Skip to main content
Top
Published in: Scoliosis and Spinal Disorders 1/2017

Open Access 01-12-2017 | Research

Adolescents with idiopathic scoliosis and their parents have a positive attitude towards the Thermobrace monitor: results from a survey

Authors: Sabrina Donzelli, Fabio Zaina, Gregorio Martinez, Francesca Di Felice, Alberto Negrini, Stefano Negrini

Published in: Scoliosis and Spinal Disorders | Issue 1/2017

Login to get access

Abstract

Background

A temperature monitor is used to objectively measure brace wear time in adolescent idiopathic scoliosis. The reliability of this device have been demonstrated, and some specialists introduced the use of a compliance monitor as a standard of care in everyday clinical practice, as we did since 2010 with the Thermobrace (TB). The attitude towards these objective monitors has never been investigated.
The present study aims to investigate the attitude of parents and patients towards the use of temperature sensors for measuring brace wear compliance.

Methods

Three hundred one consecutive girls and 63 boys and their parents have been interviewed. The inclusion criteria were as follows: brace wear full-time prescription at first visit and at least one visit with download and discussion of TB data.
Usefulness, acceptability, reliability, and feeling related to data download were the investigated domains. Patients were invited by the administrative staff to complete anonymously the questionnaire. The European Commission was informed about the present survey and approved it (ICT-37-2015-1). Descriptive statistic was used to present the results.

Results

Among the 364 invited patients and parents, 336 adhered by completing it (rate of responders was 93.2%). The mean age was 14.65 (SD 2.36), the mean Cobb angle was 34.18 (SD 13.57), and the average brace wear prescription was 21.76 h per day (SD 2.53). We did not ask parents about their age, profession, nor other personal data.
Globally, the interviewed patients and parents showed a very positive attitude towards the TB monitor: the mean rate of parents stating a completely or at least partially positive attitude towards this electronic device was 94.0% while among patients, it was 85.6%.

Conclusions

This is the first study investigating the attitude of parents and patients towards a brace wear compliance monitor. People who experienced this objective monitoring are aware of the advantages related to it and support its usefulness not only for clinicians but also for patients and parents to respect the hours prescribed without any affection on the children and parents or the patient-physician relationship. The present results should encourage the spread of these tools in daily clinical practice.
Appendix
Available only for authorised users
Literature
2.
go back to reference Caronni A, Zaina F, Negrini S. Improving the measurement of health-related quality of life in adolescent with idiopathic scoliosis: the SRS-7, a Rasch-developed short form of the SRS-22 questionnaire. Res Dev Disabil. 2014;35(4):784–99.CrossRefPubMed Caronni A, Zaina F, Negrini S. Improving the measurement of health-related quality of life in adolescent with idiopathic scoliosis: the SRS-7, a Rasch-developed short form of the SRS-22 questionnaire. Res Dev Disabil. 2014;35(4):784–99.CrossRefPubMed
3.
go back to reference Aulisa AG, Guzzanti V, Perisano C, Marzetti E, Specchia A, Galli M, et al. Determination of quality of life in adolescents with idiopathic scoliosis subjected to conservative treatment. Scoliosis. 2010;5:21.CrossRefPubMedPubMedCentral Aulisa AG, Guzzanti V, Perisano C, Marzetti E, Specchia A, Galli M, et al. Determination of quality of life in adolescents with idiopathic scoliosis subjected to conservative treatment. Scoliosis. 2010;5:21.CrossRefPubMedPubMedCentral
4.
go back to reference Brox JI, Lange JE, Gunderson RB, Steen H. Good brace compliance reduced curve progression and surgical rates in patients with idiopathic scoliosis. Eur Spine J. 2012;21(10):1957–63.CrossRefPubMedPubMedCentral Brox JI, Lange JE, Gunderson RB, Steen H. Good brace compliance reduced curve progression and surgical rates in patients with idiopathic scoliosis. Eur Spine J. 2012;21(10):1957–63.CrossRefPubMedPubMedCentral
5.
go back to reference Morton A, Riddle R, Buchanan R, Katz D, Birch J. Accuracy in the prediction and estimation of adherence to bracewear before and during treatment of adolescent idiopathic scoliosis. J Pediatr Orthop. 2008;28(3):336–41.CrossRefPubMed Morton A, Riddle R, Buchanan R, Katz D, Birch J. Accuracy in the prediction and estimation of adherence to bracewear before and during treatment of adolescent idiopathic scoliosis. J Pediatr Orthop. 2008;28(3):336–41.CrossRefPubMed
6.
go back to reference Havey R, Gavin T, Patwardhan A, Pawelczak S, Ibrahim K, Andersson GBJ, et al. A reliable and accurate method for measuring orthosis wearing time. Spine. 2002;27(2):211–4.CrossRefPubMed Havey R, Gavin T, Patwardhan A, Pawelczak S, Ibrahim K, Andersson GBJ, et al. A reliable and accurate method for measuring orthosis wearing time. Spine. 2002;27(2):211–4.CrossRefPubMed
7.
go back to reference Wiley JW, Thomson JD, Mitchell TM, Smith BG, Banta JV. Effectiveness of the Boston brace in treatment of large curves in adolescent idiopathic scoliosis. Spine. 2000;25(18):2326–32.CrossRefPubMed Wiley JW, Thomson JD, Mitchell TM, Smith BG, Banta JV. Effectiveness of the Boston brace in treatment of large curves in adolescent idiopathic scoliosis. Spine. 2000;25(18):2326–32.CrossRefPubMed
8.
go back to reference Vandal S, Rivard CH, Bradet R. Measuring the compliance behavior of adolescents wearing orthopedic braces. Issues Compr Pediatr Nurs. 1999;22(2-3):59–73.CrossRefPubMed Vandal S, Rivard CH, Bradet R. Measuring the compliance behavior of adolescents wearing orthopedic braces. Issues Compr Pediatr Nurs. 1999;22(2-3):59–73.CrossRefPubMed
9.
go back to reference Rahman T, Borkhuu B, Littleton AG, Sample W, Moran E, Campbell S, et al. Electronic monitoring of scoliosis brace wear compliance. J Child Orthop. 2010;4(4):343–7.CrossRefPubMedPubMedCentral Rahman T, Borkhuu B, Littleton AG, Sample W, Moran E, Campbell S, et al. Electronic monitoring of scoliosis brace wear compliance. J Child Orthop. 2010;4(4):343–7.CrossRefPubMedPubMedCentral
10.
go back to reference Takemitsu M, Bowen JR, Rahman T, Glutting JJ, Scott CB. Compliance monitoring of brace treatment for patients with idiopathic scoliosis. Spine. 2004;29(18):2070–4. discussion 2074.CrossRefPubMed Takemitsu M, Bowen JR, Rahman T, Glutting JJ, Scott CB. Compliance monitoring of brace treatment for patients with idiopathic scoliosis. Spine. 2004;29(18):2070–4. discussion 2074.CrossRefPubMed
11.
go back to reference Dolan LA, Wright JG, Weinstein SL. Effects of bracing in adolescents with idiopathic scoliosis. N Engl J Med. 2014;370(7):681.CrossRefPubMed Dolan LA, Wright JG, Weinstein SL. Effects of bracing in adolescents with idiopathic scoliosis. N Engl J Med. 2014;370(7):681.CrossRefPubMed
12.
13.
go back to reference Katz DE, Herring JA, Browne RH, Kelly DM, Birch JG. Brace wear control of curve progression in adolescent idiopathic scoliosis. J Bone Joint Surg Am. 2010;92(6):1343–52.CrossRefPubMed Katz DE, Herring JA, Browne RH, Kelly DM, Birch JG. Brace wear control of curve progression in adolescent idiopathic scoliosis. J Bone Joint Surg Am. 2010;92(6):1343–52.CrossRefPubMed
14.
go back to reference Landauer F, Wimmer C, Behensky H. Estimating the final outcome of brace treatment for idiopathic thoracic scoliosis at 6-month follow-up. Pediatr Rehabil. 2003;6(3-4):201–7.CrossRefPubMed Landauer F, Wimmer C, Behensky H. Estimating the final outcome of brace treatment for idiopathic thoracic scoliosis at 6-month follow-up. Pediatr Rehabil. 2003;6(3-4):201–7.CrossRefPubMed
15.
go back to reference Donzelli S, Zaina F, Negrini S. In defense of adolescents: they really do use braces for the hours prescribed, if good help is provided. Results from a prospective everyday clinic cohort using thermobrace. Scoliosis. 2012;7(1):12.CrossRefPubMedPubMedCentral Donzelli S, Zaina F, Negrini S. In defense of adolescents: they really do use braces for the hours prescribed, if good help is provided. Results from a prospective everyday clinic cohort using thermobrace. Scoliosis. 2012;7(1):12.CrossRefPubMedPubMedCentral
16.
go back to reference Reinker KA. Compliance counseling improves outcomes of bracing for patients with idiopathic scoliosis: commentary on an article by Lori A. Karol, MD, et al.: “Effect of compliance counseling on brace use and success in patients with adolescent idiopathic scoliosis”. J Bone Joint Surg Am. 2016;98(1):e4.CrossRefPubMed Reinker KA. Compliance counseling improves outcomes of bracing for patients with idiopathic scoliosis: commentary on an article by Lori A. Karol, MD, et al.: “Effect of compliance counseling on brace use and success in patients with adolescent idiopathic scoliosis”. J Bone Joint Surg Am. 2016;98(1):e4.CrossRefPubMed
17.
go back to reference Negrini A, Donzelli S, Lusini M, Minnella S, Zaina F, Negrini S. A cognitive behavioral approach allows improving brace wearing compliance: an observational controlled retrospective study with thermobrace. Scoliosis. 2014;9 Suppl 1:O79.CrossRefPubMedCentral Negrini A, Donzelli S, Lusini M, Minnella S, Zaina F, Negrini S. A cognitive behavioral approach allows improving brace wearing compliance: an observational controlled retrospective study with thermobrace. Scoliosis. 2014;9 Suppl 1:O79.CrossRefPubMedCentral
18.
go back to reference Negrini S, Hresko TM, O’Brien JP, Price N, SOSORT Boards, SRS Non-Operative Committee. Recommendations for research studies on treatment of idiopathic scoliosis: consensus 2014 between SOSORT and SRS non-operative management committee. Scoliosis. 2015;10:8.CrossRefPubMedPubMedCentral Negrini S, Hresko TM, O’Brien JP, Price N, SOSORT Boards, SRS Non-Operative Committee. Recommendations for research studies on treatment of idiopathic scoliosis: consensus 2014 between SOSORT and SRS non-operative management committee. Scoliosis. 2015;10:8.CrossRefPubMedPubMedCentral
19.
go back to reference Benish BM, Smith KJ, Schwartz MH. Validation of a miniature thermochron for monitoring thoracolumbosacral orthosis wear time. Spine. 2012;37(4):309–15.CrossRefPubMed Benish BM, Smith KJ, Schwartz MH. Validation of a miniature thermochron for monitoring thoracolumbosacral orthosis wear time. Spine. 2012;37(4):309–15.CrossRefPubMed
20.
go back to reference Rahman T, Sample W, Yorgova P, Neiss G, Rogers K, Shah S, et al. Electronic monitoring of orthopedic brace compliance. J Child Orthop. 2015;28:1–5. Rahman T, Sample W, Yorgova P, Neiss G, Rogers K, Shah S, et al. Electronic monitoring of orthopedic brace compliance. J Child Orthop. 2015;28:1–5.
22.
go back to reference Negrini S, Fusco C, Romano M, Zaina F, Atanasio S. Clinical and postural behaviour of scoliosis during daily brace weaning hours. Stud Health Technol Inform. 2008;140:303–6.PubMed Negrini S, Fusco C, Romano M, Zaina F, Atanasio S. Clinical and postural behaviour of scoliosis during daily brace weaning hours. Stud Health Technol Inform. 2008;140:303–6.PubMed
23.
go back to reference Tavernaro M, Pellegrini A, Tessadri F, Zaina F, Zonta A, Negrini S. Team care to cure adolescents with braces (avoiding low quality of life, pain and bad compliance): a case-control retrospective study. 2011 SOSORT Award winner. Scoliosis. 2012;7(1):17.CrossRefPubMedPubMedCentral Tavernaro M, Pellegrini A, Tessadri F, Zaina F, Zonta A, Negrini S. Team care to cure adolescents with braces (avoiding low quality of life, pain and bad compliance): a case-control retrospective study. 2011 SOSORT Award winner. Scoliosis. 2012;7(1):17.CrossRefPubMedPubMedCentral
24.
go back to reference Negrini S, Aulisa AG, Aulisa L, Circo AB, de Mauroy JC, Durmala J, et al. 2011 SOSORT guidelines: orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. Scoliosis. 2012;7(1):3.CrossRefPubMedPubMedCentral Negrini S, Aulisa AG, Aulisa L, Circo AB, de Mauroy JC, Durmala J, et al. 2011 SOSORT guidelines: orthopaedic and rehabilitation treatment of idiopathic scoliosis during growth. Scoliosis. 2012;7(1):3.CrossRefPubMedPubMedCentral
Metadata
Title
Adolescents with idiopathic scoliosis and their parents have a positive attitude towards the Thermobrace monitor: results from a survey
Authors
Sabrina Donzelli
Fabio Zaina
Gregorio Martinez
Francesca Di Felice
Alberto Negrini
Stefano Negrini
Publication date
01-12-2017
Publisher
BioMed Central
Published in
Scoliosis and Spinal Disorders / Issue 1/2017
Electronic ISSN: 2397-1789
DOI
https://doi.org/10.1186/s13013-017-0119-x

Other articles of this Issue 1/2017

Scoliosis and Spinal Disorders 1/2017 Go to the issue