Skip to main content
Top
Published in: World Journal of Surgical Oncology 1/2014

Open Access 01-12-2014 | Research

Accuracy of 16/18G core needle biopsy for ultrasound-visible breast lesions

Authors: Jie-Ying Zhou, Jie Tang, Zhi-Li Wang, Fa-Qin Lv, Yu-Kun Luo, Hong-Zhen Qin, Mei Liu

Published in: World Journal of Surgical Oncology | Issue 1/2014

Login to get access

Abstract

Background

To assess the accuracy of ultrasound-guided 16G or 18G core needle biopsy (CNB) for ultrasound-visible breast lesions, and to analyze the effects of lesion features.

Methods

Between July 2005 and July 2012, 4,453 ultrasound-detected breast lesions underwent ultrasound-guided CNB and were retrospectively reviewed. Surgical excision was performed for 955 lesions (566 with 16G CNB and 389 with 18G CNB) which constitute the basis of the study. Histological findings were compared between the ultrasound-guided CNB and the surgical excision to determine sensitivity, false-negative rate, agreement rate, and underestimation rate, according to different lesion features.

Results

Final pathological results were malignant in 84.1% (invasive carcinoma, ductal carcinoma in situ, lymphoma, and metastases), high-risk in 8.4% (atypical lesions, papillary lesions, and phyllodes tumors), and benign in 7.5%. False-negative rates were 1.4% for 16G and 18G CNB. Agreement rates between histological findings of CNB and surgery were 92.4% for 16G and 92.8% for 18G CNB. Overall underestimate rates (high-risk CNB becoming malignant on surgery and ductal carcinoma in situ becoming invasive carcinoma) were 47.4% for 16G and 48.9% for 18G CNB. Agreements were better for mass lesions (16G: 92.7%; 18G: 93.7%) than for non-mass lesions (16G, 85.7%; 18G, 78.3%) (P <0.01). For mass lesions with a diameter ≤10 mm, the agreement rates (16G, 83.3%; 18G, 86.7%) were lower (P <0.01).

Conclusions

Ultrasound-guided 16G and 18G CNB are accurate for evaluating ultrasound-visible breast mass lesions with a diameter >10 mm.
Literature
1.
go back to reference Parker SH: Percutaneous large core breast biopsy. Cancer. 1994, 74: 256-262. 10.1002/cncr.2820741309.CrossRefPubMed Parker SH: Percutaneous large core breast biopsy. Cancer. 1994, 74: 256-262. 10.1002/cncr.2820741309.CrossRefPubMed
2.
go back to reference O’Flynn EA, Wilson AR, Michell MJ: Image-guided breast biopsy: state-of-the-art. Clin Radiol. 2010, 65: 259-270. 10.1016/j.crad.2010.01.008.CrossRefPubMed O’Flynn EA, Wilson AR, Michell MJ: Image-guided breast biopsy: state-of-the-art. Clin Radiol. 2010, 65: 259-270. 10.1016/j.crad.2010.01.008.CrossRefPubMed
3.
go back to reference Levin DC, Parker L, Schwartz GF, Rao VM: Percutaneous needle vs surgical breast biopsy: previous allegations of overuse of surgery are in error. J Am Coll Radiol. 2012, 9: 137-140. 10.1016/j.jacr.2011.10.002.CrossRefPubMed Levin DC, Parker L, Schwartz GF, Rao VM: Percutaneous needle vs surgical breast biopsy: previous allegations of overuse of surgery are in error. J Am Coll Radiol. 2012, 9: 137-140. 10.1016/j.jacr.2011.10.002.CrossRefPubMed
4.
go back to reference Nath ME, Robinson TM, Tobon H, Chough DM, Sumkin JH: Automated large-core needle biopsy of surgically removed breast lesions: comparison of samples obtained with 14-, 16-, and 18-gauge needles. Radiology. 1995, 197: 739-742.CrossRefPubMed Nath ME, Robinson TM, Tobon H, Chough DM, Sumkin JH: Automated large-core needle biopsy of surgically removed breast lesions: comparison of samples obtained with 14-, 16-, and 18-gauge needles. Radiology. 1995, 197: 739-742.CrossRefPubMed
5.
go back to reference Helbich TH, Rudas M, Haitel A, Kohlberger PD, Thurnher M, Gnant M, Wunderbaldinger P, Wolf G, Mostbeck GH: Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol. 1998, 171: 59-63. 10.2214/ajr.171.1.9648764.CrossRefPubMed Helbich TH, Rudas M, Haitel A, Kohlberger PD, Thurnher M, Gnant M, Wunderbaldinger P, Wolf G, Mostbeck GH: Evaluation of needle size for breast biopsy: comparison of 14-, 16-, and 18-gauge biopsy needles. AJR Am J Roentgenol. 1998, 171: 59-63. 10.2214/ajr.171.1.9648764.CrossRefPubMed
6.
go back to reference Uematsu T: How to choose needles and probes for ultrasonographically guided percutaneous breast biopsy: a systematic approach. Breast Cancer. 2012, 19: 238-241. 10.1007/s12282-012-0340-7.CrossRefPubMed Uematsu T: How to choose needles and probes for ultrasonographically guided percutaneous breast biopsy: a systematic approach. Breast Cancer. 2012, 19: 238-241. 10.1007/s12282-012-0340-7.CrossRefPubMed
7.
go back to reference Mai J, Yong J, Dixson H, Makris A, Aravindan A, Suranyi MG, Wong J: Is bigger better? A retrospective analysis of native renal biopsies with 16 Gauge versus 18 Gauge automatic needles. Nephrology (Carlton). 2013, 18: 525-530. 10.1111/nep.12093.CrossRef Mai J, Yong J, Dixson H, Makris A, Aravindan A, Suranyi MG, Wong J: Is bigger better? A retrospective analysis of native renal biopsies with 16 Gauge versus 18 Gauge automatic needles. Nephrology (Carlton). 2013, 18: 525-530. 10.1111/nep.12093.CrossRef
8.
go back to reference Parker SH, Burbank F, Jackman RJ, Aucreman CJ, Cardenosa G, Cink TM, Coscia JL, Eklund GW, Evans WP, Garver PR: Percutaneous large-core breast biopsy: a multi-institutional study. Radiology. 1994, 193: 359-364.CrossRefPubMed Parker SH, Burbank F, Jackman RJ, Aucreman CJ, Cardenosa G, Cink TM, Coscia JL, Eklund GW, Evans WP, Garver PR: Percutaneous large-core breast biopsy: a multi-institutional study. Radiology. 1994, 193: 359-364.CrossRefPubMed
9.
go back to reference Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF: US-guided core breast biopsy: use and cost-effectiveness. Radiology. 1998, 208: 717-723.CrossRefPubMed Liberman L, Feng TL, Dershaw DD, Morris EA, Abramson AF: US-guided core breast biopsy: use and cost-effectiveness. Radiology. 1998, 208: 717-723.CrossRefPubMed
10.
go back to reference Smith DN, Rosenfield Darling ML, Meyer JE, Denison CM, Rose DI, Lester S, Richardson A, Kaelin CM, Rhei E, Christian RL: The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med. 2001, 20: 43-49.PubMed Smith DN, Rosenfield Darling ML, Meyer JE, Denison CM, Rose DI, Lester S, Richardson A, Kaelin CM, Rhei E, Christian RL: The utility of ultrasonographically guided large-core needle biopsy: results from 500 consecutive breast biopsies. J Ultrasound Med. 2001, 20: 43-49.PubMed
11.
go back to reference Schoonjans JM, Brem RF: Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses. J Ultrasound Med. 2001, 20: 967-972.PubMed Schoonjans JM, Brem RF: Fourteen-gauge ultrasonographically guided large-core needle biopsy of breast masses. J Ultrasound Med. 2001, 20: 967-972.PubMed
12.
go back to reference Memarsadeghi M, Pfarl G, Riedl C, Wagner T, Rudas M, Helbich TH: Value of 14-gauge ultrasound-guided large-core needle biopsy of breast lesions: own results in comparison with the literature. Rofo. 2003, 175: 374-380. 10.1055/s-2003-37822.CrossRefPubMed Memarsadeghi M, Pfarl G, Riedl C, Wagner T, Rudas M, Helbich TH: Value of 14-gauge ultrasound-guided large-core needle biopsy of breast lesions: own results in comparison with the literature. Rofo. 2003, 175: 374-380. 10.1055/s-2003-37822.CrossRefPubMed
13.
go back to reference Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S: Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound. 2005, 33: 47-52. 10.1002/jcu.20089.CrossRefPubMed Crystal P, Koretz M, Shcharynsky S, Makarov V, Strano S: Accuracy of sonographically guided 14-gauge core-needle biopsy: results of 715 consecutive breast biopsies with at least two-year follow-up of benign lesions. J Clin Ultrasound. 2005, 33: 47-52. 10.1002/jcu.20089.CrossRefPubMed
14.
go back to reference Sauer G, Deissler H, Strunz K, Helms G, Remmel E, Koretz K, Terinde R, Kreienberg R: Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification. Br J Cancer. 2005, 92: 231-235.PubMedCentralPubMed Sauer G, Deissler H, Strunz K, Helms G, Remmel E, Koretz K, Terinde R, Kreienberg R: Ultrasound-guided large-core needle biopsies of breast lesions: analysis of 962 cases to determine the number of samples for reliable tumour classification. Br J Cancer. 2005, 92: 231-235.PubMedCentralPubMed
15.
go back to reference De Lucena CE, Dos Santos Junior JL, De Lima Resende CA, Do Amaral VF, De Almeida Barra A, Reis JH: Ultrasound-guided core needle biopsy of breast masses: How many cores are necessary to diagnose cancer?. J Clin Ultrasound. 2007, 35: 363-366. 10.1002/jcu.20380.CrossRefPubMed De Lucena CE, Dos Santos Junior JL, De Lima Resende CA, Do Amaral VF, De Almeida Barra A, Reis JH: Ultrasound-guided core needle biopsy of breast masses: How many cores are necessary to diagnose cancer?. J Clin Ultrasound. 2007, 35: 363-366. 10.1002/jcu.20380.CrossRefPubMed
16.
go back to reference Schueller G, Jaromi S, Ponhold L, Fuchsjaeger M, Memarsadeghi M, Rudas M, Weber M, Liberman L, Helbich TH: US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases. Radiology. 2008, 248: 406-413. 10.1148/radiol.2482071994.CrossRefPubMed Schueller G, Jaromi S, Ponhold L, Fuchsjaeger M, Memarsadeghi M, Rudas M, Weber M, Liberman L, Helbich TH: US-guided 14-gauge core-needle breast biopsy: results of a validation study in 1352 cases. Radiology. 2008, 248: 406-413. 10.1148/radiol.2482071994.CrossRefPubMed
17.
go back to reference Youk JH, Kim EK, Kim MJ, Kwak JY, Son EJ: Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy. Eur Radiol. 2010, 20: 782-789. 10.1007/s00330-009-1632-y.CrossRefPubMed Youk JH, Kim EK, Kim MJ, Kwak JY, Son EJ: Analysis of false-negative results after US-guided 14-gauge core needle breast biopsy. Eur Radiol. 2010, 20: 782-789. 10.1007/s00330-009-1632-y.CrossRefPubMed
18.
go back to reference Povoski SP, Jimenez RE, Wang WP: Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach. World J Surg Oncol. 2011, 9: 87-10.1186/1477-7819-9-87.PubMedCentralCrossRefPubMed Povoski SP, Jimenez RE, Wang WP: Ultrasound-guided diagnostic breast biopsy methodology: retrospective comparison of the 8-gauge vacuum-assisted biopsy approach versus the spring-loaded 14-gauge core biopsy approach. World J Surg Oncol. 2011, 9: 87-10.1186/1477-7819-9-87.PubMedCentralCrossRefPubMed
19.
go back to reference Uematsu T: Non-mass-like lesions on breast ultrasonography: a systematic review. Breast Cancer. 2012, 19: 295-301. 10.1007/s12282-012-0364-z.CrossRefPubMed Uematsu T: Non-mass-like lesions on breast ultrasonography: a systematic review. Breast Cancer. 2012, 19: 295-301. 10.1007/s12282-012-0364-z.CrossRefPubMed
20.
go back to reference Youk JH, Kim EK, Kim MJ, Oh KK: Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up. AJR Am J Roentgenol. 2008, 190: 202-207. 10.2214/AJR.07.2419.CrossRefPubMed Youk JH, Kim EK, Kim MJ, Oh KK: Sonographically guided 14-gauge core needle biopsy of breast masses: a review of 2,420 cases with long-term follow-up. AJR Am J Roentgenol. 2008, 190: 202-207. 10.2214/AJR.07.2419.CrossRefPubMed
21.
go back to reference Schueller G, Schueller-Weidekamm C, Helbich TH: Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol. 2008, 18: 1761-1773. 10.1007/s00330-008-0955-4.CrossRefPubMed Schueller G, Schueller-Weidekamm C, Helbich TH: Accuracy of ultrasound-guided, large-core needle breast biopsy. Eur Radiol. 2008, 18: 1761-1773. 10.1007/s00330-008-0955-4.CrossRefPubMed
22.
23.
go back to reference Alagaratnam TT, Wong J: Limitations of mammography in Chinese females. Clin Radiol. 1985, 36: 175-177. 10.1016/S0009-9260(85)80104-5.CrossRefPubMed Alagaratnam TT, Wong J: Limitations of mammography in Chinese females. Clin Radiol. 1985, 36: 175-177. 10.1016/S0009-9260(85)80104-5.CrossRefPubMed
24.
go back to reference Zheng S, Bai JQ, Li J, Fan JH, Pang Y, Song QK, Huang R, Yang HJ, Xu F, Lu N, Qiao YL: The pathologic characteristics of breast cancer in China and its shift during 1999–2008: a national-wide multicenter cross-sectional image over 10 years. Int J Cancer. 2012, 131: 2622-2631. 10.1002/ijc.27513.CrossRefPubMed Zheng S, Bai JQ, Li J, Fan JH, Pang Y, Song QK, Huang R, Yang HJ, Xu F, Lu N, Qiao YL: The pathologic characteristics of breast cancer in China and its shift during 1999–2008: a national-wide multicenter cross-sectional image over 10 years. Int J Cancer. 2012, 131: 2622-2631. 10.1002/ijc.27513.CrossRefPubMed
25.
go back to reference Li J, Zhang BN, Fan JH, Pang Y, Zhang P, Wang SL, Zheng S, Zhang B, Yang HJ, Xie XM, Tang ZH, Li H, Li JY, He JJ Qiao YL: A nation-wide multicenter 10-year (1999–2008) retrospective clinical epidemiological study of female breast cancer in China. BMC Cancer. 2011, 11: 364-10.1186/1471-2407-11-364.PubMedCentralCrossRefPubMed Li J, Zhang BN, Fan JH, Pang Y, Zhang P, Wang SL, Zheng S, Zhang B, Yang HJ, Xie XM, Tang ZH, Li H, Li JY, He JJ Qiao YL: A nation-wide multicenter 10-year (1999–2008) retrospective clinical epidemiological study of female breast cancer in China. BMC Cancer. 2011, 11: 364-10.1186/1471-2407-11-364.PubMedCentralCrossRefPubMed
26.
go back to reference Osako T, Takahashi K, Iwase T, Iijima K, Miyagi Y, Nishimura S, Tada K, Makita M, Akiyama F, Sakamoto G, Kasumi F: Diagnostic ultrasonography and mammography for invasive and noninvasive breast cancer in women aged 30 to 39 years. Breast Cancer. 2007, 14: 229-233. 10.2325/jbcs.891.CrossRefPubMed Osako T, Takahashi K, Iwase T, Iijima K, Miyagi Y, Nishimura S, Tada K, Makita M, Akiyama F, Sakamoto G, Kasumi F: Diagnostic ultrasonography and mammography for invasive and noninvasive breast cancer in women aged 30 to 39 years. Breast Cancer. 2007, 14: 229-233. 10.2325/jbcs.891.CrossRefPubMed
27.
go back to reference Verkooijen HM, Peeters PH, Buskens E, Koot VC, Borel Rinkes IH, Mali WP, Van Vroonhoven TJ: Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer. 2000, 82: 1017-1021.PubMedCentralCrossRefPubMed Verkooijen HM, Peeters PH, Buskens E, Koot VC, Borel Rinkes IH, Mali WP, Van Vroonhoven TJ: Diagnostic accuracy of large-core needle biopsy for nonpalpable breast disease: a meta-analysis. Br J Cancer. 2000, 82: 1017-1021.PubMedCentralCrossRefPubMed
28.
go back to reference Youk JH, Kim EK, Kim MJ: Atypical ductal hyperplasia diagnosed at sonographically guided 14-gauge core needle biopsy of breast mass. AJR Am J Roentgenol. 2009, 192: 1135-1141. 10.2214/AJR.08.1144.CrossRefPubMed Youk JH, Kim EK, Kim MJ: Atypical ductal hyperplasia diagnosed at sonographically guided 14-gauge core needle biopsy of breast mass. AJR Am J Roentgenol. 2009, 192: 1135-1141. 10.2214/AJR.08.1144.CrossRefPubMed
29.
go back to reference Deshaies I, Provencher L, Jacob S, Cote G, Robert J, Desbiens C, Poirier B, Hogue JC, Vachon E, Diorio C: Factors associated with upgrading to malignancy at surgery of atypical ductal hyperplasia diagnosed on core biopsy. Breast. 2010, 20: 50-55.CrossRefPubMed Deshaies I, Provencher L, Jacob S, Cote G, Robert J, Desbiens C, Poirier B, Hogue JC, Vachon E, Diorio C: Factors associated with upgrading to malignancy at surgery of atypical ductal hyperplasia diagnosed on core biopsy. Breast. 2010, 20: 50-55.CrossRefPubMed
30.
go back to reference Stoblen F, Landt S, Ishaq R, Stelkens-Gebhardt R, Rezai M, Skaane P, Blohmer JU, Sehouli J, Kummel S: High-frequency breast ultrasound for the detection of microcalcifications and associated masses in BI-RADS 4a patients. Anticancer Res. 2011, 31: 2575-2581.PubMed Stoblen F, Landt S, Ishaq R, Stelkens-Gebhardt R, Rezai M, Skaane P, Blohmer JU, Sehouli J, Kummel S: High-frequency breast ultrasound for the detection of microcalcifications and associated masses in BI-RADS 4a patients. Anticancer Res. 2011, 31: 2575-2581.PubMed
31.
go back to reference Wang ZL, Liu G, Li JL, Su L, Liu XJ, Wang W, Tang J: Breast lesions with imaging-histologic discordance during 16-gauge core needle biopsy system: would vacuum-assisted removal get significantly more definitive histologic diagnosis than vacuum-assisted biopsy?. Breast J. 2011, 17: 456-461. 10.1111/j.1524-4741.2011.01128.x.CrossRefPubMed Wang ZL, Liu G, Li JL, Su L, Liu XJ, Wang W, Tang J: Breast lesions with imaging-histologic discordance during 16-gauge core needle biopsy system: would vacuum-assisted removal get significantly more definitive histologic diagnosis than vacuum-assisted biopsy?. Breast J. 2011, 17: 456-461. 10.1111/j.1524-4741.2011.01128.x.CrossRefPubMed
32.
go back to reference Parker SH, Jobe WE, Dennis MA, Stavros AT, Johnson KK, Yakes WF, Truell JE, Price JG, Kortz AB, Clark DG: US-guided automated large-core breast biopsy. Radiology. 1993, 187: 507-511.CrossRefPubMed Parker SH, Jobe WE, Dennis MA, Stavros AT, Johnson KK, Yakes WF, Truell JE, Price JG, Kortz AB, Clark DG: US-guided automated large-core breast biopsy. Radiology. 1993, 187: 507-511.CrossRefPubMed
33.
go back to reference Dillon MF, Hill ADK, Quinn CM, O’Doherty A, McDermott EW, O’Higgins N: The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases. Ann Surg. 2005, 242: 701-707. 10.1097/01.sla.0000186186.05971.e0.PubMedCentralCrossRefPubMed Dillon MF, Hill ADK, Quinn CM, O’Doherty A, McDermott EW, O’Higgins N: The accuracy of ultrasound, stereotactic, and clinical core biopsies in the diagnosis of breast cancer, with an analysis of false-negative cases. Ann Surg. 2005, 242: 701-707. 10.1097/01.sla.0000186186.05971.e0.PubMedCentralCrossRefPubMed
Metadata
Title
Accuracy of 16/18G core needle biopsy for ultrasound-visible breast lesions
Authors
Jie-Ying Zhou
Jie Tang
Zhi-Li Wang
Fa-Qin Lv
Yu-Kun Luo
Hong-Zhen Qin
Mei Liu
Publication date
01-12-2014
Publisher
BioMed Central
Published in
World Journal of Surgical Oncology / Issue 1/2014
Electronic ISSN: 1477-7819
DOI
https://doi.org/10.1186/1477-7819-12-7

Other articles of this Issue 1/2014

World Journal of Surgical Oncology 1/2014 Go to the issue