Abstract

Objectives

To compare the accuracy of pre-surgical prostate size measurements using mpMRI and USWE with imaging-based 3D-printed patient-specific whole-mount moulds facilitated histopathology, and to assess whether size assessment varies between clinically significant and non-significant cancerous lesions including their locations in different zones of the prostate.

Methods

The study population included 202 men with clinically localised prostate cancer opting for radical surgery derived from two prospective studies. Protocol-based imaging data was used for measurement of size of prostate cancer in clinically localised disease using MRI (N = 106; USWE (N = 96). Forty-eight men overlapped between two studies and formed the validation cohort. The primary outcome of this study was to assess the accuracy of pre-surgical prostate cancerous size measurements using mpMRI and USWE with imaging-based 3D-printed patient-specific whole-mount moulds facilitated histopathology as a reference standard. Independent-samples T-tests were used for the continuous variables and a nonparametric Mann–Whitney U test for independent samples was applied to examine the distribution and median differences between mpMRI and USWE groups.

Results

A significant number of men had underestimation of prostate cancer using both mpMRI (82.1%; 87/106) and USWE (64.6%; 62/96). On average, tumour size was underestimated by a median size of 7 mm in mpMRI, and 1 mm in USWE. There were 327 cancerous lesions (153 with mpMRI and 174 for USWE). mpMRI and USWE underestimated the majority of cancerous lesions (108/153; 70.6%) and (88/174; 50.6%), respectively. Validation cohort data confirmed these findings MRI had a nearly 20% higher underestimation rate than USWE (χ2 (1, N = 327) = 13.580, p = 0.001); especially in the mid and apical level of the gland. Clinically non-significant cancers were underestimated in significantly higher numbers in comparison to clinically significant cancers.

Conclusions

Size measurement of prostate cancers on preoperative imaging utilising maximum linear extent technique, underestimated the extent of cancer. Further research is needed to confirm our observations using different sequences, methods and approaches for cancer size measurement.
Literature
1.
go back to reference Farrokh A, Maass N, Treu L, Heilmann T, Schäfer FKW (2019) Accuracy of tumor size measurement: comparison of B-mode ultrasound, strain elastography, and 2D and 3D shear wave elastography with histopathological lesion size. Acta Radiol 60(4):451–458CrossRefPubMed Farrokh A, Maass N, Treu L, Heilmann T, Schäfer FKW (2019) Accuracy of tumor size measurement: comparison of B-mode ultrasound, strain elastography, and 2D and 3D shear wave elastography with histopathological lesion size. Acta Radiol 60(4):451–458CrossRefPubMed
2.
go back to reference Hegde JV, Mulkern RV, Panych LP et al (2013) Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J Magn Reson Imaging 37(5):1035–1054CrossRefPubMedPubMedCentral Hegde JV, Mulkern RV, Panych LP et al (2013) Multiparametric MRI of prostate cancer: An update on state-of-the-art techniques and their performance in detecting and localizing prostate cancer. J Magn Reson Imaging 37(5):1035–1054CrossRefPubMedPubMedCentral
4.
go back to reference Priester A, Natarajan S, Le JD et al (2014) A system for evaluating magnetic resonance imaging of prostate cancer using patient-specific 3D printed molds. Am J Clin Exp Urol 2(2):127–135PubMedPubMedCentral Priester A, Natarajan S, Le JD et al (2014) A system for evaluating magnetic resonance imaging of prostate cancer using patient-specific 3D printed molds. Am J Clin Exp Urol 2(2):127–135PubMedPubMedCentral
5.
go back to reference Kim Y, Hsu ICJ, Pouliot J, Noworolski SM, Vigneron DB, Kurhanewicz J (2005) Expandable and rigid endorectal coils for prostate MRI: Impact on prostate distortion and rigid image registration. Med Phys 32(12):3569–3578CrossRefPubMed Kim Y, Hsu ICJ, Pouliot J, Noworolski SM, Vigneron DB, Kurhanewicz J (2005) Expandable and rigid endorectal coils for prostate MRI: Impact on prostate distortion and rigid image registration. Med Phys 32(12):3569–3578CrossRefPubMed
6.
go back to reference Gibson E, Gaed M, Gómez JA et al (2013) 3D prostate histology image reconstruction: quantifying the impact of tissue deformation and histology section location. J Pathol Inform 4:31CrossRefPubMedPubMedCentral Gibson E, Gaed M, Gómez JA et al (2013) 3D prostate histology image reconstruction: quantifying the impact of tissue deformation and histology section location. J Pathol Inform 4:31CrossRefPubMedPubMedCentral
7.
go back to reference Chappelow J, Bloch BN, Rofsky N et al (2011) Elastic registration of multimodal prostate MRI and histology via multiattribute combined mutual information. Med Phys 38(4):2005–2018CrossRefPubMedPubMedCentral Chappelow J, Bloch BN, Rofsky N et al (2011) Elastic registration of multimodal prostate MRI and histology via multiattribute combined mutual information. Med Phys 38(4):2005–2018CrossRefPubMedPubMedCentral
8.
go back to reference Park H, Piert MR, Khan A et al (2008) Registration methodology for histological sections and in vivo imaging of human prostate. Acad Radiol 15(8):1027–1039CrossRefPubMedPubMedCentral Park H, Piert MR, Khan A et al (2008) Registration methodology for histological sections and in vivo imaging of human prostate. Acad Radiol 15(8):1027–1039CrossRefPubMedPubMedCentral
9.
go back to reference Yamamoto H, Nir D, Vyas L et al (2014) A workflow to improve the alignment of prostate imaging with whole-mount histopathology. Acad Radiol 21(8):1009–1019CrossRefPubMed Yamamoto H, Nir D, Vyas L et al (2014) A workflow to improve the alignment of prostate imaging with whole-mount histopathology. Acad Radiol 21(8):1009–1019CrossRefPubMed
10.
go back to reference Chen LH, Ho H, Lazaro R et al (2010) Optimum slicing of radical prostatectomy specimens for correlation between histopathology and medical images. Int J Comput Assist Radiol Surg 5(5):471–487CrossRefPubMed Chen LH, Ho H, Lazaro R et al (2010) Optimum slicing of radical prostatectomy specimens for correlation between histopathology and medical images. Int J Comput Assist Radiol Surg 5(5):471–487CrossRefPubMed
11.
go back to reference Mazaheri Y, Hricak H, Fine SW et al (2009) Prostate tumor volume measurement with combined T2-weighted imaging and diffusion-weighted MR: correlation with pathologic tumor volume. Radiology 252(2):449–457CrossRefPubMedPubMedCentral Mazaheri Y, Hricak H, Fine SW et al (2009) Prostate tumor volume measurement with combined T2-weighted imaging and diffusion-weighted MR: correlation with pathologic tumor volume. Radiology 252(2):449–457CrossRefPubMedPubMedCentral
12.
go back to reference Jager GJ, Ruijter ETG, Van De Kaa CA et al (1996) Local staging of prostate cancer with endorectal MR imaging: correlation with histopathology. AJR Am J Roentgenol 166(4):845–852CrossRefPubMed Jager GJ, Ruijter ETG, Van De Kaa CA et al (1996) Local staging of prostate cancer with endorectal MR imaging: correlation with histopathology. AJR Am J Roentgenol 166(4):845–852CrossRefPubMed
14.
go back to reference Le Nobin J, Orczyk C, Deng FM et al (2014) Prostate tumour volumes: evaluation of the agreement between magnetic resonance imaging and histology using novel co-registration software. BJU Int 114(6):E105–E112CrossRefPubMedPubMedCentral Le Nobin J, Orczyk C, Deng FM et al (2014) Prostate tumour volumes: evaluation of the agreement between magnetic resonance imaging and histology using novel co-registration software. BJU Int 114(6):E105–E112CrossRefPubMedPubMedCentral
15.
go back to reference Le Nobin J, Rosenkrantz AB, Villers A et al (2015) Image guided focal therapy for magnetic resonance imaging visible prostate cancer: defining a 3-dimensional treatment margin based on magnetic resonance imaging histology co-registration analysis. J Urol 194(2):364–370CrossRefPubMedPubMedCentral Le Nobin J, Rosenkrantz AB, Villers A et al (2015) Image guided focal therapy for magnetic resonance imaging visible prostate cancer: defining a 3-dimensional treatment margin based on magnetic resonance imaging histology co-registration analysis. J Urol 194(2):364–370CrossRefPubMedPubMedCentral
16.
go back to reference Wei C, Li C, Szewczyk-Bieda M et al (2018) Performance characteristics of transrectal shear wave elastography imaging in the evaluation of clinically localized prostate cancer: a prospective study. J Urol 200(3):549–558CrossRefPubMed Wei C, Li C, Szewczyk-Bieda M et al (2018) Performance characteristics of transrectal shear wave elastography imaging in the evaluation of clinically localized prostate cancer: a prospective study. J Urol 200(3):549–558CrossRefPubMed
17.
go back to reference Szewczyk-Bieda M, Wei C, Coll K et al (2019) A multicentre parallel-group randomised trial assessing multiparametric MRI characterisation and image-guided biopsy of prostate in men suspected of having prostate cancer: MULTIPROS study protocol. Trials 20(1):1–8CrossRef Szewczyk-Bieda M, Wei C, Coll K et al (2019) A multicentre parallel-group randomised trial assessing multiparametric MRI characterisation and image-guided biopsy of prostate in men suspected of having prostate cancer: MULTIPROS study protocol. Trials 20(1):1–8CrossRef
19.
go back to reference Yoo EY, Nam SY, Choi HY, Hong MJ (2018) Agreement between MRI and pathologic analyses for determination of tumor size and correlation with immunohistochemical factors of invasive breast carcinoma. Acta Radiol 59(1):50–57CrossRefPubMed Yoo EY, Nam SY, Choi HY, Hong MJ (2018) Agreement between MRI and pathologic analyses for determination of tumor size and correlation with immunohistochemical factors of invasive breast carcinoma. Acta Radiol 59(1):50–57CrossRefPubMed
21.
go back to reference Rominger M, Berg D, Frauenfelder T, Ramaswamy A, Timmesfeld N (2016) Which factors influence MRI-pathology concordance of tumour size measurements in breast cancer? Eur Radiol 26(5):1457–1465CrossRefPubMed Rominger M, Berg D, Frauenfelder T, Ramaswamy A, Timmesfeld N (2016) Which factors influence MRI-pathology concordance of tumour size measurements in breast cancer? Eur Radiol 26(5):1457–1465CrossRefPubMed
23.
go back to reference Berg WA, Gutierrez L, NessAiver MS et al (2004) Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer. Radiology 233(3):830–849CrossRefPubMed Berg WA, Gutierrez L, NessAiver MS et al (2004) Diagnostic accuracy of mammography, clinical examination, US, and MR imaging in preoperative assessment of breast cancer. Radiology 233(3):830–849CrossRefPubMed
24.
go back to reference Padhani AR, Weinreb J, Rosenkrantz AB, Villeirs G, Turkbey B, Barentsz J (2019) Prostate imaging-reporting and data system steering committee: PI-RADS v2 status update and future directions. Eur Urol 75(3):385–396CrossRefPubMed Padhani AR, Weinreb J, Rosenkrantz AB, Villeirs G, Turkbey B, Barentsz J (2019) Prostate imaging-reporting and data system steering committee: PI-RADS v2 status update and future directions. Eur Urol 75(3):385–396CrossRefPubMed
27.
go back to reference Bercoff J, Tanter M, Fink M (2004) Supersonic shear imaging: a new technique. IEEE Trans Ultrason Ferroelectr Freq Control 51(4):396–409CrossRefPubMed Bercoff J, Tanter M, Fink M (2004) Supersonic shear imaging: a new technique. IEEE Trans Ultrason Ferroelectr Freq Control 51(4):396–409CrossRefPubMed
28.
go back to reference Bercoff J, Chaffai S, Tanter M et al (2003) In vivo breast tumor detection using transient elastography. Ultrasound Med Biol 29(10):1387–1396CrossRefPubMed Bercoff J, Chaffai S, Tanter M et al (2003) In vivo breast tumor detection using transient elastography. Ultrasound Med Biol 29(10):1387–1396CrossRefPubMed
29.
go back to reference Gilchrist M, Samuels P. Community Project Module. 2015;1–32. Gilchrist M, Samuels P. Community Project Module. 2015;1–32.
32.
go back to reference Gui C, Lau JC, Kosteniuk SE, Lee DH, Megyesi JF (2019) Radiology reporting of low-grade glioma growth underestimates tumor expansion. Acta Neurochir (Wien) 161(3):569–576CrossRefPubMed Gui C, Lau JC, Kosteniuk SE, Lee DH, Megyesi JF (2019) Radiology reporting of low-grade glioma growth underestimates tumor expansion. Acta Neurochir (Wien) 161(3):569–576CrossRefPubMed
33.
go back to reference Rosenkrantz AB, Verma S, Turkbey B (2015) Prostate cancer: top places where tumors hide on multiparametric MRI. Am J Roentgenol 204(4):W449–W456CrossRef Rosenkrantz AB, Verma S, Turkbey B (2015) Prostate cancer: top places where tumors hide on multiparametric MRI. Am J Roentgenol 204(4):W449–W456CrossRef
34.
go back to reference Rosenkrantz AB, Taneja SS (2014) Radiologist, be aware: Ten pitfalls that confound the interpretation of multiparametric prostate MRI. Am J Roentgenol 202(1):109–120CrossRef Rosenkrantz AB, Taneja SS (2014) Radiologist, be aware: Ten pitfalls that confound the interpretation of multiparametric prostate MRI. Am J Roentgenol 202(1):109–120CrossRef
35.
go back to reference Yu J, Fulcher AS, Turner MA, Cockrell CH, Cote EP, Wallace TJ (2014) Prostate cancer and its mimics at multiparametric prostate MRI. Br J Radiol 87(1037):1–7CrossRef Yu J, Fulcher AS, Turner MA, Cockrell CH, Cote EP, Wallace TJ (2014) Prostate cancer and its mimics at multiparametric prostate MRI. Br J Radiol 87(1037):1–7CrossRef
36.
go back to reference Jonmarker S, Valdman A, Lindberg A, Hellström M, Egevad L (2006) Tissue shrinkage after fixation with formalin injection of prostatectomy specimens. Virchows Arch 449(3):297–301CrossRefPubMed Jonmarker S, Valdman A, Lindberg A, Hellström M, Egevad L (2006) Tissue shrinkage after fixation with formalin injection of prostatectomy specimens. Virchows Arch 449(3):297–301CrossRefPubMed
37.
go back to reference Altman DG, Bland TM. Measurement in Medicine: The Analysis of Method Comparison Studies Author(s): D. G. Altman and J. M. Bland Published by: Wiley for the Royal Statistical Society Stable. http://www.jstor.org/stable/2987937 REFERENCES Linked references are ava. Statistician. 1983;32(3):307–17. Altman DG, Bland TM. Measurement in Medicine: The Analysis of Method Comparison Studies Author(s): D. G. Altman and J. M. Bland Published by: Wiley for the Royal Statistical Society Stable. http://​www.​jstor.​org/​stable/​2987937 REFERENCES Linked references are ava. Statistician. 1983;32(3):307–17.
40.
go back to reference Isebaert S, Van Den Bergh L, Haustermans K et al (2013) Multiparametric MRI for prostate cancer localization in correlation to whole-mount histopathology. J Magn Reson Imaging 37(6):1392–1401CrossRefPubMed Isebaert S, Van Den Bergh L, Haustermans K et al (2013) Multiparametric MRI for prostate cancer localization in correlation to whole-mount histopathology. J Magn Reson Imaging 37(6):1392–1401CrossRefPubMed
41.
go back to reference Farrokh A, Treu L, Ohlinger R, Flieger C, Maass N, Schäfer FKW (2019) A prospective two center study comparing breast cancer lesion size defined by 2D shear wave elastography, B-mode ultrasound, and mammography with the histopathological size. Ultraschall Med 40(02):212–220CrossRefPubMed Farrokh A, Treu L, Ohlinger R, Flieger C, Maass N, Schäfer FKW (2019) A prospective two center study comparing breast cancer lesion size defined by 2D shear wave elastography, B-mode ultrasound, and mammography with the histopathological size. Ultraschall Med 40(02):212–220CrossRefPubMed
43.
go back to reference Madabhushi A, Feldman MD, Metaxas DN, Tomaszeweski J, Chute D (2005) Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI. IEEE Trans Med Imaging 24(12):1611–1625CrossRefPubMed Madabhushi A, Feldman MD, Metaxas DN, Tomaszeweski J, Chute D (2005) Automated detection of prostatic adenocarcinoma from high-resolution ex vivo MRI. IEEE Trans Med Imaging 24(12):1611–1625CrossRefPubMed
44.
go back to reference Langer DL, van der Kwast TH, Evans AJ, Trachtenberg J, Wilson BC, Haider MA (2009) Prostate cancer detection with multi-parametric MRI: logistic regression analysis of quantitative T2, diffusion-weighted imaging, and dynamic contrast-enhanced MRI. J Magn Reson Imaging 30(2):327–334CrossRefPubMed Langer DL, van der Kwast TH, Evans AJ, Trachtenberg J, Wilson BC, Haider MA (2009) Prostate cancer detection with multi-parametric MRI: logistic regression analysis of quantitative T2, diffusion-weighted imaging, and dynamic contrast-enhanced MRI. J Magn Reson Imaging 30(2):327–334CrossRefPubMed
47.
go back to reference Hajdinjak T, Pelzer AE (2018) Re: What are we missing? False-negative cancers at multiparametric MR imaging of the prostate. Eur Urol 73(4):637CrossRefPubMed Hajdinjak T, Pelzer AE (2018) Re: What are we missing? False-negative cancers at multiparametric MR imaging of the prostate. Eur Urol 73(4):637CrossRefPubMed
49.
go back to reference Leddy R, Irshad A, Metcalfe A et al (2016) Comparative accuracy of preoperative tumor size assessment on mammography, sonography, and MRI: Is the accuracy affected by breast density or cancer subtype? J Clin Ultrasound 44(1):17–25CrossRefPubMed Leddy R, Irshad A, Metcalfe A et al (2016) Comparative accuracy of preoperative tumor size assessment on mammography, sonography, and MRI: Is the accuracy affected by breast density or cancer subtype? J Clin Ultrasound 44(1):17–25CrossRefPubMed
51.
go back to reference Ahmad S, Cao R, Varghese T, Bidaut L, Nabi G (2013) Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer. Surg Endosc 27(9):3280–3287CrossRefPubMed Ahmad S, Cao R, Varghese T, Bidaut L, Nabi G (2013) Transrectal quantitative shear wave elastography in the detection and characterisation of prostate cancer. Surg Endosc 27(9):3280–3287CrossRefPubMed
52.
go back to reference Zippel D, Shalmon A, Rundstein A et al (2014) Freehand Elastography for Determination of Breast cancer size: comparison with B-mode sonography and histopathologic measurement. J Ultrasound Med 33(8):1441–1446CrossRefPubMed Zippel D, Shalmon A, Rundstein A et al (2014) Freehand Elastography for Determination of Breast cancer size: comparison with B-mode sonography and histopathologic measurement. J Ultrasound Med 33(8):1441–1446CrossRefPubMed
53.
go back to reference Ko KH, Jung HK, Park AY, Koh JE, Jang H, Kim Y (2020) Accuracy of tumor size measurement on shear wave elastography (SWE): correlation with histopathologic factors of invasive breast cancer. Medicine (Baltimore) 99(44):e23023CrossRefPubMed Ko KH, Jung HK, Park AY, Koh JE, Jang H, Kim Y (2020) Accuracy of tumor size measurement on shear wave elastography (SWE): correlation with histopathologic factors of invasive breast cancer. Medicine (Baltimore) 99(44):e23023CrossRefPubMed
Metadata
Title
Preoperative imaging accuracy in size determination of prostate cancer in men undergoing radical prostatectomy for clinically localised disease
Authors
Wael Ageeli
Nabi Soha
Xinyu Zhang
Magdalena Szewcyk-Bieda
Jennifer Wilson
Chunhui Li
Ghulam Nabi
Publication date
01-12-2023
Publisher
Springer Vienna
Published in
Insights into Imaging / Issue 1/2023
Electronic ISSN: 1869-4101
DOI
https://doi.org/10.1186/s13244-023-01450-5

Other articles of this Issue 1/2023

Insights into Imaging 1/2023 Go to the issue