Skip to main content
Top
Published in: Fluids and Barriers of the CNS 1/2023

Open Access 01-12-2023 | Research

Non-invasive flow mapping of parasagittal meningeal lymphatics using 2D interslice flow saturation MRI

Authors: Jun-Hee Kim, Roh-Eul Yoo, Seung Hong Choi, Sung-Hong Park

Published in: Fluids and Barriers of the CNS | Issue 1/2023

Login to get access

Abstract

The clearance pathways of brain waste products in humans are still under debate in part due to the lack of noninvasive imaging techniques for meningeal lymphatic vessels (mLVs). In this study, we propose a new noninvasive mLVs imaging technique based on an inter-slice blood perfusion MRI called alternate ascending/descending directional navigation (ALADDIN). ALADDIN with inversion recovery (IR) at single inversion time of 2300 ms (single-TI IR-ALADDIN) clearly demonstrated parasagittal mLVs around the human superior sagittal sinus (SSS) with better detectability and specificity than the previously suggested noninvasive imaging techniques. While in many studies it has been difficult to detect mLVs and confirm their signal source noninvasively, the detection of mLVs in this study was confirmed by their posterior to anterior flow direction and their velocities and morphological features, which were consistent with those from the literature. In addition, IR-ALADDIN was compared with contrast-enhanced black blood imaging to confirm the detection of mLVs and its similarity. For the quantification of flow velocity of mLVs, IR-ALADDIN was performed at three inversion times of 2000, 2300, and 2600 ms (three-TI IR-ALADDIN) for both a flow phantom and humans. For this preliminary result, the flow velocity of the dorsal mLVs in humans ranged between 2.2 and 2.7 mm/s. Overall, (i) the single-TI IR-ALADDIN can be used as a novel non-invasive method to visualize mLVs in the whole brain with scan time of ~ 17 min and (ii) the multi-TI IR-ALADDIN can be used as a way to quantify the flow velocity of mLVs with a scan time of ~ 10 min (or shorter) in a limited coverage. Accordingly, the suggested approach can be applied to noninvasively studying meningeal lymphatic flows in general and also understanding the clearance pathways of waste production through mLVs in humans, which warrants further investigation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Louveau A, et al. Understanding the functions and relationships of the glymphatic system and meningeal lymphatics. J Clin Invest. 2017;127(9):3210–9.PubMedPubMedCentralCrossRef Louveau A, et al. Understanding the functions and relationships of the glymphatic system and meningeal lymphatics. J Clin Invest. 2017;127(9):3210–9.PubMedPubMedCentralCrossRef
3.
go back to reference Proulx ST. Cerebrospinal fluid outflow: a review of the historical and contemporary evidence for arachnoid villi, perineural routes, and dural lymphatics. Cell Mol Life Sci. 2021;78(6):2429–57.PubMedPubMedCentralCrossRef Proulx ST. Cerebrospinal fluid outflow: a review of the historical and contemporary evidence for arachnoid villi, perineural routes, and dural lymphatics. Cell Mol Life Sci. 2021;78(6):2429–57.PubMedPubMedCentralCrossRef
4.
go back to reference Brady M, et al. Cerebrospinal fluid drainage kinetics across the cribriform plate are reduced with aging. Fluids Barriers CNS. 2020;17:1–16.CrossRef Brady M, et al. Cerebrospinal fluid drainage kinetics across the cribriform plate are reduced with aging. Fluids Barriers CNS. 2020;17:1–16.CrossRef
6.
go back to reference Wichmann TO, Damkier HH, Pedersen M. A brief overview of the cerebrospinal fluid system and its implications for brain and spinal cord diseases. Front Hum Neurosci. 2022;15:850.CrossRef Wichmann TO, Damkier HH, Pedersen M. A brief overview of the cerebrospinal fluid system and its implications for brain and spinal cord diseases. Front Hum Neurosci. 2022;15:850.CrossRef
9.
go back to reference Ahn JH, et al. Meningeal lymphatic vessels at the skull base drain cerebrospinal fluid. Nature. 2019;572(7767):62–6.PubMedCrossRef Ahn JH, et al. Meningeal lymphatic vessels at the skull base drain cerebrospinal fluid. Nature. 2019;572(7767):62–6.PubMedCrossRef
12.
go back to reference das Neves SP, Delivanoglou N, Da Mesquita S. CNS-Draining meningeal lymphatic vasculature: roles, conundrums and future challenges. Front Pharmacol. 2021;12:655052.PubMedPubMedCentralCrossRef das Neves SP, Delivanoglou N, Da Mesquita S. CNS-Draining meningeal lymphatic vasculature: roles, conundrums and future challenges. Front Pharmacol. 2021;12:655052.PubMedPubMedCentralCrossRef
13.
go back to reference Tian Y, et al. The underlying role of the glymphatic system and meningeal lymphatic vessels in cerebral small vessel disease. Biomolecules. 2022;12(6):748.PubMedPubMedCentralCrossRef Tian Y, et al. The underlying role of the glymphatic system and meningeal lymphatic vessels in cerebral small vessel disease. Biomolecules. 2022;12(6):748.PubMedPubMedCentralCrossRef
15.
go back to reference Goodman JR, et al. Characterization of dural sinus-associated lymphatic vasculature in human Alzheimer’s dementia subjects. Brain Behav Immun. 2018;73:34–40.PubMedPubMedCentralCrossRef Goodman JR, et al. Characterization of dural sinus-associated lymphatic vasculature in human Alzheimer’s dementia subjects. Brain Behav Immun. 2018;73:34–40.PubMedPubMedCentralCrossRef
17.
go back to reference Park M, et al. Aging is positively associated with peri-sinus lymphatic space volume: assessment using 3T black-blood MRI. J Clin Med. 2020;9(10):3353.PubMedPubMedCentralCrossRef Park M, et al. Aging is positively associated with peri-sinus lymphatic space volume: assessment using 3T black-blood MRI. J Clin Med. 2020;9(10):3353.PubMedPubMedCentralCrossRef
20.
21.
22.
go back to reference Kuo PH, et al. Meningeal lymphatic vessel flow runs countercurrent to venous flow in the superior sagittal sinus of the human brain. Tomography. 2018;4(3):99–104.PubMedPubMedCentralCrossRef Kuo PH, et al. Meningeal lymphatic vessel flow runs countercurrent to venous flow in the superior sagittal sinus of the human brain. Tomography. 2018;4(3):99–104.PubMedPubMedCentralCrossRef
23.
go back to reference Park SH, Duong TQ. Brain MR perfusion-weighted imaging with alternate ascending/descending directional navigation. Magn Reson Med. 2011;65(6):1578–91.PubMedCrossRef Park SH, Duong TQ. Brain MR perfusion-weighted imaging with alternate ascending/descending directional navigation. Magn Reson Med. 2011;65(6):1578–91.PubMedCrossRef
24.
go back to reference Park SH, et al. Suppression of effects of gradient imperfections on imaging with alternate ascending/descending directional navigation. Magn Reson Med. 2012;68(5):1600–6.PubMedCrossRef Park SH, et al. Suppression of effects of gradient imperfections on imaging with alternate ascending/descending directional navigation. Magn Reson Med. 2012;68(5):1600–6.PubMedCrossRef
26.
go back to reference Benoit-Cattin H, et al. The SIMRI project: a versatile and interactive MRI simulator. J Magn Reson. 2005;173(1):97–115.PubMedCrossRef Benoit-Cattin H, et al. The SIMRI project: a versatile and interactive MRI simulator. J Magn Reson. 2005;173(1):97–115.PubMedCrossRef
27.
go back to reference Lu H, et al. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004;52(3):679–82.PubMedCrossRef Lu H, et al. Determining the longitudinal relaxation time (T1) of blood at 3.0 Tesla. Magn Reson Med. 2004;52(3):679–82.PubMedCrossRef
28.
go back to reference Lu H, et al. Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation. Magn Reson Med. 2012;67(1):42–9.PubMedCrossRef Lu H, et al. Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation. Magn Reson Med. 2012;67(1):42–9.PubMedCrossRef
29.
go back to reference Jordan JE, Dieter MNJPPhD, Enzmann R. Velocity and flow quantitation in the superior sagittal sinus with ungated and cine (gated) phase-contrast MR Imaging. J Magn Reson Imaging. 1994;4(1):25–8.PubMedCrossRef Jordan JE, Dieter MNJPPhD, Enzmann R. Velocity and flow quantitation in the superior sagittal sinus with ungated and cine (gated) phase-contrast MR Imaging. J Magn Reson Imaging. 1994;4(1):25–8.PubMedCrossRef
30.
go back to reference Rane S, et al. Clinical feasibility of noninvasive visualization of lymphatic flow using principles of spin labeling MRI: implications for lymphedema assessment. Radiology. 2013;269(3):893.PubMedCrossRef Rane S, et al. Clinical feasibility of noninvasive visualization of lymphatic flow using principles of spin labeling MRI: implications for lymphedema assessment. Radiology. 2013;269(3):893.PubMedCrossRef
31.
go back to reference Park JK, et al. Association of lymphatic flow velocity with surgical outcomes in patients undergoing lymphovenous anastomosis for breast cancer-related lymphedema. Breast Cancer. 2022;29(5):835–43.PubMedCrossRef Park JK, et al. Association of lymphatic flow velocity with surgical outcomes in patients undergoing lymphovenous anastomosis for breast cancer-related lymphedema. Breast Cancer. 2022;29(5):835–43.PubMedCrossRef
32.
go back to reference Fischer M, et al. Flow velocity of single lymphatic capillaries in human skin. Am J Physiol Heart Circ Physiol. 1996;270(1):H358–63.CrossRef Fischer M, et al. Flow velocity of single lymphatic capillaries in human skin. Am J Physiol Heart Circ Physiol. 1996;270(1):H358–63.CrossRef
33.
go back to reference Dixon JB, et al. Lymph flow, shear stress, and lymphocyte velocity in rat mesenteric prenodal lymphatics. Microcirculation. 2006;13(7):597–610.PubMedCrossRef Dixon JB, et al. Lymph flow, shear stress, and lymphocyte velocity in rat mesenteric prenodal lymphatics. Microcirculation. 2006;13(7):597–610.PubMedCrossRef
34.
go back to reference Lu H, et al. Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging. 2005;22(1):13–22.PubMedCrossRef Lu H, et al. Routine clinical brain MRI sequences for use at 3.0 Tesla. J Magn Reson Imaging. 2005;22(1):13–22.PubMedCrossRef
36.
go back to reference Spijkerman JM, et al. T 2 mapping of cerebrospinal fluid: 3 T versus 7 T. MAGMA. 2018;31(3):415–24.PubMedCrossRef Spijkerman JM, et al. T 2 mapping of cerebrospinal fluid: 3 T versus 7 T. MAGMA. 2018;31(3):415–24.PubMedCrossRef
37.
go back to reference Yamada S, et al. Visualization of cerebrospinal fluid movement with spin labeling at MR imaging: preliminary results in normal and pathophysiologic conditions. Radiology. 2008;249(2):644–52.PubMedCrossRef Yamada S, et al. Visualization of cerebrospinal fluid movement with spin labeling at MR imaging: preliminary results in normal and pathophysiologic conditions. Radiology. 2008;249(2):644–52.PubMedCrossRef
38.
go back to reference Klarica M, Radoš M, Orešković D. The movement of cerebrospinal fluid and its relationship with substances behavior in cerebrospinal and interstitial fluid. Neuroscience. 2019;414:28–48.PubMedCrossRef Klarica M, Radoš M, Orešković D. The movement of cerebrospinal fluid and its relationship with substances behavior in cerebrospinal and interstitial fluid. Neuroscience. 2019;414:28–48.PubMedCrossRef
39.
go back to reference Matsumae M, et al. Velocity and pressure gradients of cerebrospinal fluid assessed with magnetic resonance imaging. J Neurosurg. 2014;120(1):218–27.PubMedCrossRef Matsumae M, et al. Velocity and pressure gradients of cerebrospinal fluid assessed with magnetic resonance imaging. J Neurosurg. 2014;120(1):218–27.PubMedCrossRef
40.
go back to reference Bollmann S, et al. Imaging of the pial arterial vasculature of the human brain in vivo using high-resolution 7T time-of-flight angiography. Elife. 2022;11:e71186.PubMedPubMedCentralCrossRef Bollmann S, et al. Imaging of the pial arterial vasculature of the human brain in vivo using high-resolution 7T time-of-flight angiography. Elife. 2022;11:e71186.PubMedPubMedCentralCrossRef
41.
go back to reference Yushkevich PA, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. NeuroImage. 2006;31(3):1116–28.PubMedCrossRef Yushkevich PA, et al. User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. NeuroImage. 2006;31(3):1116–28.PubMedCrossRef
42.
go back to reference Yaniv Z, et al. SimpleITK image-analysis notebooks: a collaborative environment for education and reproducible research. J Digit Imaging. 2018;31(3):290–303.PubMedCrossRef Yaniv Z, et al. SimpleITK image-analysis notebooks: a collaborative environment for education and reproducible research. J Digit Imaging. 2018;31(3):290–303.PubMedCrossRef
43.
go back to reference Karasan E, Zhang Z, Lustig M. “Reverse Perfusion” Imaging of the Cerebral Venous System with Displacement Spectrum Imaging (DiSpect). in Joint Annual Meeting ISMRM-ESMRMB & ISMRT 31st Annual Meeting. 2022;30:0044. London, England, UK. Karasan E, Zhang Z, Lustig M. “Reverse Perfusion” Imaging of the Cerebral Venous System with Displacement Spectrum Imaging (DiSpect). in Joint Annual Meeting ISMRM-ESMRMB & ISMRT 31st Annual Meeting. 2022;30:0044. London, England, UK.
Metadata
Title
Non-invasive flow mapping of parasagittal meningeal lymphatics using 2D interslice flow saturation MRI
Authors
Jun-Hee Kim
Roh-Eul Yoo
Seung Hong Choi
Sung-Hong Park
Publication date
01-12-2023
Publisher
BioMed Central
Published in
Fluids and Barriers of the CNS / Issue 1/2023
Electronic ISSN: 2045-8118
DOI
https://doi.org/10.1186/s12987-023-00446-z

Other articles of this Issue 1/2023

Fluids and Barriers of the CNS 1/2023 Go to the issue