Skip to main content
Top
Published in: The Ultrasound Journal 1/2021

Open Access 01-12-2021 | Ultrasound | Original article

Diagnostic accuracy of lung ultrasound for SARS-CoV-2: a retrospective cohort study

Authors: Daniel S. Brenner, Gigi Y. Liu, Rodney Omron, Olive Tang, Brian T. Garibaldi, Tiffany C. Fong

Published in: The Ultrasound Journal | Issue 1/2021

Login to get access

Abstract

Background

As medical infrastructures are strained by SARS-CoV-2, rapid and accurate screening tools are essential. In portions of the world, reverse transcription polymerase chain reaction (RT-PCR) testing remains slow and in limited supply, and computed tomography is expensive, inefficient, and involves exposure to ionizing radiation. Multiple studies evaluating the efficiency of lung point-of-care ultrasound (POCUS) have been published recently, but include relatively small cohorts and often focus on characteristics associated with severe illness rather than screening efficacy. This study utilizes a retrospective cohort to evaluate the test characteristics (sensitivity, specificity, likelihood ratios, predictive values) of lung POCUS in the diagnosis of SARS-CoV-2, and to determine lung score cutoffs that maximize performance for use as a screening tool.

Results

Lung POCUS examinations had sensitivity 86%, specificity 71.6%, NPV 81.7%, and PPV 77.7%. The Lung Ultrasound Score had an area under the curve of 0.84 (95% CI 0.78, 0.90). When including only complete examinations visualizing 12 lung fields, lung POCUS had sensitivity 90.9% and specificity 75.6%, with NPV 87.2% and PPV 82.0% and an area under the curve of 0.89 (95% CI 0.83, 0.96). Lung POCUS was less accurate in patients with a history of interstitial lung disease, severe emphysema, and heart failure.

Conclusions

When applied in the appropriate patient population, lung POCUS is an inexpensive and reliable tool for rapid screening and diagnosis of SARS-CoV-2 in symptomatic patients with influenza-like illness. Adoption of lung POCUS screening for SARS-CoV-2 may identify patients who do not require additional testing and reduce the need for RT-PCR testing in resource-limited environments and during surge periods.
Appendix
Available only for authorised users
Literature
4.
go back to reference Goldstein J, McKinley J (2020) 9-Day waits for test results threaten N.Y.C.’s ability to contain virus. The New York Times A1 Goldstein J, McKinley J (2020) 9-Day waits for test results threaten N.Y.C.’s ability to contain virus. The New York Times A1
22.
go back to reference Huang Y, Wang S, Liu Y, et al (2020) A preliminary study on the ultrasonic manifestations of peripulmonary lesions of non-critical novel coronavirus pneumonia (COVID-19). SSRN Huang Y, Wang S, Liu Y, et al (2020) A preliminary study on the ultrasonic manifestations of peripulmonary lesions of non-critical novel coronavirus pneumonia (COVID-19). SSRN
Metadata
Title
Diagnostic accuracy of lung ultrasound for SARS-CoV-2: a retrospective cohort study
Authors
Daniel S. Brenner
Gigi Y. Liu
Rodney Omron
Olive Tang
Brian T. Garibaldi
Tiffany C. Fong
Publication date
01-12-2021
Publisher
Springer International Publishing
Published in
The Ultrasound Journal / Issue 1/2021
Electronic ISSN: 2524-8987
DOI
https://doi.org/10.1186/s13089-021-00217-7

Other articles of this Issue 1/2021

The Ultrasound Journal 1/2021 Go to the issue