01-03-2020 | Positron Emission Tomography

Time-related study on external exposure dose of 2-deoxy-2-[F-18]fluoro-d-glucose PET for workers’ safety

Authors: Yasuyuki Takahashi, Shota Hosokawa, Takakiyo Tsujiguchi, Satoru Monzen, Takao Kanzaki, Koji Shirakawa, Ayaka Nemoto, Hayato Ishimura, Noboru Oriuchi

Published in: Radiological Physics and Technology | Issue 1/2020

Login to get access

Abstract

Time-course study of individual dose equivalents of 2-deoxy-2-[F-18]fluoro-d-glucose positron emission tomography (18F-FDG PET) was conducted in different hospital workers, and the daily work duties were analyzed. For the measurements, a semiconductor dosimeter was used. The values at intervals of 1 min and 1 h, the monthly cumulative and daily cumulative doses, and trend graphs were acquired with dedicated software and displayed on the reader. The following radiation workers with duties involving maximum external exposure work were included: doctors making diagnoses (4.8 μSv/procedure), nurses removing injection needles (3.1 μSv/procedure), pharmacists performing quality control tests (2.9 μSv/procedure), nuclear medicine technologists assisting patient positioning (6.5 μSv/procedure), and cyclotron engineers performing daily checks (13.4 μSv/procedure). The results of analysis of daily work duties revealed the influencing factors of external exposure dose. To reduce the external exposure dose, investigators should shorten the patient’s contact time with the 18F-FDG source or patient tracer.
Literature
1.
go back to reference Melcher CL. Scintillation crystals for PET. J Nucl Med. 2000;41:1051–5.PubMed Melcher CL. Scintillation crystals for PET. J Nucl Med. 2000;41:1051–5.PubMed
2.
go back to reference Lodge MA, Badawi RD, Gilbert R, Dibos PE, Line BR. Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. J Nucl Med. 2006;47:23–31.PubMed Lodge MA, Badawi RD, Gilbert R, Dibos PE, Line BR. Comparison of 2-dimensional and 3-dimensional acquisition for 18F-FDG PET oncology studies performed on an LSO-based scanner. J Nucl Med. 2006;47:23–31.PubMed
3.
go back to reference Chiesa C, De Sanctis V, Crippa F, Schiavini M, Fraigola CE, Bogni A, et al. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med. 1997;24:1380–9.CrossRef Chiesa C, De Sanctis V, Crippa F, Schiavini M, Fraigola CE, Bogni A, et al. Radiation dose to technicians per nuclear medicine procedure: comparison between technetium-99m, gallium-67, and iodine-131 radiotracers and fluorine-18 fluorodeoxyglucose. Eur J Nucl Med. 1997;24:1380–9.CrossRef
4.
go back to reference Bayram T, Yilmaz AH, Demir M, Sonmez B. Radiation dose to technologists per nuclear medicine examination and estimation of annual dose. J Nucl Med Technol. 2011;39:55–9.CrossRef Bayram T, Yilmaz AH, Demir M, Sonmez B. Radiation dose to technologists per nuclear medicine examination and estimation of annual dose. J Nucl Med Technol. 2011;39:55–9.CrossRef
5.
go back to reference Harding LK, Harding NJ, Warren H, Mills A, Thomson WH. The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room. Nucl Med comm. 1990;11:17–22.CrossRef Harding LK, Harding NJ, Warren H, Mills A, Thomson WH. The radiation dose to accompanying nurses, relatives and other patients in a nuclear medicine department waiting room. Nucl Med comm. 1990;11:17–22.CrossRef
6.
go back to reference Benatar NA, Cronin BF, O’Doherty MJ. Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas. Eur J Nucl Med Mol Imaging. 2000;27:583–9.CrossRef Benatar NA, Cronin BF, O’Doherty MJ. Radiation dose rates from patients undergoing PET: implications for technologists and waiting areas. Eur J Nucl Med Mol Imaging. 2000;27:583–9.CrossRef
7.
go back to reference Covens P, Berus D, Vanhavere F, Caveliers V. The introduction of automated dispensing and injection during PET procedures: a step in optimisation of extremity doses and whole-body doses of nuclear medicine staff. Radiat Prot Dosimetry. 2010;140:250–8.CrossRef Covens P, Berus D, Vanhavere F, Caveliers V. The introduction of automated dispensing and injection during PET procedures: a step in optimisation of extremity doses and whole-body doses of nuclear medicine staff. Radiat Prot Dosimetry. 2010;140:250–8.CrossRef
8.
go back to reference Yasuda H, Fujitaka K. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation. Radiat Prot Dosimetry. 2002;100:545–8.CrossRef Yasuda H, Fujitaka K. Efficiency of a radiophotoluminescence glass dosemeter for low-earth-orbit space radiation. Radiat Prot Dosimetry. 2002;100:545–8.CrossRef
9.
go back to reference Suzuki A, Suzuki T, Takahashi M, Nakata T, Murayama T, Tsunoda M. Characteristics of OSL dosimeter for individual monitoring for external radiation. JAEA-Technology. 2014;49:1–8 (In Japanese). Suzuki A, Suzuki T, Takahashi M, Nakata T, Murayama T, Tsunoda M. Characteristics of OSL dosimeter for individual monitoring for external radiation. JAEA-Technology. 2014;49:1–8 (In Japanese).
10.
go back to reference Cemusova Z, Ekendahl D, Judas L. Testing of the D-Shuttle personal dosemeter. Radiat Meas. 2017;106:214–7.CrossRef Cemusova Z, Ekendahl D, Judas L. Testing of the D-Shuttle personal dosemeter. Radiat Meas. 2017;106:214–7.CrossRef
11.
go back to reference Yamaguchi Y, Saito T. Secular and angular response changes of semiconductor-type electronic pocket dosimeter. Jpn J Radiat Magag. 2004;3:21–6 (In Japanese). Yamaguchi Y, Saito T. Secular and angular response changes of semiconductor-type electronic pocket dosimeter. Jpn J Radiat Magag. 2004;3:21–6 (In Japanese).
12.
go back to reference Nakamura F, Kanno T, Okada H, Yoshikawa E, Andou I, Futatsubashi M, et al. Measurement of radiation exposure to a PET institution driver from patients injected with FDG. Jpn J Radiol Technol. 2006;62:1105–10 (In Japanese).CrossRef Nakamura F, Kanno T, Okada H, Yoshikawa E, Andou I, Futatsubashi M, et al. Measurement of radiation exposure to a PET institution driver from patients injected with FDG. Jpn J Radiol Technol. 2006;62:1105–10 (In Japanese).CrossRef
14.
go back to reference Murayama K. Outline of D-Shuttle and its application. Radioisotopes. 2018;67:452–60.CrossRef Murayama K. Outline of D-Shuttle and its application. Radioisotopes. 2018;67:452–60.CrossRef
15.
go back to reference Deji S, Nishizawa K. Effects of high frequency electromagnetic fields emitted from digital cellular telephones on electronic pocket dosimeters. Jpn J Radiat Magag. 2003;2:33–7 (In Japanese). Deji S, Nishizawa K. Effects of high frequency electromagnetic fields emitted from digital cellular telephones on electronic pocket dosimeters. Jpn J Radiat Magag. 2003;2:33–7 (In Japanese).
16.
go back to reference ICRP Publication 103. The 2007 recommendations of the International Commission on radiological protection. Ann ICRP. 2007;37:2–4. ICRP Publication 103. The 2007 recommendations of the International Commission on radiological protection. Ann ICRP. 2007;37:2–4.
17.
go back to reference Levinger R, Budinger TF, Watson EE. 1991. MIRD primer for absorbed dose calculations: Revised. New York: The Society of Nuclear Medicine, pdf. Accessed 17 Oct 2019. Levinger R, Budinger TF, Watson EE. 1991. MIRD primer for absorbed dose calculations: Revised. New York: The Society of Nuclear Medicine, pdf. Accessed 17 Oct 2019.
18.
go back to reference Choju K. Gamma-ray shielding lead glass for PET facilities “Pro-GR”. New Glass. 2006;21:65–9 (In Japanese). Choju K. Gamma-ray shielding lead glass for PET facilities “Pro-GR”. New Glass. 2006;21:65–9 (In Japanese).
Metadata
Title
Time-related study on external exposure dose of 2-deoxy-2-[F-18]fluoro-d-glucose PET for workers’ safety
Authors
Yasuyuki Takahashi
Shota Hosokawa
Takakiyo Tsujiguchi
Satoru Monzen
Takao Kanzaki
Koji Shirakawa
Ayaka Nemoto
Hayato Ishimura
Noboru Oriuchi
Publication date
01-03-2020
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 1/2020
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-019-00548-0

Other articles of this Issue 1/2020

Radiological Physics and Technology 1/2020 Go to the issue