Abstract

Background

xSPECT Bone® (xB) is a new reconstruction algorithm developed by Siemens® in bone hybrid imaging (SPECT/CT). A CT-based tissue segmentation is incorporated into SPECT reconstruction to provide SPECT images with bone anatomy appearance. The objectives of this study were to assess xB/CT reconstruction diagnostic reliability and accuracy in comparison with Flash 3D® (F3D)/CT in clinical routine. Two hundred thirteen consecutive patients referred to the Brest Nuclear Medicine Department for non-oncological bone diseases were evaluated retrospectively. Two hundred seven SPECT/CT were included. All SPECT/CT were independently interpreted by two nuclear medicine physicians (a junior and a senior expert) with xB/CT then with F3D/CT three months later. Inter-observer agreement (IOA) and diagnostic confidence were determined using McNemar test, and unweighted Kappa coefficient. The study objectives were then re-assessed for validation through > 18 months of clinical and paraclinical follow-up.

Results

No statistically significant differences between IOA xB and IOA F3D were found (p = 0.532). Agreement for xB after categorical classification of the diagnoses was high (κ xB = 0.89 [95% CI 0.84 –0.93]) but without statistically significant difference F3D (κ F3D = 0.90 [95% CI 0.86 – 0.94]). Thirty-one (14.9%) inter-reconstruction diagnostic discrepancies were observed of which 21 (10.1%) were classified as major. The follow-up confirmed the diagnosis of F3D in 10 cases, xB in 6 cases and was non-contributory in 5 cases.

Conclusions

xB reconstruction algorithm was found reliable, providing high interobserver agreement and similar diagnostic confidence to F3D reconstruction in clinical routine.
Literature
1.
go back to reference Vija H. Introduction to xSPECT* technology: evolving multi-modal SPECT to become context-based and quantitative. Siemens Med Solut USA. 2013. Vija H. Introduction to xSPECT* technology: evolving multi-modal SPECT to become context-based and quantitative. Siemens Med Solut USA. 2013.
2.
go back to reference Ghosh P. xSPECT: a clinical overview. Siemens Med Solut USA. Ghosh P. xSPECT: a clinical overview. Siemens Med Solut USA.
3.
go back to reference Savelli G, Maffioli L, Maccauro M, De Deckere E, Bombardieri E. Bone scintigraphy and the added value of SPECT (single photon emission tomography) in detecting skeletal lesions. Q J Nucl Med. 2001;45:27–37.PubMed Savelli G, Maffioli L, Maccauro M, De Deckere E, Bombardieri E. Bone scintigraphy and the added value of SPECT (single photon emission tomography) in detecting skeletal lesions. Q J Nucl Med. 2001;45:27–37.PubMed
4.
go back to reference Even-Sapir E, Metser U, Mishani E, Lievshitz G, Lerman H, Leibovitch I. The detection of bone metastases in patients with high-risk prostate cancer: 99mTc-MDP planar bone scintigraphy, single- and multi-field-of-view SPECT, 18F-fluoride PET, and 18F-fluoride PET/CT. J Nucl Med. 2006;47:287–97.PubMed Even-Sapir E, Metser U, Mishani E, Lievshitz G, Lerman H, Leibovitch I. The detection of bone metastases in patients with high-risk prostate cancer: 99mTc-MDP planar bone scintigraphy, single- and multi-field-of-view SPECT, 18F-fluoride PET, and 18F-fluoride PET/CT. J Nucl Med. 2006;47:287–97.PubMed
5.
go back to reference Bryant LR, Song WS, Banks KP, Bui-Mansfield LT, Bradley YC. Comparison of planar scintigraphy alone and with SPECT for the initial evaluation of femoral neck stress fracture. AJR Am J Roentgenol. 2008;191:1010–5.CrossRefPubMed Bryant LR, Song WS, Banks KP, Bui-Mansfield LT, Bradley YC. Comparison of planar scintigraphy alone and with SPECT for the initial evaluation of femoral neck stress fracture. AJR Am J Roentgenol. 2008;191:1010–5.CrossRefPubMed
6.
go back to reference Horger M, Eschmann SM, Pfannenberg C, Vonthein R, Besenfelder H, Claussen CD, et al. Evaluation of combined transmission and emission tomography for classification of skeletal lesions. AJR Am J Roentgenol. 2004;183:655–61.CrossRefPubMed Horger M, Eschmann SM, Pfannenberg C, Vonthein R, Besenfelder H, Claussen CD, et al. Evaluation of combined transmission and emission tomography for classification of skeletal lesions. AJR Am J Roentgenol. 2004;183:655–61.CrossRefPubMed
7.
go back to reference Utsunomiya D, Shiraishi S, Imuta M, Tomigushi S, Kawanaka K, Awai K, et al. Added value of SPECT/CT fusion in assessing suspected bone metastasis: comparison with scintigraphy alone and nonfused scintigraphy and CT. Radiology. 2006;238:264–71.CrossRefPubMed Utsunomiya D, Shiraishi S, Imuta M, Tomigushi S, Kawanaka K, Awai K, et al. Added value of SPECT/CT fusion in assessing suspected bone metastasis: comparison with scintigraphy alone and nonfused scintigraphy and CT. Radiology. 2006;238:264–71.CrossRefPubMed
8.
go back to reference Huellner MW, Burkert A, Strobel K, Perez Lago Mdel S, Werner L, Hug U, et al. Imaging non-specific wrist pain: interobserver agreement and diagnostic accuracy of SPECT/CT, MRI, CT, bone scan and plain radiographs. PLoS One. 2013;8:e85359.CrossRefPubMedPubMedCentral Huellner MW, Burkert A, Strobel K, Perez Lago Mdel S, Werner L, Hug U, et al. Imaging non-specific wrist pain: interobserver agreement and diagnostic accuracy of SPECT/CT, MRI, CT, bone scan and plain radiographs. PLoS One. 2013;8:e85359.CrossRefPubMedPubMedCentral
9.
go back to reference Even-Sapir E, Flusser G, Lerman H, Lievshitz G, Metser U. SPECT/multislice low-dose CT: a clinically relevant constituent in the imaging algorithm of nononcologic patients referred for bone scintigraphy. J Nucl Med. 2007;48:319–24.PubMed Even-Sapir E, Flusser G, Lerman H, Lievshitz G, Metser U. SPECT/multislice low-dose CT: a clinically relevant constituent in the imaging algorithm of nononcologic patients referred for bone scintigraphy. J Nucl Med. 2007;48:319–24.PubMed
10.
go back to reference Zhao Z, Li L, Li F, Zhao L. Single photon emission computed tomography/spiral computed tomography fusion imaging for the diagnosis of bone metastasis in patients with known cancer. Skelet Radiol. 2010;39:147–53.CrossRef Zhao Z, Li L, Li F, Zhao L. Single photon emission computed tomography/spiral computed tomography fusion imaging for the diagnosis of bone metastasis in patients with known cancer. Skelet Radiol. 2010;39:147–53.CrossRef
11.
go back to reference Romer W, Nomayr A, Uder M, Bautz W, Kuwert T. SPECT-guided CT for evaluating foci of increased bone metabolism classified as indeterminate on SPECT in cancer patients. J Nucl Med. 2006;47:1102–6.PubMed Romer W, Nomayr A, Uder M, Bautz W, Kuwert T. SPECT-guided CT for evaluating foci of increased bone metabolism classified as indeterminate on SPECT in cancer patients. J Nucl Med. 2006;47:1102–6.PubMed
12.
go back to reference Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43:1723–38.CrossRefPubMedPubMedCentral Van den Wyngaert T, Strobel K, Kampen WU, Kuwert T, van der Bruggen W, Mohan HK, et al. The EANM practice guidelines for bone scintigraphy. Eur J Nucl Med Mol Imaging. 2016;43:1723–38.CrossRefPubMedPubMedCentral
13.
go back to reference Vija AH, Ma J, Bartenstein P, Froelich J, Kuwert T, Macapinlac H, et al. ROC analysis for xSPECT bone. J Nucl Med. 2015;56(supplement 3):1279. Vija AH, Ma J, Bartenstein P, Froelich J, Kuwert T, Macapinlac H, et al. ROC analysis for xSPECT bone. J Nucl Med. 2015;56(supplement 3):1279.
14.
go back to reference Bonardel G, Mantzarides M, Brenot-Rossi I, Gibold C, Foulquie P, Zerdoud S, et al. Enquête nationale de satisfaction réalisée auprès des cliniciens prescripteurs concernant la forme des comptes rendus en médecine nucléaire. Med Nucl. 2008;32:482–7. Bonardel G, Mantzarides M, Brenot-Rossi I, Gibold C, Foulquie P, Zerdoud S, et al. Enquête nationale de satisfaction réalisée auprès des cliniciens prescripteurs concernant la forme des comptes rendus en médecine nucléaire. Med Nucl. 2008;32:482–7.
15.
go back to reference Girma A, Ramadan A, Benisvy D, Malek Z, Fontana X, Darcourt J, et al. Reproductibilité en scintigraphie osseuse planaire, TEMP et TEMP/TDM du pied douloureux: importance d’une sémiologie standardisée. Med Nucl. 2010;34:513–27. Girma A, Ramadan A, Benisvy D, Malek Z, Fontana X, Darcourt J, et al. Reproductibilité en scintigraphie osseuse planaire, TEMP et TEMP/TDM du pied douloureux: importance d’une sémiologie standardisée. Med Nucl. 2010;34:513–27.
16.
go back to reference Zhang Y, Shi H, Gu Y, Xiu Y, Li B, Zhu W, et al. Differential diagnostic value of single-photon emission computed tomography/spiral computed tomography with Tc-99m-methylene diphosphonate in patients with spinal lesions. Nucl Med Commun. 2011;32:1194–200.CrossRefPubMed Zhang Y, Shi H, Gu Y, Xiu Y, Li B, Zhu W, et al. Differential diagnostic value of single-photon emission computed tomography/spiral computed tomography with Tc-99m-methylene diphosphonate in patients with spinal lesions. Nucl Med Commun. 2011;32:1194–200.CrossRefPubMed
17.
go back to reference Pagenstert GI, Barg A, Leumann AG, Rasch H, Müller-Brand J, Hintermann B, et al. SPECT-CT imaging in degenerative joint disease of the foot and ankle. J Bone Joint Surg Br. 2009;91:1191–6.CrossRefPubMed Pagenstert GI, Barg A, Leumann AG, Rasch H, Müller-Brand J, Hintermann B, et al. SPECT-CT imaging in degenerative joint disease of the foot and ankle. J Bone Joint Surg Br. 2009;91:1191–6.CrossRefPubMed
18.
go back to reference Helyar V, Mohan HK, Barwick T, Livieratos L, Gnanasegaran G, Clarke SE, et al. The added value of multislice SPECT/CT in patients with equivocal bony metastasis from carcinoma of the prostate. Eur J Nucl Med Mol Imaging. 2010;37:706–13.CrossRefPubMed Helyar V, Mohan HK, Barwick T, Livieratos L, Gnanasegaran G, Clarke SE, et al. The added value of multislice SPECT/CT in patients with equivocal bony metastasis from carcinoma of the prostate. Eur J Nucl Med Mol Imaging. 2010;37:706–13.CrossRefPubMed
Metadata
Title
A new SPECT/CT reconstruction algorithm: reliability and accuracy in clinical routine for non-oncologic bone diseases
Authors
Olivier Delcroix
Philippe Robin
Maelenn Gouillou
Alexandra Le Duc-Pennec
Zarrin Alavi
Pierre-Yves Le Roux
Ronan Abgral
Pierre-Yves Salaun
David Bourhis
Solène Querellou
Publication date
01-12-2018
Publisher
Springer Berlin Heidelberg
Published in
EJNMMI Research / Issue 1/2018
Electronic ISSN: 2191-219X
DOI
https://doi.org/10.1186/s13550-018-0367-7

Other articles of this Issue 1/2018

EJNMMI Research 1/2018 Go to the issue