Skip to main content
Top
Published in: Journal of NeuroEngineering and Rehabilitation 1/2020

Open Access 01-12-2020 | Tremor | Research

Design of a lightweight passive orthosis for tremor suppression

Authors: Nicolas Philip Fromme, Martin Camenzind, Robert Riener, René M. Rossi

Published in: Journal of NeuroEngineering and Rehabilitation | Issue 1/2020

Login to get access

Abstract

Background

Tremor is the most common movement disorder with the highest prevalence in the upper limbs. The mechanical suppression of involuntary movements is an alternative and additional treatment to medication or surgery. Here we present a new, soft, lightweight, task asjustable and passive orthosis for tremor suppression.

Methods

A new concept of a manual, textile-based, passive orthosis was designed with an integrated, task adjustable, air-filled structure, which can easily be inflated or deflated on-demand for a certain daily activity. The air-filled structure is placed on the dorsal side of the wrist and gets bent and compressed by movements when inflated. In a constant volume air-filled structure, air pressure increases while it is inflating, creating a counterforce to the compression caused by bending. We characterised the air-filled structure stiffness by measuring the reaction torque as a function of the angle of deflection on a test bench. Furthermore, we evaluated the efficacy of the developed passive soft orthosis by analysing the suppression of involuntary movements in the wrist of a tremor-affected patient during different activities of daily living (i.e. by calculating the power spectral densities of acceleration).

Results

By putting special emphasis on the comfort and wearability of the orthosis, we achieved a lightweight design (33 g). The measurements of the angular deflection and resulting reaction torques show non-linear, hysteretic, behaviour, as well as linear behaviour with a coefficient of determination (R2) between 0.95 and 0.99. Furthermore, we demonstrated that the soft orthosis significantly reduces tremor power for daily living activities, such as drinking from a cup, pouring water and drawing a spiral, by 74 to 82% (p = 0.03); confirmed by subjective tremor-reducing perception by the patient.

Conclusion

The orthosis we developed is a lightweight and unobtrusive assistive technology, which suppresses involuntary movements and shows high wearability properties, with the potential to be comfortable. This air-structure technology could also be applied to other movement disorders, like spasticity, or even be integrated into future exoskeletons and exosuits for the implementation of variable stiffness in the systems.
Literature
1.
go back to reference Deuschl G, Bain P, Brin M. Consensus statement of the Movement Disorder Society on tremor. Mov Disord. 1998;13(S3):2–23.PubMedCrossRef Deuschl G, Bain P, Brin M. Consensus statement of the Movement Disorder Society on tremor. Mov Disord. 1998;13(S3):2–23.PubMedCrossRef
2.
go back to reference Elble R, Bain P, João Forjaz M, Haubenberger D, Testa C, Goetz CG, et al. Task force report: scales for screening and evaluating tremor: critique and recommendations. Mov Disord. 2013;28(13):1793–800.PubMedCrossRef Elble R, Bain P, João Forjaz M, Haubenberger D, Testa C, Goetz CG, et al. Task force report: scales for screening and evaluating tremor: critique and recommendations. Mov Disord. 2013;28(13):1793–800.PubMedCrossRef
4.
go back to reference Ellrichmann G. Vorkommen und Wertigkeit von Oberfrequenzen in der 24-Stunden-Elektromyographie und Accelerometrie. Doctoral dissertation: Ruhr University Bochum; 2007. Ellrichmann G. Vorkommen und Wertigkeit von Oberfrequenzen in der 24-Stunden-Elektromyographie und Accelerometrie. Doctoral dissertation: Ruhr University Bochum; 2007.
5.
go back to reference Raethjen J, Lindemann M, Schmajohann H, Wenzelburger R, Pfister G, Deuschl G. Multiple oscillators are causing parkinsonian and essential tremor. Mov Disord. 2000;15(1):84–94.PubMedCrossRef Raethjen J, Lindemann M, Schmajohann H, Wenzelburger R, Pfister G, Deuschl G. Multiple oscillators are causing parkinsonian and essential tremor. Mov Disord. 2000;15(1):84–94.PubMedCrossRef
6.
go back to reference Lopez-de-Ipiña K, Bergareche A, de la Riva P, Faundez-Zanuy M, Calvo PM, Roure J, et al. Automatic non-linear analysis of non-invasive writing signals, applied to essential tremor. J Appl Log. 2014;16:50–9.CrossRef Lopez-de-Ipiña K, Bergareche A, de la Riva P, Faundez-Zanuy M, Calvo PM, Roure J, et al. Automatic non-linear analysis of non-invasive writing signals, applied to essential tremor. J Appl Log. 2014;16:50–9.CrossRef
7.
go back to reference Bhatia KP, Bain P, Bajaj N, Elble RJ, Hallett M, Louis ED, et al. Consensus statement on the classification of tremors. From the task force on tremor of the International Parkinson and Movement Disorder Society. Mov Disord. 2018;33(1):75–87.PubMedCrossRef Bhatia KP, Bain P, Bajaj N, Elble RJ, Hallett M, Louis ED, et al. Consensus statement on the classification of tremors. From the task force on tremor of the International Parkinson and Movement Disorder Society. Mov Disord. 2018;33(1):75–87.PubMedCrossRef
8.
go back to reference de Rijk MC, Breteler MM, Graveland GA, Ott A, Grobbee DE, van der Meché FG, et al. Prevalence of Parkinson’s disease in the elderly: the Rotterdam study. Neurology. 1995;45(12):2143–6.PubMedCrossRef de Rijk MC, Breteler MM, Graveland GA, Ott A, Grobbee DE, van der Meché FG, et al. Prevalence of Parkinson’s disease in the elderly: the Rotterdam study. Neurology. 1995;45(12):2143–6.PubMedCrossRef
9.
go back to reference Louis ED, Ferreira JJ. How common is the most common adult movement disorder? Update on the worldwide prevalence of essential tremor. Mov Disord. 2010;25(5):534–41.PubMedCrossRef Louis ED, Ferreira JJ. How common is the most common adult movement disorder? Update on the worldwide prevalence of essential tremor. Mov Disord. 2010;25(5):534–41.PubMedCrossRef
10.
go back to reference Louis ED, Ottman R. How many people in the USA have essential tremor? Deriving a population estimate based on epidemiological data. Tremor Other Hyperkinet Mov (N Y). 2014;4:259. Louis ED, Ottman R. How many people in the USA have essential tremor? Deriving a population estimate based on epidemiological data. Tremor Other Hyperkinet Mov (N Y). 2014;4:259.
11.
go back to reference Grimaldi G, Manto M. “Old” and emerging therapies of human tremor. Clin Med Insights Ther. 2010;2:CMT:S2999.CrossRef Grimaldi G, Manto M. “Old” and emerging therapies of human tremor. Clin Med Insights Ther. 2010;2:CMT:S2999.CrossRef
12.
go back to reference Miller KM, Okun MS, Fernandez HF, Jacobson CE IV, Rodriguez RL, Bowers D. Depression symptoms in movement disorders: comparing Parkinson’s disease, dystonia, and essential tremor. Mov Disord. 2007;22(5):666–72.PubMedCrossRef Miller KM, Okun MS, Fernandez HF, Jacobson CE IV, Rodriguez RL, Bowers D. Depression symptoms in movement disorders: comparing Parkinson’s disease, dystonia, and essential tremor. Mov Disord. 2007;22(5):666–72.PubMedCrossRef
13.
go back to reference Ruonala V, Meigal A, Rissanen SM, Airaksinen O, Kankaanpää M, Karjalainen PA. EMG signal morphology and kinematic parameters in essential tremor and Parkinson’s disease patients. J Electromyogr Kinesiol. 2014;24(2):300–6.PubMedCrossRef Ruonala V, Meigal A, Rissanen SM, Airaksinen O, Kankaanpää M, Karjalainen PA. EMG signal morphology and kinematic parameters in essential tremor and Parkinson’s disease patients. J Electromyogr Kinesiol. 2014;24(2):300–6.PubMedCrossRef
14.
go back to reference O’Connor RJ, Kini MU. Non-pharmacological and non-surgical interventions for tremor: a systematic review. Park Relat Disord. 2011;17(7):509–15.CrossRef O’Connor RJ, Kini MU. Non-pharmacological and non-surgical interventions for tremor: a systematic review. Park Relat Disord. 2011;17(7):509–15.CrossRef
15.
go back to reference Diaz NL, Louis ED. Survey of medication usage patterns among essential tremor patients: movement disorder specialists vs. general neurologists. Park Relat Disord. 2010;16(9):604–7.CrossRef Diaz NL, Louis ED. Survey of medication usage patterns among essential tremor patients: movement disorder specialists vs. general neurologists. Park Relat Disord. 2010;16(9):604–7.CrossRef
16.
go back to reference Chang JW, Park CK, Lipsman N, Schwartz ML, Ghanouni P, Henderson JM, et al. A prospective trial of magnetic resonance–guided focused ultrasound thalamotomy for essential tremor: results at the 2-year follow-up. Ann Neurol. 2018;83(1):107–14.PubMedCrossRef Chang JW, Park CK, Lipsman N, Schwartz ML, Ghanouni P, Henderson JM, et al. A prospective trial of magnetic resonance–guided focused ultrasound thalamotomy for essential tremor: results at the 2-year follow-up. Ann Neurol. 2018;83(1):107–14.PubMedCrossRef
17.
go back to reference Raju SS, Niranjan A, Monaco EA, Flickinger JC, Lunsford LD. Stereotactic radiosurgery for medically refractory multiple sclerosis–related tremor. J Neurosurg. 2018;128(4):1214–21.PubMedCrossRef Raju SS, Niranjan A, Monaco EA, Flickinger JC, Lunsford LD. Stereotactic radiosurgery for medically refractory multiple sclerosis–related tremor. J Neurosurg. 2018;128(4):1214–21.PubMedCrossRef
18.
go back to reference Velasco F, Esqueda-Liquidano M, Velasco AL, García-Gomar MG. Prelemniscal lesion for selective improvement of Parkinson disease tremor. Stereotact Funct Neurosurg. 2018;96(1):54–9.PubMedCrossRef Velasco F, Esqueda-Liquidano M, Velasco AL, García-Gomar MG. Prelemniscal lesion for selective improvement of Parkinson disease tremor. Stereotact Funct Neurosurg. 2018;96(1):54–9.PubMedCrossRef
19.
go back to reference Fromme NP, Camenzind M, Riener R, Rossi RM. Need for mechanically and ergonomically enhanced tremor-suppression orthoses for the upper limb: a systematic review. J Neuroeng Rehabil. 2019;16(1):93.PubMedPubMedCentralCrossRef Fromme NP, Camenzind M, Riener R, Rossi RM. Need for mechanically and ergonomically enhanced tremor-suppression orthoses for the upper limb: a systematic review. J Neuroeng Rehabil. 2019;16(1):93.PubMedPubMedCentralCrossRef
20.
go back to reference Rocon E, Gallego JÁ, Belda-Lois JM, Benito-León J, Luis PJ. Biomechanical loading as an alternative treatment for tremor: a review of two approaches. Tremor Other Hyperkinet Mov. 2012;2:1–13. Rocon E, Gallego JÁ, Belda-Lois JM, Benito-León J, Luis PJ. Biomechanical loading as an alternative treatment for tremor: a review of two approaches. Tremor Other Hyperkinet Mov. 2012;2:1–13.
21.
go back to reference Rocon E, Gallego JA, Belda-Lois JM, Pons JL. Assistive robotics as alternative treatment for tremor. In: Sanfeliu A, Ferre M, Armada MA, editors. Advances in Intelligent Systems and Computing, vol. 252: Springer Verlag; 2014. p. 173–9. Rocon E, Gallego JA, Belda-Lois JM, Pons JL. Assistive robotics as alternative treatment for tremor. In: Sanfeliu A, Ferre M, Armada MA, editors. Advances in Intelligent Systems and Computing, vol. 252: Springer Verlag; 2014. p. 173–9.
22.
go back to reference Takanokura M, Sugahara R, Miyake N, Ishiguro K, Muto T, Sakamoto K. Upper-limb orthoses implemented with air dashpots for suppression of pathological tremor in daily activites. In: ISB Conference July 2011. Brussel: Free University of Brussels; 2011. p. 3–4. Takanokura M, Sugahara R, Miyake N, Ishiguro K, Muto T, Sakamoto K. Upper-limb orthoses implemented with air dashpots for suppression of pathological tremor in daily activites. In: ISB Conference July 2011. Brussel: Free University of Brussels; 2011. p. 3–4.
23.
go back to reference Katz R, Buki E, Zacksenhouse M. Attenuating tremor using passive devices. In: Studies in Health Technology and Informatics, vol. 242: IOS Press; 2017. p. 741–7. Katz R, Buki E, Zacksenhouse M. Attenuating tremor using passive devices. In: Studies in Health Technology and Informatics, vol. 242: IOS Press; 2017. p. 741–7.
24.
go back to reference Buki E, Katz R, Zacksenhouse M, Schlesinger I. Vib-bracelet: a passive absorber for attenuating forearm tremor. Med Biol Eng Comput. 2018;56(5):923–30.PubMedCrossRef Buki E, Katz R, Zacksenhouse M, Schlesinger I. Vib-bracelet: a passive absorber for attenuating forearm tremor. Med Biol Eng Comput. 2018;56(5):923–30.PubMedCrossRef
25.
go back to reference Chu CY, Patterson RM. Soft robotic devices for hand rehabilitation and assistance: a narrative review. J Neuroeng Rehabil. 2018;15(1):1–14.CrossRef Chu CY, Patterson RM. Soft robotic devices for hand rehabilitation and assistance: a narrative review. J Neuroeng Rehabil. 2018;15(1):1–14.CrossRef
26.
go back to reference Elble RJ, Moody C, Higgins C. Primary writing tremor. A form of focal dystonia? Mov Disord. 1990;5(2):118–26.PubMedCrossRef Elble RJ, Moody C, Higgins C. Primary writing tremor. A form of focal dystonia? Mov Disord. 1990;5(2):118–26.PubMedCrossRef
27.
go back to reference Kalaiarasi A, Kumar LA. Sensor based portable tremor suppression device for stroke patients. Acupunct Electro Therapeutics Res. 2018;43(1):29–37.CrossRef Kalaiarasi A, Kumar LA. Sensor based portable tremor suppression device for stroke patients. Acupunct Electro Therapeutics Res. 2018;43(1):29–37.CrossRef
28.
go back to reference Rossi R. Comfort and thermoregulatory requirements in cold weather clothing. In: Textiles for Cold Weather Apparel: Woodhead Publishing Limited; 2009. p. 3–18. Rossi R. Comfort and thermoregulatory requirements in cold weather clothing. In: Textiles for Cold Weather Apparel: Woodhead Publishing Limited; 2009. p. 3–18.
29.
30.
go back to reference Motlogelwa S. Comfort and durability in high-performance clothing. High-Performance Appar. 2018:209–19. Motlogelwa S. Comfort and durability in high-performance clothing. High-Performance Appar. 2018:209–19.
31.
go back to reference Fauland G, Lenz A, Rohrer C, Bechtold T. Assessment of moisture management performance of multilayer compression bandages. Text Res J. 2013;83(8):871–80.CrossRef Fauland G, Lenz A, Rohrer C, Bechtold T. Assessment of moisture management performance of multilayer compression bandages. Text Res J. 2013;83(8):871–80.CrossRef
32.
go back to reference Bartels VT, Umbach KH. Medizinische bandagen: physiologisches anforderungsprofil und optimierung des tragekomforts. ORTHOPADIE Tech. 2001;52(2):86–95. Bartels VT, Umbach KH. Medizinische bandagen: physiologisches anforderungsprofil und optimierung des tragekomforts. ORTHOPADIE Tech. 2001;52(2):86–95.
33.
go back to reference International Organization for Standardization. ISO 11092:2014 - Textilien – Physiologische Wirkungen – Messung des Wärme- und Wasserdampfdurchgangswiderstands unter stationären Bedingungen (sweating guarded-hotplate test). 2014. International Organization for Standardization. ISO 11092:2014 - Textilien – Physiologische Wirkungen – Messung des Wärme- und Wasserdampfdurchgangswiderstands unter stationären Bedingungen (sweating guarded-hotplate test). 2014.
34.
go back to reference Kamalha E, Zeng Y, Mwasiagi JI, Kyatuheire S. The comfort dimension; a review of perception in clothing. J Sens Stud. 2013;28(6):423–44.CrossRef Kamalha E, Zeng Y, Mwasiagi JI, Kyatuheire S. The comfort dimension; a review of perception in clothing. J Sens Stud. 2013;28(6):423–44.CrossRef
35.
go back to reference Siewiorek D, Smailagic A, Starner T. Application Design for Wearable Computing. In: Synthesis Lectures on Mobile and Pervasive Computing, vol. 3; 2008. p. 1–66. Siewiorek D, Smailagic A, Starner T. Application Design for Wearable Computing. In: Synthesis Lectures on Mobile and Pervasive Computing, vol. 3; 2008. p. 1–66.
36.
go back to reference Luchsinger RH, Pedretti M, Reinhard A. Pressure induced stability: from pneumatic structures to Tensairity®. J Bionic Eng. 2018;1(4):141–8.CrossRef Luchsinger RH, Pedretti M, Reinhard A. Pressure induced stability: from pneumatic structures to Tensairity®. J Bionic Eng. 2018;1(4):141–8.CrossRef
37.
go back to reference Vogel S. Comparative biomechanics. Princeton: Princeton University Press; 2003. p. 413–5. Vogel S. Comparative biomechanics. Princeton: Princeton University Press; 2003. p. 413–5.
38.
go back to reference Haag A, Weder M, Camenzind M, Rossi R. Laser transmission welding of membranes and textiles. Tech Textilien. 2018;61:E91–3. Haag A, Weder M, Camenzind M, Rossi R. Laser transmission welding of membranes and textiles. Tech Textilien. 2018;61:E91–3.
39.
go back to reference Amberg M, Haag A, Storchenegger R, Rupper P, Lehmeier F, Rossi RM, et al. Absorbing TiO x thin film enabling laser welding of polyurethane membranes and polyamide fibers. Sci Technol Adv Mater. 2015;16(5). Amberg M, Haag A, Storchenegger R, Rupper P, Lehmeier F, Rossi RM, et al. Absorbing TiO x thin film enabling laser welding of polyurethane membranes and polyamide fibers. Sci Technol Adv Mater. 2015;16(5).
40.
go back to reference Geiger DW. Characterization of postural tremor in essential tremor using a seven-degree-of-freedom model. Master Thesis: Brigham Young University; 2014. Geiger DW. Characterization of postural tremor in essential tremor using a seven-degree-of-freedom model. Master Thesis: Brigham Young University; 2014.
41.
42.
go back to reference Gates DH, Walters LS, Cowley J, Wilken JM. Range of Motion Requirements for Upper-Limb Activities of Daily Living. 2016;70(1). Gates DH, Walters LS, Cowley J, Wilken JM. Range of Motion Requirements for Upper-Limb Activities of Daily Living. 2016;70(1).
43.
go back to reference Heldman DA, Jankovic J, Vaillancourt DE, Prodoehl J, Elble RJ, Giuffrida JP. Essential tremor quantification during activities of daily living. Park Relat Disord. 2011;17(7):537–42.CrossRef Heldman DA, Jankovic J, Vaillancourt DE, Prodoehl J, Elble RJ, Giuffrida JP. Essential tremor quantification during activities of daily living. Park Relat Disord. 2011;17(7):537–42.CrossRef
44.
go back to reference Welch PD. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. 1967;AU-15(2):70–3. Welch PD. The use of fast Fourier transform for the estimation of power spectra: A method based on time averaging over short, modified periodograms. 1967;AU-15(2):70–3.
45.
go back to reference Mcnames J. Signal processing. In: Mechanisms and Emerging Therapies in Tremor Disorders; 2013. p. 371–89.CrossRef Mcnames J. Signal processing. In: Mechanisms and Emerging Therapies in Tremor Disorders; 2013. p. 371–89.CrossRef
46.
go back to reference Deuschl G, Raethjen J, Lindemann M, Krack P. The pathophysiology of tremor. Muscle Nerve. 2001;24(6):716–35.PubMedCrossRef Deuschl G, Raethjen J, Lindemann M, Krack P. The pathophysiology of tremor. Muscle Nerve. 2001;24(6):716–35.PubMedCrossRef
47.
go back to reference Bain PG, Mally J, Gresty M, Findley LJ. Assessing the impact of essential tremor on upper limb function. J Neurol. 1993;241(1):54–61.PubMedCrossRef Bain PG, Mally J, Gresty M, Findley LJ. Assessing the impact of essential tremor on upper limb function. J Neurol. 1993;241(1):54–61.PubMedCrossRef
48.
go back to reference Riou N. Massage therapy for essential tremor: quieting the mind. J Bodyw Mov Ther. 2013;17(4):488–94.PubMedCrossRef Riou N. Massage therapy for essential tremor: quieting the mind. J Bodyw Mov Ther. 2013;17(4):488–94.PubMedCrossRef
49.
go back to reference Formica D, Charles SK, Zollo L, Guglielmelli E, Hogan N, Krebs HI. The passive stiffness of the wrist and forearm. J Neurophysiol. 2012;108(4):1158–66.PubMedPubMedCentralCrossRef Formica D, Charles SK, Zollo L, Guglielmelli E, Hogan N, Krebs HI. The passive stiffness of the wrist and forearm. J Neurophysiol. 2012;108(4):1158–66.PubMedPubMedCentralCrossRef
50.
go back to reference Seegmiller DB, Eggett DL, Charles SK. The effect of common wrist orthoses on the stiffness of wrist rotations. J Rehabil Res Dev. 2016;53(6):1151–66.PubMedCrossRef Seegmiller DB, Eggett DL, Charles SK. The effect of common wrist orthoses on the stiffness of wrist rotations. J Rehabil Res Dev. 2016;53(6):1151–66.PubMedCrossRef
51.
go back to reference Maurel W. 3D modeling of the human upper limb including the biomechanics of joints, muscles and soft tissues. Biomechanics. 1999;1906(1906):206. Maurel W. 3D modeling of the human upper limb including the biomechanics of joints, muscles and soft tissues. Biomechanics. 1999;1906(1906):206.
52.
go back to reference Romilly DP, Anglin C, Gosine RG, Hershler C, Raschke SU. A functional task analysis and motion simulation for the development of a powered upper-limb Orthosis. IEEE Trans Rehabil Eng. 1994;2(3):119–29.CrossRef Romilly DP, Anglin C, Gosine RG, Hershler C, Raschke SU. A functional task analysis and motion simulation for the development of a powered upper-limb Orthosis. IEEE Trans Rehabil Eng. 1994;2(3):119–29.CrossRef
53.
go back to reference Mell AG, Childress BL, Hughes RE. The effect of wearing a wrist splint on shoulder kinematics during object manipulation. Arch Phys Med Rehabil. 2005;86(8):1661–4.PubMedCrossRef Mell AG, Childress BL, Hughes RE. The effect of wearing a wrist splint on shoulder kinematics during object manipulation. Arch Phys Med Rehabil. 2005;86(8):1661–4.PubMedCrossRef
54.
go back to reference I-G Y, M-Y J, H-S J, Lee J. Effects of wrist-extension Orthosis on shoulder and scapular muscle activities during simulated assembly tasks. Ind Health. 2010;48(1):108–14.CrossRef I-G Y, M-Y J, H-S J, Lee J. Effects of wrist-extension Orthosis on shoulder and scapular muscle activities during simulated assembly tasks. Ind Health. 2010;48(1):108–14.CrossRef
56.
go back to reference Haara MM, Manninen P, Kröger H, Arokoski JPA, Kärkkäinen A, Knekt P, et al. Osteoarthritis of finger joints in Finns aged 30 or over: prevalence, determinants, and association with mortality. Ann Rheum Dis. 2003;62(2):151–8.PubMedPubMedCentralCrossRef Haara MM, Manninen P, Kröger H, Arokoski JPA, Kärkkäinen A, Knekt P, et al. Osteoarthritis of finger joints in Finns aged 30 or over: prevalence, determinants, and association with mortality. Ann Rheum Dis. 2003;62(2):151–8.PubMedPubMedCentralCrossRef
57.
go back to reference Miller RJ. Wrist MRI and Carpal Instability: What the Surgeon Needs to Know, and the Case for Dynamic Imaging. Semin Musculoskelet Radiol. 2001;05(03):235–40.CrossRef Miller RJ. Wrist MRI and Carpal Instability: What the Surgeon Needs to Know, and the Case for Dynamic Imaging. Semin Musculoskelet Radiol. 2001;05(03):235–40.CrossRef
58.
go back to reference Hasegawa Y, Hasegawa T, Eguchi K. Pneumatic tubular body fixture for wearable assistive device -Analysis and design of active cuff to hold upper limb. Int Conf Intell Robots Syst. IEEE. 2014:2140–5.. Hasegawa Y, Hasegawa T, Eguchi K. Pneumatic tubular body fixture for wearable assistive device -Analysis and design of active cuff to hold upper limb. Int Conf Intell Robots Syst. IEEE. 2014:2140–5..
Metadata
Title
Design of a lightweight passive orthosis for tremor suppression
Authors
Nicolas Philip Fromme
Martin Camenzind
Robert Riener
René M. Rossi
Publication date
01-12-2020
Publisher
BioMed Central
Published in
Journal of NeuroEngineering and Rehabilitation / Issue 1/2020
Electronic ISSN: 1743-0003
DOI
https://doi.org/10.1186/s12984-020-00673-7

Other articles of this Issue 1/2020

Journal of NeuroEngineering and Rehabilitation 1/2020 Go to the issue