Skip to main content
Top
Published in: Radiological Physics and Technology 1/2020

01-03-2020 | Computed Tomography

Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods

Authors: Ayaka Chiba, Kohei Harada, Yoshiya Ohashi, Kanako Numasawa, Tatsuya Imai, Shun Hayasaka

Published in: Radiological Physics and Technology | Issue 1/2020

Login to get access

Abstract

Computed tomography arterial portography (CTAP) is widely used with a fixed scan timing and contrast medium quantity; however, these parameters are not necessarily optimal. In this study, CTAP scan timing was analyzed by different bolus tracking methods to monitor the inflow of the contrast medium in real-time. A total of 249 patients who underwent CTAP were assessed. In 30 patients, the CTAP scanning began 33 s after contrast medium injection started (fixed method). In 74 patients, the regions of interest (ROIs) were established at two places in the inferior vena cava above the hepatic vein (inferior vena cava-ROI method). In 145 patients, the ROI was established at two places in the liver parenchyma (liver parenchyma-ROI method). Scan timing was considered appropriate when the difference in the CT value between the hepatic and portal veins approached 0; this was observed significantly more with the liver parenchyma-ROI method than with the other methods. CTAP scan timing with the liver parenchyma-ROI method was better than that with the fixed and inferior vena cava-ROI methods.
Literature
1.
go back to reference Taouli B, Koh DM. Diffusion-weighted MR imaging of the liver. Radiology. 2010;254:47–66.CrossRef Taouli B, Koh DM. Diffusion-weighted MR imaging of the liver. Radiology. 2010;254:47–66.CrossRef
2.
go back to reference Ichikawa T, Sano K, Morisaka H. Diagnosis of pathologically early HCC with EOB-MRI: experiences and current consensus. Liver Cancer. 2014;3:97–107.CrossRef Ichikawa T, Sano K, Morisaka H. Diagnosis of pathologically early HCC with EOB-MRI: experiences and current consensus. Liver Cancer. 2014;3:97–107.CrossRef
3.
go back to reference Testa ML, Chojniak R, Sene LS, Damascena AS, Guimaraes MD, Szklaruk J, Marchiori E. Is DWI/ADC a useful tool in the characterization of focal hepatic lesions suspected of malignancy? PLoS ONE. 2014;9:e101944.CrossRef Testa ML, Chojniak R, Sene LS, Damascena AS, Guimaraes MD, Szklaruk J, Marchiori E. Is DWI/ADC a useful tool in the characterization of focal hepatic lesions suspected of malignancy? PLoS ONE. 2014;9:e101944.CrossRef
4.
go back to reference Murakami T, Oi H, Hori M, Kim T, Takahashi S, Tomoda K, Narumi Y, Nakamura H. Helical CT during arterial portography and hepatic arteriography for detecting hypervascular hepatocellular carcinoma. Am J Roentgenol. 1997;169:131–5.CrossRef Murakami T, Oi H, Hori M, Kim T, Takahashi S, Tomoda K, Narumi Y, Nakamura H. Helical CT during arterial portography and hepatic arteriography for detecting hypervascular hepatocellular carcinoma. Am J Roentgenol. 1997;169:131–5.CrossRef
5.
go back to reference Onaya H, Itai Y, Satake M, Luo T, Saida Y, Haruno M, Hasebe T, Moriyama N. Highly enhanced hepatic masses seen on CT during arterial portography: early hepatocellular carcinoma and adenomatous hyperplasia. Jpn J Clin Oncol. 2000;30:440–5.CrossRef Onaya H, Itai Y, Satake M, Luo T, Saida Y, Haruno M, Hasebe T, Moriyama N. Highly enhanced hepatic masses seen on CT during arterial portography: early hepatocellular carcinoma and adenomatous hyperplasia. Jpn J Clin Oncol. 2000;30:440–5.CrossRef
6.
go back to reference Li L, Liu LZ, Xie ZM, Mo YX, Zheng L, Ruan CM, Chen L, Wu PH. Multi-phasic CT arterial portography and CT hepatic arteriography improving the accuracy of liver cancer detection. World J Gastroenterol. 2004;10:3118–211.CrossRef Li L, Liu LZ, Xie ZM, Mo YX, Zheng L, Ruan CM, Chen L, Wu PH. Multi-phasic CT arterial portography and CT hepatic arteriography improving the accuracy of liver cancer detection. World J Gastroenterol. 2004;10:3118–211.CrossRef
7.
go back to reference Ohnishi H, Sakaguchi K, Nouso K, Kobayashi Y, Nakamura S, Tanaka H, Miyake Y, Shoji B, Iwadou S, Shiratori Y. Outcome of small liver nodules detected by computed tomographic angiography in patients with hepatocellular carcinoma. Hepatol Int. 2010;4:562–8.CrossRef Ohnishi H, Sakaguchi K, Nouso K, Kobayashi Y, Nakamura S, Tanaka H, Miyake Y, Shoji B, Iwadou S, Shiratori Y. Outcome of small liver nodules detected by computed tomographic angiography in patients with hepatocellular carcinoma. Hepatol Int. 2010;4:562–8.CrossRef
8.
go back to reference Ohki T, Tateishi R, Akahane M, Mikami S, Sato M, Uchino K, Arano T, Enooku K, Kondo Y, Yamashiki N, Goto T, Shiina S, Yoshida H, Matsuyama Y, Omata M, Ohtomo K, Koike K. CT with hepatic arterioportography as a pretreatment examination for hepatocellular carcinoma patients: a randomized controlled trial. Am J Gastroenterol. 2013;108:1305–13.CrossRef Ohki T, Tateishi R, Akahane M, Mikami S, Sato M, Uchino K, Arano T, Enooku K, Kondo Y, Yamashiki N, Goto T, Shiina S, Yoshida H, Matsuyama Y, Omata M, Ohtomo K, Koike K. CT with hepatic arterioportography as a pretreatment examination for hepatocellular carcinoma patients: a randomized controlled trial. Am J Gastroenterol. 2013;108:1305–13.CrossRef
9.
go back to reference Shah S, Shukla A, Paunipagar B. Radiological features of hepatocellular carcinoma. J Clin Exp Hepatol. 2014;4:S63–6.CrossRef Shah S, Shukla A, Paunipagar B. Radiological features of hepatocellular carcinoma. J Clin Exp Hepatol. 2014;4:S63–6.CrossRef
10.
go back to reference Minami Y, Kudo M. Ultrasound fusion imaging of hepatocellular carcinoma: a review of current evidence. Dig Dis. 2014;32:690–5.CrossRef Minami Y, Kudo M. Ultrasound fusion imaging of hepatocellular carcinoma: a review of current evidence. Dig Dis. 2014;32:690–5.CrossRef
11.
go back to reference Iimuro Y. ICG clearance test and 99mTc-GSA SPECT/CT fusion images. Visc Med. 2017;33:449–54.CrossRef Iimuro Y. ICG clearance test and 99mTc-GSA SPECT/CT fusion images. Visc Med. 2017;33:449–54.CrossRef
12.
go back to reference Kondo H, Kanematsu M, Hoshi H, Murakami T, Kim T, Hori M, Matsuo M, Nakamura H. Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Am J Roentgenol. 2000;174:947–54.CrossRef Kondo H, Kanematsu M, Hoshi H, Murakami T, Kim T, Hori M, Matsuo M, Nakamura H. Preoperative detection of malignant hepatic tumors: comparison of combined methods of MR imaging with combined methods of CT. Am J Roentgenol. 2000;174:947–54.CrossRef
13.
go back to reference Bagia JS, Chai A, Chou R, Chu C, Rouse J, Sinclair E, Vonthethoff L, Teixeira-Pinto A. Prospective diagnostic test accuracy comparison of computed tomography during arterial portography and primovist magnetic resonance imaging in the pre-operative assessment of colorectal cancer liver metastases. HPB (Oxford). 2015;17:927–35.CrossRef Bagia JS, Chai A, Chou R, Chu C, Rouse J, Sinclair E, Vonthethoff L, Teixeira-Pinto A. Prospective diagnostic test accuracy comparison of computed tomography during arterial portography and primovist magnetic resonance imaging in the pre-operative assessment of colorectal cancer liver metastases. HPB (Oxford). 2015;17:927–35.CrossRef
14.
go back to reference Conti CB, Cavalcoli F, Fraquelli M, Conte D, Massironi S. Ultrasound elastographic techniques in focal liver lesions. World J Gastroenterol. 2016;22:2647–56.CrossRef Conti CB, Cavalcoli F, Fraquelli M, Conte D, Massironi S. Ultrasound elastographic techniques in focal liver lesions. World J Gastroenterol. 2016;22:2647–56.CrossRef
15.
go back to reference Kwee SA, Sato MM, Kuang Y, Franke A, Custer L, Miyazaki K, Wong LL. [(18)F]Fluorocholine PET/CT imaging of liver cancer: radiopathologic correlation with tissue phospholipid profiling. Mol Imaging Biol. 2017;19:446–55.CrossRef Kwee SA, Sato MM, Kuang Y, Franke A, Custer L, Miyazaki K, Wong LL. [(18)F]Fluorocholine PET/CT imaging of liver cancer: radiopathologic correlation with tissue phospholipid profiling. Mol Imaging Biol. 2017;19:446–55.CrossRef
16.
go back to reference Fu CJ, Wong YC, Tsang YM, Wang LJ, Chen HW, Ku YK, Wu CH, Chen HW, Kang SC. Computed tomography arterial portography for assessment of portal vein injury after blunt hepatic trauma. Diagn Interv Radiol. 2015;21:361–7.CrossRef Fu CJ, Wong YC, Tsang YM, Wang LJ, Chen HW, Ku YK, Wu CH, Chen HW, Kang SC. Computed tomography arterial portography for assessment of portal vein injury after blunt hepatic trauma. Diagn Interv Radiol. 2015;21:361–7.CrossRef
17.
go back to reference Sandstede JJ, Tschammler A, Beer M, Vogelsang C, Wittenberg G, Hahn D. Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol. 2001;11:1396–400.CrossRef Sandstede JJ, Tschammler A, Beer M, Vogelsang C, Wittenberg G, Hahn D. Optimization of automatic bolus tracking for timing of the arterial phase of helical liver CT. Eur Radiol. 2001;11:1396–400.CrossRef
18.
go back to reference Ozaki K, Matsui O, Kobayashi S, Sanada J, Koda W, Minami T, Kawai K, Gabata T. Selective atrophy of the middle hepatic venous drainage area in hepatitis C-related cirrhotic liver: morphometric study by using multidetector CT. Radiology. 2010;257:705–14.CrossRef Ozaki K, Matsui O, Kobayashi S, Sanada J, Koda W, Minami T, Kawai K, Gabata T. Selective atrophy of the middle hepatic venous drainage area in hepatitis C-related cirrhotic liver: morphometric study by using multidetector CT. Radiology. 2010;257:705–14.CrossRef
19.
go back to reference Yoshikawa S, Okada M, Kondo H, Sou H, Murakami T, Kanematsu M, Ichikawa T, Hayakawa A, Shiosakai K, Awai K, Yoshimitsu K, Yamashita Y. Multicenter trial for optimization of bolus tracking settings and contrast material injection protocol in arterial dominant phase of dynamic computed tomography for diagnosis of hepatocellular carcinoma. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014;70:805–13.CrossRef Yoshikawa S, Okada M, Kondo H, Sou H, Murakami T, Kanematsu M, Ichikawa T, Hayakawa A, Shiosakai K, Awai K, Yoshimitsu K, Yamashita Y. Multicenter trial for optimization of bolus tracking settings and contrast material injection protocol in arterial dominant phase of dynamic computed tomography for diagnosis of hepatocellular carcinoma. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2014;70:805–13.CrossRef
20.
go back to reference Couch GG, Johnston KW, Ojha M. An in vitro comparison of the hemodynamics of two inferior vena cava filters. J Vasc Surg. 2000;31:539–49.CrossRef Couch GG, Johnston KW, Ojha M. An in vitro comparison of the hemodynamics of two inferior vena cava filters. J Vasc Surg. 2000;31:539–49.CrossRef
21.
go back to reference Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV. Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology. 1995;195:353–7.CrossRef Heiken JP, Brink JA, McClennan BL, Sagel SS, Crowe TM, Gaines MV. Dynamic incremental CT: effect of volume and concentration of contrast material and patient weight on hepatic enhancement. Radiology. 1995;195:353–7.CrossRef
22.
go back to reference Erturk SM, Ichikawa T, Sou H, Tsukamoto T, Motosugi U, Araki T. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight. Clin Radiol. 2008;63:263–71.CrossRef Erturk SM, Ichikawa T, Sou H, Tsukamoto T, Motosugi U, Araki T. Effect of duration of contrast material injection on peak enhancement times and values of the aorta, main portal vein, and liver at dynamic MDCT with the dose of contrast medium tailored to patient weight. Clin Radiol. 2008;63:263–71.CrossRef
23.
go back to reference Fleischmann D, Kamaya A. Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin N Am. 2009;47:13–26.CrossRef Fleischmann D, Kamaya A. Optimal vascular and parenchymal contrast enhancement: the current state of the art. Radiol Clin N Am. 2009;47:13–26.CrossRef
Metadata
Title
Evaluation of computed tomography arterial portography scan timing using different bolus tracking methods
Authors
Ayaka Chiba
Kohei Harada
Yoshiya Ohashi
Kanako Numasawa
Tatsuya Imai
Shun Hayasaka
Publication date
01-03-2020
Publisher
Springer Singapore
Published in
Radiological Physics and Technology / Issue 1/2020
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-020-00556-5

Other articles of this Issue 1/2020

Radiological Physics and Technology 1/2020 Go to the issue