Published in: World Journal of Surgical Oncology 1/2015

Open Access 01-12-2015 | Technical innovations

Optimization of breast cancer excision by intraoperative ultrasound and marking needle - technique description and feasibility

Authors: Nebojsa S Ivanovic, Darko D Zdravkovic, Zlatko Skuric, Jelena Kostic, Natasa Colakovic, Miodrag Stojiljkovic, Svetlana Opric, Magdalena Stefanovic Radovic, Ivan Soldatovic, Biljana Sredic, Miroslav Granic

Published in: World Journal of Surgical Oncology | Issue 1/2015

Login to get access

Abstract

Background

We present a surgical technique and the preliminary results of breast cancer excision after insertion of a specially constructed marking needle into the tumor, controlled by intraoperative ultrasound.
Resection margins were projected in six directions by ultrasound measurements, determined in relation to the needle, and resection was done in accordance with those measurements. The main objective was to obtain resection margins similar (equal) to those projected by intraoperative ultrasound (10 mm).

Methods

Detailed description of the technique is given. Thirty-two female patients undergoing breast-conserving surgery, up to 30 mm in diameter, for palpable and non-palpable invasive breast cancer, were operated on using this technique. Its feasibility was tested by analyzing the success (rate) of needle placement in the tumor, the measurements executed, and the performance of the excision.

Results

All stages of the technique were successfully performed to completion on all 32 patients. The procedure of needle placement and ultrasound measurement of distances took 11 min on average (between 6 and 20 min). The average distance of the tumor margin from the resection margin was 12.9 mm (2 to 30 mm, 95% confidence interval [11.9, 14.06]). There was one patient with a positive resection margin (3%).

Conclusions

The technique of excising palpable and non-palpable breast cancer by intraoperative ultrasound and an especially constructed marking needle is feasible and comfortable to perform. Preliminary results imply that resection volume can be rationalized, with the same or better oncological safety.
Literature
1.
go back to reference Schwartz GF, Goldberg BB, Rifkin MD, D’Orazio SE. Ultrasonography: an alternative to x-ray-guided needle localization of nonpalpable breast masses. Surgery. 1988;104:870–3.PubMed Schwartz GF, Goldberg BB, Rifkin MD, D’Orazio SE. Ultrasonography: an alternative to x-ray-guided needle localization of nonpalpable breast masses. Surgery. 1988;104:870–3.PubMed
2.
go back to reference Rahusen FD, van Amerongen AH T, van Diest PJ, Borgstein PJ, Bleichrodt RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancers: a feasibility study looking at the accuracy of obtained margins. J Surg Oncol. 1999;72:72–6.CrossRefPubMed Rahusen FD, van Amerongen AH T, van Diest PJ, Borgstein PJ, Bleichrodt RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancers: a feasibility study looking at the accuracy of obtained margins. J Surg Oncol. 1999;72:72–6.CrossRefPubMed
3.
go back to reference Snider HC, Morrison DG. Intraoperative ultrasound localization of nonpalpable breast lesions. Ann Surg Oncol. 1999;6:308–14.CrossRefPubMed Snider HC, Morrison DG. Intraoperative ultrasound localization of nonpalpable breast lesions. Ann Surg Oncol. 1999;6:308–14.CrossRefPubMed
4.
go back to reference Harlow SP, Krag DN, Ames SE, Weaver DL. Intraoperative ultrasound localization to guide surgical excision of nonpalpable breast carcinoma. J Am Coll Surg. 1999;189:241–6.CrossRefPubMed Harlow SP, Krag DN, Ames SE, Weaver DL. Intraoperative ultrasound localization to guide surgical excision of nonpalpable breast carcinoma. J Am Coll Surg. 1999;189:241–6.CrossRefPubMed
5.
go back to reference Smith LF, Rubio IT, Henry-Tillman R, Korourian S, Klimberg VS. Intraoperative ultrasound-guided breast biopsy. Am J Surg. 2000;180:419–23.CrossRefPubMed Smith LF, Rubio IT, Henry-Tillman R, Korourian S, Klimberg VS. Intraoperative ultrasound-guided breast biopsy. Am J Surg. 2000;180:419–23.CrossRefPubMed
6.
go back to reference Rahusen FD, Bremers AJA, Fabry HFJ, van Amerongen AH, Boom RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial. Ann Surg Oncol. 2000;9:994–8.CrossRef Rahusen FD, Bremers AJA, Fabry HFJ, van Amerongen AH, Boom RP, Meijer S. Ultrasound-guided lumpectomy of nonpalpable breast cancer versus wire-guided resection: a randomized clinical trial. Ann Surg Oncol. 2000;9:994–8.CrossRef
7.
go back to reference Kaufman CS, Jacobson L, Bachman B, Kaufman LB. Intraoperative ultrasonography guidance is accurate and efficient according to results in 100 breast cancer patients. Am J Surg. 2003;186:378–82.CrossRefPubMed Kaufman CS, Jacobson L, Bachman B, Kaufman LB. Intraoperative ultrasonography guidance is accurate and efficient according to results in 100 breast cancer patients. Am J Surg. 2003;186:378–82.CrossRefPubMed
8.
go back to reference Bennett IC, Greenslade J, Chiam H. Intraoperative ultrasound-guided excision of nonpalpable breast lesions. World J Surg. 2005;29:369–74.CrossRefPubMed Bennett IC, Greenslade J, Chiam H. Intraoperative ultrasound-guided excision of nonpalpable breast lesions. World J Surg. 2005;29:369–74.CrossRefPubMed
9.
go back to reference Haid A, Knauer M, Dunzinger S, Jasarevic Z, Köberle-Wührer R, Schuster A, et al. Intra-operative sonography: a valuable aid during breastconserving surgery for occult breast cancer. Ann Surg Oncol. 2007;14:3090–101.CrossRefPubMed Haid A, Knauer M, Dunzinger S, Jasarevic Z, Köberle-Wührer R, Schuster A, et al. Intra-operative sonography: a valuable aid during breastconserving surgery for occult breast cancer. Ann Surg Oncol. 2007;14:3090–101.CrossRefPubMed
10.
go back to reference Potter S, Govindarajulu S, Cawthorn SJ, Sahu AK. Accuracy of sonographic localisation and specimen ultrasound performed by surgeons in impalpable screen-detected breast lesions. Breast. 2007;16:425–8.CrossRefPubMed Potter S, Govindarajulu S, Cawthorn SJ, Sahu AK. Accuracy of sonographic localisation and specimen ultrasound performed by surgeons in impalpable screen-detected breast lesions. Breast. 2007;16:425–8.CrossRefPubMed
11.
go back to reference Ngô C, Pollet AG, Laperrelle J, Ackerman G, Gomme S, Thibault F, et al. Intraoperative ultrasound localization of nonpalpable breast cancers. Ann Surg Oncol. 2007;14:2485–9.CrossRefPubMed Ngô C, Pollet AG, Laperrelle J, Ackerman G, Gomme S, Thibault F, et al. Intraoperative ultrasound localization of nonpalpable breast cancers. Ann Surg Oncol. 2007;14:2485–9.CrossRefPubMed
12.
go back to reference Fortunato L, Penteriani R, Farina M, Vitelli CE, Piro FR. Intraoperative ultrasound is an effective and preferable technique to localize non-palpable breast tumors. Eur J Surg Oncol. 2008;34:1289–92.CrossRefPubMed Fortunato L, Penteriani R, Farina M, Vitelli CE, Piro FR. Intraoperative ultrasound is an effective and preferable technique to localize non-palpable breast tumors. Eur J Surg Oncol. 2008;34:1289–92.CrossRefPubMed
13.
go back to reference Moore MM, Whitney LA, Cerilli L, Imbrie JZ, Bunch M, Simpson VB, et al. Intraoperative ultrasound is associated with clear lumpectomy margins for palpable infiltrating ductal breast cancer. Ann Surg. 2001;233:761–8.CrossRefPubMedCentralPubMed Moore MM, Whitney LA, Cerilli L, Imbrie JZ, Bunch M, Simpson VB, et al. Intraoperative ultrasound is associated with clear lumpectomy margins for palpable infiltrating ductal breast cancer. Ann Surg. 2001;233:761–8.CrossRefPubMedCentralPubMed
14.
go back to reference Olsha O, Shemesh D, Carmon M, Sibirsky O, Abu Dalo R, Rivkin L, et al. Resection margins in ultrasound-guided breast-conserving surgery. Ann Surg Oncol. 2011;18:447–52.CrossRefPubMed Olsha O, Shemesh D, Carmon M, Sibirsky O, Abu Dalo R, Rivkin L, et al. Resection margins in ultrasound-guided breast-conserving surgery. Ann Surg Oncol. 2011;18:447–52.CrossRefPubMed
15.
go back to reference Davis KM, Hsu CH, Bouton ME, Wilhelmson KL, Komenaka IK. Intraoperative ultrasound can decrease the re-excision lumpectomy rate in patients with palpable breast cancers. Am Surg. 2011;77:720–5.PubMed Davis KM, Hsu CH, Bouton ME, Wilhelmson KL, Komenaka IK. Intraoperative ultrasound can decrease the re-excision lumpectomy rate in patients with palpable breast cancers. Am Surg. 2011;77:720–5.PubMed
16.
go back to reference Fisher CS, Mushawah FA, Cyr AE, Gao F, Margenthaler JA. Ultrasound-guided lumpectomy for palpable breast cancers. Ann Surg Oncol. 2011;18:3198–203.CrossRefPubMed Fisher CS, Mushawah FA, Cyr AE, Gao F, Margenthaler JA. Ultrasound-guided lumpectomy for palpable breast cancers. Ann Surg Oncol. 2011;18:3198–203.CrossRefPubMed
17.
go back to reference Krekel NM, Lopes Cardozo AM, Muller S, Bergers E, Meijer S, van den Tol MP. Optimising surgical accuracy in palpable breast cancer with intra-operative breast ultrasound - feasibility and surgeons’ learning curve. Eur J Surg Oncol. 2011;37:1044–50.CrossRefPubMed Krekel NM, Lopes Cardozo AM, Muller S, Bergers E, Meijer S, van den Tol MP. Optimising surgical accuracy in palpable breast cancer with intra-operative breast ultrasound - feasibility and surgeons’ learning curve. Eur J Surg Oncol. 2011;37:1044–50.CrossRefPubMed
18.
go back to reference Eichler C, Hubbel A, Zarghooni V, Thomas A, Gluz O, Stoff-Khalili M, et al. Intraoperative ultrasound: improved resection rates in breast-conserving surgery. Anticancer Res. 2012;32:1051–6.PubMed Eichler C, Hubbel A, Zarghooni V, Thomas A, Gluz O, Stoff-Khalili M, et al. Intraoperative ultrasound: improved resection rates in breast-conserving surgery. Anticancer Res. 2012;32:1051–6.PubMed
19.
go back to reference Krekel NM, Haloua MH, Lopes Cardozo AM, de Wit RH, Bosch AM, de Widt-Levert LM, et al. Intraoperative ultrasound guidance for palpable breast cancer excision (COBALT trial): a multicentre, randomised controlled trial. Lancet Oncol. 2013;14:48–54.CrossRefPubMed Krekel NM, Haloua MH, Lopes Cardozo AM, de Wit RH, Bosch AM, de Widt-Levert LM, et al. Intraoperative ultrasound guidance for palpable breast cancer excision (COBALT trial): a multicentre, randomised controlled trial. Lancet Oncol. 2013;14:48–54.CrossRefPubMed
20.
go back to reference Yu CC, Chiang KC, Kuo WL, Shen SC, Lo YF, Chen SC. Low re-excision rate for positive margins in patients treated with ultrasound-guided breast-conserving surgery. Breast. 2013;22:698–702.CrossRefPubMed Yu CC, Chiang KC, Kuo WL, Shen SC, Lo YF, Chen SC. Low re-excision rate for positive margins in patients treated with ultrasound-guided breast-conserving surgery. Breast. 2013;22:698–702.CrossRefPubMed
21.
go back to reference Gittleman MA. Single-step ultrasound localization of breast lesions and lumpectomy procedure. Am J Surg. 2003;186:386–90.CrossRefPubMed Gittleman MA. Single-step ultrasound localization of breast lesions and lumpectomy procedure. Am J Surg. 2003;186:386–90.CrossRefPubMed
22.
go back to reference DeJean P, Brackstone M, Fenster A. An intraoperative 3D ultrasound system for tumor margin determination in breast cancer surgery. Med Phys. 2010;37:564–70.CrossRefPubMed DeJean P, Brackstone M, Fenster A. An intraoperative 3D ultrasound system for tumor margin determination in breast cancer surgery. Med Phys. 2010;37:564–70.CrossRefPubMed
23.
go back to reference James TA, Harlow S, Sheehey-Jones J, Hart M, Gaspari C, Stanley M, et al. Intraoperative ultrasound versus mammographic needle localization for ductal carcinoma in situ. Ann Surg Oncol. 2009;16:1164–9.CrossRefPubMed James TA, Harlow S, Sheehey-Jones J, Hart M, Gaspari C, Stanley M, et al. Intraoperative ultrasound versus mammographic needle localization for ductal carcinoma in situ. Ann Surg Oncol. 2009;16:1164–9.CrossRefPubMed
24.
go back to reference Bouton ME, Wilhelmson KL, Komenaka IK. Intraoperative ultrasound can facilitate the wire guided breast procedure for mammographic abnormalities. Am Surg. 2011;77:640–6.PubMed Bouton ME, Wilhelmson KL, Komenaka IK. Intraoperative ultrasound can facilitate the wire guided breast procedure for mammographic abnormalities. Am Surg. 2011;77:640–6.PubMed
25.
go back to reference Barentsz MW, van Dalen T, Gobardhan PD, Bongers V, Perre CI, Pijnappel RM, et al. Intraoperative ultrasound guidance for excision of nonpalpable invasive breast cancer: a hospital-based series and an overview of the literature. Breast Cancer Res Treat. 2012;135:209–19. 11.CrossRefPubMed Barentsz MW, van Dalen T, Gobardhan PD, Bongers V, Perre CI, Pijnappel RM, et al. Intraoperative ultrasound guidance for excision of nonpalpable invasive breast cancer: a hospital-based series and an overview of the literature. Breast Cancer Res Treat. 2012;135:209–19. 11.CrossRefPubMed
26.
go back to reference Ramos M, Díaz JC, Ramos T, Ruano R, Aparicio M, Sancho M, et al. Ultrasound-guided excision combined with intraoperative assessment of gross macroscopic margins decreases the rate of reoperations for non-palpable invasive breast cancer. Breast. 2013;22:520–4.CrossRefPubMed Ramos M, Díaz JC, Ramos T, Ruano R, Aparicio M, Sancho M, et al. Ultrasound-guided excision combined with intraoperative assessment of gross macroscopic margins decreases the rate of reoperations for non-palpable invasive breast cancer. Breast. 2013;22:520–4.CrossRefPubMed
Metadata
Title
Optimization of breast cancer excision by intraoperative ultrasound and marking needle - technique description and feasibility
Authors
Nebojsa S Ivanovic
Darko D Zdravkovic
Zlatko Skuric
Jelena Kostic
Natasa Colakovic
Miodrag Stojiljkovic
Svetlana Opric
Magdalena Stefanovic Radovic
Ivan Soldatovic
Biljana Sredic
Miroslav Granic
Publication date
01-12-2015
Publisher
BioMed Central
Published in
World Journal of Surgical Oncology / Issue 1/2015
Electronic ISSN: 1477-7819
DOI
https://doi.org/10.1186/s12957-015-0568-8

Other articles of this Issue 1/2015

World Journal of Surgical Oncology 1/2015 Go to the issue