Published in: BMC Cardiovascular Disorders 1/2018

Open Access 01-12-2018 | Research article

Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting

Authors: Susanne Röger, Stefanie L. Rosenkaimer, Anna Hohneck, Siegfried Lang, Ibrahim El-Battrawy, Boris Rudic, Erol Tülümen, Ksenija Stach, Jürgen Kuschyk, Ibrahim Akin, Martin Borggrefe

Published in: BMC Cardiovascular Disorders | Issue 1/2018

Login to get access

Abstract

Background

The wearable cardioverter-defibrillator (WCD) has emerged as a valuable tool to temporarily protect patients at risk for sudden cardiac death (SCD). The aim of this study was to determine the value of the WCD for therapy optimization of heart failure patients.

Methods

One hundred five consecutive patients that received WCD between 4/2012 and 9/2016 were included in the study. All patients were followed for clinical outcome and echocardiographic parameters during WCD therapy and had continued follow-up after WCD therapy, irrespective of subsequent implantable cardioverter-defibrillator (ICD) implantation.

Results

The most common indication for WCD were newly diagnosed ischemic (ICM) or non-ischemic cardiomyopathy (NICM) with left ventricular ejection fraction (LVEF) ≤35%. Mean WCD wear time was 68.8 ± 50.4 days with a mean daily use of 21.5 ± 3.5 h. Five patients (4.8%) received a total of five appropriate WCD shocks.
During WCD wear, patients with ICM and NICM showed significant improvement in LVEF, reducing the proportion of patients with a need for primary preventive ICD implantation to 54.8% (ICM) and 48.8% (NICM). An ICD was finally implanted in 51.4% of the study patients (24 trans-venous ICDs, 30 subcutaneous ICDs).
After discontinuation of WCD therapy, all patients were followed for a mean of 18.6 ± 12.3 months. 5.6% of patients with implanted ICDs received appropriate therapies. No patient with subcutaneous ICD needed change to a trans-venous device. None of the patients without an implanted ICD suffered from ventricular tachyarrhythmias and no patient died suddenly.
In patients with NICM a significant LVEF improvement was observed during long-term follow-up (from 34.8 ± 11.1% to 41.0 ± 10.2%).

Conclusions

WCD therapy successfully bridged all patients to either LVEF recovery or ICD implantation. Following WCD, ICD implantation could be avoided in almost half of the patients. In selected patients, prolongation of WCD therapy beyond 3 months might further prevent unnecessary ICD implantation. The WCD as an external monitoring system contributed important information to optimize device selection in patients that needed ICD implantation.
Literature
1.
go back to reference Desai AS, McMurray JJ, Packer M, Swedberg K, Rouleau JL, Chen F, Gong J, Rizkala AR, Brahimi A, Claggett B, et al. Effect of the angiotensin-receptor-neprilysin inhibitor LCZ696 compared with enalapril on mode of death in heart failure patients. Eur Heart J. 2015;36(30):1990–7.CrossRefPubMed Desai AS, McMurray JJ, Packer M, Swedberg K, Rouleau JL, Chen F, Gong J, Rizkala AR, Brahimi A, Claggett B, et al. Effect of the angiotensin-receptor-neprilysin inhibitor LCZ696 compared with enalapril on mode of death in heart failure patients. Eur Heart J. 2015;36(30):1990–7.CrossRefPubMed
2.
go back to reference Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, Domanski M, Troutman C, Anderson J, Johnson G, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed
3.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, Daubert JP, Higgins SL, Brown MW, Andrews ML, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed
4.
go back to reference Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JG, Coats AJ, Falk V, Gonzalez-Juanatey JR, Harjola VP, Jankowska EA, et al. 2016 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)developed with the special contribution of the heart failure association (HFA) of the ESC. Eur Heart J. 2016;37(27):2129–200.CrossRefPubMed Ponikowski P, Voors AA, Anker SD, Bueno H, Cleland JG, Coats AJ, Falk V, Gonzalez-Juanatey JR, Harjola VP, Jankowska EA, et al. 2016 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure: the task force for the diagnosis and treatment of acute and chronic heart failure of the European Society of Cardiology (ESC)developed with the special contribution of the heart failure association (HFA) of the ESC. Eur Heart J. 2016;37(27):2129–200.CrossRefPubMed
5.
go back to reference Solomon SD, Zelenkofske S, McMurray JJ, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleau JL, Maggioni A, Kober L, et al. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005;352(25):2581–8.CrossRefPubMed Solomon SD, Zelenkofske S, McMurray JJ, Finn PV, Velazquez E, Ertl G, Harsanyi A, Rouleau JL, Maggioni A, Kober L, et al. Sudden death in patients with myocardial infarction and left ventricular dysfunction, heart failure, or both. N Engl J Med. 2005;352(25):2581–8.CrossRefPubMed
6.
go back to reference Steinbeck G, Andresen D, Seidl K, Brachmann J, Hoffmann E, Wojciechowski D, Kornacewicz-Jach Z, Sredniawa B, Lupkovics G, Hofgartner F, et al. Defibrillator implantation early after myocardial infarction. N Engl J Med. 2009;361(15):1427–36.CrossRefPubMed Steinbeck G, Andresen D, Seidl K, Brachmann J, Hoffmann E, Wojciechowski D, Kornacewicz-Jach Z, Sredniawa B, Lupkovics G, Hofgartner F, et al. Defibrillator implantation early after myocardial infarction. N Engl J Med. 2009;361(15):1427–36.CrossRefPubMed
7.
go back to reference Sheppard R, Mather PJ, Alexis JD, Starling RC, Boehmer JP, Thohan V, Pauly DF, Markham DW, Zucker M, Kip KE, et al. Implantable cardiac defibrillators and sudden death in recent onset nonischemic cardiomyopathy: results from IMAC2. J Card Fail. 2012;18(9):675–81.CrossRefPubMed Sheppard R, Mather PJ, Alexis JD, Starling RC, Boehmer JP, Thohan V, Pauly DF, Markham DW, Zucker M, Kip KE, et al. Implantable cardiac defibrillators and sudden death in recent onset nonischemic cardiomyopathy: results from IMAC2. J Card Fail. 2012;18(9):675–81.CrossRefPubMed
8.
go back to reference Chung MK, Szymkiewicz SJ, Shao M, Zishiri E, Niebauer MJ, Lindsay BD, Tchou PJ. Aggregate national experience with the wearable cardioverter-defibrillator: event rates, compliance, and survival. J Am Coll Cardiol. 2010;56(3):194–203.CrossRefPubMedPubMedCentral Chung MK, Szymkiewicz SJ, Shao M, Zishiri E, Niebauer MJ, Lindsay BD, Tchou PJ. Aggregate national experience with the wearable cardioverter-defibrillator: event rates, compliance, and survival. J Am Coll Cardiol. 2010;56(3):194–203.CrossRefPubMedPubMedCentral
9.
go back to reference Kutyifa V, Moss AJ, Klein H, Biton Y, McNitt S, MacKecknie B, Zareba W, Goldenberg I. Use of the wearable cardioverter defibrillator in high-risk cardiac patients: data from the prospective registry of patients using the wearable cardioverter defibrillator (WEARIT-II registry). Circulation. 2015;132(17):1613–9.CrossRefPubMed Kutyifa V, Moss AJ, Klein H, Biton Y, McNitt S, MacKecknie B, Zareba W, Goldenberg I. Use of the wearable cardioverter defibrillator in high-risk cardiac patients: data from the prospective registry of patients using the wearable cardioverter defibrillator (WEARIT-II registry). Circulation. 2015;132(17):1613–9.CrossRefPubMed
10.
go back to reference Wassnig NK, Gunther M, Quick S, Pfluecke C, Rottstadt F, Szymkiewicz SJ, Ringquist S, Strasser RH, Speiser U. Experience with the wearable cardioverter-defibrillator in patients at high risk for sudden cardiac death. Circulation. 2016;134(9):635–43.CrossRefPubMedPubMedCentral Wassnig NK, Gunther M, Quick S, Pfluecke C, Rottstadt F, Szymkiewicz SJ, Ringquist S, Strasser RH, Speiser U. Experience with the wearable cardioverter-defibrillator in patients at high risk for sudden cardiac death. Circulation. 2016;134(9):635–43.CrossRefPubMedPubMedCentral
11.
go back to reference Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, Elliott PM, Fitzsimons D, Hatala R, Hindricks G, et al. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36(41):2793–867.CrossRefPubMed Priori SG, Blomstrom-Lundqvist C, Mazzanti A, Blom N, Borggrefe M, Camm J, Elliott PM, Fitzsimons D, Hatala R, Hindricks G, et al. 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC). Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Eur Heart J. 2015;36(41):2793–867.CrossRefPubMed
12.
go back to reference Epstein AE, Abraham WT, Bianco NR, Kern KB, Mirro M, Rao SV, Rhee EK, Solomon SD, Szymkiewicz SJ. Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction. J Am Coll Cardiol. 2013;62(21):2000–7.CrossRefPubMed Epstein AE, Abraham WT, Bianco NR, Kern KB, Mirro M, Rao SV, Rhee EK, Solomon SD, Szymkiewicz SJ. Wearable cardioverter-defibrillator use in patients perceived to be at high risk early post-myocardial infarction. J Am Coll Cardiol. 2013;62(21):2000–7.CrossRefPubMed
13.
go back to reference Salehi N, Nasiri M, Bianco NR, Opreanu M, Singh V, Satija V, Jhand AS, Karapetyan L, Safadi AR, Surapaneni P, et al. The wearable cardioverter defibrillator in Nonischemic cardiomyopathy: a US National Database Analysis. Can J Cardiol. 2016;32(10):1247. e1241-7 e1246CrossRefPubMed Salehi N, Nasiri M, Bianco NR, Opreanu M, Singh V, Satija V, Jhand AS, Karapetyan L, Safadi AR, Surapaneni P, et al. The wearable cardioverter defibrillator in Nonischemic cardiomyopathy: a US National Database Analysis. Can J Cardiol. 2016;32(10):1247. e1241-7 e1246CrossRefPubMed
14.
go back to reference Erath JW, Vamos M, Sirat AS, Hohnloser SH. The wearable cardioverter-defibrillator in a real-world clinical setting: experience in 102 consecutive patients. Clin Res Cardiol. 2017;106(4):300–6.CrossRefPubMed Erath JW, Vamos M, Sirat AS, Hohnloser SH. The wearable cardioverter-defibrillator in a real-world clinical setting: experience in 102 consecutive patients. Clin Res Cardiol. 2017;106(4):300–6.CrossRefPubMed
15.
go back to reference Duncker D, Konig T, Hohmann S, Bauersachs J, Veltmann C. Avoiding untimely implantable cardioverter/defibrillator implantation by intensified heart failure therapy optimization supported by the wearable cardioverter/defibrillator-the PROLONG study. J Am Heart Assoc. 2017;6(1) https://doi.org/10.1161/JAHA.116.004512. Duncker D, Konig T, Hohmann S, Bauersachs J, Veltmann C. Avoiding untimely implantable cardioverter/defibrillator implantation by intensified heart failure therapy optimization supported by the wearable cardioverter/defibrillator-the PROLONG study. J Am Heart Assoc. 2017;6(1) https://​doi.​org/​10.​1161/​JAHA.​116.​004512.
16.
go back to reference Beiert T, Malotki R, Kraemer N, Stockigt F, Linhart M, Nickenig G, Schrickel JW, Andrie RP. A real world wearable cardioverter defibrillator experience - very high appropriate shock rate in ischemic cardiomyopathy patients at a European single-center. J Electrocardiol. 2017;50(5):603–9.CrossRefPubMed Beiert T, Malotki R, Kraemer N, Stockigt F, Linhart M, Nickenig G, Schrickel JW, Andrie RP. A real world wearable cardioverter defibrillator experience - very high appropriate shock rate in ischemic cardiomyopathy patients at a European single-center. J Electrocardiol. 2017;50(5):603–9.CrossRefPubMed
17.
go back to reference Singh M, Wang NC, Jain S, Voigt AH, Saba S, Adelstein EC. Utility of the wearable cardioverter-defibrillator in patients with newly diagnosed cardiomyopathy: a decade-long single-center experience. J Am Coll Cardiol. 2015;66(23):2607–13.CrossRefPubMed Singh M, Wang NC, Jain S, Voigt AH, Saba S, Adelstein EC. Utility of the wearable cardioverter-defibrillator in patients with newly diagnosed cardiomyopathy: a decade-long single-center experience. J Am Coll Cardiol. 2015;66(23):2607–13.CrossRefPubMed
18.
go back to reference Duncker D, Konig T, Hohmann S, Bauersachs J, Veltmann C. Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: insights from the PROLONG study. Clin Cardiol. 2017;40(8):586–90.CrossRefPubMed Duncker D, Konig T, Hohmann S, Bauersachs J, Veltmann C. Ventricular arrhythmias in patients with newly diagnosed nonischemic cardiomyopathy: insights from the PROLONG study. Clin Cardiol. 2017;40(8):586–90.CrossRefPubMed
19.
go back to reference Lenarczyk R, Potpara TS, Haugaa KH, Hernandez-Madrid A, Sciaraffia E, Dagres N. Scientific initiatives committee EHRA. The use of wearable cardioverter-defibrillators in Europe: results of the European heart rhythm association survey. Europace. 2016;18(1):146–50.CrossRefPubMed Lenarczyk R, Potpara TS, Haugaa KH, Hernandez-Madrid A, Sciaraffia E, Dagres N. Scientific initiatives committee EHRA. The use of wearable cardioverter-defibrillators in Europe: results of the European heart rhythm association survey. Europace. 2016;18(1):146–50.CrossRefPubMed
20.
go back to reference Barraud J, Cautela J, Orabona M, Pinto J, Missenard O, Laine M, Thuny F, Paganelli F, Bonello L, Peyrol M. Wearable cardioverter defibrillator: bridge or alternative to implantation? World J Cardiol. 2017;9(6):531–8.CrossRefPubMedPubMedCentral Barraud J, Cautela J, Orabona M, Pinto J, Missenard O, Laine M, Thuny F, Paganelli F, Bonello L, Peyrol M. Wearable cardioverter defibrillator: bridge or alternative to implantation? World J Cardiol. 2017;9(6):531–8.CrossRefPubMedPubMedCentral
21.
go back to reference Quast A, van Dijk VF, Wilde AAM, Knops RE, Boersma LVA. Outpatient treatment with the wearable cardioverter defibrillator: clinical experience in two Dutch centres. Neth Heart J. 2017;25(5):312–7.CrossRefPubMedPubMedCentral Quast A, van Dijk VF, Wilde AAM, Knops RE, Boersma LVA. Outpatient treatment with the wearable cardioverter defibrillator: clinical experience in two Dutch centres. Neth Heart J. 2017;25(5):312–7.CrossRefPubMedPubMedCentral
22.
go back to reference Kao AC, Krause SW, Handa R, Karia D, Reyes G, Bianco NR, Szymkiewicz SJ. Wearable defibrillator use in heart failure I: wearable defibrillator use in heart failure (WIF): results of a prospective registry. BMC Cardiovasc Disord. 2012;12:123.CrossRefPubMedPubMedCentral Kao AC, Krause SW, Handa R, Karia D, Reyes G, Bianco NR, Szymkiewicz SJ. Wearable defibrillator use in heart failure I: wearable defibrillator use in heart failure (WIF): results of a prospective registry. BMC Cardiovasc Disord. 2012;12:123.CrossRefPubMedPubMedCentral
23.
go back to reference Sjoblom J, Muhrbeck J, Witt N, Alam M, Frykman-Kull V. Evolution of left ventricular ejection fraction after acute myocardial infarction: implications for implantable cardioverter-defibrillator eligibility. Circulation. 2014;130(9):743–8.CrossRefPubMed Sjoblom J, Muhrbeck J, Witt N, Alam M, Frykman-Kull V. Evolution of left ventricular ejection fraction after acute myocardial infarction: implications for implantable cardioverter-defibrillator eligibility. Circulation. 2014;130(9):743–8.CrossRefPubMed
24.
go back to reference Verma A, Wulffhart Z, Lakkireddy D, Khaykin Y, Kaplan A, Sarak B, Biria M, Pillarisetti J, Bhat P, Di Biase L, et al. Incidence of left ventricular function improvement after primary prevention ICD implantation for non-ischaemic dilated cardiomyopathy: a multicentre experience. Heart. 2010;96(7):510–5.CrossRefPubMed Verma A, Wulffhart Z, Lakkireddy D, Khaykin Y, Kaplan A, Sarak B, Biria M, Pillarisetti J, Bhat P, Di Biase L, et al. Incidence of left ventricular function improvement after primary prevention ICD implantation for non-ischaemic dilated cardiomyopathy: a multicentre experience. Heart. 2010;96(7):510–5.CrossRefPubMed
25.
go back to reference Grimm W, Timmesfeld N, Efimova E. Left ventricular function improvement after prophylactic implantable cardioverter-defibrillator implantation in patients with non-ischaemic dilated cardiomyopathy. Europace. 2013;15(11):1594–600.CrossRefPubMed Grimm W, Timmesfeld N, Efimova E. Left ventricular function improvement after prophylactic implantable cardioverter-defibrillator implantation in patients with non-ischaemic dilated cardiomyopathy. Europace. 2013;15(11):1594–600.CrossRefPubMed
26.
go back to reference de Diego C, Gonzalez-Torres L, Nunez JM, Centurion Inda R, Martin-Langerwerf DA, Sangio AD, Chochowski P, Casasnovas P, Blazquez JC, Almendral J. Effects of angiotensin-neprilysin inhibition compared to angiotensin inhibition on ventricular arrhythmias in reduced ejection fraction patients under continuous remote monitoring of implantable defibrillator devices. Heart Rhythm. 2017; https://doi.org/10.1016/j.hrthm.2017.11.012. de Diego C, Gonzalez-Torres L, Nunez JM, Centurion Inda R, Martin-Langerwerf DA, Sangio AD, Chochowski P, Casasnovas P, Blazquez JC, Almendral J. Effects of angiotensin-neprilysin inhibition compared to angiotensin inhibition on ventricular arrhythmias in reduced ejection fraction patients under continuous remote monitoring of implantable defibrillator devices. Heart Rhythm. 2017; https://​doi.​org/​10.​1016/​j.​hrthm.​2017.​11.​012.​
27.
go back to reference Kober L, Thune JJ, Nielsen JC, Haarbo J, Videbaek L, Korup E, Jensen G, Hildebrandt P, Steffensen FH, Bruun NE, et al. Defibrillator implantation in patients with Nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–30.CrossRefPubMed Kober L, Thune JJ, Nielsen JC, Haarbo J, Videbaek L, Korup E, Jensen G, Hildebrandt P, Steffensen FH, Bruun NE, et al. Defibrillator implantation in patients with Nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–30.CrossRefPubMed
28.
go back to reference Kalogeropoulos AP, Fonarow GC, Georgiopoulou V, Burkman G, Siwamogsatham S, Patel A, Li S, Papadimitriou L, Butler J. Characteristics and outcomes of adult outpatients with heart failure and improved or recovered ejection fraction. JAMA Cardiol. 2016;1(5):510–8.CrossRefPubMed Kalogeropoulos AP, Fonarow GC, Georgiopoulou V, Burkman G, Siwamogsatham S, Patel A, Li S, Papadimitriou L, Butler J. Characteristics and outcomes of adult outpatients with heart failure and improved or recovered ejection fraction. JAMA Cardiol. 2016;1(5):510–8.CrossRefPubMed
29.
go back to reference Halliday BP, Cleland JGF, Goldberger JJ, Prasad SK. Personalizing risk stratification for sudden death in dilated cardiomyopathy: the past, present, and future. Circulation. 2017;136(2):215–31.CrossRefPubMed Halliday BP, Cleland JGF, Goldberger JJ, Prasad SK. Personalizing risk stratification for sudden death in dilated cardiomyopathy: the past, present, and future. Circulation. 2017;136(2):215–31.CrossRefPubMed
30.
go back to reference Pontone G, Guaricci AI, Andreini D, Solbiati A, Guglielmo M, Mushtaq S, Baggiano A, Beltrama V, Fusini L, Rota C, et al. Prognostic benefit of cardiac magnetic resonance over transthoracic echocardiography for the assessment of ischemic and Nonischemic dilated cardiomyopathy patients referred for the evaluation of primary prevention implantable cardioverter-defibrillator therapy. Circ Cardiovasc Imaging. 2016;9(10). https://doi.org/10.1161/CIRCIMAGING.115.004956. Pontone G, Guaricci AI, Andreini D, Solbiati A, Guglielmo M, Mushtaq S, Baggiano A, Beltrama V, Fusini L, Rota C, et al. Prognostic benefit of cardiac magnetic resonance over transthoracic echocardiography for the assessment of ischemic and Nonischemic dilated cardiomyopathy patients referred for the evaluation of primary prevention implantable cardioverter-defibrillator therapy. Circ Cardiovasc Imaging. 2016;9(10). https://​doi.​org/​10.​1161/​CIRCIMAGING.​115.​004956.
31.
go back to reference Olde Nordkamp LR, Dabiri Abkenari L, Boersma LV, Maass AH, de Groot JR, van Oostrom AJ, Theuns DA, Jordaens LJ, Wilde AA, Knops RE. The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort. J Am Coll Cardiol. 2012;60(19):1933–9.CrossRefPubMed Olde Nordkamp LR, Dabiri Abkenari L, Boersma LV, Maass AH, de Groot JR, van Oostrom AJ, Theuns DA, Jordaens LJ, Wilde AA, Knops RE. The entirely subcutaneous implantable cardioverter-defibrillator: initial clinical experience in a large Dutch cohort. J Am Coll Cardiol. 2012;60(19):1933–9.CrossRefPubMed
32.
go back to reference Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, Hood M, Kuschyk J, Jones P, et al. Implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol. 2017;70(7):830–41.CrossRefPubMed Boersma L, Barr C, Knops R, Theuns D, Eckardt L, Neuzil P, Scholten M, Hood M, Kuschyk J, Jones P, et al. Implant and midterm outcomes of the subcutaneous implantable cardioverter-defibrillator registry: the EFFORTLESS study. J Am Coll Cardiol. 2017;70(7):830–41.CrossRefPubMed
33.
go back to reference Kuschyk J, Stach K, Tulumen E, Rudic B, Liebe V, Schimpf R, Borggrefe M, Roger S. Subcutaneous implantable cardioverter-defibrillator: first single-center experience with other cardiac implantable electronic devices. Heart Rhythm. 2015;12(11):2230–8.CrossRefPubMed Kuschyk J, Stach K, Tulumen E, Rudic B, Liebe V, Schimpf R, Borggrefe M, Roger S. Subcutaneous implantable cardioverter-defibrillator: first single-center experience with other cardiac implantable electronic devices. Heart Rhythm. 2015;12(11):2230–8.CrossRefPubMed
34.
go back to reference Burke MC, Gold MR, Knight BP, Barr CS, Theuns DA, Boersma LV, Knops RE, Weiss R, Leon AR, Herre JM, et al. Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS registry. J Am Coll Cardiol. 2015;65(16):1605–15.CrossRefPubMed Burke MC, Gold MR, Knight BP, Barr CS, Theuns DA, Boersma LV, Knops RE, Weiss R, Leon AR, Herre JM, et al. Safety and efficacy of the totally subcutaneous implantable defibrillator: 2-year results from a pooled analysis of the IDE study and EFFORTLESS registry. J Am Coll Cardiol. 2015;65(16):1605–15.CrossRefPubMed
Metadata
Title
Therapy optimization in patients with heart failure: the role of the wearable cardioverter-defibrillator in a real-world setting
Authors
Susanne Röger
Stefanie L. Rosenkaimer
Anna Hohneck
Siegfried Lang
Ibrahim El-Battrawy
Boris Rudic
Erol Tülümen
Ksenija Stach
Jürgen Kuschyk
Ibrahim Akin
Martin Borggrefe
Publication date
01-12-2018
Publisher
BioMed Central
Published in
BMC Cardiovascular Disorders / Issue 1/2018
Electronic ISSN: 1471-2261
DOI
https://doi.org/10.1186/s12872-018-0790-8

Other articles of this Issue 1/2018

BMC Cardiovascular Disorders 1/2018 Go to the issue