Skip to main content
Top
Published in: BMC Oral Health 1/2015

Open Access 01-12-2015 | Technical advance

A new digital tool for radiographic bone level measurements in longitudinal studies

Authors: Hans R Preus, Gerald Ruiner Torgersen, Odd Carsten Koldsland, Bjørn Frode Hansen, Anne Merete Aass, Tore Arne Larheim, Leiv Sandvik

Published in: BMC Oral Health | Issue 1/2015

Login to get access

Abstract

Background

The reproducibility of measurements on radiographs is influenced by the techniques by which the images as well as the measurements are obtained. Thus, bias resulting from errors in the image and/or image examinations at two points in time may result in wrongful registrations of true biological or pathological changes. The aim of the present study was to propose and evaluate an indirect radiological examination technique, by which bias, when measuring radiographic bone level, could be substantially reduced as compared to the technique using direct mm measurements.

Methods

A plugin to ImageJ was designed to reduce bias when measuring bone loss on radiographic images. In human dry mandibles, radiographic images of 20 teeth were obtained parallel with the tooth axis (alpha = 0) and at an angle of 30° deviation. The direct technique of measuring radiographic bone level (RBL) and the indirect, length-adjusted RBL were registered by four researchers in a double blinded fashion.

Results

When mean RBL measured at 0° angle was 7.0 mm, the corresponding mean RBL measured at 30° angle was 7.8 mm, signifying an 11.4 % increase (p = 0.032), whereas the mean length-adjusted RBL increased by 0.6 % (p = 0.9).

Conclusions

This study showed that the use of the original, direct technique (ImageJ) resulted in markedly biased radiographic bone level at 30° angle, while the proposed indirect length-adjusted technique (ImageJ plugin) did not.
Literature
1.
go back to reference Haffajee AD, Socransky SS, Goodson JM. Periodontal disease activity. J Periodont Res. 1982;17:521–2.CrossRefPubMed Haffajee AD, Socransky SS, Goodson JM. Periodontal disease activity. J Periodont Res. 1982;17:521–2.CrossRefPubMed
2.
go back to reference Lindhe J, Haffajee AD, Socransky SS. Progression of periodontal disease in adult subjects in the absence of periodontal therapy. J Clin Periodontol. 1983;10:433–42.CrossRefPubMed Lindhe J, Haffajee AD, Socransky SS. Progression of periodontal disease in adult subjects in the absence of periodontal therapy. J Clin Periodontol. 1983;10:433–42.CrossRefPubMed
3.
go back to reference Papapanaou PN, Lindhe J. Epidemiology of periodontal diseases. In: Lindhe J, Lang NP, Karring T, editors. Clinical Periodontology and Implant Dentistry, vol. I. Fifthth ed. Oxford: Blackwell Munksgaard; 2008. p. 130–79. Papapanaou PN, Lindhe J. Epidemiology of periodontal diseases. In: Lindhe J, Lang NP, Karring T, editors. Clinical Periodontology and Implant Dentistry, vol. I. Fifthth ed. Oxford: Blackwell Munksgaard; 2008. p. 130–79.
4.
go back to reference Salvi GE, Lindhe J, Lang NP. Examination of patients with periodontal disease. In: Lindhe J, Lang NP, Karring T, editors. Clinical Periodontology and Implant Dentistry, vol. I. Fifthth ed. Oxford: Blackwell Munksgaard; 2008. p. 573–86. Salvi GE, Lindhe J, Lang NP. Examination of patients with periodontal disease. In: Lindhe J, Lang NP, Karring T, editors. Clinical Periodontology and Implant Dentistry, vol. I. Fifthth ed. Oxford: Blackwell Munksgaard; 2008. p. 573–86.
5.
go back to reference Larsen C, Barendregt DS, Slot DE, Van Der Velden U, Van Der Weijden F. Probing pressure, a highly undervalued unit of measure in periodontal probing: a systematic review on its effect on probing pocket depth. J Clin Periodontol. 2009;36:315–22.CrossRefPubMed Larsen C, Barendregt DS, Slot DE, Van Der Velden U, Van Der Weijden F. Probing pressure, a highly undervalued unit of measure in periodontal probing: a systematic review on its effect on probing pocket depth. J Clin Periodontol. 2009;36:315–22.CrossRefPubMed
6.
go back to reference Goodson JM, Tanner AC, Haffajee AD, Sornberger GC, Socransky SS. Patterns of progression and regression of advanced destructive periodontal disease. J Clin Periodontol. 1982;9:472–81.CrossRefPubMed Goodson JM, Tanner AC, Haffajee AD, Sornberger GC, Socransky SS. Patterns of progression and regression of advanced destructive periodontal disease. J Clin Periodontol. 1982;9:472–81.CrossRefPubMed
7.
go back to reference Albandar JM, Abbas DK, Waerhaug M, Gjermo P. Comparison between standardized periapical and bitewing radiographs in assessing alveolar bone loss. Com Dent Oral Epidemiol. 1985;13:222–5.CrossRef Albandar JM, Abbas DK, Waerhaug M, Gjermo P. Comparison between standardized periapical and bitewing radiographs in assessing alveolar bone loss. Com Dent Oral Epidemiol. 1985;13:222–5.CrossRef
8.
go back to reference Albander JM. Validity and reliability of alveolar bone level measurements made on dry skulls. J Clin Periodontol. 1989;16:575–9.CrossRef Albander JM. Validity and reliability of alveolar bone level measurements made on dry skulls. J Clin Periodontol. 1989;16:575–9.CrossRef
9.
go back to reference Updegrave WJ. The paralleling extension-cone technique in intraoral dental radiography. Oral Surg Oral Med Oral Pathol. 1951;4:1250–61.CrossRefPubMed Updegrave WJ. The paralleling extension-cone technique in intraoral dental radiography. Oral Surg Oral Med Oral Pathol. 1951;4:1250–61.CrossRefPubMed
10.
go back to reference Larheim TA, Eggen S. Measurements of alveolar bone height at tooth and implant abutments on intraoral radiographs. A comparison of reproducibility of Eggen technique utilized with and without a bite impression. J Clin Periodontol. 1982;9:184–92.CrossRefPubMed Larheim TA, Eggen S. Measurements of alveolar bone height at tooth and implant abutments on intraoral radiographs. A comparison of reproducibility of Eggen technique utilized with and without a bite impression. J Clin Periodontol. 1982;9:184–92.CrossRefPubMed
11.
go back to reference Albander JM, Abbas DK. Radiographic quantification of alveolar bone level changes. Comparison of 3 currently used methods. J Clin Periodontol. 1986;13:810–3.CrossRef Albander JM, Abbas DK. Radiographic quantification of alveolar bone level changes. Comparison of 3 currently used methods. J Clin Periodontol. 1986;13:810–3.CrossRef
12.
go back to reference Van Aken J. Optimum conditions for intraoral roentgenograms. Oral Surg. 1969;27:475–91.CrossRef Van Aken J. Optimum conditions for intraoral roentgenograms. Oral Surg. 1969;27:475–91.CrossRef
13.
go back to reference Schulze R, d’Hoedt B. Mathematical analysis of projection errors in “paralleling technique” with respect to implant geometry. Clin Oral Implants Res. 2001;12:364–71.CrossRefPubMed Schulze R, d’Hoedt B. Mathematical analysis of projection errors in “paralleling technique” with respect to implant geometry. Clin Oral Implants Res. 2001;12:364–71.CrossRefPubMed
14.
go back to reference Schulze R, d’Hoedt B. A method to calculate angular disparities between object and receptor in “paralleling technique”. Dentomaxillofac Radiol. 2002;31:32–8.CrossRefPubMed Schulze R, d’Hoedt B. A method to calculate angular disparities between object and receptor in “paralleling technique”. Dentomaxillofac Radiol. 2002;31:32–8.CrossRefPubMed
15.
go back to reference Roeder F, Brüllmann D, d’Hoedt B, Schulze R. Ex vivo radiographic tooth length measurements with the reference sphere method (RSM). Clin Oral Invest. 2010;14:645–51.CrossRef Roeder F, Brüllmann D, d’Hoedt B, Schulze R. Ex vivo radiographic tooth length measurements with the reference sphere method (RSM). Clin Oral Invest. 2010;14:645–51.CrossRef
16.
go back to reference Roeder F, von Rechenberg I, d’Hoedt B, Schulze R. Spatial relation between a rigid (digital) intraoral X-ray receptor and longitudinal axes of maxillary teeth. Clin Oral Invest. 2011;15:715–9.CrossRef Roeder F, von Rechenberg I, d’Hoedt B, Schulze R. Spatial relation between a rigid (digital) intraoral X-ray receptor and longitudinal axes of maxillary teeth. Clin Oral Invest. 2011;15:715–9.CrossRef
17.
go back to reference Eikholz P, Hausmann E. Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements. Eur J Oral Sci. 2000;108:70–3.CrossRef Eikholz P, Hausmann E. Accuracy of radiographic assessment of interproximal bone loss in intrabony defects using linear measurements. Eur J Oral Sci. 2000;108:70–3.CrossRef
18.
go back to reference Kim TS, Obst C, Zahaczek S, Geenen C. Detection of bone loss with different X-ray techniques in periodontal patients. J Periodontol. 2008;79:1141–9.CrossRefPubMed Kim TS, Obst C, Zahaczek S, Geenen C. Detection of bone loss with different X-ray techniques in periodontal patients. J Periodontol. 2008;79:1141–9.CrossRefPubMed
19.
go back to reference Page RC, Eke PI. Case definitions for use in population based surveillance of periodontitis. J Periodontol. 2007;78:1387–99.CrossRefPubMed Page RC, Eke PI. Case definitions for use in population based surveillance of periodontitis. J Periodontol. 2007;78:1387–99.CrossRefPubMed
20.
go back to reference Tonetti MS, Claffey N. Advances in the progression of periodontitis and proposal of definitions of a periodontitis case and disease progression for use in risk factor research. Group C consensus report of the 5th European workshop in periodontology. J Clin Periodontol. 2005;32 suppl 6:210–3.CrossRefPubMed Tonetti MS, Claffey N. Advances in the progression of periodontitis and proposal of definitions of a periodontitis case and disease progression for use in risk factor research. Group C consensus report of the 5th European workshop in periodontology. J Clin Periodontol. 2005;32 suppl 6:210–3.CrossRefPubMed
22.
go back to reference Shrout PE, Fleiss FL. Intra-class correlations: Uses in assessing rater reliability. Psychol Bull. 1979;86:420–8.CrossRefPubMed Shrout PE, Fleiss FL. Intra-class correlations: Uses in assessing rater reliability. Psychol Bull. 1979;86:420–8.CrossRefPubMed
23.
go back to reference Preus HR, Gunleiksrud T, Sandvik L, Gjermo P, Baelum V. A randomized, double blind clinical trial comparing four periodontitis teratment strategies. One-year clinical results. J Periodontol. 2013;84:1075–86.CrossRefPubMed Preus HR, Gunleiksrud T, Sandvik L, Gjermo P, Baelum V. A randomized, double blind clinical trial comparing four periodontitis teratment strategies. One-year clinical results. J Periodontol. 2013;84:1075–86.CrossRefPubMed
24.
go back to reference Schei O, Waerhaug J, Løvdal A, Arno A. Alveolar bone loss as related to oral hygiene and age. J Periodontol. 1959;30:7–16.CrossRef Schei O, Waerhaug J, Løvdal A, Arno A. Alveolar bone loss as related to oral hygiene and age. J Periodontol. 1959;30:7–16.CrossRef
25.
go back to reference Bassiouny MA, Grant AA. The accuracy of the Schei Ruler: A laboratory investigation. J Periodontol. 1975;46:748–52.CrossRefPubMed Bassiouny MA, Grant AA. The accuracy of the Schei Ruler: A laboratory investigation. J Periodontol. 1975;46:748–52.CrossRefPubMed
26.
go back to reference Björn H, Halling A, Thyberg H. Radiographic assessment of marginal bone loss. Odont Rev. 1969;20:165–79. Björn H, Halling A, Thyberg H. Radiographic assessment of marginal bone loss. Odont Rev. 1969;20:165–79.
27.
go back to reference Björn A-L, Björn H, Halling A. An abbreviated index for periodontal bone height. Odont Rev. 1975;26:225–30. Björn A-L, Björn H, Halling A. An abbreviated index for periodontal bone height. Odont Rev. 1975;26:225–30.
28.
go back to reference Benn DK. A review of the reliability of radiographic measurements in estimating alveolar bone changes. J Clin Periodontol. 1990;17:14–21.CrossRefPubMed Benn DK. A review of the reliability of radiographic measurements in estimating alveolar bone changes. J Clin Periodontol. 1990;17:14–21.CrossRefPubMed
29.
go back to reference Dubrez B, Jacot-Descombes S, Cimasoni G. Reliability of a paralleling instrument for dental radiographs. Oral Surg Oral Med Oral Pthol Oral Radiol Endod. 1995;80:358–64.CrossRef Dubrez B, Jacot-Descombes S, Cimasoni G. Reliability of a paralleling instrument for dental radiographs. Oral Surg Oral Med Oral Pthol Oral Radiol Endod. 1995;80:358–64.CrossRef
30.
go back to reference Zappa U, Simona C, Graf H, van Aken J. In vivo determination of radiographic projection errors produced by a novel filmholder and an x-ray beam manipulator. J Periodontol. 1991;62:674–83.CrossRefPubMed Zappa U, Simona C, Graf H, van Aken J. In vivo determination of radiographic projection errors produced by a novel filmholder and an x-ray beam manipulator. J Periodontol. 1991;62:674–83.CrossRefPubMed
31.
go back to reference Wu JC, Huang JN, Zhao SF, Xu XJ, Zhang JC, Xia B, et al. Use of a simple intraoral instrument to standardize film alignment and improve image reproducibility. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005;100:99–104.CrossRefPubMed Wu JC, Huang JN, Zhao SF, Xu XJ, Zhang JC, Xia B, et al. Use of a simple intraoral instrument to standardize film alignment and improve image reproducibility. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 2005;100:99–104.CrossRefPubMed
32.
go back to reference Schulze R, Bruellmann DD, Roeder F, d’Hoedt B. Determination of projection geometry from quantitative assessment of the distortion of spherical references in single-view projection radiography. Med Phys. 2004;31:2849–54.CrossRefPubMed Schulze R, Bruellmann DD, Roeder F, d’Hoedt B. Determination of projection geometry from quantitative assessment of the distortion of spherical references in single-view projection radiography. Med Phys. 2004;31:2849–54.CrossRefPubMed
33.
Metadata
Title
A new digital tool for radiographic bone level measurements in longitudinal studies
Authors
Hans R Preus
Gerald Ruiner Torgersen
Odd Carsten Koldsland
Bjørn Frode Hansen
Anne Merete Aass
Tore Arne Larheim
Leiv Sandvik
Publication date
01-12-2015
Publisher
BioMed Central
Published in
BMC Oral Health / Issue 1/2015
Electronic ISSN: 1472-6831
DOI
https://doi.org/10.1186/s12903-015-0092-9

Other articles of this Issue 1/2015

BMC Oral Health 1/2015 Go to the issue