Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 1/2014

01-01-2014 | General Review

The sound of orthopaedic surgery—the application of acoustic emission technology in orthopaedic surgery: a review

Authors: Mustafa S. Rashid, Rhys Pullin

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 1/2014

Login to get access

Abstract

Acoustic emission technology has been developed and extensively used as a non-destructive method of testing within engineering. In recent years, acoustic emission has gained popularity within the field of Orthopaedic research in a variety of situations. It is an attractive method in the detection of flaws within structures due its high sensitivity and non-destructive nature. The aim of this article is firstly to critically review the research conducted using acoustic emission testing in a variety of Orthopaedic-related situations and to present the technique to the wider Orthopaedic community. A summary of the principles and practical aspects of using acoustic emission testing are outlined. Acoustic emission has been validated as a method of early detection of aseptic loosening in femoral components in total hip arthroplasty in several well-conducted in vitro studies [13]. Other studies have used acoustic emission to detect microdamage in bone and to assess the biomechanical properties of bone and allografts [9]. Researchers have also validated the use of acoustic emission to detect and monitor fracture healing [4]. Several studies have applied acoustic emission to spinal surgery and specifically to assess the biomechanical environment in titanium mesh cages used in spinal surgery [10, 11]. Despite its growing popularity within Orthopaedic research, acoustic emission remains are relatively unfamiliar technique to the majority of Orthopaedic surgeons.
Literature
1.
go back to reference Davies JP, Tse MK, Harris WH (1996) Monitoring the integrity of the cement metal interface of total joint components in vitro using acoustic emission and ultrasound. J Arthroplasty 11(5):594–601PubMedCrossRef Davies JP, Tse MK, Harris WH (1996) Monitoring the integrity of the cement metal interface of total joint components in vitro using acoustic emission and ultrasound. J Arthroplasty 11(5):594–601PubMedCrossRef
2.
go back to reference Sugiyama H, Whiteside LA, Kaiser AD (1989) Examination of rotational fixation of the femoral component in total hip arthroplasty: a mechanical study of micromovement and acoustic emission. Clin Orthop Relat Res 249:122–128PubMed Sugiyama H, Whiteside LA, Kaiser AD (1989) Examination of rotational fixation of the femoral component in total hip arthroplasty: a mechanical study of micromovement and acoustic emission. Clin Orthop Relat Res 249:122–128PubMed
3.
go back to reference Mavrogordato M, Taylor M, Taylor A, Browne M (2011) Real time monitoring of progressive damage during loading of a simplified total hip stem construct using embedded acoustic emission sensors. Med Eng Phys 33:395–406PubMedCrossRef Mavrogordato M, Taylor M, Taylor A, Browne M (2011) Real time monitoring of progressive damage during loading of a simplified total hip stem construct using embedded acoustic emission sensors. Med Eng Phys 33:395–406PubMedCrossRef
4.
go back to reference Watanabe Y, Takai S, Arai Y, Yoshino N, Hirasawa Y (2001) Prediction of mechanical properties of healing fractures using acoustic emission. J Orthop Res 19:548–553PubMedCrossRef Watanabe Y, Takai S, Arai Y, Yoshino N, Hirasawa Y (2001) Prediction of mechanical properties of healing fractures using acoustic emission. J Orthop Res 19:548–553PubMedCrossRef
6.
go back to reference Nielson A (1980) Acoustic emission source based on pencil lead breaking. Report 80-15, Danish Welding Institute Nielson A (1980) Acoustic emission source based on pencil lead breaking. Report 80-15, Danish Welding Institute
7.
go back to reference Hirasawa Y, Takai S, Kim WC, Takenaka N, Yoshino N, Watanabe Y (2002) Biomechanical monitoring of healing bone based on acoustic emission technology. Clin Orthop Relat Res 402:236–244PubMedCrossRef Hirasawa Y, Takai S, Kim WC, Takenaka N, Yoshino N, Watanabe Y (2002) Biomechanical monitoring of healing bone based on acoustic emission technology. Clin Orthop Relat Res 402:236–244PubMedCrossRef
8.
go back to reference Wright TM, Vosburgh F, Burstein AH (1981) Permanent deformation of compact bone monitored by acoustic emission. J Biomech 14:405–409PubMedCrossRef Wright TM, Vosburgh F, Burstein AH (1981) Permanent deformation of compact bone monitored by acoustic emission. J Biomech 14:405–409PubMedCrossRef
9.
go back to reference Akkus O, Rimnac CM (2001) Fracture resistance of gamma radiation sterilized cortical bone allografts. J Orthop Res 19:927–934PubMedCrossRef Akkus O, Rimnac CM (2001) Fracture resistance of gamma radiation sterilized cortical bone allografts. J Orthop Res 19:927–934PubMedCrossRef
10.
go back to reference Hasegawa K, Takahashi H, Koga Y, Kawashima T, Hara T, Tanabe Y, Tanaka S (1993) Failure characteristics of osteoporotic vertebral bodies monitored by acoustic emission. Spine (Phila Pa 1976) 15:2314–2320CrossRef Hasegawa K, Takahashi H, Koga Y, Kawashima T, Hara T, Tanabe Y, Tanaka S (1993) Failure characteristics of osteoporotic vertebral bodies monitored by acoustic emission. Spine (Phila Pa 1976) 15:2314–2320CrossRef
11.
go back to reference Hasegawa K, Abe M, Washio T, Hara T (2001) An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine Phila Pa 8:957–963CrossRef Hasegawa K, Abe M, Washio T, Hara T (2001) An experimental study on the interface strength between titanium mesh cage and vertebra in reference to vertebral bone mineral density. Spine Phila Pa 8:957–963CrossRef
12.
go back to reference Closkey RF, Parsons JR, Lee CK (1993) Mechanics of interbody spinal fusion: analysis of critical bone graft area. Spine 18:1011–1015PubMedCrossRef Closkey RF, Parsons JR, Lee CK (1993) Mechanics of interbody spinal fusion: analysis of critical bone graft area. Spine 18:1011–1015PubMedCrossRef
13.
go back to reference Azangwe G, Fraser K, Mathias KJ, Siddiqui AM (2000) In-vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission. Med Eng Phys 22:279–283PubMedCrossRef Azangwe G, Fraser K, Mathias KJ, Siddiqui AM (2000) In-vitro monitoring of rabbit anterior cruciate ligament damage by acoustic emission. Med Eng Phys 22:279–283PubMedCrossRef
14.
go back to reference Pechon PHM, Pullin R, Eaton MJ, Evans SL (2010) A novel sensor technology may be used to predict impending iatrogenic femur fracture during uncemented hip arthroplasty in real time. Original laboratory research using deer femora, British Orthopaedic Research Society, Cardiff, 12–13 July 2010 Pechon PHM, Pullin R, Eaton MJ, Evans SL (2010) A novel sensor technology may be used to predict impending iatrogenic femur fracture during uncemented hip arthroplasty in real time. Original laboratory research using deer femora, British Orthopaedic Research Society, Cardiff, 12–13 July 2010
Metadata
Title
The sound of orthopaedic surgery—the application of acoustic emission technology in orthopaedic surgery: a review
Authors
Mustafa S. Rashid
Rhys Pullin
Publication date
01-01-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-012-1139-0

Other articles of this Issue 1/2014

European Journal of Orthopaedic Surgery & Traumatology 1/2014 Go to the issue