Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 2/2015

01-12-2015 | Original Paper

Predicting the image noise level of prospective ECG-triggered coronary computed tomography angiography: quantitative measurement of thoracic component versus body mass index

Authors: Hyeongmin Kim, Chul Hwan Park, Kyung Hwa Han, Tae Hoon Kim

Published in: The International Journal of Cardiovascular Imaging | Special Issue 2/2015

Login to get access

Abstract

We evaluated the feasibility of using quantitatively measured thoracic components, as compared to body mass index (BMI), for predicting the image noise of coronary computed tomography angiography (CCTA). One hundred subjects (M:F = 64:36; mean age, 55 ± 8.8 years) who underwent prospective electrocardiography-gated CCTA and low-dose chest computed tomography (CT) were analyzed retrospectively. The image noise of the CCTA was determined by the standard deviation of the attenuation value in a region of interest on the aortic root level. On the low-dose chest CT, the areas of the thoracic components were measured at the aortic root level. An auto-segmentation technique with the following threshold levels was used: quantitatively measured area of total thorax [QMAtotal: −910 to 1000 Hounsfield units (HU)], lung (QMAlung: −910 to −200 HU), fat (QMAfat: −200 to 0 HU), muscle (QMAmuscle: 0–300 HU), soft tissue (fat + muscle, QMAsoft tissue: −200 to 300 HU), bone (QMAbone: 300–1000 HU) and solid tissue (fat + muscle + bone, QMAsolid tissue: −200 to 1000 HU). The relationship between image noise and variable biometric parameters including QMA was analyzed, and the linear correlation coefficients were used as indicators of the strength of association. Among the variable biometric parameters, including BMI, QMAsolid tissue showed the highest correlation coefficient with image noise in all subjects (r = 0.804), males (r = 0.716), females (r = 0.889), the overweight (r = 0.556), and the non-overweight subgroups (r = 0.783). QMAsolid tissue can be used as a potential surrogate predictor of the image noise level in low tube voltage CCTA.
Literature
1.
go back to reference Yoshimura N, Sabir A, Kubo T, Lin PJ, Clouse ME, Hatabu H (2006) Correlation between image noise and body weight in coronary CTA with 16-row MDCT. Acad Radiol 13(3):324–328CrossRefPubMed Yoshimura N, Sabir A, Kubo T, Lin PJ, Clouse ME, Hatabu H (2006) Correlation between image noise and body weight in coronary CTA with 16-row MDCT. Acad Radiol 13(3):324–328CrossRefPubMed
2.
go back to reference Herzog BA, Husmann L, Valenta I, Tay FM, Burkhard N, Gaemperli O, Wyss CA, Landmesser U, Kaufmann PA (2009) Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 25(6):625–630CrossRefPubMed Herzog BA, Husmann L, Valenta I, Tay FM, Burkhard N, Gaemperli O, Wyss CA, Landmesser U, Kaufmann PA (2009) Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering. Int J Cardiovasc Imaging 25(6):625–630CrossRefPubMed
3.
go back to reference Leschka S, Stolzmann P, Schmid FT, Scheffel H, Stinn B, Marincek B, Alkadhi H, Wildermuth S (2008) Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 18(9):1809–1817CrossRefPubMed Leschka S, Stolzmann P, Schmid FT, Scheffel H, Stinn B, Marincek B, Alkadhi H, Wildermuth S (2008) Low kilovoltage cardiac dual-source CT: attenuation, noise, and radiation dose. Eur Radiol 18(9):1809–1817CrossRefPubMed
4.
go back to reference Neefjes LA, Rossi A, Genders TS, Nieman K, Papadopoulou SL, Dharampal AS, Schultz CJ, Weustink AC, Dijkshoorn ML, Ten Kate GJ, Dedic A, van Straten M, Cademartiri F, Hunink MG, Krestin GP, de Feyter PJ, Mollet NR (2013) Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols. Eur Radiol 23(3):614–622CrossRefPubMed Neefjes LA, Rossi A, Genders TS, Nieman K, Papadopoulou SL, Dharampal AS, Schultz CJ, Weustink AC, Dijkshoorn ML, Ten Kate GJ, Dedic A, van Straten M, Cademartiri F, Hunink MG, Krestin GP, de Feyter PJ, Mollet NR (2013) Diagnostic accuracy of 128-slice dual-source CT coronary angiography: a randomized comparison of different acquisition protocols. Eur Radiol 23(3):614–622CrossRefPubMed
5.
go back to reference Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA, Nieman K, van Werkhoven JM, Pundziute G, Weustink AC, de Vos AM, Pugliese F, Rensing B, Jukema JW, Bax JJ, Prokop M, Doevendans PA, Hunink MG, Krestin GP, de Feyter PJ (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144CrossRefPubMed Meijboom WB, Meijs MF, Schuijf JD, Cramer MJ, Mollet NR, van Mieghem CA, Nieman K, van Werkhoven JM, Pundziute G, Weustink AC, de Vos AM, Pugliese F, Rensing B, Jukema JW, Bax JJ, Prokop M, Doevendans PA, Hunink MG, Krestin GP, de Feyter PJ (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144CrossRefPubMed
6.
go back to reference Paul NS, Kashani H, Odedra D, Ursani A, Ray C, Rogalla P (2011) The influence of chest wall tissue composition in determining image noise during cardiac CT. AJR Am J Roentgenol 197(6):1328–1334CrossRefPubMed Paul NS, Kashani H, Odedra D, Ursani A, Ray C, Rogalla P (2011) The influence of chest wall tissue composition in determining image noise during cardiac CT. AJR Am J Roentgenol 197(6):1328–1334CrossRefPubMed
7.
go back to reference Menke J (2005) Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236(2):565–571CrossRefPubMed Menke J (2005) Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236(2):565–571CrossRefPubMed
8.
go back to reference Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176(2):289–296CrossRefPubMed Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176(2):289–296CrossRefPubMed
9.
go back to reference Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217(2):430–435CrossRefPubMed Huda W, Scalzetti EM, Levin G (2000) Technique factors and image quality as functions of patient weight at abdominal CT. Radiology 217(2):430–435CrossRefPubMed
10.
go back to reference Renker M, Ramachandra A, Schoepf UJ, Raupach R, Apfaltrer P, Rowe GW, Vogt S, Flohr TG, Kerl JM, Bauer RW, Fink C, Henzler T (2011) Iterative image reconstruction techniques: applications for cardiac CT. J Cardiovasc Comput Tomogr 5(4):225–230CrossRefPubMed Renker M, Ramachandra A, Schoepf UJ, Raupach R, Apfaltrer P, Rowe GW, Vogt S, Flohr TG, Kerl JM, Bauer RW, Fink C, Henzler T (2011) Iterative image reconstruction techniques: applications for cardiac CT. J Cardiovasc Comput Tomogr 5(4):225–230CrossRefPubMed
11.
go back to reference Haaga JR (2001) Radiation dose management: weighing risk versus benefit. AJR Am J Roentgenol 177(2):289–291CrossRefPubMed Haaga JR (2001) Radiation dose management: weighing risk versus benefit. AJR Am J Roentgenol 177(2):289–291CrossRefPubMed
12.
go back to reference Wildberger JE, Mahnken AH, Schmitz-Rode T, Flohr T, Stargardt A, Haage P, Schaller S, Gunther RW (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36(10):604–611CrossRefPubMed Wildberger JE, Mahnken AH, Schmitz-Rode T, Flohr T, Stargardt A, Haage P, Schaller S, Gunther RW (2001) Individually adapted examination protocols for reduction of radiation exposure in chest CT. Invest Radiol 36(10):604–611CrossRefPubMed
13.
go back to reference Ghoshhajra BB, Engel LC, Major GP, Verdini D, Sidhu M, Karolyi M, Abbara S, Hoffmann U, Kalra M, Brady TJ (2011) Direct chest area measurement: a potential anthropometric replacement for BMI to inform cardiac CT dose parameters? J Cardiovasc Comput Tomogr 5(4):240–246CrossRefPubMed Ghoshhajra BB, Engel LC, Major GP, Verdini D, Sidhu M, Karolyi M, Abbara S, Hoffmann U, Kalra M, Brady TJ (2011) Direct chest area measurement: a potential anthropometric replacement for BMI to inform cardiac CT dose parameters? J Cardiovasc Comput Tomogr 5(4):240–246CrossRefPubMed
14.
go back to reference Mahnken AH, Wildberger JE, Simon J, Koos R, Flohr TG, Schaller S, Gunther RW (2003) Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol. AJR Am J Roentgenol 181(2):533–538CrossRefPubMed Mahnken AH, Wildberger JE, Simon J, Koos R, Flohr TG, Schaller S, Gunther RW (2003) Detection of coronary calcifications: feasibility of dose reduction with a body weight-adapted examination protocol. AJR Am J Roentgenol 181(2):533–538CrossRefPubMed
15.
go back to reference Kalra MK, Maher MM, Prasad SR, Hayat MS, Blake MA, Varghese J, Halpern EF, Saini S (2003) Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT. Korean J Radiol 4(4):234–238PubMedCentralCrossRefPubMed Kalra MK, Maher MM, Prasad SR, Hayat MS, Blake MA, Varghese J, Halpern EF, Saini S (2003) Correlation of patient weight and cross-sectional dimensions with subjective image quality at standard dose abdominal CT. Korean J Radiol 4(4):234–238PubMedCentralCrossRefPubMed
16.
go back to reference Schuhbaeck A, Schaefer M, Marwan M, Gauss S, Muschiol G, Lell M, Pflederer T, Ropers D, Rixe J, Hamm C, Daniel WG, Achenbach S (2013) Patient-specific predictors of image noise in coronary CT angiography. J Cardiovasc Comput Tomogr 7(1):39–45CrossRefPubMed Schuhbaeck A, Schaefer M, Marwan M, Gauss S, Muschiol G, Lell M, Pflederer T, Ropers D, Rixe J, Hamm C, Daniel WG, Achenbach S (2013) Patient-specific predictors of image noise in coronary CT angiography. J Cardiovasc Comput Tomogr 7(1):39–45CrossRefPubMed
17.
go back to reference Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, Weigold WG (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3(3):190–204CrossRefPubMed Abbara S, Arbab-Zadeh A, Callister TQ, Desai MY, Mamuya W, Thomson L, Weigold WG (2009) SCCT guidelines for performance of coronary computed tomographic angiography: a report of the Society of Cardiovascular Computed Tomography Guidelines Committee. J Cardiovasc Comput Tomogr 3(3):190–204CrossRefPubMed
18.
go back to reference Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Schomig A, Achenbach S (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507CrossRefPubMed Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, McCollough C, Martinoff S, Kastrati A, Schomig A, Achenbach S (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507CrossRefPubMed
19.
go back to reference Fuchs TA, Stehli J, Bull S, Dougoud S, Clerc OF, Herzog BA, Buechel RR, Gaemperli O, Kaufmann PA (2014) Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination. Eur Heart J 35(17):1131–1136PubMedCentralCrossRefPubMed Fuchs TA, Stehli J, Bull S, Dougoud S, Clerc OF, Herzog BA, Buechel RR, Gaemperli O, Kaufmann PA (2014) Coronary computed tomography angiography with model-based iterative reconstruction using a radiation exposure similar to chest X-ray examination. Eur Heart J 35(17):1131–1136PubMedCentralCrossRefPubMed
20.
go back to reference Oda S, Utsunomiya D, Funama Y, Katahira K, Honda K, Tokuyasu S, Vembar M, Yuki H, Noda K, Oshima S, Yamashita Y (2014) A knowledge-based iterative model reconstruction algorithm: can super-low-dose cardiac CT be applicable in clinical settings? Acad Radiol 21(1):104–110CrossRefPubMed Oda S, Utsunomiya D, Funama Y, Katahira K, Honda K, Tokuyasu S, Vembar M, Yuki H, Noda K, Oshima S, Yamashita Y (2014) A knowledge-based iterative model reconstruction algorithm: can super-low-dose cardiac CT be applicable in clinical settings? Acad Radiol 21(1):104–110CrossRefPubMed
21.
go back to reference Expert Consultation WHO (2004) Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies. Lancet 363(9403):157–163CrossRef Expert Consultation WHO (2004) Appropriate body-mass index for Asian populations and its implications for policy and intervention strategies. Lancet 363(9403):157–163CrossRef
22.
go back to reference Sevrukov A, Pratap A, Doss C, Jelnin V, Hoff JA, Kondos GT (2002) Electron beam tomography imaging of coronary calcium: the effect of body mass index on radiologic noise. J Comput Assist Tomogr 26(4):592–597CrossRefPubMed Sevrukov A, Pratap A, Doss C, Jelnin V, Hoff JA, Kondos GT (2002) Electron beam tomography imaging of coronary calcium: the effect of body mass index on radiologic noise. J Comput Assist Tomogr 26(4):592–597CrossRefPubMed
23.
go back to reference Vollmar SV, Kalender WA (2009) Reduction of dose to the female breast as a result of spectral optimisation for high-contrast thoracic CT imaging: a phantom study. Br J Radiol 82(983):920–929CrossRefPubMed Vollmar SV, Kalender WA (2009) Reduction of dose to the female breast as a result of spectral optimisation for high-contrast thoracic CT imaging: a phantom study. Br J Radiol 82(983):920–929CrossRefPubMed
Metadata
Title
Predicting the image noise level of prospective ECG-triggered coronary computed tomography angiography: quantitative measurement of thoracic component versus body mass index
Authors
Hyeongmin Kim
Chul Hwan Park
Kyung Hwa Han
Tae Hoon Kim
Publication date
01-12-2015
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue Special Issue 2/2015
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-015-0796-6

Other articles of this Special Issue 2/2015

The International Journal of Cardiovascular Imaging 2/2015 Go to the issue