1228–1230, (Grade B)PubMedCrossRef Harold KL, Pollinger H, Matthews BD et al (2003) Comparison of ultrasonic energy, bipolar thermal energy, and vascular clips for the hemostasis of small-, medium-, and large-sized arteries. Surg Endosc 17(8):1228–1230, (Grade B)PubMedCrossRef
17.
go back to reference Dubuc-Lissoir J (2003) Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery. Surg Endosc 17(3):466–468, (Grade C)PubMedCrossRef Dubuc-Lissoir J (2003) Use of a new energy-based vessel ligation device during laparoscopic gynecologic oncologic surgery. Surg Endosc 17(3):466–468, (Grade C)PubMedCrossRef
18.
go back to reference Belli G, Fantini C, Ciciliano F et al (2003) Pancreaticoduodenectomy in portal hypertension: use of the Ligasure. J Hepatobiliary Pancreat Surg 10(3):215–217, (Grade B)PubMedCrossRef Belli G, Fantini C, Ciciliano F et al (2003) Pancreaticoduodenectomy in portal hypertension: use of the Ligasure. J Hepatobiliary Pancreat Surg 10(3):215–217, (Grade B)PubMedCrossRef
19.
go back to reference Parmeggiani U, Avenia N, De Falco M, Parmeggiani D, Pisaniello D, d’Ajello M (2005) Major complications in thyroid surgery: utility of bipolar vessel sealing (Ligasure Precise). G Chir 26(10):387–394PubMed Parmeggiani U, Avenia N, De Falco M, Parmeggiani D, Pisaniello D, d’Ajello M (2005) Major complications in thyroid surgery: utility of bipolar vessel sealing (Ligasure Precise). G Chir 26(10):387–394PubMed
20.
go back to reference Matthews BD, Pratt BL, Backus CL et al (2001) Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis. Am Surg 67(9):901–906, (Grade B)PubMed Matthews BD, Pratt BL, Backus CL et al (2001) Effectiveness of the ultrasonic coagulating shears, LigaSure vessel sealer, and surgical clip application in biliary surgery: a comparative analysis. Am Surg 67(9):901–906, (Grade B)PubMed
Metadata
Title
The use of LigaSure in patients with hyperthyroidism
Authors
Umut Barbaros
Yeşim Erbil
Alp Bozbora
Uğur Deveci
Nihat Aksakal
Ahmet Dinççağ
Selçuk Özarmağan
Publication date
01-11-2006
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 6/2006
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-006-0082-0

Other articles of this Issue 6/2006

Langenbeck's Archives of Surgery 6/2006 Go to the issue