Skip to main content
Top
Published in: Pediatric Cardiology 1/2018

01-01-2018 | Original Article

Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair

Authors: Antoine Legendre, D. Bonnet, L. Bosquet

Published in: Pediatric Cardiology | Issue 1/2018

Login to get access

Abstract

Global ventricular response to exercise may be useful in follow-up of patients with residual right outflow tract lesions after congenital heart disease repair. In this context, impedance cardiography is considered accurate for stroke volume (SV) measurement during exercise testing, however, to date, only partial assessment of its reliability has been reported. We retrospectively evaluated relative and absolute reliability of peak SV by impedance cardiography during exercise using intraclass correlation (ICC) and standard error of measurement (SEM) in this population. Peak SV was measured in 30 young patients (mean age 14.4 years ± 2.1) with right ventricular outflow tract reconstruction who underwent two cardiopulmonary exercise tests at a mean one-year interval. SV was measured using a signal morphology impedance cardiography analysis device (PhysioFlow®) and was indexed to body surface area. ICC of peak indexed SV measurement was 0.80 and SEM was 10.5%. High heterogeneity was seen when comparing patients according to peak indexed SV; in patients with peak SV < 50 ml/m2 (15 patients), ICC rose to 0.95 and SEM dropped to 2.7%, while in patients with a peak SV > 50 ml/m2 relative and absolute reliability decreased (ICC = 0.45, SEM = 12.2%). Peak exercise SV assessment by a PhysioFlow® device represents a highly reliable method in patients with residual right outflow tract lesions after congenital heart disease repair, especially in patients with peak SV < 50 ml/m2. In this latter group, a peak SV decrease > 7.3% (corresponding to the minimum “true” difference) should be considered a clinically-relevant decrease in global ventricular performance and taken into account when deciding whether to perform residual lesion removal.
Literature
1.
go back to reference Legendre A, Richard R, Pontnau F, Jais JP, Dufour M, Grenier O et al (2016) Usefulness of maximal oxygen pulse in timing of pulmonary valve replacement in patients with isolated pulmonary regurgitation. Cardiol Young 26(7):1310–1318CrossRefPubMed Legendre A, Richard R, Pontnau F, Jais JP, Dufour M, Grenier O et al (2016) Usefulness of maximal oxygen pulse in timing of pulmonary valve replacement in patients with isolated pulmonary regurgitation. Cardiol Young 26(7):1310–1318CrossRefPubMed
2.
go back to reference Eynon N, Sagiv M, Amir O, Ben-Sira D, Goldhammer E, Amir R. The effect of long-term beta-adrenergic receptor blockade on the oxygen delivery and extraction relationship in patients with coronary artery disease. J Cardiopulm Rehabil Prev. 2008; 28(3):189–94. Eur J Appl Physiol. 2001, 85(3–4): 202–7 Eynon N, Sagiv M, Amir O, Ben-Sira D, Goldhammer E, Amir R. The effect of long-term beta-adrenergic receptor blockade on the oxygen delivery and extraction relationship in patients with coronary artery disease. J Cardiopulm Rehabil Prev. 2008; 28(3):189–94. Eur J Appl Physiol. 2001, 85(3–4): 202–7
3.
go back to reference Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B et al (2000) A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol 82(4):313–320CrossRefPubMed Charloux A, Lonsdorfer-Wolf E, Richard R, Lampert E, Oswald-Mammosser M, Mettauer B et al (2000) A new impedance cardiograph device for the non-invasive evaluation of cardiac output at rest and during exercise: comparison with the “direct” Fick method. Eur J Appl Physiol 82(4):313–320CrossRefPubMed
4.
go back to reference Welsman J, Bywater K, Farr C, Welford D, Armstrong N (2005) Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children. Eur J Appl Physiol 94(3):228–234CrossRefPubMed Welsman J, Bywater K, Farr C, Welford D, Armstrong N (2005) Reliability of peak VO(2) and maximal cardiac output assessed using thoracic bioimpedance in children. Eur J Appl Physiol 94(3):228–234CrossRefPubMed
5.
go back to reference Duncan GE, Howley ET, Johnson BN (1997) Applicability of VO2max criteria: discontinuous versus continuous protocols. Med Sci Sports Exerc 29(2):273–278CrossRefPubMed Duncan GE, Howley ET, Johnson BN (1997) Applicability of VO2max criteria: discontinuous versus continuous protocols. Med Sci Sports Exerc 29(2):273–278CrossRefPubMed
6.
go back to reference Wasserman K, Hansen JE, Sue DY, Casaburi R, Whipp BJ (1999) Principles of exercise testing and interpretation. Lippincott, Philadelphia, p 193 Wasserman K, Hansen JE, Sue DY, Casaburi R, Whipp BJ (1999) Principles of exercise testing and interpretation. Lippincott, Philadelphia, p 193
7.
go back to reference Richard R, Lonsdorfer-Wolf E, Charloux A, Doutreleau S, Buchheit M, Oswald-Mammosser M et al (2001) Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device. Eur J Appl Physiol 85(3–4):202–207CrossRefPubMed Richard R, Lonsdorfer-Wolf E, Charloux A, Doutreleau S, Buchheit M, Oswald-Mammosser M et al (2001) Non-invasive cardiac output evaluation during a maximal progressive exercise test, using a new impedance cardiograph device. Eur J Appl Physiol 85(3–4):202–207CrossRefPubMed
8.
go back to reference Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Erlbaum, Hillsdale Cohen J (1988) Statistical power analysis for the behavioral sciences, 2nd edn. Erlbaum, Hillsdale
9.
go back to reference Atkinson G, Nevill AM (1998) Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 26(4):217–238CrossRefPubMed Atkinson G, Nevill AM (1998) Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med 26(4):217–238CrossRefPubMed
10.
go back to reference Dupuy O, Mekary S, Berryman N, Bherer L, Audiffren M, Bosquet L (2012) Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation. Clin Physiol Funct Imaging 32(4):296–304CrossRefPubMed Dupuy O, Mekary S, Berryman N, Bherer L, Audiffren M, Bosquet L (2012) Reliability of heart rate measures used to assess post-exercise parasympathetic reactivation. Clin Physiol Funct Imaging 32(4):296–304CrossRefPubMed
11.
go back to reference Munro B (1997) Statistical methods for health care research, 3rd edn. Lippincott, New York, pp 1–444 Munro B (1997) Statistical methods for health care research, 3rd edn. Lippincott, New York, pp 1–444
12.
go back to reference Currier D (1990) Elements of research in physical therapy. Williams and Wilkins, Baltimore Currier D (1990) Elements of research in physical therapy. Williams and Wilkins, Baltimore
13.
go back to reference Weir JP (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 19(1):231–240PubMed Weir JP (2005) Quantifying test-retest reliability using the intraclass correlation coefficient and the SEM. J Strength Cond Res 19(1):231–240PubMed
14.
go back to reference Schultz MG, Climie RED, Nikolic SB, Ahuja KD, Sharman JE (2012) Reproducibility of cardiac output derived by impedance cardiography during postural changes and exercise. Artery Res 6(2):78–84CrossRef Schultz MG, Climie RED, Nikolic SB, Ahuja KD, Sharman JE (2012) Reproducibility of cardiac output derived by impedance cardiography during postural changes and exercise. Artery Res 6(2):78–84CrossRef
15.
go back to reference Hillis DL, Firth BG, Winniford MD (1985) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768CrossRefPubMed Hillis DL, Firth BG, Winniford MD (1985) Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 56:764–768CrossRefPubMed
16.
go back to reference Bergersen L, Gauvreau K, Jenkins KJ, Lock JE (2008) Adverse event rates in congenital cardiac catheterization: a new understanding of risks. Congenit Heart Dis. 3(2):90–105CrossRefPubMed Bergersen L, Gauvreau K, Jenkins KJ, Lock JE (2008) Adverse event rates in congenital cardiac catheterization: a new understanding of risks. Congenit Heart Dis. 3(2):90–105CrossRefPubMed
17.
go back to reference Rowland TW, Melanson EL, Popowski BE, Ferrone LC (1998) Test-retest reproducibility of maximum cardiac output by Doppler echocardiography. Am J Cardiol 81(10):1228–1230CrossRefPubMed Rowland TW, Melanson EL, Popowski BE, Ferrone LC (1998) Test-retest reproducibility of maximum cardiac output by Doppler echocardiography. Am J Cardiol 81(10):1228–1230CrossRefPubMed
18.
go back to reference Vinet A, Nottin S, Lecoq AM, Guenon P, Obert P (2001) Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults. Int J Sports Med 22(6):437–441CrossRefPubMed Vinet A, Nottin S, Lecoq AM, Guenon P, Obert P (2001) Reproducibility of cardiac output measurements by Doppler echocardiography in prepubertal children and adults. Int J Sports Med 22(6):437–441CrossRefPubMed
19.
go back to reference Roest AA, Kunz P, Lamb HJ, Helbing WA, van der Wall EE, de Roos A (2001) Biventricular response to supine physical exercise in young adults assessed with ultrafast magnetic resonance imaging. Am J Cardiol 87(5):601–605CrossRefPubMed Roest AA, Kunz P, Lamb HJ, Helbing WA, van der Wall EE, de Roos A (2001) Biventricular response to supine physical exercise in young adults assessed with ultrafast magnetic resonance imaging. Am J Cardiol 87(5):601–605CrossRefPubMed
20.
go back to reference Rowland T, Mannie E, Gawle L (2001) Dynamics of left ventricular diastolic filling during exercise: a Doppler echocardiographic study of boys 10 to 14 years old. Chest 120(1):145–150CrossRefPubMed Rowland T, Mannie E, Gawle L (2001) Dynamics of left ventricular diastolic filling during exercise: a Doppler echocardiographic study of boys 10 to 14 years old. Chest 120(1):145–150CrossRefPubMed
21.
go back to reference Kemps HM, Thijssen EJ, Schep G, Sleutjes BT, De Vries WR, Hoogeveen AR et al (1985) Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients. J Appl Physiol 105(6):1822–1829CrossRef Kemps HM, Thijssen EJ, Schep G, Sleutjes BT, De Vries WR, Hoogeveen AR et al (1985) Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients. J Appl Physiol 105(6):1822–1829CrossRef
22.
go back to reference Tonelli AR, Alnuaimat H, Li N, Carrie R, Mubarak KK (2011) Value of impedance cardiography in patients studied for pulmonary hypertension. Lung 189(5):369–375CrossRefPubMed Tonelli AR, Alnuaimat H, Li N, Carrie R, Mubarak KK (2011) Value of impedance cardiography in patients studied for pulmonary hypertension. Lung 189(5):369–375CrossRefPubMed
23.
go back to reference Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H (2011) A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J Cardiothorac Vasc Anesth 25(5):776–779CrossRefPubMed Taylor K, La Rotta G, McCrindle BW, Manlhiot C, Redington A, Holtby H (2011) A comparison of cardiac output by thoracic impedance and direct fick in children with congenital heart disease undergoing diagnostic cardiac catheterization. J Cardiothorac Vasc Anesth 25(5):776–779CrossRefPubMed
24.
go back to reference Buheitel G, Scharf J, Hofbeck M, Singer H. Determination of heart time volume using the Fick principle in the early postoperative phase after correction of congenital heart defects. Comparison of the calculation of arterio-mixed venous oxygen differences and pulmonary oxygen uptake with the calculation of arterial-central venous oxygen differences and pulmonary oxygen uptake. Klin Padiatr. 1994; 206(3):151–6 Buheitel G, Scharf J, Hofbeck M, Singer H. Determination of heart time volume using the Fick principle in the early postoperative phase after correction of congenital heart defects. Comparison of the calculation of arterio-mixed venous oxygen differences and pulmonary oxygen uptake with the calculation of arterial-central venous oxygen differences and pulmonary oxygen uptake. Klin Padiatr. 1994; 206(3):151–6
25.
go back to reference Ebrahim M, Hegde S, Printz B, Abcede M, Proudfoot JA, Davis C (2016) Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease. Pediatr Cardiol 37(8):1453–1457CrossRefPubMed Ebrahim M, Hegde S, Printz B, Abcede M, Proudfoot JA, Davis C (2016) Evaluation of Impedance Cardiography for Measurement of Stroke Volume in Congenital Heart Disease. Pediatr Cardiol 37(8):1453–1457CrossRefPubMed
26.
go back to reference Legendre A, Guillot A, Ladouceur M, Bonnet D (2017) Usefulness of stroke volume monitoring during upright ramp incremental cycle exercise in young patients with Fontan circulation. Int J Cardiol 15(227):625–630CrossRef Legendre A, Guillot A, Ladouceur M, Bonnet D (2017) Usefulness of stroke volume monitoring during upright ramp incremental cycle exercise in young patients with Fontan circulation. Int J Cardiol 15(227):625–630CrossRef
27.
go back to reference Martino M, Gledhill N, Jamnik V (2002) High VO2max with no history of training is primarily due to high blood volume. Med Sci Sports Exerc 34(6):966–971CrossRefPubMed Martino M, Gledhill N, Jamnik V (2002) High VO2max with no history of training is primarily due to high blood volume. Med Sci Sports Exerc 34(6):966–971CrossRefPubMed
28.
go back to reference Kipps AK, Graham DA, Harrild DM, Lewis E, Powell AJ, Rhodes J (2011) Longitudinal exercise capacity of patients with repaired tetralogy of fallot. Am J Cardiol 108(1):99–105CrossRefPubMed Kipps AK, Graham DA, Harrild DM, Lewis E, Powell AJ, Rhodes J (2011) Longitudinal exercise capacity of patients with repaired tetralogy of fallot. Am J Cardiol 108(1):99–105CrossRefPubMed
Metadata
Title
Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair
Authors
Antoine Legendre
D. Bonnet
L. Bosquet
Publication date
01-01-2018
Publisher
Springer US
Published in
Pediatric Cardiology / Issue 1/2018
Print ISSN: 0172-0643
Electronic ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-017-1725-3

Other articles of this Issue 1/2018

Pediatric Cardiology 1/2018 Go to the issue