Skip to main content
Top
Published in: World Journal of Emergency Surgery 1/2014

Open Access 01-12-2014 | Review

Repair of diaphragmatic hernia following spinal surgery by laparoscopic mesh application: a case report and review of the literature

Authors: Roberto Bini, Diego Fontana, Alessandro Longo, Paolo Manconi, Renzo Leli

Published in: World Journal of Emergency Surgery | Issue 1/2014

Login to get access

Abstract

We describe the laparoscopic management of diaphragmatic hernia (DH) caused by vertebral pedicle screw displacement.
A 58-year-old woman underwent surgery for scoliosis and underwent posterior pedicle screw fixation. In the first postoperative (PO)day, she developed mild dyspnea. An anteroposterior chest radiograph revealed bilateral pleural effusion, which was more pronounced on the left side.
A thoracoabdominal computed tomography (CT) scan, performed in the second PO day, revealed a solid mass in the pleural cavity that was associated with screw displacement, which had also entered into the peritoneal cavity without apparent other lesion of hollow and solid viscous. In the third PO day, after the screw was removed, explorative laparoscopy was carried out. We observed herniation of the omentum through a small diaphragmatic tear. Once the absence of visceral injury was confirmed, we reduced the omentum into the abdomen. Then, we repaired the hernia by applying a dual layer polypropylene mesh over the defect with a 3-cm overlap. The remainder of the postoperative period was uneventful.
Iatrogenic DH due to a pedicle screw displacement has never been described before. In cases of pleural effusion following spinal surgery, rapid assessment and treatment are crucial. We conclude that a laparoscopic approach to iatrogenic DH could be feasible and effective in a hemodynamically stable patient with negative CT findings because it enables the completion of the diagnostic cascade and the repair of the tear, providing excellent visualization of the abdominal viscera and diaphragmatic tears.
Appendix
Available only for authorised users
Literature
1.
go back to reference Hicks JM, Singla A, Shen FH, Arlet V: Complications of pedicle screw fixation in scoliosis surgery. A systematic review. Spine. 2010, 35: E465-E470. 10.1097/BRS.0b013e3181d1021a.CrossRefPubMed Hicks JM, Singla A, Shen FH, Arlet V: Complications of pedicle screw fixation in scoliosis surgery. A systematic review. Spine. 2010, 35: E465-E470. 10.1097/BRS.0b013e3181d1021a.CrossRefPubMed
2.
go back to reference Nasser R, Yadla S, Maltenfort MG, Harrop JS, Anderson G, Vaccaro AR, Sharan AD, Ratliff JK: Complications in spine surgery. A review. J Neurosurg Spine. 2010, 13: 144-157. 10.3171/2010.3.SPINE09369. 2010CrossRefPubMed Nasser R, Yadla S, Maltenfort MG, Harrop JS, Anderson G, Vaccaro AR, Sharan AD, Ratliff JK: Complications in spine surgery. A review. J Neurosurg Spine. 2010, 13: 144-157. 10.3171/2010.3.SPINE09369. 2010CrossRefPubMed
3.
go back to reference Levine DS, Dugas JR, Tarantino SJ, Boachie-Adjei O: Chance fracture after pedicle screw fixation. A case report. Spine. 1998, 23: 382-385. 10.1097/00007632-199802010-00019.CrossRefPubMed Levine DS, Dugas JR, Tarantino SJ, Boachie-Adjei O: Chance fracture after pedicle screw fixation. A case report. Spine. 1998, 23: 382-385. 10.1097/00007632-199802010-00019.CrossRefPubMed
4.
go back to reference Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER: Thoracic pedicle screw fixation in spinal deformities: are they really safe?. Spine. 2001, 26: 2049-2057. 10.1097/00007632-200109150-00022.CrossRefPubMed Suk SI, Kim WJ, Lee SM, Kim JH, Chung ER: Thoracic pedicle screw fixation in spinal deformities: are they really safe?. Spine. 2001, 26: 2049-2057. 10.1097/00007632-200109150-00022.CrossRefPubMed
5.
go back to reference Kakkos SK, Shepard AD: Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg. 2008, 47: 1074-1082. 10.1016/j.jvs.2007.11.005.CrossRefPubMed Kakkos SK, Shepard AD: Delayed presentation of aortic injury by pedicle screws: report of two cases and review of the literature. J Vasc Surg. 2008, 47: 1074-1082. 10.1016/j.jvs.2007.11.005.CrossRefPubMed
6.
go back to reference Wegener B, Birkenmaier C, Fottner A, Jansson V, Dürr HR: Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J. 2008, 17S: S351-S354.CrossRef Wegener B, Birkenmaier C, Fottner A, Jansson V, Dürr HR: Delayed perforation of the aorta by a thoracic pedicle screw. Eur Spine J. 2008, 17S: S351-S354.CrossRef
7.
go back to reference Sarlak AY, Tosun B, Atmaca H, Sarisoy HT, Buluç L: Evaluation of thoracic pedicle placement in adolescent idiopathic scoliosis. Eur Spine J. 2009, 18 (12): 1892-1897. 10.1007/s00586-009-1065-y.PubMedCentralCrossRefPubMed Sarlak AY, Tosun B, Atmaca H, Sarisoy HT, Buluç L: Evaluation of thoracic pedicle placement in adolescent idiopathic scoliosis. Eur Spine J. 2009, 18 (12): 1892-1897. 10.1007/s00586-009-1065-y.PubMedCentralCrossRefPubMed
8.
go back to reference Watanabe K, Yamazaki A, Hirano T, Izumi T, Sano A, Morita O, Kikuchi R, Ito T: Descending Aortic injury by a thoracic pedicle screw during posterior reconstructive surgery. A case report. Spine. 2010, 35: E1064-E1068. 10.1097/BRS.0b013e3181ed29c1.CrossRefPubMed Watanabe K, Yamazaki A, Hirano T, Izumi T, Sano A, Morita O, Kikuchi R, Ito T: Descending Aortic injury by a thoracic pedicle screw during posterior reconstructive surgery. A case report. Spine. 2010, 35: E1064-E1068. 10.1097/BRS.0b013e3181ed29c1.CrossRefPubMed
9.
go back to reference Heini P, Schöll E, Wyler D, Eggli S: Fatal cardiac tamponade associated with posterior spinal instrumentation: a case report. Spine. 1998, 23: 2226-2230. 10.1097/00007632-199810150-00017.CrossRefPubMed Heini P, Schöll E, Wyler D, Eggli S: Fatal cardiac tamponade associated with posterior spinal instrumentation: a case report. Spine. 1998, 23: 2226-2230. 10.1097/00007632-199810150-00017.CrossRefPubMed
10.
go back to reference di Silvestre M, Parisini P, Lolli F, Bakaloudis G: Complications of thoracic pedicle screws in scoliosis treatment. Spine. 2007, 32: 1655-1665. 10.1097/BRS.0b013e318074d604.CrossRefPubMed di Silvestre M, Parisini P, Lolli F, Bakaloudis G: Complications of thoracic pedicle screws in scoliosis treatment. Spine. 2007, 32: 1655-1665. 10.1097/BRS.0b013e318074d604.CrossRefPubMed
11.
go back to reference Minor ME, Morrissey NJ, Peress R, Carroccio A, Ellozy S, Agarwal G, Teodorescu V, Hollier LH, Marin ML: Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg. 2004, 39: 893-896. 10.1016/j.jvs.2003.10.056.CrossRefPubMed Minor ME, Morrissey NJ, Peress R, Carroccio A, Ellozy S, Agarwal G, Teodorescu V, Hollier LH, Marin ML: Endovascular treatment of an iatrogenic thoracic aortic injury after spinal instrumentation: case report. J Vasc Surg. 2004, 39: 893-896. 10.1016/j.jvs.2003.10.056.CrossRefPubMed
12.
go back to reference Choi JB, Han JO, Jeong JW: False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma. 2001, 50: 140-143. 10.1097/00005373-200101000-00029.CrossRefPubMed Choi JB, Han JO, Jeong JW: False aneurysm of the thoracic aorta associated with an aorto-chest wall fistula after spinal instrumentation. J Trauma. 2001, 50: 140-143. 10.1097/00005373-200101000-00029.CrossRefPubMed
13.
go back to reference Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M: Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J. 1999, 8: 156-160. 10.1007/s005860050147.PubMedCentralCrossRefPubMed Papin P, Arlet V, Marchesi D, Rosenblatt B, Aebi M: Unusual presentation of spinal cord compression related to misplaced pedicle screws in thoracic scoliosis. Eur Spine J. 1999, 8: 156-160. 10.1007/s005860050147.PubMedCentralCrossRefPubMed
14.
go back to reference Larici AR, Gotway MB, Litt HI, Gautham PR, Reddy GP, Webb WR, Gotway CA, Dawn SK, Marder SR, Storto ML: Helical CT with sagittal and coronal reconstructions: Accuracy for detection of diaphragmatic injury. AJR. 2002, 179: 451-457. 10.2214/ajr.179.2.1790451.CrossRefPubMed Larici AR, Gotway MB, Litt HI, Gautham PR, Reddy GP, Webb WR, Gotway CA, Dawn SK, Marder SR, Storto ML: Helical CT with sagittal and coronal reconstructions: Accuracy for detection of diaphragmatic injury. AJR. 2002, 179: 451-457. 10.2214/ajr.179.2.1790451.CrossRefPubMed
15.
go back to reference Slim K, Bousquet J, Chipponi J: Laparoscopic repair of missed blunt diaphragmatic rupture using a prosthesis. Surg Endosc. 1998, 12: 1358-1360. 10.1007/s004649900857.CrossRefPubMed Slim K, Bousquet J, Chipponi J: Laparoscopic repair of missed blunt diaphragmatic rupture using a prosthesis. Surg Endosc. 1998, 12: 1358-1360. 10.1007/s004649900857.CrossRefPubMed
16.
go back to reference Reyad AG, Ahmed I, Bosanac Z, Philips S: Successful laparoscopic repair of acute intrapericardial diaphragmatic hernia secondary to penetrating trauma. J Trauma. 2009, 67: E181-E183. 10.1097/TA.0b013e31809fef31.CrossRef Reyad AG, Ahmed I, Bosanac Z, Philips S: Successful laparoscopic repair of acute intrapericardial diaphragmatic hernia secondary to penetrating trauma. J Trauma. 2009, 67: E181-E183. 10.1097/TA.0b013e31809fef31.CrossRef
17.
go back to reference Hanna WC, Ferri LE, Fata P, Razek T, Mulder DS: The current status of traumatic diaphragmatic injury: lessons learned from 105 patients over 13 years. Ann Thorac Surg. 2008, 85: 1044-1048. 10.1016/j.athoracsur.2007.10.084.CrossRefPubMed Hanna WC, Ferri LE, Fata P, Razek T, Mulder DS: The current status of traumatic diaphragmatic injury: lessons learned from 105 patients over 13 years. Ann Thorac Surg. 2008, 85: 1044-1048. 10.1016/j.athoracsur.2007.10.084.CrossRefPubMed
18.
go back to reference Amid PK: Classification of biomaterials and their related complications in abdominal wall surgery. Hernia. 1997, 1: 15-21. 10.1007/BF02426382.CrossRef Amid PK: Classification of biomaterials and their related complications in abdominal wall surgery. Hernia. 1997, 1: 15-21. 10.1007/BF02426382.CrossRef
19.
go back to reference Rashid F, Chakrabarty MM, Singh R, Iftikhar SY: A review on delayed presentation of diaphragmatic rupture. World J Emerg Surg. 2009, 4: 32-10.1186/1749-7922-4-32.PubMedCentralCrossRefPubMed Rashid F, Chakrabarty MM, Singh R, Iftikhar SY: A review on delayed presentation of diaphragmatic rupture. World J Emerg Surg. 2009, 4: 32-10.1186/1749-7922-4-32.PubMedCentralCrossRefPubMed
20.
go back to reference Paul S, Nasar A, Port JL, Lee PC, Stiles BC, Nguyen AB, Altorki NK, Sedrakyan A: Comparative analysis of diaphragmatic hernia repair outcomes using the nationwide inpatient sample database. Arch Surg. 2012, 147: 607-612.CrossRefPubMed Paul S, Nasar A, Port JL, Lee PC, Stiles BC, Nguyen AB, Altorki NK, Sedrakyan A: Comparative analysis of diaphragmatic hernia repair outcomes using the nationwide inpatient sample database. Arch Surg. 2012, 147: 607-612.CrossRefPubMed
Metadata
Title
Repair of diaphragmatic hernia following spinal surgery by laparoscopic mesh application: a case report and review of the literature
Authors
Roberto Bini
Diego Fontana
Alessandro Longo
Paolo Manconi
Renzo Leli
Publication date
01-12-2014
Publisher
BioMed Central
Published in
World Journal of Emergency Surgery / Issue 1/2014
Electronic ISSN: 1749-7922
DOI
https://doi.org/10.1186/1749-7922-9-34

Other articles of this Issue 1/2014

World Journal of Emergency Surgery 1/2014 Go to the issue