Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 1/2014

01-01-2014 | Original Article

Anatomy of the clavicle and its medullary canal: a computed tomography study

Authors: P. R. King, S. Scheepers, A. Ikram

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 1/2014

Login to get access

Abstract

Background

With recent literature indicating certain clavicle shaft fracture types are best treated surgically, there is renewed interest in the anatomy of the clavicle. Intramedullary fixation of clavicle fractures requires an adequate medullary canal to accommodate the fixation device used. This computed tomography anatomical study of the clavicle and its medullary canal describes its general anatomy and determines the suitability of its medullary canal to intramedullary fixation.

Description of methods

Four hundred and eighteen clavicles in 209 patients were examined using computed tomography imaging. The length and curvatures as well as the height and width of the clavicle and its canal at various predetermined points were measured. The start and end of the medullary canal from the sternal and acromial ends of the clavicle were determined. The data was grouped according to age, gender and lateralization.

Summary of results

The average length of the clavicle was 151.15 mm with the average sternal and acromial curvature being 146° and 133°, respectively. The medullary canal starts on average 6.59 mm from the sternal end and ends 19.56 mm from the acromial end with the average height and width of the canal at the middle third being 5.61 and 6.63 mm, respectively.

Conclusion

The medullary canal of the clavicle is large enough to accommodate commonly used intramedullary devices in the majority of cases. The medullary canal extends far enough medially and laterally for an intramedullary device to adequately bridge most middle third clavicle fractures. An alternative surgical option should be available in theatre when treating females as the medullary canal is too small to pass an intramedullary device past the fracture site on rare occasions.
Literature
1.
go back to reference Moseley HF (1964) The clavicle: its function and anatomy. CORR 58:17–28 Moseley HF (1964) The clavicle: its function and anatomy. CORR 58:17–28
2.
go back to reference Huang JI, Toogood P, Chen MR, Wilber JH, Cooperman DR (2007) Clavicular anatomy and the applicability of precontoured plates. J Bone Joint Surg Am 89(10):2260PubMedCrossRef Huang JI, Toogood P, Chen MR, Wilber JH, Cooperman DR (2007) Clavicular anatomy and the applicability of precontoured plates. J Bone Joint Surg Am 89(10):2260PubMedCrossRef
3.
go back to reference Andermahr J, Jubel A, Elsner A, Johann J, Prokop A, Rehm K, Koebke J (2007) Anatomy of the clavicle and the intramedullary nailing of midclavicular fractures. Clin Anat 20(1):48–56PubMedCrossRef Andermahr J, Jubel A, Elsner A, Johann J, Prokop A, Rehm K, Koebke J (2007) Anatomy of the clavicle and the intramedullary nailing of midclavicular fractures. Clin Anat 20(1):48–56PubMedCrossRef
4.
go back to reference Ahmad M, Trawhella MJ, Bayliss NC (2006). Study to describe the morphology of a series of clavicles and the dimensions of its intramedullary canal. J Bone Joint Surg Br 88-B no.(supp III):401 Ahmad M, Trawhella MJ, Bayliss NC (2006). Study to describe the morphology of a series of clavicles and the dimensions of its intramedullary canal. J Bone Joint Surg Br 88-B no.(supp III):401
5.
go back to reference Daruwalla Z, Courtis P, Fitzpatrick C, Fitzpatrick D, Mullet H (2010) Anatomic variation of the clavicle: a novel 3-dimensional study. Clin Anat 23:199–209PubMed Daruwalla Z, Courtis P, Fitzpatrick C, Fitzpatrick D, Mullet H (2010) Anatomic variation of the clavicle: a novel 3-dimensional study. Clin Anat 23:199–209PubMed
6.
go back to reference Walters J, Solomons C, Roche S (2010) A morphometric study of the clavicle. SA orthop J 9(3):47–52 Walters J, Solomons C, Roche S (2010) A morphometric study of the clavicle. SA orthop J 9(3):47–52
7.
go back to reference Bortier HE, Amit B, Huysmans T, Van Glabbeek F, Sijbers J, Pinho R, Gielen J, Hubens G (2009): Osteologic exploration of the clavicle: a new approach. FASEB J. April 23 (Meeting Abstract Supplement) LB9 Bortier HE, Amit B, Huysmans T, Van Glabbeek F, Sijbers J, Pinho R, Gielen J, Hubens G (2009): Osteologic exploration of the clavicle: a new approach. FASEB J. April 23 (Meeting Abstract Supplement) LB9
8.
go back to reference Sinha A, Edwin J, Sreeharsha B, Bhalaik V, Brownson P (2011) A radiological study to define safe zones for drilling during plating of clavicle fractures. J Bone Joint Surg Br 93(9):1247–1252PubMedCrossRef Sinha A, Edwin J, Sreeharsha B, Bhalaik V, Brownson P (2011) A radiological study to define safe zones for drilling during plating of clavicle fractures. J Bone Joint Surg Br 93(9):1247–1252PubMedCrossRef
9.
go back to reference Galley I, Watts A, Bain G (2009) The anatomic relationship of the axillary artery and vein to the clavicle: a cadaveric study. J Shoulder Elbow Surg 18(5):21–25CrossRef Galley I, Watts A, Bain G (2009) The anatomic relationship of the axillary artery and vein to the clavicle: a cadaveric study. J Shoulder Elbow Surg 18(5):21–25CrossRef
10.
go back to reference King PR, Ikram A (2011) Intramedullary locked fixation of middle third clavicle fractures—a review of early results. SA orthop J 10(4):67–74 King PR, Ikram A (2011) Intramedullary locked fixation of middle third clavicle fractures—a review of early results. SA orthop J 10(4):67–74
11.
go back to reference Ferran N, Hodgson P, Vannet N, Williams R, Evans R (2010) Locked intramedullary fixation versus plating for displaced and shortened midshaft clavicle fractures: a randomized clinical trial. J Should Elb Surg 19:783–789CrossRef Ferran N, Hodgson P, Vannet N, Williams R, Evans R (2010) Locked intramedullary fixation versus plating for displaced and shortened midshaft clavicle fractures: a randomized clinical trial. J Should Elb Surg 19:783–789CrossRef
12.
go back to reference Houwert R, Wijdicks F, Steins Bisschop C, Verleisdonk E, Kruyt M (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36(3):579–585PubMedCentralPubMedCrossRef Houwert R, Wijdicks F, Steins Bisschop C, Verleisdonk E, Kruyt M (2012) Plate fixation versus intramedullary fixation for displaced mid-shaft clavicle fractures: a systematic review. Int Orthop 36(3):579–585PubMedCentralPubMedCrossRef
13.
go back to reference Liu H, Chang C, Chia W, Chen C, Tarng Y, Wong C (2010) Comparison of plates versus intramedullary nails for fixation of displaced midshaft clavicular fractures. J Trauma 69(6):82–87CrossRef Liu H, Chang C, Chia W, Chen C, Tarng Y, Wong C (2010) Comparison of plates versus intramedullary nails for fixation of displaced midshaft clavicular fractures. J Trauma 69(6):82–87CrossRef
Metadata
Title
Anatomy of the clavicle and its medullary canal: a computed tomography study
Authors
P. R. King
S. Scheepers
A. Ikram
Publication date
01-01-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 1/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-012-1130-9

Other articles of this Issue 1/2014

European Journal of Orthopaedic Surgery & Traumatology 1/2014 Go to the issue