Quantified frequency-domain optical coherence tomography analysis for the thin-high signals on restenotic tissue after paclitaxel-coated balloon angioplasty

Authors: Hideyuki Kawashima, Nobuaki Suzuki, Taiga Katayama, Shinji Takahashi, Ryuta Okabe, Shintaro Takamura, Yusuke Watanabe, Hiroyuki Kyono, Ken Kozuma

Published in: Heart and Vessels | Issue 6/2018

Login to get access

Abstract

Thin-high signals (THS), detectable by optical coherence tomography (OCT), represent the paclitaxel coverage of in-stent restenotic tissue. This study was conducted to assess the relationship between THS and angiographic outcomes by means of quantified post-procedural frequency-domain OCT (FD-OCT) analysis. From January 2014 to July 2016, 41 patients underwent FD-OCT-guided percutaneous coronary intervention using paclitaxel-coated balloon (PCB) to prevent in-stent restenosis. Of these, we retrospectively enrolled 32 patients (38 lesions) who underwent a 6- to 9-month follow-up angiogram. THS were assessed quantitatively, as THS length and lumen perimeter length were measured using semi-automated software; %THS was calculated by the following formula; total THS area/lumen perimeter area × 100. THS were detected in all 38 lesions that had undergone PCB angioplasty. THS and %THS were significantly higher in lesions without binary restenosis (3.34 ± 2.11 vs. 11.48 ± 8.53 mm2, p = 0.001 and 1.49 ± 0.73 vs. 4.42 ± 2.71%, p = 0.001, respectively). Values for THS, which indicates the paclitaxel coverage on restenotic tissue, are associated with reducing restenosis after PCB for in-stent restenosis.
Literature
1.
go back to reference Byrne RA, Neumann FJ, Mehilli J, Pinieck S, Wolff B, Tiroch K, Schulz S, Fusaro M, Ott I, Ibrahim T, Hausleiter J, Valina C, Pache J, Laugwitz KL, Massberg S, Kastrati A, Investigators I-D (2013) Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial. Lancet 381(9865):461–467. https://doi.org/10.1016/S0140-6736(12)61964-3 CrossRefPubMed Byrne RA, Neumann FJ, Mehilli J, Pinieck S, Wolff B, Tiroch K, Schulz S, Fusaro M, Ott I, Ibrahim T, Hausleiter J, Valina C, Pache J, Laugwitz KL, Massberg S, Kastrati A, Investigators I-D (2013) Paclitaxel-eluting balloons, paclitaxel-eluting stents, and balloon angioplasty in patients with restenosis after implantation of a drug-eluting stent (ISAR-DESIRE 3): a randomised, open-label trial. Lancet 381(9865):461–467. https://​doi.​org/​10.​1016/​S0140-6736(12)61964-3 CrossRefPubMed
2.
go back to reference Lupi A, Rognoni A, Secco GG, Porto I, Nardi F, Lazzero M, Rossi L, Parisi R, Fattori R, Genoni G, Rosso R, Stella PR, Sheiban I, Bolognese L, Liistro F, Bongo AS, Agostoni P (2013) Drug eluting balloon versus drug eluting stent in percutaneous coronary interventions: insights from a meta-analysis of 1462 patients. Int J Cardiol 168(5):4608–4616. https://doi.org/10.1016/j.ijcard.2013.07.161 CrossRefPubMed Lupi A, Rognoni A, Secco GG, Porto I, Nardi F, Lazzero M, Rossi L, Parisi R, Fattori R, Genoni G, Rosso R, Stella PR, Sheiban I, Bolognese L, Liistro F, Bongo AS, Agostoni P (2013) Drug eluting balloon versus drug eluting stent in percutaneous coronary interventions: insights from a meta-analysis of 1462 patients. Int J Cardiol 168(5):4608–4616. https://​doi.​org/​10.​1016/​j.​ijcard.​2013.​07.​161 CrossRefPubMed
4.
go back to reference Yoneyama K, Koyama K, Tanabe Y, Mitarai T, Kamijima R, Kuwata S, Yamazaki H, Nakano E, Kongoji K, Harada T, Akashi YJ (2014) Coronary angioscopy and optical coherence tomography for confirmation of drug-coated neointimal plaque after paclitaxel-coated balloon angioplasty for in-stent restenosis. Int J Cardiol 176(3):1207–1209. https://doi.org/10.1016/j.ijcard.2014.07.224 CrossRefPubMed Yoneyama K, Koyama K, Tanabe Y, Mitarai T, Kamijima R, Kuwata S, Yamazaki H, Nakano E, Kongoji K, Harada T, Akashi YJ (2014) Coronary angioscopy and optical coherence tomography for confirmation of drug-coated neointimal plaque after paclitaxel-coated balloon angioplasty for in-stent restenosis. Int J Cardiol 176(3):1207–1209. https://​doi.​org/​10.​1016/​j.​ijcard.​2014.​07.​224 CrossRefPubMed
6.
go back to reference Hinohara T, Rowe MH, Robertson GC, Selmon MR, Braden L, Leggett JH, Vetter JW, Simpson JB (1991) Effect of lesion characteristics on outcome of directional coronary atherectomy. J Am Coll Cardiol 17(5):1112–1120CrossRefPubMed Hinohara T, Rowe MH, Robertson GC, Selmon MR, Braden L, Leggett JH, Vetter JW, Simpson JB (1991) Effect of lesion characteristics on outcome of directional coronary atherectomy. J Am Coll Cardiol 17(5):1112–1120CrossRefPubMed
7.
go back to reference Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, Hamasaki N, Horiuchi H, Ohishi H (1988) Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol 12(3):616–623CrossRefPubMed Nobuyoshi M, Kimura T, Nosaka H, Mioka S, Ueno K, Yokoi H, Hamasaki N, Horiuchi H, Ohishi H (1988) Restenosis after successful percutaneous transluminal coronary angioplasty: serial angiographic follow-up of 229 patients. J Am Coll Cardiol 12(3):616–623CrossRefPubMed
8.
go back to reference Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia-Garcia HM, van Soest G, van der Giessen W, Regar E (2009) Optical coherence tomography patterns of stent restenosis. Am Heart J 158(2):284–293CrossRefPubMed Gonzalo N, Serruys PW, Okamura T, van Beusekom HM, Garcia-Garcia HM, van Soest G, van der Giessen W, Regar E (2009) Optical coherence tomography patterns of stent restenosis. Am Heart J 158(2):284–293CrossRefPubMed
9.
go back to reference Suzuki N, Kozuma K, Kyono H, Nakaya H, Nishide S, Mitsui M, Nara Y, Kawashima H, Nomura T, Yamamoto H, Sasajima Y, Kondo F, Isshiki T (2016) The clinical characteristics and prognosis of lesions with in-stent eccentric tissue proliferation and strong signal attenuation detected by optimal coherence tomography. Cardiovasc Interv Ther 31(3):210–217. https://doi.org/10.1007/s12928-015-0369-6 (Epub 2015 Nov 25) CrossRefPubMed Suzuki N, Kozuma K, Kyono H, Nakaya H, Nishide S, Mitsui M, Nara Y, Kawashima H, Nomura T, Yamamoto H, Sasajima Y, Kondo F, Isshiki T (2016) The clinical characteristics and prognosis of lesions with in-stent eccentric tissue proliferation and strong signal attenuation detected by optimal coherence tomography. Cardiovasc Interv Ther 31(3):210–217. https://​doi.​org/​10.​1007/​s12928-015-0369-6 (Epub 2015 Nov 25) CrossRefPubMed
10.
go back to reference Ali ZA, Maehara A, Genereux P, Shlofmitz RA, Fabbiocchi F, Nazif TM, Guagliumi G, Meraj PM, Alfonso F, Samady H, Akasaka T, Carlson EB, Leesar MA, Matsumura M, Ozan MO, Mintz GS, Ben-Yehuda O, Stone GW, Investigators IIOP (2016) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. Lancet. https://doi.org/10.1016/S0140-6736(16)31922-5 PubMedCentralCrossRefPubMed Ali ZA, Maehara A, Genereux P, Shlofmitz RA, Fabbiocchi F, Nazif TM, Guagliumi G, Meraj PM, Alfonso F, Samady H, Akasaka T, Carlson EB, Leesar MA, Matsumura M, Ozan MO, Mintz GS, Ben-Yehuda O, Stone GW, Investigators IIOP (2016) Optical coherence tomography compared with intravascular ultrasound and with angiography to guide coronary stent implantation (ILUMIEN III: OPTIMIZE PCI): a randomised controlled trial. Lancet. https://​doi.​org/​10.​1016/​S0140-6736(16)31922-5 PubMedCentralCrossRefPubMed
11.
go back to reference Tada T, Kadota K, Hosogi S, Miyake K, Ohya M, Amano H, Izawa Y, Kanazawa T, Kubo S, Ichinohe T, Hyoudou Y, Hayakawa Y, Sabbah MM, Otsuru S, Hasegawa D, Habara S, Tanaka H, Fuku Y, Katoh H, Goto T, Mitsudo K (2015) Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation. Eur Heart J Cardiovasc Imaging 16(10):1101–1111. https://doi.org/10.1093/ehjci/jev031 CrossRefPubMed Tada T, Kadota K, Hosogi S, Miyake K, Ohya M, Amano H, Izawa Y, Kanazawa T, Kubo S, Ichinohe T, Hyoudou Y, Hayakawa Y, Sabbah MM, Otsuru S, Hasegawa D, Habara S, Tanaka H, Fuku Y, Katoh H, Goto T, Mitsudo K (2015) Association between tissue characteristics assessed with optical coherence tomography and mid-term results after percutaneous coronary intervention for in-stent restenosis lesions: a comparison between balloon angioplasty, paclitaxel-coated balloon dilatation, and drug-eluting stent implantation. Eur Heart J Cardiovasc Imaging 16(10):1101–1111. https://​doi.​org/​10.​1093/​ehjci/​jev031 CrossRefPubMed
12.
go back to reference Authors/Task Force m, Windecker S, Kolh P, Alfonso F, Collet JP, Cremer J, Falk V, Filippatos G, Hamm C, Head SJ, Juni P, Kappetein AP, Kastrati A, Knuuti J, Landmesser U, Laufer G, Neumann FJ, Richter DJ, Schauerte P, Sousa Uva M, Stefanini GG, Taggart DP, Torracca L, Valgimigli M, Wijns W, Witkowski A (2014) 2014 ESC/EACTS Guidelines on myocardial revascularization: the Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 35(37):2541–2619. https://doi.org/10.1093/eurheartj/ehu278 Authors/Task Force m, Windecker S, Kolh P, Alfonso F, Collet JP, Cremer J, Falk V, Filippatos G, Hamm C, Head SJ, Juni P, Kappetein AP, Kastrati A, Knuuti J, Landmesser U, Laufer G, Neumann FJ, Richter DJ, Schauerte P, Sousa Uva M, Stefanini GG, Taggart DP, Torracca L, Valgimigli M, Wijns W, Witkowski A (2014) 2014 ESC/EACTS Guidelines on myocardial revascularization: the Task Force on Myocardial Revascularization of the European Society of Cardiology (ESC) and the European Association for Cardio-Thoracic Surgery (EACTS) developed with the special contribution of the European Association of Percutaneous Cardiovascular Interventions (EAPCI). Eur Heart J 35(37):2541–2619. https://​doi.​org/​10.​1093/​eurheartj/​ehu278
13.
go back to reference Alfonso F, Perez-Vizcayno MJ, Cardenas A, Garcia del Blanco B, Garcia-Touchard A, Lopez-Minguez JR, Benedicto A, Masotti M, Zueco J, Iniguez A, Velazquez M, Moreno R, Mainar V, Dominguez A, Pomar F, Melgares R, Rivero F, Jimenez-Quevedo P, Gonzalo N, Fernandez C, Macaya C, Investigators RIS (2015) A prospective randomized trial of drug-eluting balloons versus everolimus-eluting stents in patients with in-stent restenosis of drug-eluting stents: the RIBS IV randomized clinical trial. J Am Coll Cardiol 66(1):23–33. https://doi.org/10.1016/j.jacc.2015.04.063 CrossRefPubMed Alfonso F, Perez-Vizcayno MJ, Cardenas A, Garcia del Blanco B, Garcia-Touchard A, Lopez-Minguez JR, Benedicto A, Masotti M, Zueco J, Iniguez A, Velazquez M, Moreno R, Mainar V, Dominguez A, Pomar F, Melgares R, Rivero F, Jimenez-Quevedo P, Gonzalo N, Fernandez C, Macaya C, Investigators RIS (2015) A prospective randomized trial of drug-eluting balloons versus everolimus-eluting stents in patients with in-stent restenosis of drug-eluting stents: the RIBS IV randomized clinical trial. J Am Coll Cardiol 66(1):23–33. https://​doi.​org/​10.​1016/​j.​jacc.​2015.​04.​063 CrossRefPubMed
14.
go back to reference Sabate M, Costa MA, Kozuma K, Kay IP, van der Giessen WJ, Coen VL, Ligthart JM, Serrano P, Levendag PC, Serruys PW (2000) Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy. Circulation 101(21):2467–2471CrossRefPubMed Sabate M, Costa MA, Kozuma K, Kay IP, van der Giessen WJ, Coen VL, Ligthart JM, Serrano P, Levendag PC, Serruys PW (2000) Geographic miss: a cause of treatment failure in radio-oncology applied to intracoronary radiation therapy. Circulation 101(21):2467–2471CrossRefPubMed
17.
go back to reference Scheller B, Speck U, Schmitt A, Bohm M, Nickenig G (2003) Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation. J Am Coll Cardiol 42(8):1415–1420CrossRefPubMed Scheller B, Speck U, Schmitt A, Bohm M, Nickenig G (2003) Addition of paclitaxel to contrast media prevents restenosis after coronary stent implantation. J Am Coll Cardiol 42(8):1415–1420CrossRefPubMed
Metadata
Title
Quantified frequency-domain optical coherence tomography analysis for the thin-high signals on restenotic tissue after paclitaxel-coated balloon angioplasty
Authors
Hideyuki Kawashima
Nobuaki Suzuki
Taiga Katayama
Shinji Takahashi
Ryuta Okabe
Shintaro Takamura
Yusuke Watanabe
Hiroyuki Kyono
Ken Kozuma
Publication date
01-06-2018
Publisher
Springer Japan
Published in
Heart and Vessels / Issue 6/2018
Print ISSN: 0910-8327
Electronic ISSN: 1615-2573
DOI
https://doi.org/10.1007/s00380-017-1103-3

Other articles of this Issue 6/2018

Heart and Vessels 6/2018 Go to the issue