Abstract

Background

Optical Coherence Tomography (OCT) imaging is being increasingly used in clinical practice for the monitoring of papilloedema. The aim is to characterise the extent and location of the Retinal Nerve Fibre Layer (RNFL) Thickness automated segmentation error (SegE) by manual refinement, in a cohort of Idiopathic Intracranial Hypertension (IIH) patients with papilloedema and compare this to controls.

Methods

Baseline Spectral Domain OCT (SDOCT) scans from patients with IIH, and controls with no retinal or optic nerve pathology, were examined. The internal limiting membrane and RNFL thickness of the most severely affected eye was examined for SegE and re-segmented. Using ImageJ, the total area of the RNFL thickness was calculated pre and post re-segmentation and the percentage change was determined. The distribution of RNFL thickness error was qualitatively assessed.

Results

Significantly greater SegE (p = 0.009) was present in RNFL thickness total area, assessed using ImageJ, in IIH patients (n = 46, 5% ± 0–58%) compared to controls (n = 14, 1% ± 0–6%). This was particularly evident in moderate to severe optic disc swelling (n = 23, 10% ± 0–58%, p < 0.001). RNFL thickness was unable to be quantified using SDOCT in patients with severe papilloedema.

Conclusions

SegE remain a concern for clinicians using SDOCT to monitor papilloedema in IIH, particularly in the assessment of eyes with moderate to severe oedema. Systematic assessment and manual refinement of SegE is therefore important to ensure the accuracy in longitudinal monitoring of patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Sinclair AJ, Burdon MA, Nightingale PG, et al. Rating papilloedema: an evaluation of the Frisén classification in idiopathic intracranial hypertension. J Neurol. 2012;259:1406–12.CrossRefPubMed Sinclair AJ, Burdon MA, Nightingale PG, et al. Rating papilloedema: an evaluation of the Frisén classification in idiopathic intracranial hypertension. J Neurol. 2012;259:1406–12.CrossRefPubMed
2.
go back to reference Optical Coherence Tomography Substudy Committee, NORDIC Idiopathic Intracranial Hypertension Study Group. Papilledema outcomes from the optical coherence tomography substudy of the idiopathic intracranial hypertension treatment trial. Ophthalmology. 2015;122:1939-45.e2. Optical Coherence Tomography Substudy Committee, NORDIC Idiopathic Intracranial Hypertension Study Group. Papilledema outcomes from the optical coherence tomography substudy of the idiopathic intracranial hypertension treatment trial. Ophthalmology. 2015;122:1939-45.e2.
3.
go back to reference Skau M, Milea D, Sander B, Wegener M, Jensen R. OCT for optic disc evaluation in idiopathic intracranial hypertension. Graefes Arch Clin Exp Ophthalmol. 2011;249:723–30.CrossRefPubMed Skau M, Milea D, Sander B, Wegener M, Jensen R. OCT for optic disc evaluation in idiopathic intracranial hypertension. Graefes Arch Clin Exp Ophthalmol. 2011;249:723–30.CrossRefPubMed
4.
go back to reference Kaufhold F, Kadas EM, Schmidt C, et al. Optic nerve head quantification in idiopathic intracranial hypertension by spectral domain OCT. PLoS One. 2012;7:e36965.CrossRefPubMedPubMedCentral Kaufhold F, Kadas EM, Schmidt C, et al. Optic nerve head quantification in idiopathic intracranial hypertension by spectral domain OCT. PLoS One. 2012;7:e36965.CrossRefPubMedPubMedCentral
6.
go back to reference Mansberger SL, Menda SA, Fortune BA, Gardiner SK, Demirel S. Automated segmentation errors when using optical coherence tomography to measure retinal nerve fiber layer thickness in glaucoma. Am J Ophthalmol. 2017;174:1–8.CrossRefPubMed Mansberger SL, Menda SA, Fortune BA, Gardiner SK, Demirel S. Automated segmentation errors when using optical coherence tomography to measure retinal nerve fiber layer thickness in glaucoma. Am J Ophthalmol. 2017;174:1–8.CrossRefPubMed
7.
go back to reference Karam EZ, Hedges TR. Optical coherence tomography of the retinal nerve fibre layer in mild papilloedema and pseudopapilloedema. Br J Ophthalmol. 2005;89:294–8.CrossRefPubMedPubMedCentral Karam EZ, Hedges TR. Optical coherence tomography of the retinal nerve fibre layer in mild papilloedema and pseudopapilloedema. Br J Ophthalmol. 2005;89:294–8.CrossRefPubMedPubMedCentral
8.
go back to reference Scott CJ, Kardon RH, Lee AG, Frisén L, Wall M. Diagnosis and grading of papilledema in patients with raised intracranial pressure using optical coherence tomography vs clinical expert assessment using a clinical staging scale. Arch Ophthalmol. 2010;128:705–11.CrossRefPubMed Scott CJ, Kardon RH, Lee AG, Frisén L, Wall M. Diagnosis and grading of papilledema in patients with raised intracranial pressure using optical coherence tomography vs clinical expert assessment using a clinical staging scale. Arch Ophthalmol. 2010;128:705–11.CrossRefPubMed
9.
go back to reference Chen JJ, Kardon RH. Avoiding clinical misinterpretation and artifacts of optical coherence tomography analysis of the optic nerve, retinal nerve fiber layer, and ganglion cell layer. J Neuroophthalmol. 2016;36:417–38.CrossRefPubMedPubMedCentral Chen JJ, Kardon RH. Avoiding clinical misinterpretation and artifacts of optical coherence tomography analysis of the optic nerve, retinal nerve fiber layer, and ganglion cell layer. J Neuroophthalmol. 2016;36:417–38.CrossRefPubMedPubMedCentral
10.
go back to reference Friedman DI, Liu GT, Digre KB. Revised diagnostic criteria for the pseudotumour cerebri syndrome in adults and children. Neurology. 2013;81:1159–65.CrossRefPubMed Friedman DI, Liu GT, Digre KB. Revised diagnostic criteria for the pseudotumour cerebri syndrome in adults and children. Neurology. 2013;81:1159–65.CrossRefPubMed
12.
go back to reference Giani A, Cigada M, Esmaili DD, et al. Artifacts in automatic retinal segmentation using different optical coherence tomography instruments. Retina. 2010;30:607–16.CrossRefPubMed Giani A, Cigada M, Esmaili DD, et al. Artifacts in automatic retinal segmentation using different optical coherence tomography instruments. Retina. 2010;30:607–16.CrossRefPubMed
13.
go back to reference OCT Sub-Study Committee for the NORDIC Idiopathic Intracranial Hypertension Study Group. Baseline OCT measurements in the idiopathic intracranial hypertension treatment trial, part I: quality control, comparisons, and variability. Invest Ophthalmol Vis Sci. 2014;55:8180–8.CrossRefPubMedCentral OCT Sub-Study Committee for the NORDIC Idiopathic Intracranial Hypertension Study Group. Baseline OCT measurements in the idiopathic intracranial hypertension treatment trial, part I: quality control, comparisons, and variability. Invest Ophthalmol Vis Sci. 2014;55:8180–8.CrossRefPubMedCentral
14.
go back to reference Spaide RF. Visualization of the posterior vitreous with dynamic focusing and windowed averaging swept source optical coherence tomography. Am J Ophthalmol. 2014;158:1267–74.CrossRefPubMed Spaide RF. Visualization of the posterior vitreous with dynamic focusing and windowed averaging swept source optical coherence tomography. Am J Ophthalmol. 2014;158:1267–74.CrossRefPubMed
15.
go back to reference Asrani S, Essaid L, Alder BD, Santiago-Turla C. Artifacts in spectral-domain optical coherence tomography measurements in glaucoma. JAMA Ophthalmol. 2014;132:396–402.CrossRefPubMed Asrani S, Essaid L, Alder BD, Santiago-Turla C. Artifacts in spectral-domain optical coherence tomography measurements in glaucoma. JAMA Ophthalmol. 2014;132:396–402.CrossRefPubMed
16.
go back to reference Cheung CY, Leung CK, Lin D, et al. Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology. 2008;115:1347–51.CrossRefPubMed Cheung CY, Leung CK, Lin D, et al. Relationship between retinal nerve fiber layer measurement and signal strength in optical coherence tomography. Ophthalmology. 2008;115:1347–51.CrossRefPubMed
17.
go back to reference Wu Z, Vazeen M, Varma R, et al. Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography. Ophthalmology. 2007;114:1505–12.CrossRefPubMed Wu Z, Vazeen M, Varma R, et al. Factors associated with variability in retinal nerve fiber layer thickness measurements obtained by optical coherence tomography. Ophthalmology. 2007;114:1505–12.CrossRefPubMed
18.
go back to reference Liu Y, Simavli H, Que C, et al. Patient characteristics associated with artifacts in Spectralis optical coherence tomography imaging of the retinal nerve fiber layer in glaucoma. Am J Ophthalmol. 2015;159:565–76.CrossRefPubMed Liu Y, Simavli H, Que C, et al. Patient characteristics associated with artifacts in Spectralis optical coherence tomography imaging of the retinal nerve fiber layer in glaucoma. Am J Ophthalmol. 2015;159:565–76.CrossRefPubMed
19.
20.
go back to reference Giani A, Cigada M, Choudhry N, et al. Reproducibility of retinal thickness measurements on normal and pathologic eyes by different optical coherence tomography instruments. Am J Ophthalmol. 2010;150(6):815–24.CrossRefPubMed Giani A, Cigada M, Choudhry N, et al. Reproducibility of retinal thickness measurements on normal and pathologic eyes by different optical coherence tomography instruments. Am J Ophthalmol. 2010;150(6):815–24.CrossRefPubMed
21.
go back to reference Pircher M, Hitzenberger CK, Schmidt-Erfurth U. Polarization sensitive optical coherence tomography in the human eye. Prog Retin Eye Res. 2011;30(6):431–51.CrossRefPubMedPubMedCentral Pircher M, Hitzenberger CK, Schmidt-Erfurth U. Polarization sensitive optical coherence tomography in the human eye. Prog Retin Eye Res. 2011;30(6):431–51.CrossRefPubMedPubMedCentral
Metadata
Title
Segmentation error in spectral domain optical coherence tomography measures of the retinal nerve fibre layer thickness in idiopathic intracranial hypertension
Authors
Anuriti Aojula
Susan P Mollan
John Horsburgh
Andreas Yiangou
Kiera A Markey
James L Mitchell
William J Scotton
Pearse A Keane
Alexandra J Sinclair
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Ophthalmology / Issue 1/2017
Electronic ISSN: 1471-2415
DOI
https://doi.org/10.1186/s12886-017-0652-7

Other articles of this Issue 1/2017

BMC Ophthalmology 1/2017 Go to the issue