Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 1/2014

01-01-2014 | Original Article

Total hip arthroplasty with the MS-30 polished surface cemented stem: a single surgeon consecutive series study at 10 year follow-up

Authors: Gavin H. O. Brigstocke, Philip A. Mitchell, John W. Rosson

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 1/2014

Login to get access

Abstract

The Morscher-Sportorno femoral stem is a stainless steel, straight, three-dimensionally tapered, collarless implant for cemented fixation in total hip replacement. The clinical and radiographic results of this implant at a minimum of 5-year follow-up have been extremely encouraging. However, the results at 10 years have yet to be reported. Therefore, we wished to establish the clinical performance and survival of the polished surface MS-30 femoral stem at a minimum of 10-year follow-up. We report the results at a minimum follow-up of 10 years of a single surgeon series of 55 total hip replacements with the polished surface MS-30 cemented femoral component in 48 consecutive patients aged between 50 and 64. The median period of observation was 12 years (inter-quartile range, 10–13). Six patients died with their implant in situ, and one patient was unable to attend for follow-up. All the remaining 41 patients with 47 total hip replacements were reviewed. All patients were assessed clinically with the use of the Oxford hip score, and radiographs taken at the latest follow-up were evaluated by an independent specialist hip surgeon. To date, none of the implants have been revised. The median Oxford hip score was 13 (inter-quartile range, 12–14). Radiologically, no stems had evidence of loosening on assessment by the Harris criteria, and only 4 hips (8.5 %) had osteolysis adjacent to the stem, mostly in Gruen zone 7. The results of the polished surface MS-30 femoral stem were satisfactory with survivorship at a minimum of 10 years of 100 %. These findings support the continued use of this femoral component.
Literature
1.
go back to reference Middleton RG, Howie DW, Costi K, Sharpe P (1998) Effects of design changes on cemented tapered femoral stem fixation. Clin Orthop Relat Res 355:47–56PubMedCrossRef Middleton RG, Howie DW, Costi K, Sharpe P (1998) Effects of design changes on cemented tapered femoral stem fixation. Clin Orthop Relat Res 355:47–56PubMedCrossRef
2.
go back to reference Morscher E, Spotorno L, Mumenthaler A, Frick W (1995) The cemented MS-30 stem. Springer, Berlin Morscher E, Spotorno L, Mumenthaler A, Frick W (1995) The cemented MS-30 stem. Springer, Berlin
3.
go back to reference Williams HD, Browne G, Gie GA, Ling RS, Timperley AJ, Wendover NA (2002) The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips. J Bone Joint Surg Br 84(3):324–334PubMedCrossRef Williams HD, Browne G, Gie GA, Ling RS, Timperley AJ, Wendover NA (2002) The Exeter universal cemented femoral component at 8 to 12 years. A study of the first 325 hips. J Bone Joint Surg Br 84(3):324–334PubMedCrossRef
4.
go back to reference Hook S, Moulder E, Yates PJ, Burston BJ, Whitley E, Bannister GC (2006) The Exeter Universal stem: a minimum ten-year review from an independent centre. J Bone Joint Surg Br 88(12):1584–1590PubMedCrossRef Hook S, Moulder E, Yates PJ, Burston BJ, Whitley E, Bannister GC (2006) The Exeter Universal stem: a minimum ten-year review from an independent centre. J Bone Joint Surg Br 88(12):1584–1590PubMedCrossRef
5.
go back to reference Berli BJ, Schafer D, Morscher EW (2005) Ten-year survival of the MS-30 matt-surfaced cemented stem. J Bone Joint Surg Br 87(7):928–933PubMedCrossRef Berli BJ, Schafer D, Morscher EW (2005) Ten-year survival of the MS-30 matt-surfaced cemented stem. J Bone Joint Surg Br 87(7):928–933PubMedCrossRef
6.
go back to reference Berli B, Elke R, Morscher EW (2005) The cemented MS-30 stem in total hip replacement, matte versus polished surface: minimum of 5 years of clinical and radiographic results of a prospective study. ATSM International, West Consho-hocken Berli B, Elke R, Morscher EW (2005) The cemented MS-30 stem in total hip replacement, matte versus polished surface: minimum of 5 years of clinical and radiographic results of a prospective study. ATSM International, West Consho-hocken
7.
go back to reference Dawson J, Fitzpatrick R, Carr A, Murray D (1996) Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br 78(2):185–190PubMed Dawson J, Fitzpatrick R, Carr A, Murray D (1996) Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br 78(2):185–190PubMed
8.
go back to reference Harris WH, McCarthy JC Jr, O’Neill DA (1982) Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64(7):1063–1067PubMed Harris WH, McCarthy JC Jr, O’Neill DA (1982) Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am 64(7):1063–1067PubMed
9.
go back to reference Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
10.
go back to reference Howie DW, Middleton RG, Costi K (1998) Loosening of matt and polished cemented femoral stems. J Bone Joint Surg Br 80(4):573–576PubMedCrossRef Howie DW, Middleton RG, Costi K (1998) Loosening of matt and polished cemented femoral stems. J Bone Joint Surg Br 80(4):573–576PubMedCrossRef
11.
go back to reference Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacement in Sweden. follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 64(5):497–506PubMedCrossRef Malchau H, Herberts P, Ahnfelt L (1993) Prognosis of total hip replacement in Sweden. follow-up of 92,675 operations performed 1978–1990. Acta Orthop Scand 64(5):497–506PubMedCrossRef
12.
go back to reference Ling RS, Charity J, Lee AJ, Whitehouse SL, Timperley AJ, Gie GA (2005) The long-term results of the original exeter polished cemented femoral component: a follow-up report. J Arthroplasty 24(4):511–517CrossRef Ling RS, Charity J, Lee AJ, Whitehouse SL, Timperley AJ, Gie GA (2005) The long-term results of the original exeter polished cemented femoral component: a follow-up report. J Arthroplasty 24(4):511–517CrossRef
Metadata
Title
Total hip arthroplasty with the MS-30 polished surface cemented stem: a single surgeon consecutive series study at 10 year follow-up
Authors
Gavin H. O. Brigstocke
Philip A. Mitchell
John W. Rosson
Publication date
01-01-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-012-1132-7

Other articles of this Issue 1/2014

European Journal of Orthopaedic Surgery & Traumatology 1/2014 Go to the issue