Abstract

Background

The abrasion behavior of various ceramics is rarely investigated, though it is relevant for the clinical success of such restorations. The aim of this in vivo study was to evaluate the wear of feldspathic-ceramic-veneered zirconium oxide frameworks over a period of at least 10 years.

Methods

The abrasion behavior of 15 bridge constructions from 15 different participants was examined after a period of 3, 5, and 10 years using plaster models, which were then subjected to a scanning process on the Atos II industrial scanner and digitized for three-dimensional evaluation of the abrasion by the corresponding software (ATOS Professional 7.6). The individual post-examination models were compared to the baseline model and deviations calculated in the sense of the largest, punctual loss of material in millimeters (“minimal distance”), the average abrasion in millimeters (“mean distance”), and the volume decrease in cubic millimeters (“integrated distance”). Statistical analyses were performed using the Wilcoxon sign rank test or mixed regression models. Multiple testing was considered by Benjamini-Hochberg correction. The significance level was set at 0.05.

Results

We found steadily increasing wear of the ceramic. The average volume decrease was significant (P < 0.001) at 3 years and 10 years (− 3.25 mm3 and − 8.11 mm3, respectively).

Conclusions

The results of this study indicate that the rate of volume loss in feldspathic-ceramic-veneered zirconia frameworks in the posterior region increases significantly over time. An increasing frequency of parameters was observed, particularly in the second half of the study period. However, the use of this class of materials can be considered clinically acceptable.
Trial registration This study is registered in DRKS - German Clinical Trials Register with the register number DRKS00021743. https://​www.​drks.​de/​drks_​web/​navigate.​do?​navigationId=​trial.​HTML&​TRIAL_​ID=​DRKS00021743
Literature
2.
go back to reference Dupriez ND, von Koeckritz AK, Kunzelmann KH. A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms. J Biomed Mater Res B Appl Biomater. 2015;103(4):925–34.PubMedCrossRef Dupriez ND, von Koeckritz AK, Kunzelmann KH. A comparative study of sliding wear of nonmetallic dental restorative materials with emphasis on micromechanical wear mechanisms. J Biomed Mater Res B Appl Biomater. 2015;103(4):925–34.PubMedCrossRef
3.
go back to reference Yip KH, Smales RJ, Kaidonis JA. Differential wear of teeth and restorative materials: clinical implications. Int J Prosthodont. 2004;17(3):350–6.PubMed Yip KH, Smales RJ, Kaidonis JA. Differential wear of teeth and restorative materials: clinical implications. Int J Prosthodont. 2004;17(3):350–6.PubMed
4.
go back to reference DeLong R. Intra-oral restorative materials wear: rethinking the current approaches: how to measure wear. Dent Mater. 2006;22(8):702–11.PubMedCrossRef DeLong R. Intra-oral restorative materials wear: rethinking the current approaches: how to measure wear. Dent Mater. 2006;22(8):702–11.PubMedCrossRef
6.
go back to reference Kelly JR, Rose TC. Nonprecious alloys for use in fixed prosthodontics: a literature review. J Prosthet Dent. 1983;49(3):363–70.PubMedCrossRef Kelly JR, Rose TC. Nonprecious alloys for use in fixed prosthodontics: a literature review. J Prosthet Dent. 1983;49(3):363–70.PubMedCrossRef
7.
go back to reference Ramp MH, et al. Evaluation of wear: enamel opposing three ceramic materials and a gold alloy. J Prosthet Dent. 1997;77(5):523–30.PubMedCrossRef Ramp MH, et al. Evaluation of wear: enamel opposing three ceramic materials and a gold alloy. J Prosthet Dent. 1997;77(5):523–30.PubMedCrossRef
8.
go back to reference Graf K, et al. The influence of dental alloys on three-body wear of human enamel and dentin in an inlay-like situation. Oper Dent. 2002;27(2):167–74.PubMed Graf K, et al. The influence of dental alloys on three-body wear of human enamel and dentin in an inlay-like situation. Oper Dent. 2002;27(2):167–74.PubMed
9.
go back to reference Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002;87(4):451–9.PubMedCrossRef Oh WS, Delong R, Anusavice KJ. Factors affecting enamel and ceramic wear: a literature review. J Prosthet Dent. 2002;87(4):451–9.PubMedCrossRef
11.
go back to reference Spear F, Holloway J. Which all-ceramic system is optimal for anterior esthetics? J Am Dent Assoc. 2008;139(Suppl):19S–24S.PubMedCrossRef Spear F, Holloway J. Which all-ceramic system is optimal for anterior esthetics? J Am Dent Assoc. 2008;139(Suppl):19S–24S.PubMedCrossRef
12.
go back to reference Nayar S, Aruna U, Bhat WM. Enhanced aesthetics with all ceramics restoration. J Pharm Bioallied Sci. 2015;7(Suppl 1):S282–4.PubMedPubMedCentral Nayar S, Aruna U, Bhat WM. Enhanced aesthetics with all ceramics restoration. J Pharm Bioallied Sci. 2015;7(Suppl 1):S282–4.PubMedPubMedCentral
13.
go back to reference Vagkopoulou T, et al. Zirconia in dentistry: part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent. 2009;4(2):130–51.PubMed Vagkopoulou T, et al. Zirconia in dentistry: part 1. Discovering the nature of an upcoming bioceramic. Eur J Esthet Dent. 2009;4(2):130–51.PubMed
14.
go back to reference Hisbergues M, Vendeville S, Vendeville P. Zirconia: established facts and perspectives for a biomaterial in dental implantology. J Biomed Mater Res B Appl Biomater. 2009;88(2):519–29.PubMedCrossRef Hisbergues M, Vendeville S, Vendeville P. Zirconia: established facts and perspectives for a biomaterial in dental implantology. J Biomed Mater Res B Appl Biomater. 2009;88(2):519–29.PubMedCrossRef
15.
go back to reference Pittayachawan P, et al. Flexural strength, fatigue life, and stress-induced phase transformation study of Y-TZP dental ceramic. J Biomed Mater Res B Appl Biomater. 2009;88(2):366–77.PubMedCrossRef Pittayachawan P, et al. Flexural strength, fatigue life, and stress-induced phase transformation study of Y-TZP dental ceramic. J Biomed Mater Res B Appl Biomater. 2009;88(2):366–77.PubMedCrossRef
16.
go back to reference Sturzenegger B, et al. Clinical study of zirconium oxide bridges in the posterior segments fabricated with the DCM system. Schweiz Monatsschr Zahnmed. 2000;110(12):131–9.PubMed Sturzenegger B, et al. Clinical study of zirconium oxide bridges in the posterior segments fabricated with the DCM system. Schweiz Monatsschr Zahnmed. 2000;110(12):131–9.PubMed
17.
go back to reference Filser F, et al. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent. 2001;4(2):89–106.PubMed Filser F, et al. Reliability and strength of all-ceramic dental restorations fabricated by direct ceramic machining (DCM). Int J Comput Dent. 2001;4(2):89–106.PubMed
18.
go back to reference Luthy H, et al. Strength and reliability of four-unit all-ceramic posterior bridges. Dent Mater. 2005;21(10):930–7.PubMedCrossRef Luthy H, et al. Strength and reliability of four-unit all-ceramic posterior bridges. Dent Mater. 2005;21(10):930–7.PubMedCrossRef
19.
go back to reference Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil. 2005;32(3):180–7.PubMedCrossRef Vult von Steyern P, Carlson P, Nilner K. All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study. J Oral Rehabil. 2005;32(3):180–7.PubMedCrossRef
20.
go back to reference Sailer I, et al. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int. 2006;37(9):685–93.PubMed Sailer I, et al. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int. 2006;37(9):685–93.PubMed
21.
go back to reference Sailer I, et al. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20(4):383–8.PubMed Sailer I, et al. Five-year clinical results of zirconia frameworks for posterior fixed partial dentures. Int J Prosthodont. 2007;20(4):383–8.PubMed
22.
go back to reference Kontonasaki E, et al. Monolithic zirconia: an update to current knowledge. optical properties, wear, and clinical performance. Dent J (Basel). 2019;7(3):90.CrossRef Kontonasaki E, et al. Monolithic zirconia: an update to current knowledge. optical properties, wear, and clinical performance. Dent J (Basel). 2019;7(3):90.CrossRef
23.
go back to reference Suarez MJ, et al. A randomized clinical trial comparing zirconia and metal-ceramic three-unit posterior fixed partial dentures: a 5-year follow-up. J Prosthodont. 2019;28(7):750–6.PubMedCrossRef Suarez MJ, et al. A randomized clinical trial comparing zirconia and metal-ceramic three-unit posterior fixed partial dentures: a 5-year follow-up. J Prosthodont. 2019;28(7):750–6.PubMedCrossRef
24.
go back to reference Teichmann M, et al. Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses. Clin Oral Investig. 2018;22(8):2905–15.PubMedCrossRef Teichmann M, et al. Ten-year survival and chipping rates and clinical quality grading of zirconia-based fixed dental prostheses. Clin Oral Investig. 2018;22(8):2905–15.PubMedCrossRef
25.
go back to reference Chaar MS, Passia N, Kern M. Ten-year clinical outcome of three-unit posterior FDPs made from a glass-infiltrated zirconia reinforced alumina ceramic (in-Ceram zirconia). J Dent. 2015;43(5):512–7.PubMedCrossRef Chaar MS, Passia N, Kern M. Ten-year clinical outcome of three-unit posterior FDPs made from a glass-infiltrated zirconia reinforced alumina ceramic (in-Ceram zirconia). J Dent. 2015;43(5):512–7.PubMedCrossRef
26.
go back to reference Kern M, Sasse M, Wolfart S. Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic. J Am Dent Assoc. 2012;143(3):234–40.PubMedCrossRef Kern M, Sasse M, Wolfart S. Ten-year outcome of three-unit fixed dental prostheses made from monolithic lithium disilicate ceramic. J Am Dent Assoc. 2012;143(3):234–40.PubMedCrossRef
27.
go back to reference Holst S, et al. A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: application of a triple-scan protocol. J Dent Biomech. 2012;3:1758736012452181.PubMedPubMedCentralCrossRef Holst S, et al. A technique for in vitro fit assessment of multi-unit screw-retained implant restorations: application of a triple-scan protocol. J Dent Biomech. 2012;3:1758736012452181.PubMedPubMedCentralCrossRef
28.
go back to reference Jeon JH, et al. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. J Prosthet Dent. 2015;114(4):549–53.PubMedCrossRef Jeon JH, et al. Three-dimensional evaluation of the repeatability of scanned conventional impressions of prepared teeth generated with white- and blue-light scanners. J Prosthet Dent. 2015;114(4):549–53.PubMedCrossRef
29.
go back to reference Jeon JH, et al. Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner. Dent Mater J. 2015;34(5):686–91.PubMedCrossRef Jeon JH, et al. Three-dimensional evaluation of the repeatability of scans of stone models and impressions using a blue LED scanner. Dent Mater J. 2015;34(5):686–91.PubMedCrossRef
30.
go back to reference Holst S, Tawdrous R, Karl M. Description of a Novel Technique for Three-Dimensional Fit Assessment of Dental Restorations. In: 6th World Congress of Biomechanics (WCB 2010). Singapore: Springer; 2010. Holst S, Tawdrous R, Karl M. Description of a Novel Technique for Three-Dimensional Fit Assessment of Dental Restorations. In: 6th World Congress of Biomechanics (WCB 2010). Singapore: Springer; 2010.
31.
go back to reference Jeon JH, et al. Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision. J Adv Prosthodont. 2014;6(6):468–73.PubMedPubMedCentralCrossRef Jeon JH, et al. Accuracy of 3D white light scanning of abutment teeth impressions: evaluation of trueness and precision. J Adv Prosthodont. 2014;6(6):468–73.PubMedPubMedCentralCrossRef
32.
go back to reference Holst S, et al. A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int. 2011;42(8):651–7.PubMed Holst S, et al. A new triple-scan protocol for 3D fit assessment of dental restorations. Quintessence Int. 2011;42(8):651–7.PubMed
33.
go back to reference Monasky GE, Taylor DF. Studies on the wear of porcelain, enamel, and gold. J Prosthet Dent. 1971;25(3):299–306.PubMedCrossRef Monasky GE, Taylor DF. Studies on the wear of porcelain, enamel, and gold. J Prosthet Dent. 1971;25(3):299–306.PubMedCrossRef
34.
go back to reference Rinke S, et al. Prospective evaluation of posterior fixed zirconia dental prostheses: 10-year clinical results. Int J Prosthodont. 2018;31(1):35–42.PubMedCrossRef Rinke S, et al. Prospective evaluation of posterior fixed zirconia dental prostheses: 10-year clinical results. Int J Prosthodont. 2018;31(1):35–42.PubMedCrossRef
35.
go back to reference Sailer I, et al. 10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses. J Dent. 2018;76:32–9.PubMedCrossRef Sailer I, et al. 10-year randomized trial (RCT) of zirconia-ceramic and metal-ceramic fixed dental prostheses. J Dent. 2018;76:32–9.PubMedCrossRef
36.
go back to reference Zurek AD, et al. Wear characteristics and volume loss of CAD/CAM ceramic materials. J Prosthodont. 2019;28(2):e510–8.PubMedCrossRef Zurek AD, et al. Wear characteristics and volume loss of CAD/CAM ceramic materials. J Prosthodont. 2019;28(2):e510–8.PubMedCrossRef
37.
go back to reference Samet N, et al. A clinical evaluation of fixed partial denture impressions. J Prosthet Dent. 2005;94(2):112–7.PubMedCrossRef Samet N, et al. A clinical evaluation of fixed partial denture impressions. J Prosthet Dent. 2005;94(2):112–7.PubMedCrossRef
38.
go back to reference Tomita Y, et al. Accuracy of digital models generated by conventional impression/plaster-model methods and intraoral scanning. Dent Mater J. 2018;37(4):628–33.PubMedCrossRef Tomita Y, et al. Accuracy of digital models generated by conventional impression/plaster-model methods and intraoral scanning. Dent Mater J. 2018;37(4):628–33.PubMedCrossRef
39.
go back to reference Nedelcu R, et al. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method. J Dent. 2018;69:110–8.PubMedCrossRef Nedelcu R, et al. Accuracy and precision of 3 intraoral scanners and accuracy of conventional impressions: a novel in vivo analysis method. J Dent. 2018;69:110–8.PubMedCrossRef
40.
go back to reference Nedelcu R, et al. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison. BMC Oral Health. 2018;18(1):27.PubMedPubMedCentralCrossRef Nedelcu R, et al. Finish line distinctness and accuracy in 7 intraoral scanners versus conventional impression: an in vitro descriptive comparison. BMC Oral Health. 2018;18(1):27.PubMedPubMedCentralCrossRef
41.
go back to reference Swain MV. Impact of oral fluids on dental ceramics: what is the clinical relevance? Dent Mater. 2014;30(1):33–42.PubMedCrossRef Swain MV. Impact of oral fluids on dental ceramics: what is the clinical relevance? Dent Mater. 2014;30(1):33–42.PubMedCrossRef
43.
go back to reference Milleding P, Haraldsson C, Karlsson S. Ion leaching from dental ceramics during static in vitro corrosion testing. J Biomed Mater Res. 2002;61(4):541–50.PubMedCrossRef Milleding P, Haraldsson C, Karlsson S. Ion leaching from dental ceramics during static in vitro corrosion testing. J Biomed Mater Res. 2002;61(4):541–50.PubMedCrossRef
44.
go back to reference Ghazal M, Kern M. The influence of antagonistic surface roughness on the wear of human enamel and nanofilled composite resin artificial teeth. J Prosthet Dent. 2009;101(5):342–9.PubMedCrossRef Ghazal M, Kern M. The influence of antagonistic surface roughness on the wear of human enamel and nanofilled composite resin artificial teeth. J Prosthet Dent. 2009;101(5):342–9.PubMedCrossRef
45.
go back to reference Suputtamongkol K, et al. Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns. Dent Mater. 2008;24(5):667–73.PubMedCrossRef Suputtamongkol K, et al. Clinical performance and wear characteristics of veneered lithia-disilicate-based ceramic crowns. Dent Mater. 2008;24(5):667–73.PubMedCrossRef
46.
go back to reference Stober T, et al. Occlusal wear of metal-free ceramic-filled polymer crowns after 2 years in service. Int J Prosthodont. 2008;21(2):161–5.PubMed Stober T, et al. Occlusal wear of metal-free ceramic-filled polymer crowns after 2 years in service. Int J Prosthodont. 2008;21(2):161–5.PubMed
47.
go back to reference Howell AH, Brudevold F. Vertical forces used during chewing of food. J Dent Res. 1950;29(2):133–6.PubMedCrossRef Howell AH, Brudevold F. Vertical forces used during chewing of food. J Dent Res. 1950;29(2):133–6.PubMedCrossRef
48.
go back to reference Mundhe K, et al. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent. 2015;114(3):358–63.PubMedCrossRef Mundhe K, et al. Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crowns. J Prosthet Dent. 2015;114(3):358–63.PubMedCrossRef
49.
go back to reference Esquivel-Upshaw JF, et al. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J Dent. 2018;68:19–27.PubMedCrossRef Esquivel-Upshaw JF, et al. Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crowns. J Dent. 2018;68:19–27.PubMedCrossRef
50.
go back to reference D'Arcangelo C, et al. Wear properties of dental ceramics and porcelains compared with human enamel. J Prosthet Dent. 2016;115(3):350–5.PubMedCrossRef D'Arcangelo C, et al. Wear properties of dental ceramics and porcelains compared with human enamel. J Prosthet Dent. 2016;115(3):350–5.PubMedCrossRef
51.
go back to reference Rashid H, et al. Advancements in all-ceramics for dental restorations and their effect on the wear of opposing dentition. Eur J Dent. 2016;10(4):583–8.PubMedPubMedCentralCrossRef Rashid H, et al. Advancements in all-ceramics for dental restorations and their effect on the wear of opposing dentition. Eur J Dent. 2016;10(4):583–8.PubMedPubMedCentralCrossRef
52.
go back to reference Ioannidis A, Bindl A. Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: up-to ten-year results. J Dent. 2016;47:80–5.PubMedCrossRef Ioannidis A, Bindl A. Clinical prospective evaluation of zirconia-based three-unit posterior fixed dental prostheses: up-to ten-year results. J Dent. 2016;47:80–5.PubMedCrossRef
53.
go back to reference Gou M, et al. Antagonist enamel wear of tooth-supported monolithic zirconia posterior crowns in vivo: a systematic review. J Prosthet Dent. 2019;121(4):598–603.PubMedCrossRef Gou M, et al. Antagonist enamel wear of tooth-supported monolithic zirconia posterior crowns in vivo: a systematic review. J Prosthet Dent. 2019;121(4):598–603.PubMedCrossRef
54.
go back to reference Stober T, et al. Clinical assessment of enamel wear caused by monolithic zirconia crowns. J Oral Rehabil. 2016;43(8):621–9.PubMedCrossRef Stober T, et al. Clinical assessment of enamel wear caused by monolithic zirconia crowns. J Oral Rehabil. 2016;43(8):621–9.PubMedCrossRef
55.
go back to reference Hartkamp O, Lohbauer U, Reich S. Antagonist wear by polished zirconia crowns. Int J Comput Dent. 2017;20(3):263–74.PubMed Hartkamp O, Lohbauer U, Reich S. Antagonist wear by polished zirconia crowns. Int J Comput Dent. 2017;20(3):263–74.PubMed
57.
go back to reference Söderholm KJ, et al. Clinical wear performance of eight experimental dental composites over three years determined by two measuring methods. Eur J Oral Sci. 2001;109(4):273–81.PubMedCrossRef Söderholm KJ, et al. Clinical wear performance of eight experimental dental composites over three years determined by two measuring methods. Eur J Oral Sci. 2001;109(4):273–81.PubMedCrossRef
58.
go back to reference Stawarczyk B, et al. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand. 2013;71(1):102–12.PubMedCrossRef Stawarczyk B, et al. Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonists. Acta Odontol Scand. 2013;71(1):102–12.PubMedCrossRef
59.
go back to reference Heintze SD. How to qualify and validate wear simulation devices and methods. Dent Mater. 2006;22(8):712–34.PubMedCrossRef Heintze SD. How to qualify and validate wear simulation devices and methods. Dent Mater. 2006;22(8):712–34.PubMedCrossRef
60.
go back to reference Preis V, et al. Wear performance of substructure ceramics and veneering porcelains. Dent Mater. 2011;27(8):796–804.PubMedCrossRef Preis V, et al. Wear performance of substructure ceramics and veneering porcelains. Dent Mater. 2011;27(8):796–804.PubMedCrossRef
61.
go back to reference Ohlmann B, et al. Wear of posterior metal-free polymer crowns after 2 years. J Oral Rehabil. 2008;35(10):782–8.PubMedCrossRef Ohlmann B, et al. Wear of posterior metal-free polymer crowns after 2 years. J Oral Rehabil. 2008;35(10):782–8.PubMedCrossRef
62.
go back to reference Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17(7):1759–64.PubMedCrossRef Seelbach P, Brueckel C, Wöstmann B. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig. 2013;17(7):1759–64.PubMedCrossRef
63.
go back to reference Millstein PL. Determining the accuracy of gypsum casts made from type IV dental stone. J Oral Rehabil. 1992;19(3):239–43.PubMedCrossRef Millstein PL. Determining the accuracy of gypsum casts made from type IV dental stone. J Oral Rehabil. 1992;19(3):239–43.PubMedCrossRef
64.
go back to reference Thongthammachat S, et al. Dimensional accuracy of dental casts: influence of tray material, impression material, and time. J Prosthodont. 2002;11(2):98–108.PubMedCrossRef Thongthammachat S, et al. Dimensional accuracy of dental casts: influence of tray material, impression material, and time. J Prosthodont. 2002;11(2):98–108.PubMedCrossRef
Metadata
Title
Wear of feldspathic-ceramic-veneered zirconia posterior FPDs after 10 years
Authors
Ragai-Edward Matta
Constantin Motel
Elena Kirchner
Simon Paul Stelzer
Werner Adler
Manfred Wichmann
Lara Berger
Publication date
01-12-2020
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2020
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-020-01336-8

Other articles of this Issue 1/2020

BMC Oral Health 1/2020 Go to the issue