Skip to main content
Top
Published in: International Urogynecology Journal 12/2016

01-12-2016 | IUJ Video

Removal of obstructing synthetic sling from a urethra: English and Spanish version

Authors: Javier Pizarro-Berdichevsky, Michelle P. Goldman, Howard B. Goldman

Published in: International Urogynecology Journal | Issue 12/2016

Login to get access

Abstract

Introduction and hypothesis

Urethral perforations after synthetic midurethral sling (MUS) placement are uncommon. Transvaginal removal is an option. The objective of this English and Spanish video is to demonstrate removal of an MUS that had perforated the urethra and the concomitant urethral reconstruction.

Methods

A 66-year-old woman with a history of an anterior and posterior colporrhaphy and a retropubic MUS 12 years earlier presented with difficulty voiding, recurrent urinary tract infections, and mild stress incontinence (SUI). Physical examination revealed tenderness on the anterior vaginal wall (AVW) without mesh extrusion. Cystourethroscopy showed urethral perforation, distal to the bladder neck and urodynamics demonstrated an obstructive pattern. The patient wished to undergo transvaginal sling removal and reconstruction.

Results

The mesh was deep in the AVW perforating the urethra and the vaginal portion was completely removed. The video demonstrates several tips on how to remove a perforating MUS and subsequent urethral reconstruction. Ten months postoperatively the force of stream returned to normal, with no further UTIs, no evidence of fistula, and rare SUI.

Conclusions

Urethral perforation with an MUS can be successfully treated with removal of any mesh in proximity to the urethra and urethral reconstruction via a completely transvaginal approach.
Appendix
Available only for authorised users
Literature
1.
go back to reference Novara G, Galfano A, Boscolo-Berto R, et al. Complication rates of tension-free midurethral slings in the treatment of female stress urinary incontinence: a systematic review and meta-analysis of randomized controlled trials comparing tension-free midurethral tapes to other surgical procedures and different devices. Eur Urol. 2008;53(2):288–308.CrossRefPubMed Novara G, Galfano A, Boscolo-Berto R, et al. Complication rates of tension-free midurethral slings in the treatment of female stress urinary incontinence: a systematic review and meta-analysis of randomized controlled trials comparing tension-free midurethral tapes to other surgical procedures and different devices. Eur Urol. 2008;53(2):288–308.CrossRefPubMed
2.
go back to reference Abed H, Rahn DD, Lowenstein L, Balk EM, Clemons JL, Rogers RG. Incidence and management of graft erosion, wound granulation, and dyspareunia following vaginal prolapse repair with graft materials: a systematic review. Int Urogynecol J. 2011;22(7):789–98.CrossRefPubMed Abed H, Rahn DD, Lowenstein L, Balk EM, Clemons JL, Rogers RG. Incidence and management of graft erosion, wound granulation, and dyspareunia following vaginal prolapse repair with graft materials: a systematic review. Int Urogynecol J. 2011;22(7):789–98.CrossRefPubMed
3.
go back to reference Freilich DA, Rovner ES. Removal of polypropylene sling mesh from the urethra: an anatomic technique. Urology. 2015;86(1):196–9.CrossRefPubMed Freilich DA, Rovner ES. Removal of polypropylene sling mesh from the urethra: an anatomic technique. Urology. 2015;86(1):196–9.CrossRefPubMed
4.
go back to reference Werner M, Najjari L, Schuessler B. Transurethral resection of tension-free vaginal tape penetrating the urethra. Obstet Gynecol. 2003;102(5 Pt 1):1034–6.PubMed Werner M, Najjari L, Schuessler B. Transurethral resection of tension-free vaginal tape penetrating the urethra. Obstet Gynecol. 2003;102(5 Pt 1):1034–6.PubMed
5.
go back to reference Haylen BT, Freeman RM, Swift SE, et al. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) and grafts in female pelvic floor surgery. Int Urogynecol J. 2011;22(1):3–15.CrossRefPubMed Haylen BT, Freeman RM, Swift SE, et al. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint terminology and classification of the complications related directly to the insertion of prostheses (meshes, implants, tapes) and grafts in female pelvic floor surgery. Int Urogynecol J. 2011;22(1):3–15.CrossRefPubMed
6.
go back to reference American College of Obstetricians and Gynecologists. ACOG Committee Opinion. Number 372. July 2007. The role of cystourethroscopy in the generalist obstetrician-gynecologist practice. Obstet Gynecol. 2007;110(1):221–4.CrossRef American College of Obstetricians and Gynecologists. ACOG Committee Opinion. Number 372. July 2007. The role of cystourethroscopy in the generalist obstetrician-gynecologist practice. Obstet Gynecol. 2007;110(1):221–4.CrossRef
Metadata
Title
Removal of obstructing synthetic sling from a urethra: English and Spanish version
Authors
Javier Pizarro-Berdichevsky
Michelle P. Goldman
Howard B. Goldman
Publication date
01-12-2016
Publisher
Springer London
Published in
International Urogynecology Journal / Issue 12/2016
Print ISSN: 0937-3462
Electronic ISSN: 1433-3023
DOI
https://doi.org/10.1007/s00192-016-3098-1

Other articles of this Issue 12/2016

International Urogynecology Journal 12/2016 Go to the issue

Letter to the Editor

Reply to the Editor