Skip to main content
Top
Published in: Cardiovascular Ultrasound 1/2021

Open Access 01-12-2021 | Transesophageal Echocardiography | Research

Safety and effects of volume loading during transesophageal echocardiography in the pre-procedural work-up for left atrial appendage closure

Authors: Afonso B. Freitas-Ferraz, Mathieu Bernier, Kim O’Connor, Jonathan Beaudoin, Jean Champagne, Jean-Michel Paradis, Gilles O’Hara, Guillem Muntané- Carol, Alberto Alperi, Laurent Faroux, Lucia Junquera, Josep Rodés-Cabau

Published in: Cardiovascular Ultrasound | Issue 1/2021

Login to get access

Abstract

Background

In patients undergoing left atrial appendage (LAA) closure, an accurate sizing of the LAA is key to optimize device sizing, procedural success and reduce complications. Previous studies have shown that intraprocedural volume loading increases LAA dimensions and improves device sizing. However, the safety and effects on LAA and device sizing of administering a fluid bolus during pre-procedural transesophageal echocardiography (TEE) are unknown. The aim of this study was to determine the safety and impact on LAA dimensions and device sizing of an intravenous (IV) fluid bolus administered during TEE in the setting of the pre-procedural work-up for LAA closure.

Methods

The study included a total of 72 patients who underwent TEE to assess suitability for LAAC and received a 500 ml IV bolus of normal saline. The LAA landing zone (LZ) and depth were measured by TEE before and after volume loading, and these measurements were used to predict the device size implanted during a subsequent percutaneous LAAC procedure.

Results

There were no complications associated with volume loading. The baseline mean LZ was 19.6 ± 3.6 mm at 90o, and 20.2 ± 4.1 mm at 135o. Following fluid bolus, the maximum diameter increased 1.5 ± 1.0 mm at 90o (p<0.001), and 1.3 ± 1.0 mm at 135o (p<0.001). The baseline mean depth of the LAA was 26.5 ± 5.5 mm at 90o, and 23.9 ± 5.8 mm at 135o. After fluid bolus, the mean depth increased by 1.5 ± 1.8 mm (p<0.001) and 1.6 ± 2.0 (p<0.001), at 90o and 135o, respectively. Sizing based on post-bolus measurements of the LZ significantly improved the agreement with the final device size selection during the procedure in 71.0% of cases (vs. 42.0% with pre-bolus measurements).

Conclusions

Volume loading during ambulatory TEE as part of the pre-procedural work-up of LAAC is safe and significantly increases LAA dimensions. This strategy may become the new standard, particularly in centers performing LAAC with no TEE guidance, as it improves LAA sizing and more accurately predicts the final device size.
Literature
4.
go back to reference January CT, Wann LS, Calkins H, et al. 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society in Collaboration With the Society of Thoracic Surgeons. Circulation. 2019;140(2):e125–51. DOI:https://doi.org/10.1161/cir.0000000000000665.CrossRefPubMed January CT, Wann LS, Calkins H, et al. 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society in Collaboration With the Society of Thoracic Surgeons. Circulation. 2019;140(2):e125–51. DOI:https://​doi.​org/​10.​1161/​cir.​0000000000000665​.CrossRefPubMed
8.
go back to reference Al-Kassou B, Tzikas A, Stock F, Neikes F, Völz A, Omran H. A comparison of two-dimensional and real-time 3D transoesophageal echocardiography and angiography for assessing the left atrial appendage anatomy for sizing a left atrial appendage occlusion system: impact of volume loading. EuroIntervention. 2017;12(17):2083–91. https://doi.org/10.4244/eij-d-15-00543.CrossRefPubMed Al-Kassou B, Tzikas A, Stock F, Neikes F, Völz A, Omran H. A comparison of two-dimensional and real-time 3D transoesophageal echocardiography and angiography for assessing the left atrial appendage anatomy for sizing a left atrial appendage occlusion system: impact of volume loading. EuroIntervention. 2017;12(17):2083–91. https://​doi.​org/​10.​4244/​eij-d-15-00543.CrossRefPubMed
Metadata
Title
Safety and effects of volume loading during transesophageal echocardiography in the pre-procedural work-up for left atrial appendage closure
Authors
Afonso B. Freitas-Ferraz
Mathieu Bernier
Kim O’Connor
Jonathan Beaudoin
Jean Champagne
Jean-Michel Paradis
Gilles O’Hara
Guillem Muntané- Carol
Alberto Alperi
Laurent Faroux
Lucia Junquera
Josep Rodés-Cabau
Publication date
01-12-2021
Publisher
BioMed Central
Published in
Cardiovascular Ultrasound / Issue 1/2021
Electronic ISSN: 1476-7120
DOI
https://doi.org/10.1186/s12947-020-00230-1

Other articles of this Issue 1/2021

Cardiovascular Ultrasound 1/2021 Go to the issue