Background

The benefit of Self-monitoring of Blood Glucose (SMBG) in people with non-insulin treated type 2 diabetes remains unclear with inconsistent evidence from randomised controlled trials fuelling the continued debate. Lack of a consistent finding has been attributed to variations in study population and design, including the SMBG intervention. There is a growing consensus that structured SMBG, whereby the person with diabetes and health care provider are educated to detect patterns of glycaemic abnormality and take appropriate action according to the blood glucose profiles, can prove beneficial in terms of lowering HbA1c and improving overall well-being. Despite this, many national health agencies continue to issue guidelines restricting the use of SMBG in non-insulin treated type 2 diabetes.

Methods

The SMBG Study is a 12 month, multi-centre, randomised controlled trial in people with type 2 diabetes not on insulin therapy who have poor glycaemic control (HbA1c ≥58 mmol/mol / 7.5%). The participants will be randomised into three comparative groups: Group 1 will act as a control group and receive their usual diabetes care; Group 2 will undertake structured SMBG with clinical review every 3 months; Group 3 will undertake structured SMBG with additional monthly telecare support from a trained study nurse. A total of 450 participants will be recruited from 16 primary and secondary care sites across Wales and England. The primary outcome measure will be HbA1c at 12 months with secondary measures to include weight, BMI, total cholesterol and HbA1c levels at 3, 6, 9 and 12 months. Participant well-being and attitude towards SMBG will be monitored throughout the course of the study. Recruitment began in December 2012 with the last participant visit due in September 2016.

Discussion

This study will attempt to answer the question of whether structured SMBG provides any benefits to people with poorly controlled type 2 diabetes who are not being treated with insulin. The data will also clarify whether the telecare support provides additional value. The overall acceptability of SMBG as a tool for self-management will be assessed.

Trial registration

UKCRN 12038 (Registered March 2012).
ISRCTN21390608 (Retrospectively registered 15th May 2014).
Literature
2.
go back to reference National Collaborating Centre for Chronic Conditions. Type 2 Diabetes: National clinical guideline for management in primary and secondary care (update). Royal College of Physicians London 2009. National Collaborating Centre for Chronic Conditions. Type 2 Diabetes: National clinical guideline for management in primary and secondary care (update). Royal College of Physicians London 2009. 
3.
go back to reference Farmer AJ, Perera R, Ward A, et al. Meta-analysis of individual patient data in randomised trials of self-monitoring of blood glucose in people with non-insulin treated type 2 diabetes. BMJ. 2012;344:e486.CrossRefPubMed Farmer AJ, Perera R, Ward A, et al. Meta-analysis of individual patient data in randomised trials of self-monitoring of blood glucose in people with non-insulin treated type 2 diabetes. BMJ. 2012;344:e486.CrossRefPubMed
4.
go back to reference McAndrew L, Schneider SH, Burns E, et al. Does patient blood glucose monitoring improve diabetic control?: A systematic review of the literature. Diabetes Educ. 2007;33:991–1011.CrossRefPubMed McAndrew L, Schneider SH, Burns E, et al. Does patient blood glucose monitoring improve diabetic control?: A systematic review of the literature. Diabetes Educ. 2007;33:991–1011.CrossRefPubMed
5.
go back to reference Farmer A, Wade A, Goyder E, et al. Impact of self-monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial. BMJ. 2007;335:132.CrossRefPubMedPubMedCentral Farmer A, Wade A, Goyder E, et al. Impact of self-monitoring of blood glucose in the management of patients with non-insulin treated diabetes: open parallel group randomised trial. BMJ. 2007;335:132.CrossRefPubMedPubMedCentral
6.
go back to reference Kempf K, Neukirchen W, Martin S, et al. Self-monitoring of blood glucose in type 2 diabetes; a new look at published trials. Diabetologia. 2008;51:686–8.CrossRefPubMed Kempf K, Neukirchen W, Martin S, et al. Self-monitoring of blood glucose in type 2 diabetes; a new look at published trials. Diabetologia. 2008;51:686–8.CrossRefPubMed
7.
go back to reference O’Kane MJ, Bunting B, Copeland M, et al. Efficacy of self-monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): randomised controlled trial. BMJ. 2008;336:1174.CrossRefPubMedPubMedCentral O’Kane MJ, Bunting B, Copeland M, et al. Efficacy of self-monitoring of blood glucose in patients with newly diagnosed type 2 diabetes (ESMON study): randomised controlled trial. BMJ. 2008;336:1174.CrossRefPubMedPubMedCentral
8.
go back to reference Clar C, Barnard K, Cummins E, Aberdeen Health Technology Assessment Group, et al. Self-monitoring of blood glucose in type 2 diabetes: systematic review. Health Technol Assess. 2010;14:1–140.CrossRef Clar C, Barnard K, Cummins E, Aberdeen Health Technology Assessment Group, et al. Self-monitoring of blood glucose in type 2 diabetes: systematic review. Health Technol Assess. 2010;14:1–140.CrossRef
9.
go back to reference Polonsky WH, Fisher L, Schikman CH, et al. Structured self-monitoring of blood glucose significantly reduces A1C levels in poorly controlled, noninsulin-treated type 2 diabetes: results from the Structured Testing Program study. Diabetes Care. 2011;34:262–7.CrossRefPubMedPubMedCentral Polonsky WH, Fisher L, Schikman CH, et al. Structured self-monitoring of blood glucose significantly reduces A1C levels in poorly controlled, noninsulin-treated type 2 diabetes: results from the Structured Testing Program study. Diabetes Care. 2011;34:262–7.CrossRefPubMedPubMedCentral
10.
go back to reference Malanda UL, Welschen LMC, Riphagen II, et al. Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin. Cochrane Database of Systematic Reviews 2012, Issue 1. Art. No.: CD005060. DOI: 10.1002/14651858.CD005060.pub3 Malanda UL, Welschen LMC, Riphagen II, et al. Self-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin. Cochrane Database of Systematic Reviews 2012, Issue 1. Art. No.: CD005060. DOI: 10.​1002/​14651858.​CD005060.​pub3
11.
go back to reference Bosi E, Scavini M, Ceriello A, et al. Intensive structured self-monitoring of blood glucose and glycemic control in noninsulin-treated type 2 diabetes: the PRISMA randomized trial. Diabetes Care. 2013;36(10):2887–94.CrossRefPubMedPubMedCentral Bosi E, Scavini M, Ceriello A, et al. Intensive structured self-monitoring of blood glucose and glycemic control in noninsulin-treated type 2 diabetes: the PRISMA randomized trial. Diabetes Care. 2013;36(10):2887–94.CrossRefPubMedPubMedCentral
12.
go back to reference Benhalima K, Mathieu C. The role of blood glucose monitoring in non-insulin treated type 2 diabetes: What is the evidence? Prim Care Diabetes. 2012;6:179–85.CrossRefPubMed Benhalima K, Mathieu C. The role of blood glucose monitoring in non-insulin treated type 2 diabetes: What is the evidence? Prim Care Diabetes. 2012;6:179–85.CrossRefPubMed
14.
go back to reference Speight J, Browne JL, Furler JS. Testing times! Choosing Wisely when it comes to monitoring type 2 diabetes. Med J Aust. 2015;203(9):354–6.CrossRefPubMed Speight J, Browne JL, Furler JS. Testing times! Choosing Wisely when it comes to monitoring type 2 diabetes. Med J Aust. 2015;203(9):354–6.CrossRefPubMed
15.
go back to reference Franciosi M, Pellegrini F, De Berardis G, et al. The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies. Diabetes Care. 2001;24:1870–7.CrossRefPubMed Franciosi M, Pellegrini F, De Berardis G, et al. The impact of blood glucose self-monitoring on metabolic control and quality of life in type 2 diabetic patients: an urgent need for better educational strategies. Diabetes Care. 2001;24:1870–7.CrossRefPubMed
18.
go back to reference Belsey JD, Pittard JB, Rao S, et al. Self blood glucose monitoring in type 2 diabetes. A financial impact analysis based on UK primary care. Int J Clin Pract. 2009;63:439–48.CrossRefPubMed Belsey JD, Pittard JB, Rao S, et al. Self blood glucose monitoring in type 2 diabetes. A financial impact analysis based on UK primary care. Int J Clin Pract. 2009;63:439–48.CrossRefPubMed
19.
go back to reference Parkin CG, Price D. Randomized studies are needed to assess the true role of self-monitoring of blood glucose in noninsulin-treated type 2 diabetes. J Diabetes Sci Technol. 2007;1:595–602.CrossRefPubMedPubMedCentral Parkin CG, Price D. Randomized studies are needed to assess the true role of self-monitoring of blood glucose in noninsulin-treated type 2 diabetes. J Diabetes Sci Technol. 2007;1:595–602.CrossRefPubMedPubMedCentral
20.
go back to reference Klonoff DC. New evidence demonstrates that self-monitoring of blood glucose does not improve outcomes in type 2 diabetes – when this practice is not applied properly. J Diabetes Sci Technol. 2009;2(3):342–8.CrossRef Klonoff DC. New evidence demonstrates that self-monitoring of blood glucose does not improve outcomes in type 2 diabetes – when this practice is not applied properly. J Diabetes Sci Technol. 2009;2(3):342–8.CrossRef
21.
go back to reference Malanda UL, Bot SD, Nijpels G. Self-monitoring of blood glucose in noninsulin-using type 2 diabetic patients. Diabetes Care. 2013;36:176–8.CrossRefPubMed Malanda UL, Bot SD, Nijpels G. Self-monitoring of blood glucose in noninsulin-using type 2 diabetic patients. Diabetes Care. 2013;36:176–8.CrossRefPubMed
22.
go back to reference Polonsky WH, Fisher L. Self-monitoring of blood glucose in noninsulin-using type 2 diabetic patients. Diabetes Care. 2013;36:179–82.CrossRefPubMed Polonsky WH, Fisher L. Self-monitoring of blood glucose in noninsulin-using type 2 diabetic patients. Diabetes Care. 2013;36:179–82.CrossRefPubMed
26.
go back to reference Speight J, Bradley C. The ADKnowl: identifying knowledge deficits in diabetes care. Diabet Med. 2008;18(8):626–39.CrossRef Speight J, Bradley C. The ADKnowl: identifying knowledge deficits in diabetes care. Diabet Med. 2008;18(8):626–39.CrossRef
27.
go back to reference The EuroQol Group. EuroQol - A new facility for the measurement of health related quality of life. Health Policy. 1990;16:199–208.CrossRef The EuroQol Group. EuroQol - A new facility for the measurement of health related quality of life. Health Policy. 1990;16:199–208.CrossRef
28.
go back to reference Bradley C, Todd C, Gorton T, et al. The development of an individualised questionnaire measure of perceived impact of diabetes on quality of life: the ADDQoL. Qual Life Res. 1999;8:79–91.CrossRefPubMed Bradley C, Todd C, Gorton T, et al. The development of an individualised questionnaire measure of perceived impact of diabetes on quality of life: the ADDQoL. Qual Life Res. 1999;8:79–91.CrossRefPubMed
29.
go back to reference Koneke K, Spitzer RL, Williams JB. The PHQ-9: validity of a brief depression severity measure. J Gen Intern Med. 2001;16(9):606–13.CrossRef Koneke K, Spitzer RL, Williams JB. The PHQ-9: validity of a brief depression severity measure. J Gen Intern Med. 2001;16(9):606–13.CrossRef
30.
go back to reference Inzucchi SE, Bergenstal RM, Buse JB, et al. Management of hyperglycaemia in type 2 diabetes: a patient-centred approach. Position statement of the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetologia. 2012;55:1577–96.CrossRefPubMed Inzucchi SE, Bergenstal RM, Buse JB, et al. Management of hyperglycaemia in type 2 diabetes: a patient-centred approach. Position statement of the American Diabetes Association (ADA) and the European Association for the Study of Diabetes (EASD). Diabetologia. 2012;55:1577–96.CrossRefPubMed
31.
go back to reference American Diabetes Association. Tests of glycemia in diabetes; Position Statement. Diabetes Care 2004; 27 (Suppl 1): S91 - S93. American Diabetes Association. Tests of glycemia in diabetes; Position Statement. Diabetes Care 2004; 27 (Suppl 1): S91 - S93.
32.
go back to reference Luzio S, Piehlmeier W, Tovar C, et al. Results of the pilot study of DIADEM - A comprehensive disease management programme for type 2 diabetes. Diabetes Res Clin Pract. 2007;76(3):410–7. Luzio S, Piehlmeier W, Tovar C, et al. Results of the pilot study of DIADEM - A comprehensive disease management programme for type 2 diabetes. Diabetes Res Clin Pract. 2007;76(3):410–7.
Metadata
Title
Self-monitoring of Blood Glucose in Non-Insulin Treated Type 2 Diabetes (The SMBG Study): study protocol for a randomised controlled trial
Authors
Sharon Parsons
Stephen Luzio
Stephen Bain
John Harvey
Jillian McKenna
Atir Khan
Sam Rice
Alan Watkins
David R. Owens
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Endocrine Disorders / Issue 1/2017
Electronic ISSN: 1472-6823
DOI
https://doi.org/10.1186/s12902-017-0154-x

Other articles of this Issue 1/2017

BMC Endocrine Disorders 1/2017 Go to the issue