Skip to main content
Top
Published in: Langenbeck's Archives of Surgery 5/2012

01-06-2012 | Rapid Communication

The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS

Authors: Gianlorenzo Dionigi, Luigi Boni, Stefano Rausei, Francesco Frattini, Cesare Carlo Ferrari, Alberto Mangano, Andrea Leotta, Marco Franchin

Published in: Langenbeck's Archives of Surgery | Issue 5/2012

Login to get access

Abstract

Purpose

The options for haemostasis and dissection during modern thyroid surgery include the use of a bipolar vessel sealing system and ultrasonic technology. The aim of this study was to compare these energy-based devices (EBDs) with respect to their use in open thyroidectomy.

Methods

The FOCUS Shear (F) and LigaSure LF1212 (L) were evaluated. A total of 182 consecutive patients scheduled for open thyroidectomy were prospectively randomised into two similarly sized groups. The parameters of operative time, morbidity, incision length, postoperative pain and hospital stay were analysed.

Results

The main clinically primary endpoints of the two devices were identical in the study as the rate of nerve lesions, bleeding, drainage, operative time and postoperative calcium concentration with no significant differences with respect to the instrument utilised. The mean length of the incision was greater in the F group (p < 0.05). Patients in the F group were more likely to complain of pain while swallowing (p < 0.001). Early postoperative measurements of intact parathyroid hormone plasma levels revealed that although the levels were within the reference range, they were significantly lower in the F group (p < 0.001). Oral calcium supplementation was significantly higher and more prolonged in the F group.

Conclusions

The present study demonstrated no significant difference in the rates of postoperative morbidity associated with these two different EBDs used. Differences in clinically less significant were founded and focused on.
Literature
1.
go back to reference Dionigi G, Bacuzzi A, Boni L, Rovera F, Piantanida E, Tanda ML, Diurni M, Carcano G, Luigi B, Cuffari S, Dionigi R (2005) Influence of new technologies on thyroid surgery: state of the art. Expert Rev Med Devices 2(5):547–557PubMedCrossRef Dionigi G, Bacuzzi A, Boni L, Rovera F, Piantanida E, Tanda ML, Diurni M, Carcano G, Luigi B, Cuffari S, Dionigi R (2005) Influence of new technologies on thyroid surgery: state of the art. Expert Rev Med Devices 2(5):547–557PubMedCrossRef
2.
go back to reference Dralle H (2006) Impact of modern technologies on quality of thyroid surgery. Langenbecks Arch Surg 391(1):1–3PubMedCrossRef Dralle H (2006) Impact of modern technologies on quality of thyroid surgery. Langenbecks Arch Surg 391(1):1–3PubMedCrossRef
3.
go back to reference Dionigi G, Boni L, Rovera F, Dionigi R (2006) Thyroid surgery: new approach to dissection and hemostasis. Surg Technol Int 15:75–80PubMed Dionigi G, Boni L, Rovera F, Dionigi R (2006) Thyroid surgery: new approach to dissection and hemostasis. Surg Technol Int 15:75–80PubMed
4.
go back to reference Dionigi G (2009) Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbecks Arch Surg 94(3):579–580CrossRef Dionigi G (2009) Energy based devices and recurrent laryngeal nerve injury: the need for safer instruments. Langenbecks Arch Surg 94(3):579–580CrossRef
5.
go back to reference Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740PubMedCrossRef Miccoli P, Materazzi G, Miccoli M, Frustaci G, Fosso A, Berti P (2010) Evaluation of a new ultrasonic device in thyroid surgery: comparative randomized study. Am J Surg 199(6):736–740PubMedCrossRef
6.
go back to reference Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinccag A, Ozarmagan S (2006) The use of LigaSure in patients with hyperthyroidism. Langenbecks Arch Surg 391(6):575–579PubMedCrossRef Barbaros U, Erbil Y, Bozbora A, Deveci U, Aksakal N, Dinccag A, Ozarmagan S (2006) The use of LigaSure in patients with hyperthyroidism. Langenbecks Arch Surg 391(6):575–579PubMedCrossRef
7.
go back to reference Franko J, Kish KJ, Pezzi CM, Pak H, Kukora JS (2006) Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique. Am Surg 72(2):132–136PubMed Franko J, Kish KJ, Pezzi CM, Pak H, Kukora JS (2006) Safely increasing the efficiency of thyroidectomy using a new bipolar electrosealing device (LigaSure) versus conventional clamp-and-tie technique. Am Surg 72(2):132–136PubMed
8.
go back to reference Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29(6):771–774PubMedCrossRef Kirdak T, Korun N, Ozguc H (2005) Use of ligasure in thyroidectomy procedures: results of a prospective comparative study. World J Surg 29(6):771–774PubMedCrossRef
9.
go back to reference Musunuru S, Schaefer S, Chen H (2008) The use of the Ligasure for hemostasis during thyroid lobectomy. Am J Surg 195(3):382–384, discussion 4-5PubMedCrossRef Musunuru S, Schaefer S, Chen H (2008) The use of the Ligasure for hemostasis during thyroid lobectomy. Am J Surg 195(3):382–384, discussion 4-5PubMedCrossRef
10.
go back to reference Lachanas VA, Prokopakis EP, Mpenakis AA, Karatzanis AD, Velegrakis GA (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngol Head Neck Surg 132(3):487–489PubMedCrossRef Lachanas VA, Prokopakis EP, Mpenakis AA, Karatzanis AD, Velegrakis GA (2005) The use of Ligasure Vessel Sealing System in thyroid surgery. Otolaryngol Head Neck Surg 132(3):487–489PubMedCrossRef
11.
go back to reference Miccoli P, Berti P, Dionigi G, D'Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef Miccoli P, Berti P, Dionigi G, D'Agostino J, Orlandini C, Donatini G (2006) Randomized controlled trial of harmonic scalpel use during thyroidectomy. Arch Otolaryngol Head Neck Surg 132(10):1069–1073PubMedCrossRef
12.
go back to reference Campbell PA, Cresswell AB, Frank TG, Cuschieri A (2003) Real-time thermography during energized vessel sealing and dissection. Surg Endosc 17(10):1640–1645PubMedCrossRef Campbell PA, Cresswell AB, Frank TG, Cuschieri A (2003) Real-time thermography during energized vessel sealing and dissection. Surg Endosc 17(10):1640–1645PubMedCrossRef
13.
go back to reference Emam TA, Cuschieri A (2003) How safe is high-power ultrasonic dissection? Ann Surg 237(2):186–191PubMed Emam TA, Cuschieri A (2003) How safe is high-power ultrasonic dissection? Ann Surg 237(2):186–191PubMed
14.
go back to reference Smith CT, Zarebczan B, Alhefdhi A, Chen H (2011) Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma. J Surg Res 170(1):64–68PubMedCrossRef Smith CT, Zarebczan B, Alhefdhi A, Chen H (2011) Infrared thermographic profiles of vessel sealing devices on thyroid parenchyma. J Surg Res 170(1):64–68PubMedCrossRef
15.
go back to reference Dionigi G, Boni L, Rovera F, Rausei S, Castelnuovo P, Dionigi R (2010) Postoperative laryngoscopy in thyroid surgery: proper timing to detect recurrent laryngeal nerve injury. Langenbecks Arch Surg 395(4):327–331PubMedCrossRef Dionigi G, Boni L, Rovera F, Rausei S, Castelnuovo P, Dionigi R (2010) Postoperative laryngoscopy in thyroid surgery: proper timing to detect recurrent laryngeal nerve injury. Langenbecks Arch Surg 395(4):327–331PubMedCrossRef
16.
go back to reference Barczyński M, Cichoń S, Konturek A, Cichoń W (2008) Applicability of intraoperative parathyroid hormone assay during total thyroidectomy as a guide for the surgeon to selective parathyroid tissue autotransplantation. World J Surg 32(5):822–828PubMedCrossRef Barczyński M, Cichoń S, Konturek A, Cichoń W (2008) Applicability of intraoperative parathyroid hormone assay during total thyroidectomy as a guide for the surgeon to selective parathyroid tissue autotransplantation. World J Surg 32(5):822–828PubMedCrossRef
17.
go back to reference Barczyński M, Cichoń S, Konturek A (2007) Which criterion of intraoperative iPTH assay is the most accurate in prediction of true serum calcium levels after thyroid surgery? Langenbecks Arch Surg 392(6):693–698PubMedCrossRef Barczyński M, Cichoń S, Konturek A (2007) Which criterion of intraoperative iPTH assay is the most accurate in prediction of true serum calcium levels after thyroid surgery? Langenbecks Arch Surg 392(6):693–698PubMedCrossRef
18.
go back to reference Dionigi G, Barczynski M, Chiang FY, Dralle H, Duran-Poveda M, Iacobone M, Lombardi CP, Materazzi G, Mihai R, Randolph GW, Sitges-Serra A (2010) Why monitor the recurrent laryngeal nerve in thyroid surgery? J Endocrinol Invest 33(11):819–822PubMed Dionigi G, Barczynski M, Chiang FY, Dralle H, Duran-Poveda M, Iacobone M, Lombardi CP, Materazzi G, Mihai R, Randolph GW, Sitges-Serra A (2010) Why monitor the recurrent laryngeal nerve in thyroid surgery? J Endocrinol Invest 33(11):819–822PubMed
19.
go back to reference Curfman GD, Redberg RF (2011) Medical devices—balancing regulation and innovation. N Engl J Med 365(11):975–977PubMedCrossRef Curfman GD, Redberg RF (2011) Medical devices—balancing regulation and innovation. N Engl J Med 365(11):975–977PubMedCrossRef
Metadata
Title
The safety of energy-based devices in open thyroidectomy: a prospective, randomised study comparing the LigaSure™ (LF1212) and the Harmonic® FOCUS
Authors
Gianlorenzo Dionigi
Luigi Boni
Stefano Rausei
Francesco Frattini
Cesare Carlo Ferrari
Alberto Mangano
Andrea Leotta
Marco Franchin
Publication date
01-06-2012
Publisher
Springer-Verlag
Published in
Langenbeck's Archives of Surgery / Issue 5/2012
Print ISSN: 1435-2443
Electronic ISSN: 1435-2451
DOI
https://doi.org/10.1007/s00423-011-0898-0

Other articles of this Issue 5/2012

Langenbeck's Archives of Surgery 5/2012 Go to the issue