Background

D-dimer was introduced in 2018 as an alternative biomarker for C-reactive protein (CRP) in the diagnostic of prosthetic joint infection (PJI) criteria of the Musculoskeletal Infection Society. We assessed the accuracy of plasma D-dimer for the diagnosis of early, delayed, and late PJI according to Infectious Diseases Society of America (IDSA) criteria, and whether persistently high levels of D-dimer in cases of aseptic loosening (AL) may be predictive of subsequent implant-related infection.

Methods

A prospective study of a consecutive series of 187 revision arthroplasties was performed at a single institution. Septic (n = 39) and aseptic revisions (n = 141) were classified based on IDSA criteria. Preoperative assessment of CRP, erythrocyte sedimentation rate (ESR) and D-dimer was performed. Receiver operating curves were used to determine maximum sensitivity and specificity of the biomarkers. The natural progress of D-dimer for AL cases was followed up either until the date of implant-related infection at any time during the first year or 1 year after revision in patients without failure. Clinical outcomes for those AL cases included infection-related failure that required a new surgery or need for antibiotic suppression.

Results

Preoperative D-dimer level was significantly higher in PJI cases than in AL cases (p = 0.000). The optimal threshold of D-dimer for the diagnosis of PJI was 1167 ng/mL. For overall diagnosis of PJI, C-reactive protein (CRP) achieved the highest sensitivity (84.6%), followed by erythrocyte sedimentation rate (ESR) and D-dimer (82% and 71.8%, respectively). Plasma D-dimer sensitivity was lower for all PJI types. When combinations of 2 tests were studied, the combined use of ESR and CRP achieved the best accuracy for all types of PJI (76.9%). 4.25% of AL cases had implant failure due to implant-related infection during the first year after the index revision arthroplasty, only the cases with early failure maintained high D-dimer levels.

Conclusions

Plasma D-dimer did not offer an improvement over the individual or combined diagnosis for any type of PJI according to IDSA criteria. Persistently raised levels of D-dimer after revision arthroplasty in AL cases might be used to effectively diagnose early postoperative infection.
Appendix
Available only for authorised users
Literature
1.
go back to reference Osmon DR, Berbari EF, Berendt AR, Lew D, Zimmerli W, Steckelberg JM, Rao N, Hanssen A, Wilson WR. Diagnosis and management of prosthetic joint infection: clinical practice guidelines by the Infectious Diseases Society of America. Clin Infect Dis. 2013;56(1):e1-25.CrossRef Osmon DR, Berbari EF, Berendt AR, Lew D, Zimmerli W, Steckelberg JM, Rao N, Hanssen A, Wilson WR. Diagnosis and management of prosthetic joint infection: clinical practice guidelines by the Infectious Diseases Society of America. Clin Infect Dis. 2013;56(1):e1-25.CrossRef
2.
go back to reference Parvizi J, Zmistowski B, Berbari EF, Bauer TW, Springer BD, DellaValle CJ, Garvin KL, Mont MA, Wongworawat MD, Zalavras CG. New definition for periprosthetic joint infection: from the workgroup of the Musculoskeletal infection Society. Clin Orthop Relat Res. 2011;469:2992e4. Parvizi J, Zmistowski B, Berbari EF, Bauer TW, Springer BD, DellaValle CJ, Garvin KL, Mont MA, Wongworawat MD, Zalavras CG. New definition for periprosthetic joint infection: from the workgroup of the Musculoskeletal infection Society. Clin Orthop Relat Res. 2011;469:2992e4.
3.
go back to reference Parvizi J, Gehrke T, Chen AF. Philadelphia 2013: international consensus meeting on periprosthetic joint infection. Bone Joint J. 2013;95-B(11):1450–2.CrossRef Parvizi J, Gehrke T, Chen AF. Philadelphia 2013: international consensus meeting on periprosthetic joint infection. Bone Joint J. 2013;95-B(11):1450–2.CrossRef
4.
go back to reference McNally M, Sousa R, Wouthuyzen-Bakker M, Chen AF, Soriano A, Vogely HC, Clauss M, Higuera CA, Trebše R. The EBJIS definition of periprosthetic joint infection: a practical guide for clinicians. Bone Joint J. 2021;103-B(1):18–25 (Published online 2021 Jan 1).CrossRef McNally M, Sousa R, Wouthuyzen-Bakker M, Chen AF, Soriano A, Vogely HC, Clauss M, Higuera CA, Trebše R. The EBJIS definition of periprosthetic joint infection: a practical guide for clinicians. Bone Joint J. 2021;103-B(1):18–25 (Published online 2021 Jan 1).CrossRef
5.
go back to reference Parvizi J, Tan TL, Goswami K, Higuera C, Della Valle C, Chen AF, Shohat N. The 2018 definition of periprosthetic hip and knee infection: an evidence-based and validated criteria. J Arthroplasty. 2018;33:1309e1314.e2.CrossRef Parvizi J, Tan TL, Goswami K, Higuera C, Della Valle C, Chen AF, Shohat N. The 2018 definition of periprosthetic hip and knee infection: an evidence-based and validated criteria. J Arthroplasty. 2018;33:1309e1314.e2.CrossRef
6.
go back to reference Shohat N, Bauer T, Buttaro M, Budhiparama N, Cashman J, Della Valle CJ, et al. Hip and Knee Section, What is the definition of a Periprosthetic Joint Infection (PJI) of the knee and the hip? Can the same criteria be used for both joints?: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty. 2019; 34(2):S325–S7. Shohat N, Bauer T, Buttaro M, Budhiparama N, Cashman J, Della Valle CJ, et al. Hip and Knee Section, What is the definition of a Periprosthetic Joint Infection (PJI) of the knee and the hip? Can the same criteria be used for both joints?: Proceedings of International Consensus on Orthopedic Infections. J Arthroplasty. 2019; 34(2):S325–S7.
7.
go back to reference Shahi A, Kheir MM, Tarabichi M, Hosseinzadeh HRS, Tan TL, Parvizi J. Serum D-dimer test is promising for the diagnosis of periprosthetic joint infection and timing of reimplantation. J Bone Joint Surg Am. 2017;99:1419–27.CrossRef Shahi A, Kheir MM, Tarabichi M, Hosseinzadeh HRS, Tan TL, Parvizi J. Serum D-dimer test is promising for the diagnosis of periprosthetic joint infection and timing of reimplantation. J Bone Joint Surg Am. 2017;99:1419–27.CrossRef
8.
go back to reference Huang J, Zhang Y, Wang Z, Dong Y, Zhao Y, Zheng J, Lian H, Jin Y. The serum level of D-dimer is not suitable for distinguishing between prosthetic joint infection and aseptic loosening. J Orthop Surg Res. 2019;14(1):407.CrossRef Huang J, Zhang Y, Wang Z, Dong Y, Zhao Y, Zheng J, Lian H, Jin Y. The serum level of D-dimer is not suitable for distinguishing between prosthetic joint infection and aseptic loosening. J Orthop Surg Res. 2019;14(1):407.CrossRef
9.
go back to reference Xiong L, Li S, Dai M. Comparison of D-dimer with CRP and ESR for diagnosis of periprosthetic joint infection. J Orthop Surg Res. 2019;14(1):240.CrossRef Xiong L, Li S, Dai M. Comparison of D-dimer with CRP and ESR for diagnosis of periprosthetic joint infection. J Orthop Surg Res. 2019;14(1):240.CrossRef
10.
go back to reference Pannu TS, Villa JM, Patel PD, Riesgo AM, Barsoum WK, Higuera CA. The utility of d-dimer for the diagnosis of periprosthetic joint infection in revision total hip and knee arthroplasty. J Arthroplast. 2020;35:1692–5.CrossRef Pannu TS, Villa JM, Patel PD, Riesgo AM, Barsoum WK, Higuera CA. The utility of d-dimer for the diagnosis of periprosthetic joint infection in revision total hip and knee arthroplasty. J Arthroplast. 2020;35:1692–5.CrossRef
11.
go back to reference Qin L, Li F, Gong X, Wang J, Huang W, Hu N. Combined measurement of D-dimer and c-reactive protein levels: Highly accurate for diagnosing chronic periprothetic joint infection. J Arthroplast. 2020;35:229–34.CrossRef Qin L, Li F, Gong X, Wang J, Huang W, Hu N. Combined measurement of D-dimer and c-reactive protein levels: Highly accurate for diagnosing chronic periprothetic joint infection. J Arthroplast. 2020;35:229–34.CrossRef
12.
go back to reference Hu Q, Fu Y, Tang L. Serum D-dimer as a diagnostic index of PJI and retrospective analysis of etiology in patients with PJI. Clin Chim Acta. 2020;506:67–71.CrossRef Hu Q, Fu Y, Tang L. Serum D-dimer as a diagnostic index of PJI and retrospective analysis of etiology in patients with PJI. Clin Chim Acta. 2020;506:67–71.CrossRef
13.
go back to reference Hamer HM, Stroobants AK, Bavalia R, Ponjee G, Klok FA, van der Hulle T, Huisman MV, Hendriks HA, Middeldorp S. Diagnostic accuracy of four different D-dimer assays: a post-hoc analysis of the YEARS study. Thromb Res. 2021;201:18–22.CrossRef Hamer HM, Stroobants AK, Bavalia R, Ponjee G, Klok FA, van der Hulle T, Huisman MV, Hendriks HA, Middeldorp S. Diagnostic accuracy of four different D-dimer assays: a post-hoc analysis of the YEARS study. Thromb Res. 2021;201:18–22.CrossRef
14.
go back to reference Morawietz L, Classen RA, Schröder JH, Dynybil C, Perka C, Skwara A, Neidel J, Gehrke T, Frommelt L, Hansen T, Otto M, Barden B, Aigner T, Stiehl P, Schubert T, Meyer-Scholten C, König A, Ströbel P, Rader CP, Kirschner S, Lintner F, Rüther W, Bos I, Hendrich C, Kriegsmann J, Krenn V. Proposal for a histopathological consensus classification of the periprosthetic interface membrane. J Clin Pathol. 2006;59(6):591–7.CrossRef Morawietz L, Classen RA, Schröder JH, Dynybil C, Perka C, Skwara A, Neidel J, Gehrke T, Frommelt L, Hansen T, Otto M, Barden B, Aigner T, Stiehl P, Schubert T, Meyer-Scholten C, König A, Ströbel P, Rader CP, Kirschner S, Lintner F, Rüther W, Bos I, Hendrich C, Kriegsmann J, Krenn V. Proposal for a histopathological consensus classification of the periprosthetic interface membrane. J Clin Pathol. 2006;59(6):591–7.CrossRef
15.
16.
go back to reference Zhang Q, Dong J, Zhou D, Liu F. Circulating D-dimer versus Fibrinogen in the diagnosis of periprosthetic joint infection: a meta-analysis. Surg Infect (Larchmt). 2021;22(2):200–10.CrossRef Zhang Q, Dong J, Zhou D, Liu F. Circulating D-dimer versus Fibrinogen in the diagnosis of periprosthetic joint infection: a meta-analysis. Surg Infect (Larchmt). 2021;22(2):200–10.CrossRef
17.
go back to reference Wang Y, Man Z, Yuan T, Cao H, Sun S. Reliability of D-dimer determination in diagnosis of peri-prosthetic joint infection. A systematic review and meta- analysis. Surg Infect (Larchmt). 2021;22(4):374–82.CrossRef Wang Y, Man Z, Yuan T, Cao H, Sun S. Reliability of D-dimer determination in diagnosis of peri-prosthetic joint infection. A systematic review and meta- analysis. Surg Infect (Larchmt). 2021;22(4):374–82.CrossRef
18.
go back to reference Lu G, Li T, Ye H, Liu S, Zhang P, Wang W. D-dimer in the diagnosis of periprosthetic joint infection: a systematic review and meta-analysis. J Orthop Surg Res. 2020;15(1):265.CrossRef Lu G, Li T, Ye H, Liu S, Zhang P, Wang W. D-dimer in the diagnosis of periprosthetic joint infection: a systematic review and meta-analysis. J Orthop Surg Res. 2020;15(1):265.CrossRef
19.
go back to reference Yan J, Xie K, Jiang X, Han X, Wang L, Yan M. D-dimer for diagnosis of periprosthetic joint infection: a meta-analysis. J Orthop Sci. 2020;S0949–2658(20):30284. Yan J, Xie K, Jiang X, Han X, Wang L, Yan M. D-dimer for diagnosis of periprosthetic joint infection: a meta-analysis. J Orthop Sci. 2020;S0949–2658(20):30284.
20.
go back to reference Chen X, Li H, Zhu S, Wang Y, Qian W. Is D-dimer a reliable biomarker compared to ESR and CRP in the diagnosis of periprosthetic joint infection? A systematic review and meta-analysis. Bone Joint Res. 2020;9(10):701–8.CrossRef Chen X, Li H, Zhu S, Wang Y, Qian W. Is D-dimer a reliable biomarker compared to ESR and CRP in the diagnosis of periprosthetic joint infection? A systematic review and meta-analysis. Bone Joint Res. 2020;9(10):701–8.CrossRef
21.
go back to reference Zhang H, Sun X, Xin P, Zhu X, Jie K, Cao H, Feng W, Zeng Y, Lv Y, Chen J, Li J, Zeng J, Zeng Y. Diagnostic accuracy of D-dimer in periprosthetic joint infection: a diagnostic meta-analysis. J Orthop Surg Res. 2020;15(1):334.CrossRef Zhang H, Sun X, Xin P, Zhu X, Jie K, Cao H, Feng W, Zeng Y, Lv Y, Chen J, Li J, Zeng J, Zeng Y. Diagnostic accuracy of D-dimer in periprosthetic joint infection: a diagnostic meta-analysis. J Orthop Surg Res. 2020;15(1):334.CrossRef
22.
go back to reference Tian B, Cui L, Jiang W. The diagnostic effect of α-defensin, D-dimer, and IL-6 in periprosthetic joint infection: a systematic review and diagnostic meta-analysis. J Orthop Surg (Hong Kong). 2020;28(3):2309499020971861.CrossRef Tian B, Cui L, Jiang W. The diagnostic effect of α-defensin, D-dimer, and IL-6 in periprosthetic joint infection: a systematic review and diagnostic meta-analysis. J Orthop Surg (Hong Kong). 2020;28(3):2309499020971861.CrossRef
23.
go back to reference Pan L, Wu H, Liu H, Yang X, Meng Z, Cao Y. Fibrinogen performs better than D-dimer for the diagnosis of periprosthetic joint infection: a meta-analysis of diagnostic trials. J Orthop Surg Res. 2021;16(1):30.CrossRef Pan L, Wu H, Liu H, Yang X, Meng Z, Cao Y. Fibrinogen performs better than D-dimer for the diagnosis of periprosthetic joint infection: a meta-analysis of diagnostic trials. J Orthop Surg Res. 2021;16(1):30.CrossRef
24.
go back to reference Fu J, Ni M, Chai W, Li X, Hao L, Chen J. Synovial fluid viscosity test is promising for the diagnosis of periprosthetic joint infection. J Arthroplasty. 2019;34(6):1197–200.CrossRef Fu J, Ni M, Chai W, Li X, Hao L, Chen J. Synovial fluid viscosity test is promising for the diagnosis of periprosthetic joint infection. J Arthroplasty. 2019;34(6):1197–200.CrossRef
25.
go back to reference Li R, Shao HY, Hao LB, Yu BZ, Qu PF, Zhou YX, et al. Plasma fibrinogen exhibits better performance than plasma D-dimer in the diagnosis of periprosthetic joint infection: a multicenter retrospective study. J Bone Joint Surg Am. 2019;101(7):613–9.CrossRef Li R, Shao HY, Hao LB, Yu BZ, Qu PF, Zhou YX, et al. Plasma fibrinogen exhibits better performance than plasma D-dimer in the diagnosis of periprosthetic joint infection: a multicenter retrospective study. J Bone Joint Surg Am. 2019;101(7):613–9.CrossRef
26.
go back to reference Xu H, Xie J, Huang Q, Lei Y, Zhang S, Pei F. Plasma fibrin degradation product and D-dimer are of limited value for diagnosing periprosthetic joint infection. J Arthroplasty. 2019;34(10):2454–60.CrossRef Xu H, Xie J, Huang Q, Lei Y, Zhang S, Pei F. Plasma fibrin degradation product and D-dimer are of limited value for diagnosing periprosthetic joint infection. J Arthroplasty. 2019;34(10):2454–60.CrossRef
27.
go back to reference Wu H, Meng Z, Pan L, Liu H, Yang X, Yongping C. Plasma fibrinogen performs better than plasma d-dimer and fibrin degradation product in the diagnosis of periprosthetic joint infection and determination of reimplantation timing. J Arthroplasty. 2020;35(8):2230–6.CrossRef Wu H, Meng Z, Pan L, Liu H, Yang X, Yongping C. Plasma fibrinogen performs better than plasma d-dimer and fibrin degradation product in the diagnosis of periprosthetic joint infection and determination of reimplantation timing. J Arthroplasty. 2020;35(8):2230–6.CrossRef
28.
go back to reference Ackmann T, Möllenbeck B, Gosheger G, Schwarze J, Schmidt-Braekling T, Schneider KN, Frommer A, Dieckmann R, Theil C. Comparing the diagnostic value of serum D-dimer to CRP and IL-6 in the diagnosis of chronic prosthetic joint infection. J Clin Med. 2020;9(9):2917.CrossRef Ackmann T, Möllenbeck B, Gosheger G, Schwarze J, Schmidt-Braekling T, Schneider KN, Frommer A, Dieckmann R, Theil C. Comparing the diagnostic value of serum D-dimer to CRP and IL-6 in the diagnosis of chronic prosthetic joint infection. J Clin Med. 2020;9(9):2917.CrossRef
30.
go back to reference Chen X, Qian W, Weng X, Lin J, Wang Y, Zhu S. Different diagnostic performance of fibrinogen and D-dimer in periprosthteic joint infection: a propensity score matched study. BMC Musculoskelet Disord. 2021;22:422.CrossRef Chen X, Qian W, Weng X, Lin J, Wang Y, Zhu S. Different diagnostic performance of fibrinogen and D-dimer in periprosthteic joint infection: a propensity score matched study. BMC Musculoskelet Disord. 2021;22:422.CrossRef
31.
go back to reference Pieper CT, Rao KM, Currie MS, Harris TB, Cohen HJ. Age, functional status and racial differences in plasma D-dimer levels in community dwelling eldery persons. J Gerontol A Biol Sci Med Sci. 2000;55:M649.CrossRef Pieper CT, Rao KM, Currie MS, Harris TB, Cohen HJ. Age, functional status and racial differences in plasma D-dimer levels in community dwelling eldery persons. J Gerontol A Biol Sci Med Sci. 2000;55:M649.CrossRef
32.
go back to reference Grzelecki D, Walczak P, Grajek A, Szostek M, Dudek P, Bartosz P, Olewnik Ł, Czubak-Wrzosek M, Marczak D, TyraKowski M. Elevated plasma D-dimer concentration has higher efficacy for the diagnosis of periprosthetic joint infection of the knee than of the hip-A single-center, retrospective study. J Orthop Res. 2021;39(2):291–8.CrossRef Grzelecki D, Walczak P, Grajek A, Szostek M, Dudek P, Bartosz P, Olewnik Ł, Czubak-Wrzosek M, Marczak D, TyraKowski M. Elevated plasma D-dimer concentration has higher efficacy for the diagnosis of periprosthetic joint infection of the knee than of the hip-A single-center, retrospective study. J Orthop Res. 2021;39(2):291–8.CrossRef
33.
go back to reference Korte W, Riesen W. Latex-enhanced immunoturbidimetry allows D-dimer determination in plasma and serum samples. Clin Chem. 2000;46:871–2.CrossRef Korte W, Riesen W. Latex-enhanced immunoturbidimetry allows D-dimer determination in plasma and serum samples. Clin Chem. 2000;46:871–2.CrossRef
34.
go back to reference Li C, Margaryan D, Ojeda-Thies C, Carsten Perka C, Trampuz A. Meta-analysis of serum and/or plasma D-dimer in the diagnosis of periprosthetic joint infection. J Orthop Surg Res. 2020;15:298.CrossRef Li C, Margaryan D, Ojeda-Thies C, Carsten Perka C, Trampuz A. Meta-analysis of serum and/or plasma D-dimer in the diagnosis of periprosthetic joint infection. J Orthop Surg Res. 2020;15:298.CrossRef
35.
go back to reference Lee YS, Lee YK, Han SB, Nam CH, Parvizi J, Koo KH. Natural progress of Ddimer following total joint arthroplasty: a baseline for the diagnosis of the early postoperative infection. J Orthop Surg Res. 2018;13:36.CrossRef Lee YS, Lee YK, Han SB, Nam CH, Parvizi J, Koo KH. Natural progress of Ddimer following total joint arthroplasty: a baseline for the diagnosis of the early postoperative infection. J Orthop Surg Res. 2018;13:36.CrossRef
Metadata
Title
The poor accuracy of D-dimer for the diagnosis of prosthetic joint infection but its potential usefulness in early postoperative infections following revision arthroplasty for aseptic loosening
Authors
M. Fernandez-Sampedro
I. Sanlés-González
C. García-Ibarbia
N. Fañanás-Rodríquez
M. Fakkas-Fernández
M. C. Fariñas
Publication date
01-12-2022
Publisher
BioMed Central
Keyword
Joint Infection
Published in
BMC Infectious Diseases / Issue 1/2022
Electronic ISSN: 1471-2334
DOI
https://doi.org/10.1186/s12879-022-07060-8

Other articles of this Issue 1/2022

BMC Infectious Diseases 1/2022 Go to the issue