Skip to main content
Top
Published in: Journal of Orthopaedic Surgery and Research 1/2017

Open Access 01-12-2017 | Research article

Gallie technique versus atlantoaxial screw-rod constructs in the treatment of atlantoaxial sagittal instability: a retrospective study of 49 patients

Authors: Bo Yuan, Shengyuan Zhou, Xiongsheng Chen, Zhiwei Wang, Weicong Liu, Lianshun Jia

Published in: Journal of Orthopaedic Surgery and Research | Issue 1/2017

Login to get access

Abstract

Background

The objectives of this study are to investigate the clinical curative effect of Gallie technique and atlantoaxial screw-rod constructs (SRC) on atlantoaxial sagittal instability and determine the indication of Gallie technique.

Methods

Data of 49 patients with atlantoaxial sagittal instability from February 2008 to May 2015 were analyzed retrospectively. The visual analog scale (VAS) score and the neck disability index (NDI) were used to evaluate the curative effect. Postoperative radiological outcomes were used to evaluate the stability of atlantoaxial joint and bone fusion. Perioperative parameters such as blood loss, operation time, radiographic exposure times, and hospital expense were also recorded and analyzed.

Results

Forty-nine patients (36 men and 13 women) were included in this study. The mean age was 41.4 ± 8.9 (range from 19 to 64). All patients were followed up for 24–67 months. Among these patients, 25 of these patients underwent Gallie surgery and 24 underwent SRC surgery. The pain in the occipitocervical area of all the patients has been relieved. NDI scores and VAS scores were lower in Gallie group than in SRC group in early postoperative period. The proportion of the patients who achieved good bone fusion within 3 months after operation was 88.0% (22/25) in the Gallie group and 100% (24/24) in the SRC group. The Gallie group is lower than the SRC group in blood loss, operation time, radiographic exposure times, and hospital expense. Statistical difference was observed between the two groups.

Conclusions

For patients with atlantoaxial instability who has (1) the atlantodental interval (ADI) which is bigger than 5 mm on lateral flexion-extension X-ray, or Anderson-D’Alonzo type II odontoid fracture, (2) no asymmetry between odontoid process and lateral mass on open-mouth anterior-posterior X-ray, and (3) no dislocation of lateral mass joint on the CT 3D reconstruction, Gallie technique can be chosen as a safe and effective method if atlantoaxial reduction can be achieved preoperatively. Compared with SRC, Gallie technique can relieve the pain in the occipitocervical area earlier and it can shorten operation time and reduce intraoperative bleeding, radiographic exposure times, and hospital expense effectively. However, for patients with irreducible atlantoaxial dislocation, the Gallie technique should be used with caution.
Literature
4.
go back to reference Nightingale RW, Winkelstein BA, Knaub KE, Richardson WJ, Luck JF, Myers BS. Comparative strengths and structural properties of the upper and lower cervical spine in flexion and extension. J Biomech. 2002;35:725–32.CrossRefPubMed Nightingale RW, Winkelstein BA, Knaub KE, Richardson WJ, Luck JF, Myers BS. Comparative strengths and structural properties of the upper and lower cervical spine in flexion and extension. J Biomech. 2002;35:725–32.CrossRefPubMed
6.
go back to reference Gallie WE. Fractures and dislocations of the cervical spine. Am J Surg. 1939;46:495–9.CrossRef Gallie WE. Fractures and dislocations of the cervical spine. Am J Surg. 1939;46:495–9.CrossRef
7.
10.
go back to reference Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279–84.CrossRefPubMed Brooks AL, Jenkins EB. Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am. 1978;60:279–84.CrossRefPubMed
11.
go back to reference Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129:47–53.CrossRef Goel A, Laheri V. Plate and screw fixation for atlanto-axial subluxation. Acta Neurochir (Wien). 1994;129:47–53.CrossRef
12.
go back to reference Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26:2467–71.CrossRef Harms J, Melcher RP. Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976). 2001;26:2467–71.CrossRef
15.
go back to reference Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Frempong-Boadu A, Smith ML. Comparison of screw malposition and vertebral artery injury of C2 pedicle and transarticular screws: meta-analysis and review of the literature. J Spinal Disord Tech. 2014;27:305–15. doi:10.1097/BSD.0b013e31825d5daa.CrossRefPubMed Elliott RE, Tanweer O, Boah A, Morsi A, Ma T, Frempong-Boadu A, Smith ML. Comparison of screw malposition and vertebral artery injury of C2 pedicle and transarticular screws: meta-analysis and review of the literature. J Spinal Disord Tech. 2014;27:305–15. doi:10.​1097/​BSD.​0b013e31825d5daa​.CrossRefPubMed
18.
go back to reference El Masry MA, El Assuity WI, Sadek FZ, Salah H. Two methods of atlantoaxial stabilisation for atlantoaxial instability. Acta Orthop Belg. 2007;73:741.PubMed El Masry MA, El Assuity WI, Sadek FZ, Salah H. Two methods of atlantoaxial stabilisation for atlantoaxial instability. Acta Orthop Belg. 2007;73:741.PubMed
19.
go back to reference Grob D, Crisco JR, Panjabi MM, Wang P, Dvorak J. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976). 1992;17:480–90.CrossRef Grob D, Crisco JR, Panjabi MM, Wang P, Dvorak J. Biomechanical evaluation of four different posterior atlantoaxial fixation techniques. Spine (Phila Pa 1976). 1992;17:480–90.CrossRef
20.
23.
go back to reference Li-Jun L, Ying-Chao H, Ming-Jie Y, Jie P, Jun T, Dong-Sheng Z. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability. Spinal Cord. 2014;52:342–7. doi:10.1038/sc.2014.8.CrossRefPubMed Li-Jun L, Ying-Chao H, Ming-Jie Y, Jie P, Jun T, Dong-Sheng Z. Biomechanical analysis of the longitudinal ligament of upper cervical spine in maintaining atlantoaxial stability. Spinal Cord. 2014;52:342–7. doi:10.​1038/​sc.​2014.​8.CrossRefPubMed
27.
Metadata
Title
Gallie technique versus atlantoaxial screw-rod constructs in the treatment of atlantoaxial sagittal instability: a retrospective study of 49 patients
Authors
Bo Yuan
Shengyuan Zhou
Xiongsheng Chen
Zhiwei Wang
Weicong Liu
Lianshun Jia
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Journal of Orthopaedic Surgery and Research / Issue 1/2017
Electronic ISSN: 1749-799X
DOI
https://doi.org/10.1186/s13018-017-0607-y

Other articles of this Issue 1/2017

Journal of Orthopaedic Surgery and Research 1/2017 Go to the issue