Skip to main content
Top
Published in: Abdominal Radiology 5/2017

01-05-2017

Radiographic capsule-based system for non-cathartic colorectal cancer screening

Authors: Yoav Kimchy, Ronen Lifshitz, Shlomo Lewkowitz, Guiseppe Bertuccio, Nadir Arber, Nathan Gluck, Perry J. Pickhardt

Published in: Abdominal Radiology | Issue 5/2017

Login to get access

Abstract

Many patients are reluctant to undergo optical colonoscopy for colorectal cancer screening. The Check-Cap colon imaging system is a non-invasive test that comprises an ingestible imaging capsule that emits and detects ultra-low-dose radiation. The capsule generates a 3D reconstruction of the colonic lumen for detection of polyps and cancer. Preliminary preclinical and clinical testing has demonstrated safety and feasibility. Mean radiation dose is estimated at 0.04 mSv. In conclusion, we describe a novel capsule-based, patient-friendly colorectal test that holds potential for non-invasive screening.
Literature
1.
go back to reference Torre LA, Bray F, Siegel RL, et al. (2015) Global cancer statistics, 2012. CA 65:87–108PubMed Torre LA, Bray F, Siegel RL, et al. (2015) Global cancer statistics, 2012. CA 65:87–108PubMed
2.
go back to reference Levin B, Lieberman DA, McFarland B, et al. (2008) Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology. CA 58:130–160PubMed Levin B, Lieberman DA, McFarland B, et al. (2008) Screening and surveillance for the early detection of colorectal cancer and adenomatous polyps, 2008: a joint guideline from the American Cancer Society, the US Multi-Society Task Force on Colorectal Cancer, and the American College of Radiology. CA 58:130–160PubMed
3.
go back to reference Pickhardt PJ (2016) Emerging stool-based and blood-based non-invasive DNA tests for colorectal cancer screening: the importance of cancer prevention in addition to cancer detection. Abdom Radiol Pickhardt PJ (2016) Emerging stool-based and blood-based non-invasive DNA tests for colorectal cancer screening: the importance of cancer prevention in addition to cancer detection. Abdom Radiol
4.
go back to reference Pickhardt PJ (2015) CT colonography for population screening: ready for prime time? Dig Dis Sci 60:647–659CrossRef Pickhardt PJ (2015) CT colonography for population screening: ready for prime time? Dig Dis Sci 60:647–659CrossRef
5.
go back to reference Ranasinghe I, Parzynski CS, Searfoss R, et al. (2016) Differences in colonoscopy quality among facilities: development of a post-colonoscopy risk-standardized rate of unplanned hospital visits. Gastroenterology 150:103–113CrossRef Ranasinghe I, Parzynski CS, Searfoss R, et al. (2016) Differences in colonoscopy quality among facilities: development of a post-colonoscopy risk-standardized rate of unplanned hospital visits. Gastroenterology 150:103–113CrossRef
6.
go back to reference Rosenthal E (2013) The $2.7 trillion medical bill: colonoscopies explain why U.S. leads the world in health expenditures. The New York Times Rosenthal E (2013) The $2.7 trillion medical bill: colonoscopies explain why U.S. leads the world in health expenditures. The New York Times
7.
go back to reference Bertuccio G, Caccia S, Macera D, et al. (2013) A mixed-signal ASIC for CdTe/CdZnTe detectors readout in battery powered capsule for colon 3D-imaging. IEEE Trans Nucl Sci 60:3872–3878CrossRef Bertuccio G, Caccia S, Macera D, et al. (2013) A mixed-signal ASIC for CdTe/CdZnTe detectors readout in battery powered capsule for colon 3D-imaging. IEEE Trans Nucl Sci 60:3872–3878CrossRef
8.
go back to reference Kimchy et al. Intra-lumen polyp detection, US patent 7,787,926 Kimchy et al. Intra-lumen polyp detection, US patent 7,787,926
9.
go back to reference Baum et al. Estimation of distances and size of lesions in the colon with an imaging capsule, US patent 9,037,219 Baum et al. Estimation of distances and size of lesions in the colon with an imaging capsule, US patent 9,037,219
10.
go back to reference Gluck N, Shpak B, Brun R, et al. (2016) A novel prepless X-ray imaging capsule for colon cancer screening. Gut 65:371–373CrossRef Gluck N, Shpak B, Brun R, et al. (2016) A novel prepless X-ray imaging capsule for colon cancer screening. Gut 65:371–373CrossRef
Metadata
Title
Radiographic capsule-based system for non-cathartic colorectal cancer screening
Authors
Yoav Kimchy
Ronen Lifshitz
Shlomo Lewkowitz
Guiseppe Bertuccio
Nadir Arber
Nathan Gluck
Perry J. Pickhardt
Publication date
01-05-2017
Publisher
Springer US
Published in
Abdominal Radiology / Issue 5/2017
Print ISSN: 2366-004X
Electronic ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-016-1026-y

Other articles of this Issue 5/2017

Abdominal Radiology 5/2017 Go to the issue

Classics in Abdominal Imaging

The T2-dark spot sign

Obesity Clinical Trial Summary

At a glance: The STEP trials

A round-up of the STEP phase 3 clinical trials evaluating semaglutide for weight loss in people with overweight or obesity.

Developed by: Springer Medicine

Highlights from the ACC 2024 Congress

Year in Review: Pediatric cardiology

Watch Dr. Anne Marie Valente present the last year's highlights in pediatric and congenital heart disease in the official ACC.24 Year in Review session.

Year in Review: Pulmonary vascular disease

The last year's highlights in pulmonary vascular disease are presented by Dr. Jane Leopold in this official video from ACC.24.

Year in Review: Valvular heart disease

Watch Prof. William Zoghbi present the last year's highlights in valvular heart disease from the official ACC.24 Year in Review session.

Year in Review: Heart failure and cardiomyopathies

Watch this official video from ACC.24. Dr. Biykem Bozkurt discuss last year's major advances in heart failure and cardiomyopathies.