Skip to main content
Top
Published in: BMC Infectious Diseases 1/2017

Open Access 01-12-2017 | Research article

Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis

Authors: Baye Gelaw, Yitayal Shiferaw, Marta Alemayehu, Abate Assefa Bashaw

Published in: BMC Infectious Diseases | Issue 1/2017

Login to get access

Abstract

Background

Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading causes of death from infectious diseases worldwide. Sputum smear microscopy remains the most widely available pulmonary TB diagnostic tool particularly in resource limited settings. A highly sensitive diagnostic with minimal infrastructure, cost and training is required. Hence, we assessed the diagnostic performance of Loop-mediated isothermal amplification (LAMP) assay in detecting M.tuberculosis infection in sputum sample compared to LED fluorescent smear microscopy and culture.

Method

A cross-sectional study was conducted at the University of Gondar Hospital from June 01, 2015 to August 30, 2015. Pulmonary TB diagnosis using sputum LED fluorescence smear microscopy, TB-LAMP assay and culture were done. A descriptive analysis was used to determine demographic characteristics of the study participants. Analysis of sensitivity and specificity for smear microscopy and TB-LAMP compared with culture as a reference test was performed. Cohen’s kappa was calculated as a measure of agreement between the tests.

Results

A total of 78 pulmonary presumptive TB patients sputum sample were analyzed. The overall sensitivity and specificity of LAMP were 75 and 98%, respectively. Among smear negative sputum samples, 33.3% sensitivity and 100% specificity of LAMP were observed. Smear microscopy showed 78.6% sensitivity and 98% specificity. LAMP and smear in series had sensitivity of 67.8% and specificity of 100%. LAMP and smear in parallel had sensitivity of 85.7% and specificity of 96%. The agreement between LAMP and fluorescent smear microscopy tests was very good (κ = 0.83, P-value ≤0.0001).

Conclusions

TB-LAMP showed similar specificity but a slightly lower sensitivity with LED fluorescence microscopy. The specificity of LAMP and smear microscopy in series was high. The sensitivity of LAMP was insufficient for smear negative sputum samples.
Literature
1.
go back to reference Stop TB partnership. The global plan to stop TB 2011–2015: transforming the fight towards elimination of tuberculosis. In: World health organization. 2010. Accessed on 10 June 2012. Available at: http://www.stoptb.org/assets/documents/global/plan/TB_GlobalPlanToStopTB 2011–2015.pdf. Stop TB partnership. The global plan to stop TB 2011–2015: transforming the fight towards elimination of tuberculosis. In: World health organization. 2010. Accessed on 10 June 2012. Available at: http://​www.​stoptb.​org/​assets/​documents/​global/​plan/​TB_​GlobalPlanToStop​TB 2011–2015.pdf.
2.
go back to reference Federal ministry of health. Tuberculosis, leprosy and TB/HIV prevention and control program manua. In: Ethiopia federal ministry of health. 2008. Accessed on 15 June 2012. Available at: http://www.who.int/hiv/pub/guidelines/ethiopia_tb.pdf. Federal ministry of health. Tuberculosis, leprosy and TB/HIV prevention and control program manua. In: Ethiopia federal ministry of health. 2008. Accessed on 15 June 2012. Available at: http://​www.​who.​int/​hiv/​pub/​guidelines/​ethiopia_​tb.​pdf.​
3.
go back to reference Kent BD, Kubica GP. Public Health Mycobacteriology: a Guide for the Level III Laboratory. US Department of Health and Human Services, Centers for Disease Control. 1985. Kent BD, Kubica GP. Public Health Mycobacteriology: a Guide for the Level III Laboratory. US Department of Health and Human Services, Centers for Disease Control. 1985.
4.
go back to reference Bi A, Nakajima C, Fukushima Y, Tamaru A, Sugawara I, Kimura A, Kawahara R, Hu Z, Suzuki Y. A rapid loop-mediated isothermal amplification assay targeting hspX for the detection of mycobacterium tuberculosis complex. Jpn J Infect Dis. 2012;65:247–51.CrossRefPubMed Bi A, Nakajima C, Fukushima Y, Tamaru A, Sugawara I, Kimura A, Kawahara R, Hu Z, Suzuki Y. A rapid loop-mediated isothermal amplification assay targeting hspX for the detection of mycobacterium tuberculosis complex. Jpn J Infect Dis. 2012;65:247–51.CrossRefPubMed
5.
go back to reference Mathew P, Kuo YH, Vazirani B, Eng RHK, Weinstein MP. Are three sputum acid fast bacillus smears necessary for discontinuing tuberculosis isolation? J Clin Microbiol. 2002;40:3482–4.PubMedPubMedCentral Mathew P, Kuo YH, Vazirani B, Eng RHK, Weinstein MP. Are three sputum acid fast bacillus smears necessary for discontinuing tuberculosis isolation? J Clin Microbiol. 2002;40:3482–4.PubMedPubMedCentral
6.
go back to reference WHO. Fluorescent light emitting diode (LED) microscopy for diagnosis of tuberculosis: policy statement. In: World Health Organization. 2010. Accessed on 15 June 2012. Available at:http://www.who.int/tb/laboratory/who_policy_led_microscopy_july10.pdf. WHO. Fluorescent light emitting diode (LED) microscopy for diagnosis of tuberculosis: policy statement. In: World Health Organization. 2010. Accessed on 15 June 2012. Available at:http://​www.​who.​int/​tb/​laboratory/​who_​policy_​led_​microscopy_​july10.​pdf.​
7.
go back to reference Parsons LM, Somoskövi A, Gutierrez C, Lee E, Paramasivan CN, Abimiku A, Spector S, Roscigno G, Nkengasong J. Laboratory diagnosis of tuberculosis in resource poor countries: challenges and opportunities. Clin Microbiol Rev. 2011;24(2):314–50.CrossRefPubMedPubMedCentral Parsons LM, Somoskövi A, Gutierrez C, Lee E, Paramasivan CN, Abimiku A, Spector S, Roscigno G, Nkengasong J. Laboratory diagnosis of tuberculosis in resource poor countries: challenges and opportunities. Clin Microbiol Rev. 2011;24(2):314–50.CrossRefPubMedPubMedCentral
8.
go back to reference Marais BJ, Brittle W, Painczyk K, Hesseling AC, Beyers N, Wasserman E, van Soolingen D, Warren RM. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum. Clin Infect Dis. 2008;47(2):203–7.CrossRefPubMed Marais BJ, Brittle W, Painczyk K, Hesseling AC, Beyers N, Wasserman E, van Soolingen D, Warren RM. Use of light-emitting diode fluorescence microscopy to detect acid-fast bacilli in sputum. Clin Infect Dis. 2008;47(2):203–7.CrossRefPubMed
9.
go back to reference Chamie G, Luetkemeyer A, Charlebois E, Havlir DV. Tuberculosis as part of the natural history of HIV infection in developing countries. Clin Infect Dis. 2010;50:S245–54.CrossRefPubMedPubMedCentral Chamie G, Luetkemeyer A, Charlebois E, Havlir DV. Tuberculosis as part of the natural history of HIV infection in developing countries. Clin Infect Dis. 2010;50:S245–54.CrossRefPubMedPubMedCentral
10.
go back to reference CDC. National action plan to combat multidrug-resistant tuberculosis: summary of a conference; management of persons exposed to multidrug-resistant tuberculosis. MMWR. 1992;41:5–48. CDC. National action plan to combat multidrug-resistant tuberculosis: summary of a conference; management of persons exposed to multidrug-resistant tuberculosis. MMWR. 1992;41:5–48.
11.
go back to reference American Thoracic Society. Diagnostic standards and classification of tuberculosis in adults and children, 1999. Am J RespirCrit Care Med. 2000;161:1376–95.CrossRef American Thoracic Society. Diagnostic standards and classification of tuberculosis in adults and children, 1999. Am J RespirCrit Care Med. 2000;161:1376–95.CrossRef
12.
go back to reference Boehme CC, Nabeta P, Henostroza G, Raqib R, Rahim Z, Gerhardt M, Sanga E, Hoelscher M, Notomi T, Hase T, Perkins MD. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007;45:1936–40.CrossRefPubMedPubMedCentral Boehme CC, Nabeta P, Henostroza G, Raqib R, Rahim Z, Gerhardt M, Sanga E, Hoelscher M, Notomi T, Hase T, Perkins MD. Operational feasibility of using loop-mediated isothermal amplification for diagnosis of pulmonary tuberculosis in microscopy centers of developing countries. J Clin Microbiol. 2007;45:1936–40.CrossRefPubMedPubMedCentral
14.
go back to reference Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28:e63.CrossRefPubMedPubMedCentral Notomi T, Okayama H, Masubuchi H, Yonekawa T, Watanabe K, Amino N, Hase T. Loop-mediated isothermal amplification of DNA. Nucleic Acids Res. 2000;28:e63.CrossRefPubMedPubMedCentral
15.
go back to reference World Health Organization. The use of a commercial loop-mediated isothermal amplification assay (TB-LAMP) for the detection of tuberculosis: expert group meeting report. Geneva, Switzerland: WHO; 2013. World Health Organization. The use of a commercial loop-mediated isothermal amplification assay (TB-LAMP) for the detection of tuberculosis: expert group meeting report. Geneva, Switzerland: WHO; 2013.
16.
go back to reference Nagamine K, Hase T, Notomi T. Accelerated reaction by loopmediated isothermal amplification using loop primers. Mol Cell Probes. 2002;16:223–9.CrossRefPubMed Nagamine K, Hase T, Notomi T. Accelerated reaction by loopmediated isothermal amplification using loop primers. Mol Cell Probes. 2002;16:223–9.CrossRefPubMed
17.
go back to reference Thai HTC, Mai QL, Vuong CD, Parida M, Minekawa H, Notomi T, Hasebe F, Morita K. Development and evaluation of a novel loop-mediated isothermal amplification method for rapid detection of severe acute respiratory syndrome coronavirus. J Clin Microbiol. 2004;42:1956–61.CrossRefPubMedCentral Thai HTC, Mai QL, Vuong CD, Parida M, Minekawa H, Notomi T, Hasebe F, Morita K. Development and evaluation of a novel loop-mediated isothermal amplification method for rapid detection of severe acute respiratory syndrome coronavirus. J Clin Microbiol. 2004;42:1956–61.CrossRefPubMedCentral
18.
go back to reference Adhikari BR, Pandey BD, Ghimire P, Shrestha B, Khadka M, Yoda T, Suzuki Y. Loop-mediated isothermal amplification (LAMP) for the direct detection of human pulmonary infections with environmental (nontuberculosis) mycobacteria. Jpn J Infect Dis. 2009;62:212–4.PubMed Adhikari BR, Pandey BD, Ghimire P, Shrestha B, Khadka M, Yoda T, Suzuki Y. Loop-mediated isothermal amplification (LAMP) for the direct detection of human pulmonary infections with environmental (nontuberculosis) mycobacteria. Jpn J Infect Dis. 2009;62:212–4.PubMed
19.
go back to reference Ou X, Li Q, Xia H, Pang Y, Wang S, Zhao B, Song Y, Zhou Y, Zheng Y, Zhang Z, Zhang Z, Li J, Dong H, Zhang J, Kam KM, Chi J, Huan S, Chin DP, Zhao Y. Diagnostic accuracy of the PURE-LAMP test for pulmonary tuberculosis at the county-level laboratory in China. PLoS One. 2014;9(5):e94544. Ou X, Li Q, Xia H, Pang Y, Wang S, Zhao B, Song Y, Zhou Y, Zheng Y, Zhang Z, Zhang Z, Li J, Dong H, Zhang J, Kam KM, Chi J, Huan S, Chin DP, Zhao Y. Diagnostic accuracy of the PURE-LAMP test for pulmonary tuberculosis at the county-level laboratory in China. PLoS One. 2014;9(5):e94544.
20.
go back to reference Keeler E, Perkins MD, Small P, Hanson C, Reed S, Cunningham J, Aledort JE, Hillborne L, Rafael ME, Girosi F, Dye C. Reducing the global burden of tuberculosis: the contribution of improved diagnostics. Nature. 2006;444 Suppl 1:49–57.CrossRefPubMed Keeler E, Perkins MD, Small P, Hanson C, Reed S, Cunningham J, Aledort JE, Hillborne L, Rafael ME, Girosi F, Dye C. Reducing the global burden of tuberculosis: the contribution of improved diagnostics. Nature. 2006;444 Suppl 1:49–57.CrossRefPubMed
21.
go back to reference George G, Mony P, Kenneth J. Comparisons of the efficacies of loop-mediated isothermal amplification, fluorescence smear microscopy andculture for the diagnosis of tuberculosis. PLoS One. 2011;6(6):e21007.CrossRefPubMedPubMedCentral George G, Mony P, Kenneth J. Comparisons of the efficacies of loop-mediated isothermal amplification, fluorescence smear microscopy andculture for the diagnosis of tuberculosis. PLoS One. 2011;6(6):e21007.CrossRefPubMedPubMedCentral
22.
go back to reference Bojang AL, Mendy FS, Tientcheu LD, Otu J, Antonio M, Kampmann B, Agbla S, Sutherland JS. Comparison of TB-LAMP, gene X-pert MTB/RIF and culture for diagnosis of pulmonary tuberculosis in the Gambia. J Infect. 2016;72(3):332–7.CrossRefPubMed Bojang AL, Mendy FS, Tientcheu LD, Otu J, Antonio M, Kampmann B, Agbla S, Sutherland JS. Comparison of TB-LAMP, gene X-pert MTB/RIF and culture for diagnosis of pulmonary tuberculosis in the Gambia. J Infect. 2016;72(3):332–7.CrossRefPubMed
Metadata
Title
Comparison of loop-mediated isothermal amplification assay and smear microscopy with culture for the diagnostic accuracy of tuberculosis
Authors
Baye Gelaw
Yitayal Shiferaw
Marta Alemayehu
Abate Assefa Bashaw
Publication date
01-12-2017
Publisher
BioMed Central
Published in
BMC Infectious Diseases / Issue 1/2017
Electronic ISSN: 1471-2334
DOI
https://doi.org/10.1186/s12879-016-2140-8

Other articles of this Issue 1/2017

BMC Infectious Diseases 1/2017 Go to the issue