Skip to main content
Top
Published in: EJNMMI Research 1/2019

Open Access 01-12-2019 | Parkinson's Disease | Original research

Impact of the cerebrospinal fluid-mask algorithm on the diagnostic performance of 123I-Ioflupane SPECT: an investigation of parkinsonian syndromes

Authors: Yu Iwabuchi, Tadaki Nakahara, Masashi Kameyama, Yohji Matsusaka, Yasuhiro Minami, Daisuke Ito, Hajime Tabuchi, Yoshitake Yamada, Masahiro Jinzaki

Published in: EJNMMI Research | Issue 1/2019

Login to get access

Abstract

Background

A cerebrospinal fluid (CSF)-mask algorithm has been developed to reduce the adverse influence of CSF-low-counts on the diagnostic utility of the specific binding ratio (SBR) index calculated with Southampton method. We assessed the effect of the CSF-mask algorithm on the diagnostic performance of the SBR index for parkinsonian syndromes (PS), including Parkinson’s disease, and the influence of cerebral ventricle dilatation on the CSF-mask algorithm.

Methods

We enrolled 163 and 158 patients with and without PS, respectively. Both the conventional SBR (non-CSF-mask) and SBR corrected with the CSF-mask algorithm (CSF-mask) were calculated from 123I-Ioflupane single-photon emission computed tomography (SPECT) images of these patients. We compared the diagnostic performance of the corresponding indices and evaluated whether the effect of the CSF-mask algorithm varied according to the extent of ventricle dilatation, as assessed with the Evans index (EI). A receiver-operating characteristics (ROC) analysis was used for statistical analyses.

Results

ROC analyses demonstrated that the CSF-mask algorithm performed better than the non-CSF-mask (no correction, area under the curve [AUC] = 0.917 [95% confidence interval (CI) 0.887–0.947] vs. 0.895 [95% CI 0.861–0.929], p < 0.001; attenuation correction, AUC = 0.930 [95% CI 0.902–0.957] vs. 0.903 [95% CI 0.870–0.936], p < 0.001). When not corrected for attenuation, no significant difference in the AUC was observed in the low EI group between the non-CSF-mask and CSF-mask algorithms (0.927 [95% CI 0.877–0.978] vs. 0.942 [95% CI 0.898–0.986], p = 0.11); in the middle and high EI groups, the CSF-mask algorithm performed better than the non-CSF-mask algorithm (middle EI group, AUC = 0.894 [95% CI 0.825–0.963] vs. 0.872 [95% CI 0.798–0.947], p < 0.05; high EI group, AUC = 0.931 [95% CI 0.883–0.978] vs. 0.900 [95% CI 0.840–0.961], p < 0.01). When corrected for attenuation, significant differences in the AUC were observed in all three EI groups (low EI group, AUC = 0.961 [95% CI 0.924–0.998] vs. 0.942 [95% CI 0.895–0.988], p < 0.05; middle EI group, AUC = 0.905 [95% CI 0.843–0.968] vs. 0.872 [95% CI 0.800–0.944], p < 0.005; high EI group, AUC = 0.954 [95% CI 0.917–0.991] vs. 0.917 [95% CI 0.862–0.973], p < 0.005).

Conclusion

The CSF-mask algorithm improved the performance of the SBR index in informing the diagnosis of PS, especially in cases with ventricle dilatation.
Literature
3.
go back to reference Tondeur MC, Hambye AS, Dethy S, Ham HR. Interobserver reproducibility of the interpretation of I-123 FP-CIT single-photon emission computed tomography. Nucl Med Commun. 2010;31:717–25.PubMedCrossRef Tondeur MC, Hambye AS, Dethy S, Ham HR. Interobserver reproducibility of the interpretation of I-123 FP-CIT single-photon emission computed tomography. Nucl Med Commun. 2010;31:717–25.PubMedCrossRef
8.
go back to reference Mizumura S, Nishikawa K, Murata A, Yoshimura K, Ishii N, Kokubo T, et al. Improvement in the measurement error of the specific binding ratio in dopamine transporter SPECT imaging due to exclusion of the cerebrospinal fluid fraction using the threshold of voxel RI count. Ann Nucl Med. 2018;32:288–96. https://doi.org/10.1007/s12149-018-1249-9.PubMedCrossRef Mizumura S, Nishikawa K, Murata A, Yoshimura K, Ishii N, Kokubo T, et al. Improvement in the measurement error of the specific binding ratio in dopamine transporter SPECT imaging due to exclusion of the cerebrospinal fluid fraction using the threshold of voxel RI count. Ann Nucl Med. 2018;32:288–96. https://​doi.​org/​10.​1007/​s12149-018-1249-9.PubMedCrossRef
12.
go back to reference Gibb WR, Lees AJ. The relevance of the Lewy body to the pathogenesis of idiopathic Parkinson’s disease. J Neurol Neurosurg Psychiatry. 1988;51:745–52.PubMedPubMedCentralCrossRef Gibb WR, Lees AJ. The relevance of the Lewy body to the pathogenesis of idiopathic Parkinson’s disease. J Neurol Neurosurg Psychiatry. 1988;51:745–52.PubMedPubMedCentralCrossRef
17.
go back to reference DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837–45.CrossRef DeLong ER, DeLong DM, Clarke-Pearson DL. Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics. 1988;44:837–45.CrossRef
Metadata
Title
Impact of the cerebrospinal fluid-mask algorithm on the diagnostic performance of 123I-Ioflupane SPECT: an investigation of parkinsonian syndromes
Authors
Yu Iwabuchi
Tadaki Nakahara
Masashi Kameyama
Yohji Matsusaka
Yasuhiro Minami
Daisuke Ito
Hajime Tabuchi
Yoshitake Yamada
Masahiro Jinzaki
Publication date
01-12-2019
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2019
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-019-0558-x

Other articles of this Issue 1/2019

EJNMMI Research 1/2019 Go to the issue