Skip to main content
Top
Published in: Clinical Research in Cardiology 11/2019

01-11-2019 | Sudden Cardiac Death | Original Paper

Feasibility of entirely subcutaneous ICD™ systems in patients with coronary artery disease

Authors: Kevin Willy, Markus Bettin, Florian Reinke, Nils Bögeholz, Christian Ellermann, Benjamin Rath, Patrick Leitz, Julia Köbe, Lars Eckardt, Gerrit Frommeyer

Published in: Clinical Research in Cardiology | Issue 11/2019

Login to get access

Abstract

Background

The subcutaneous ICD (S-ICD™) is an important advance in device therapy for the prevention of sudden cardiac death (SCD). Although current guidelines recommend S-ICD™ use, long-term data are still limited, especially in subgroups. Among several cardiac diseases that prone to SCD, coronary artery disease (CAD) carries several peculiarities that may hamper S-ICD™ therapy in this cohort. CAD can lead to an ischemic cardiomyopathy (ICM) with a reduced left-ventricular ejection fraction (LVEF) and bundle branch blocks, which can be difficult for ICD sensing and discrimination of arrhythmia. CAD is mainly driven by risk factors such as diabetes mellitus, which put these patients at an elevated risk for infectious complications of cardiac devices. Furthermore, in ICM myocardial scars are frequent and are a potential substrate for ventricular tachycardia, which may be accessible for antitachycardia pacing. At the moment, it remains unclear if there is a value of S-ICD™ therapy in this subgroup. Therefore, this study analysed patients with CAD.

Materials and methods

All S-ICD™ patients with CAD as the main indication for ICD implantation (n = 45 patients) in our large-scaled single-center S-ICD™ registry (n = 249 patients) were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a mean follow-up of 22.5 ± 8.3 months.

Results

Primary prevention of SCD was the indication for implantation of an S-ICD™ in 28 patients (62%). Of all 45 patients with an overall mean age of 58.1 ± 11.4 years, 40 were male (88%). The mean LVEF was 37.7 ± 12.6%. Three episodes of ventricular arrhythmia (one monomorphic, one polymorphic, one ventricular fibrillation) were adequately terminated in three patients (7%). In only one patient, oversensing resulting in an inappropriate shock was observed, which could be managed by changing the sensing vector. 15 of the examined 45 patients previously had a transvenous ICD, which was explanted due to system-related infections. In only two patients, S-ICD™ was changed to transvenous ICD because of the need of antibradycardia stimulation. There were no S-ICD™ system-related infections.

Conclusion

The S-ICD™ seems to be a valuable option for the prevention of SCD in CAD patients. Patients with systemic infections of a transvenous ICD and, therefore, a need for an alternative might benefit from the absence of intracardiac leads as the S-ICD™ is safe and works flawlessly in these patients. Inadequate shock delivery was very rare, while every episode of ventricular arrhythmia was terminated by the first shock.
Literature
2.
go back to reference Lambiase PD, Barr C, Theuns DA, Knops R, Neuzil P, Johansen JB, Hood M, Pedersen S, Kaab S, Murgatroyd F, Reeve HL, Carter N, Boersma L, Investigators E (2014) Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry. Eur Heart J 35(25):1657–1665. https://doi.org/10.1093/eurheartj/ehu112 (PubMed PMID: 24670710; PubMed Central PMCID: PMCPMC4076663) CrossRefPubMedPubMedCentral Lambiase PD, Barr C, Theuns DA, Knops R, Neuzil P, Johansen JB, Hood M, Pedersen S, Kaab S, Murgatroyd F, Reeve HL, Carter N, Boersma L, Investigators E (2014) Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry. Eur Heart J 35(25):1657–1665. https://​doi.​org/​10.​1093/​eurheartj/​ehu112 (PubMed PMID: 24670710; PubMed Central PMCID: PMCPMC4076663) CrossRefPubMedPubMedCentral
3.
go back to reference Burke MC, Gold MR, Knight BP, Barr CS, Theuns D, Boersma LVA, Knops RE, Weiss R, Leon AR, Herre JM, Husby M, Stein KM, Lambiase PD (2015) Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS Registry. J Am Coll Cardiol 65(16):1605–1615. https://doi.org/10.1016/j.jacc.2015.02.047 (PubMed PMID: 25908064) CrossRefPubMed Burke MC, Gold MR, Knight BP, Barr CS, Theuns D, Boersma LVA, Knops RE, Weiss R, Leon AR, Herre JM, Husby M, Stein KM, Lambiase PD (2015) Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS Registry. J Am Coll Cardiol 65(16):1605–1615. https://​doi.​org/​10.​1016/​j.​jacc.​2015.​02.​047 (PubMed PMID: 25908064) CrossRefPubMed
9.
go back to reference van der Heijden AC, Borleffs CJ, Buiten MS, Thijssen J, van Rees JB, Cannegieter SC, Schalij MJ, van Erven L (2015) The clinical course of patients with implantable cardioverter-defibrillators: extended experience on clinical outcome, device replacements, and device-related complications. Heart Rhythm 12(6):1169–1176. https://doi.org/10.1016/j.hrthm.2015.02.035 (PubMed PMID: 25749138) CrossRefPubMed van der Heijden AC, Borleffs CJ, Buiten MS, Thijssen J, van Rees JB, Cannegieter SC, Schalij MJ, van Erven L (2015) The clinical course of patients with implantable cardioverter-defibrillators: extended experience on clinical outcome, device replacements, and device-related complications. Heart Rhythm 12(6):1169–1176. https://​doi.​org/​10.​1016/​j.​hrthm.​2015.​02.​035 (PubMed PMID: 25749138) CrossRefPubMed
10.
go back to reference Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, Hood M, Kuschyk J, Jones P, Duffy E, Husby M, Stein K, Lambiase PD, Group EI (2017) implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol 70(7):830–841. https://doi.org/10.1016/j.jacc.2017.06.040 (PubMed PMID: 28797351) CrossRefPubMed Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, Hood M, Kuschyk J, Jones P, Duffy E, Husby M, Stein K, Lambiase PD, Group EI (2017) implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol 70(7):830–841. https://​doi.​org/​10.​1016/​j.​jacc.​2017.​06.​040 (PubMed PMID: 28797351) CrossRefPubMed
11.
go back to reference Boersma L, Burke MC, Neuzil P, Lambiase P, Friehling T, Theuns DA, Garcia F, Carter N, Stivland T, Weiss R, Effortless, Investigators IDES (2016) Infection and mortality after implantation of a subcutaneous ICD after transvenous ICD extraction. Heart Rhythm 13(1):157–164. https://doi.org/10.1016/j.hrthm.2015.0 (PubMed PMID: 26341604) CrossRefPubMed Boersma L, Burke MC, Neuzil P, Lambiase P, Friehling T, Theuns DA, Garcia F, Carter N, Stivland T, Weiss R, Effortless, Investigators IDES (2016) Infection and mortality after implantation of a subcutaneous ICD after transvenous ICD extraction. Heart Rhythm 13(1):157–164. https://​doi.​org/​10.​1016/​j.​hrthm.​2015.​0 (PubMed PMID: 26341604) CrossRefPubMed
13.
go back to reference Moss AJ, Schuger C, Beck CA, Brown MW, Cannom DS, Daubert JP, Estes NA, Greenberg H, Hall WJ, Huang DT, Kautzner J, Klein H, McNitt S, Olshansky B, Shoda M, Wilber D, Zareba W (2012) Investigators M-RT. Reduction in inappropriate therapy and mortality through ICD programming. New Engl J Med 367(24):2275–2283. https://doi.org/10.1056/NEJMoa1211107 (PubMed PMID: 23131066) CrossRefPubMed Moss AJ, Schuger C, Beck CA, Brown MW, Cannom DS, Daubert JP, Estes NA, Greenberg H, Hall WJ, Huang DT, Kautzner J, Klein H, McNitt S, Olshansky B, Shoda M, Wilber D, Zareba W (2012) Investigators M-RT. Reduction in inappropriate therapy and mortality through ICD programming. New Engl J Med 367(24):2275–2283. https://​doi.​org/​10.​1056/​NEJMoa1211107 (PubMed PMID: 23131066) CrossRefPubMed
14.
go back to reference Gasparini M, Menozzi C, Proclemer A, Landolina M, Iacopino S, Carboni A, Lombardo E, Regoli F, Biffi M, Burrone V, Denaro A, Boriani G (2009) A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [role of long dEtection window programming in patients with LEft VentriculAr dysfunction, non-ischemic eTiology in primary prevention treated with a biventricular ICD] study. Eu Heart J 30(22):2758–2767. https://doi.org/10.1093/eurheartj/ehp247 (PubMed PMID: 19567380; PubMed Central PMCID: PMCPMC2777026) CrossRef Gasparini M, Menozzi C, Proclemer A, Landolina M, Iacopino S, Carboni A, Lombardo E, Regoli F, Biffi M, Burrone V, Denaro A, Boriani G (2009) A simplified biventricular defibrillator with fixed long detection intervals reduces implantable cardioverter defibrillator (ICD) interventions and heart failure hospitalizations in patients with non-ischaemic cardiomyopathy implanted for primary prevention: the RELEVANT [role of long dEtection window programming in patients with LEft VentriculAr dysfunction, non-ischemic eTiology in primary prevention treated with a biventricular ICD] study. Eu Heart J 30(22):2758–2767. https://​doi.​org/​10.​1093/​eurheartj/​ehp247 (PubMed PMID: 19567380; PubMed Central PMCID: PMCPMC2777026) CrossRef
15.
go back to reference Kobe J, Hucklenbroich K, Geisendorfer N, Bettin M, Frommeyer G, Reinke F, Dechering D, Burgmer M, Eckardt L (2017) Posttraumatic stress and quality of life with the totally subcutaneous compared to conventional cardioverter-defibrillator systems. Clin Res Cardiol 106(5):317–321. https://doi.org/10.1007/s00392-016-1055-0 (PubMed PMID: 27878381) CrossRefPubMed Kobe J, Hucklenbroich K, Geisendorfer N, Bettin M, Frommeyer G, Reinke F, Dechering D, Burgmer M, Eckardt L (2017) Posttraumatic stress and quality of life with the totally subcutaneous compared to conventional cardioverter-defibrillator systems. Clin Res Cardiol 106(5):317–321. https://​doi.​org/​10.​1007/​s00392-016-1055-0 (PubMed PMID: 27878381) CrossRefPubMed
16.
go back to reference Boersma LV, Barr CS, Burke MC, Leon AR, Theuns DA, Herre JM, Weiss R, Kremers MS, Neuzil P, Husby MP, Carter N, Stivland TM, Gold MR, Effortless, Investigators IDES (2017) Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication. Heart Rhythm 14(3):367–375. https://doi.org/10.1016/j.hrthm.2016.11.025 (PubMed PMID: 27890798) CrossRefPubMed Boersma LV, Barr CS, Burke MC, Leon AR, Theuns DA, Herre JM, Weiss R, Kremers MS, Neuzil P, Husby MP, Carter N, Stivland TM, Gold MR, Effortless, Investigators IDES (2017) Performance of the subcutaneous implantable cardioverter-defibrillator in patients with a primary prevention indication with and without a reduced ejection fraction versus patients with a secondary prevention indication. Heart Rhythm 14(3):367–375. https://​doi.​org/​10.​1016/​j.​hrthm.​2016.​11.​025 (PubMed PMID: 27890798) CrossRefPubMed
17.
go back to reference Knops RE, Brouwer TF, Barr CS, Theuns DA, Boersma L, Weiss R, Neuzil P, Scholten M, Lambiase PD, Leon AR, Hood M, Jones PW, Wold N, Grace AA, Olde Nordkamp LR, Burke MC, Ide Investigators E (2016) The learning curve associated with the introduction of the subcutaneous implantable defibrillator. Europace 18(7):1010–1015. https://doi.org/10.1093/europace/euv299 (PubMed PMID: 26324840; PubMed Central PMCID: PMCPMC4927061) CrossRefPubMed Knops RE, Brouwer TF, Barr CS, Theuns DA, Boersma L, Weiss R, Neuzil P, Scholten M, Lambiase PD, Leon AR, Hood M, Jones PW, Wold N, Grace AA, Olde Nordkamp LR, Burke MC, Ide Investigators E (2016) The learning curve associated with the introduction of the subcutaneous implantable defibrillator. Europace 18(7):1010–1015. https://​doi.​org/​10.​1093/​europace/​euv299 (PubMed PMID: 26324840; PubMed Central PMCID: PMCPMC4927061) CrossRefPubMed
18.
19.
go back to reference Brouwer TF, Knops RE, Kutyifa V, Barr C, Mondesert B, Boersma LVA, Lambiase PD, Wold N, Jones PW, Healey JS (2018) Propensity score matched comparison of subcutaneous and transvenous implantable cardioverter-defibrillator therapy in the SIMPLE and EFFORTLESS studies. Europace 20(FI2):f240–f24f8. https://doi.org/10.1093/europace/euy083 (PubMed PMID: 29771327) CrossRefPubMed Brouwer TF, Knops RE, Kutyifa V, Barr C, Mondesert B, Boersma LVA, Lambiase PD, Wold N, Jones PW, Healey JS (2018) Propensity score matched comparison of subcutaneous and transvenous implantable cardioverter-defibrillator therapy in the SIMPLE and EFFORTLESS studies. Europace 20(FI2):f240–f24f8. https://​doi.​org/​10.​1093/​europace/​euy083 (PubMed PMID: 29771327) CrossRefPubMed
22.
go back to reference Olde Nordkamp LR, Knops RE, Bardy GH, Blaauw Y, Boersma LV, Bos JS, Delnoy PP, van Dessel PF, Driessen AH, de Groot JR, Herrman JP, Jordaens LJ, Kooiman KM, Maass AH, Meine M, Mizusawa Y, Molhoek SG, van Opstal J, Tijssen JG, Wilde AA (2012) Rationale and design of the PRAETORIAN trial: a prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy. Am Heart J 163(5):753–760. https://doi.org/10.1016/j.ahj.2012.02.012 (PubMed PMID: 22607851) CrossRefPubMed Olde Nordkamp LR, Knops RE, Bardy GH, Blaauw Y, Boersma LV, Bos JS, Delnoy PP, van Dessel PF, Driessen AH, de Groot JR, Herrman JP, Jordaens LJ, Kooiman KM, Maass AH, Meine M, Mizusawa Y, Molhoek SG, van Opstal J, Tijssen JG, Wilde AA (2012) Rationale and design of the PRAETORIAN trial: a prospective, RAndomizEd comparison of subcuTaneOus and tRansvenous ImplANtable cardioverter-defibrillator therapy. Am Heart J 163(5):753–760. https://​doi.​org/​10.​1016/​j.​ahj.​2012.​02.​012 (PubMed PMID: 22607851) CrossRefPubMed
Metadata
Title
Feasibility of entirely subcutaneous ICD™ systems in patients with coronary artery disease
Authors
Kevin Willy
Markus Bettin
Florian Reinke
Nils Bögeholz
Christian Ellermann
Benjamin Rath
Patrick Leitz
Julia Köbe
Lars Eckardt
Gerrit Frommeyer
Publication date
01-11-2019
Publisher
Springer Berlin Heidelberg
Published in
Clinical Research in Cardiology / Issue 11/2019
Print ISSN: 1861-0684
Electronic ISSN: 1861-0692
DOI
https://doi.org/10.1007/s00392-019-01455-5

Other articles of this Issue 11/2019

Clinical Research in Cardiology 11/2019 Go to the issue