Skip to main content
Top
Published in: European Journal of Orthopaedic Surgery & Traumatology 8/2014

01-12-2014 | Original Article

Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings

Authors: T. Bouras, T. Repantis, P. Fennema, P. Korovessis

Published in: European Journal of Orthopaedic Surgery & Traumatology | Issue 8/2014

Login to get access

Abstract

A recent comparative study reported lower revision rate and higher survival in ceramic-on-ceramic (CoC) than in metal-on-metal (MoM) coupling in Zweymüller-Plus THA. We retrospectively studied 87 consecutive patients (94 hips), who primarily received Zweymüller-Plus THA (SL-Plus stem, ceramic 28-mm ball head, Bicon cup) with third-generation CoC bearing surfaces for osteoarthritis. Survival, revision and osteolysis rate were studied and compared to those observed in historical series from this institution with the same THA and MoM articulation. The mean ± SD follow-up was 7.4 ± 1.7 years (range 6–10 years). Four hips (4 %) in four patients were revised 1–6 years following primary implantation: one (1 %) for aseptic loosening of SL-Plus stem and Bicon 5 years after index surgery; one (1 %) for malpositioning of the Bicon and recurrent dislocations 1 year following implantation; and two (2 %) for septic loosening 1 and 6 years postoperatively. Intraoperatively on inspection, there were neither findings for impingement in the revised hips, nor fracture of the Bicon ceramic inlay and ball head. Expansile osteolysis was shown around SL-Plus stem and Bicon in the revised for aseptic loosening hip. With revision of any component for aseptic loosening as the endpoint, the survival was 99 % (95 % CI 91–100 %), while for revision for any reason, it was 95 % (95 % CI 87–98 %) at 10 years. Zweymüller-Plus THA with CoC bearings showed, at mid-term follow-up, high survival and low revision rate for aseptic loosening. These rates were better than the historical series of the same THA with MoM articulation performed by the same surgeon.

Level of evidence

Level IV.
Literature
1.
go back to reference Petsatodis GE et al (2010) Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Joint Surg Am 92:639–644PubMedCrossRef Petsatodis GE et al (2010) Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Joint Surg Am 92:639–644PubMedCrossRef
2.
go back to reference Korovessis P, Repantis T, Zafiropoulos A (2011) High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty. Arch Orthop Trauma Surg 131(5):603–611PubMedCrossRef Korovessis P, Repantis T, Zafiropoulos A (2011) High medium-term survivorship and durability of Zweymüller-Plus total hip arthroplasty. Arch Orthop Trauma Surg 131(5):603–611PubMedCrossRef
3.
go back to reference Korovessis P, Petsinis G, Repanti M, Repantis T (2006) Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up. J Bone Joint Surg Am 88:1183–1191PubMedCrossRef Korovessis P, Petsinis G, Repanti M, Repantis T (2006) Metallosis after contemporary metal-on-metal total hip arthroplasty. Five to nine-year follow-up. J Bone Joint Surg Am 88:1183–1191PubMedCrossRef
4.
go back to reference Milosev I, Trebse R, Kovac S, Cör A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:1173–1182PubMedCrossRef Milosev I, Trebse R, Kovac S, Cör A, Pisot V (2006) Survivorship and retrieval analysis of Sikomet metal-on-metal total hip replacements at a mean of seven years. J Bone Joint Surg Am 88:1173–1182PubMedCrossRef
5.
go back to reference Repantis T, Vitsas V, Korovessis P (2013) Poor mid-term survival of the low-carbide metal-on-metal Zweymüller-plus total hip arthroplasty system: a concise follow-up, at a minimum of ten years, of a previous report*. J Bone Joint Surg Am 95(6):e331–e334PubMedCrossRef Repantis T, Vitsas V, Korovessis P (2013) Poor mid-term survival of the low-carbide metal-on-metal Zweymüller-plus total hip arthroplasty system: a concise follow-up, at a minimum of ten years, of a previous report*. J Bone Joint Surg Am 95(6):e331–e334PubMedCrossRef
6.
go back to reference Milošev I, Kovač S, Trebše R, Levašič V, Pišot V (2012) Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings. J Bone Joint Surg Am 94:1756–1763PubMedCrossRef Milošev I, Kovač S, Trebše R, Levašič V, Pišot V (2012) Comparison of ten-year survivorship of hip prostheses with use of conventional polyethylene, metal-on-metal, or ceramic-on-ceramic bearings. J Bone Joint Surg Am 94:1756–1763PubMedCrossRef
7.
go back to reference Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M (2008) Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 23:39–43PubMedCrossRef Capello WN, D’Antonio JA, Feinberg JR, Manley MT, Naughton M (2008) Ceramic-on-ceramic total hip arthroplasty: update. J Arthroplasty 23:39–43PubMedCrossRef
8.
go back to reference Yeung E et al (2012) Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up. J Bone Joint Surg Am 94:138–144PubMedCrossRef Yeung E et al (2012) Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up. J Bone Joint Surg Am 94:138–144PubMedCrossRef
9.
go back to reference Lee Y-K et al (2010) Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report. J Bone Joint Surg Am 92:1715–1719PubMed Lee Y-K et al (2010) Alumina-on-alumina total hip arthroplasty: a concise follow-up, at a minimum of ten years, of a previous report. J Bone Joint Surg Am 92:1715–1719PubMed
10.
go back to reference Lusty PJ et al (2007) Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 89:2676–2683PubMedCrossRef Lusty PJ et al (2007) Third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty. J Bone Joint Surg Am 89:2676–2683PubMedCrossRef
11.
go back to reference Willmann G (2000) Ceramic femoral head retrieval data. Clinical Orthop Relat Res 379:22–8CrossRef Willmann G (2000) Ceramic femoral head retrieval data. Clinical Orthop Relat Res 379:22–8CrossRef
12.
go back to reference Pappa E, Kontodimopoulos N, Niakas D (2005) Validating and norming of the Greek SF-36 Health Survey. Qual life Res 14:1433–1438PubMedCrossRef Pappa E, Kontodimopoulos N, Niakas D (2005) Validating and norming of the Greek SF-36 Health Survey. Qual life Res 14:1433–1438PubMedCrossRef
13.
go back to reference Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432–439PubMed Zicat B, Engh CA, Gokcen E (1995) Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am 77:432–439PubMed
14.
go back to reference Gruen TA, McNeice GM, Amstutz HC et al (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed Gruen TA, McNeice GM, Amstutz HC et al (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res 141:17–27PubMed
15.
go back to reference DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed DeLee JG, Charnley J (1976) Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res 121:20–32PubMed
16.
go back to reference Engh CA, Massin P, Suthers KE et al (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–28PubMed Engh CA, Massin P, Suthers KE et al (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–28PubMed
17.
go back to reference Nizard RS et al (1992) Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop Relat Res 282:53–63PubMed Nizard RS et al (1992) Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis. Clin Orthop Relat Res 282:53–63PubMed
18.
19.
go back to reference Murphy SB, Ecker TM, Tannast M (2006) Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res 453:97–102PubMedCrossRef Murphy SB, Ecker TM, Tannast M (2006) Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res 453:97–102PubMedCrossRef
20.
go back to reference Sugano N et al (2012) Eleven- to 14-year follow-up results of cementless total hip arthroplasty using a third-generation alumina ceramic-on-ceramic bearing. J Arthroplasty 27:736–741PubMedCrossRef Sugano N et al (2012) Eleven- to 14-year follow-up results of cementless total hip arthroplasty using a third-generation alumina ceramic-on-ceramic bearing. J Arthroplasty 27:736–741PubMedCrossRef
21.
go back to reference Yoo JJ et al (2005) Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 87:530–535PubMedCrossRef Yoo JJ et al (2005) Alumina-on-alumina total hip arthroplasty. A five-year minimum follow-up study. J Bone Joint Surg Am 87:530–535PubMedCrossRef
22.
go back to reference Koo K-H et al (2008) Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am 90:329–336PubMedCrossRef Koo K-H et al (2008) Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am 90:329–336PubMedCrossRef
23.
go back to reference Habermann B, Ewald W, Rauschmann M, Zichner L, Kurth AA (2006) Fracture of ceramic heads in total hip replacement. Arch Orthop Trauma Surg 126:464–470PubMedCrossRef Habermann B, Ewald W, Rauschmann M, Zichner L, Kurth AA (2006) Fracture of ceramic heads in total hip replacement. Arch Orthop Trauma Surg 126:464–470PubMedCrossRef
24.
go back to reference Walter WL, Yeung E, Esposito C (2010) A review of squeaking hips. J Am Acad Orthop Surg 18:319–326PubMed Walter WL, Yeung E, Esposito C (2010) A review of squeaking hips. J Am Acad Orthop Surg 18:319–326PubMed
25.
go back to reference Taylor S, Manley MT, Sutton K (2007) The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 22:47–51PubMedCrossRef Taylor S, Manley MT, Sutton K (2007) The role of stripe wear in causing acoustic emissions from alumina ceramic-on-ceramic bearings. J Arthroplasty 22:47–51PubMedCrossRef
26.
go back to reference Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW (2008) High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 466:1438–1443PubMedCentralPubMedCrossRef Keurentjes JC, Kuipers RM, Wever DJ, Schreurs BW (2008) High incidence of squeaking in THAs with alumina ceramic-on-ceramic bearings. Clin Orthop Relat Res 466:1438–1443PubMedCentralPubMedCrossRef
27.
go back to reference D’Antonio J, Capello W, Manley M, Naughton M, Sutton K et al. (2005) Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 436:164–71PubMedCrossRef D’Antonio J, Capello W, Manley M, Naughton M, Sutton K et al. (2005) Alumina ceramic bearings for total hip arthroplasty: five-year results of a prospective randomized study. Clin Orthop Relat Res 436:164–71PubMedCrossRef
28.
go back to reference Mallory TH, Lombardi AV, Fada RA, Herrington SM, Eberle RW et al (1999) Dislocation after total hip arthroplasty using the anterolateral abductor split approach. Clin Orthop Relat Res 166–72 Mallory TH, Lombardi AV, Fada RA, Herrington SM, Eberle RW et al (1999) Dislocation after total hip arthroplasty using the anterolateral abductor split approach. Clin Orthop Relat Res 166–72
29.
go back to reference Colwell CW et al (2007) Ceramic-on-ceramic total hip arthroplasty early dislocation rate. Clin Orthop Relat Res 465:155–158PubMed Colwell CW et al (2007) Ceramic-on-ceramic total hip arthroplasty early dislocation rate. Clin Orthop Relat Res 465:155–158PubMed
30.
go back to reference Jazrawi LM et al (1999) Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study. J Arthroplasty 14:781–787PubMedCrossRef Jazrawi LM et al (1999) Wear rates of ceramic-on-ceramic bearing surfaces in total hip implants: a 12-year follow-up study. J Arthroplasty 14:781–787PubMedCrossRef
Metadata
Title
Low aseptic loosening and revision rate in Zweymüller-Plus total hip arthroplasty with ceramic-on-ceramic bearings
Authors
T. Bouras
T. Repantis
P. Fennema
P. Korovessis
Publication date
01-12-2014
Publisher
Springer Paris
Published in
European Journal of Orthopaedic Surgery & Traumatology / Issue 8/2014
Print ISSN: 1633-8065
Electronic ISSN: 1432-1068
DOI
https://doi.org/10.1007/s00590-013-1314-y

Other articles of this Issue 8/2014

European Journal of Orthopaedic Surgery & Traumatology 8/2014 Go to the issue