Comparison of feasibility, time consumption and costs of three virtual planning systems for surgical correction of midfacial deficiency

Authors: Katrin Willinger, Godoberto Guevara-Rojas, Julia Cede, Kurt Schicho, Tanja Stamm, Clemens Klug

Published in: Maxillofacial Plastic and Reconstructive Surgery | Issue 1/2021

Login to get access

Abstract

Background

Today virtual surgical planning (VSP) is a standard method in maxillofacial corrective surgery and is the key to reach satisfactory esthetic outcomes. The purpose of this study was to evaluate usability of three established virtual surgical planning software applications by comparing feasibility, time consumption, and costs in a standardized workflow for a modified intraoral quadrangular Le Fort II osteotomy (IQLFIIO).

Results

A cross-sectional study was performed based on retrospective and re-planned data of patients with midfacial deficiency treated by modified IQLFIIO, using three software applications: IPS Case Designer ®, Dolphin Imaging ®, and ProPlan CMF ®. Feasibility: All evaluated steps of the VSP procedure could be successfully performed in all three evaluated applications. In all software packages, it was possible to design the surgical splints with CAD/CAM technology. Working time: The mean value of time needed was IPS Case Designer ®, 36.5 min; Dolphin Imaging ®, 33.6 min; ProPlan CMF ®, 45.5 min. We found statistical significant difference between ProPlan CMF ® and Dolphin Imaging ® (p value, 0.02). Costs: Asset costs for acquiring the software, license fee, license possibilities, paying for support services, and service contracts were evaluated and are found in similar ranges.

Conclusion

All three tested software applications are usable for virtual planning of an IQLFIIO and splint production by CAD/CAM technology. Successful movement of bone segments and overlaying soft tissues proved feasibility. Time consumption and costs were found in similar ranges.
Literature
1.
go back to reference Behrbohm, H. & Tardy, M. E. Funktionell-ästhetische Chirurgie der Nase: Septorhinoplastik. (Georg Thieme Verlag, 2004).pp 3-4, 21-22 Behrbohm, H. & Tardy, M. E. Funktionell-ästhetische Chirurgie der Nase: Septorhinoplastik. (Georg Thieme Verlag, 2004).pp 3-4, 21-22
4.
go back to reference Schneider D et al (2018) Customized virtual surgical planning in bimaxillary orthognathic surgery: a prospective randomized trial. Clin Oral Investig 23:3115–3122CrossRef Schneider D et al (2018) Customized virtual surgical planning in bimaxillary orthognathic surgery: a prospective randomized trial. Clin Oral Investig 23:3115–3122CrossRef
9.
go back to reference Chiu A, Chen Y, Hayashi J, Sadr A (2020) Accuracy of CAD/CAM digital impressions with different intraoral scanner parameters. Sensors 20:1157CrossRef Chiu A, Chen Y, Hayashi J, Sadr A (2020) Accuracy of CAD/CAM digital impressions with different intraoral scanner parameters. Sensors 20:1157CrossRef
10.
go back to reference Adolphs N, Liu W, Keeve E, Hoffmeister B (2014) RapidSplint: virtual splint generation for orthognathic surgery – results of a pilot series. Comput. Aided Surg. 19:20–28CrossRef Adolphs N, Liu W, Keeve E, Hoffmeister B (2014) RapidSplint: virtual splint generation for orthognathic surgery – results of a pilot series. Comput. Aided Surg. 19:20–28CrossRef
12.
go back to reference Chen X et al (2016) Development of a computer-aided design software for dental splint in orthognathic surgery. Sci Rep 6:1–10CrossRef Chen X et al (2016) Development of a computer-aided design software for dental splint in orthognathic surgery. Sci Rep 6:1–10CrossRef
13.
go back to reference Hirschinger V, Hanke S, Hirschfelder U, Hofmann E (2015) Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography. J Orofac Orthop 76:152–163CrossRef Hirschinger V, Hanke S, Hirschfelder U, Hofmann E (2015) Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography. J Orofac Orthop 76:152–163CrossRef
Metadata
Title
Comparison of feasibility, time consumption and costs of three virtual planning systems for surgical correction of midfacial deficiency
Authors
Katrin Willinger
Godoberto Guevara-Rojas
Julia Cede
Kurt Schicho
Tanja Stamm
Clemens Klug
Publication date
01-12-2021
Publisher
Springer Singapore
Published in
Maxillofacial Plastic and Reconstructive Surgery / Issue 1/2021
Electronic ISSN: 2288-8586
DOI
https://doi.org/10.1186/s40902-020-00284-1

Other articles of this Issue 1/2021

Maxillofacial Plastic and Reconstructive Surgery 1/2021 Go to the issue