Skip to main content
Top
Published in: BMC Gastroenterology 1/2012

Open Access 01-12-2012 | Research article

Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope

Authors: Qin Xie, Bin Chen, Liu Liu, Huatian Gan

Published in: BMC Gastroenterology | Issue 1/2012

Login to get access

Abstract

Background

The variable-stiffness colonoscope (VSC) appears to have advantages over the standard adult colonoscope (SAC), although data are conflicting. To provide a comprehensive up-to-date review, we conducted a meta-analysis to compare the efficacies of the VSC and SAC.

Methods

Electronic databases, including PubMed, EMBASE, the Cochrane library and the Science Citation Index, were searched to retrieve relevant trials. In addition, meeting abstracts and the reference lists of retrieved articles were reviewed for further relevant studies.

Results

Eight randomized controlled trials (RCTs), enrolling a total of 2033 patients, were included in the meta-analysis. There was no significant heterogeneity among these studies. The cecal intubation rate was higher with the use of VSC (RR = 1.03, 95% CI 1.01 to 1.06, 8 RCTs). The VSC was also associated with fewer position changes made during colonoscopy. Time to cecal intubation was similar with VSC and SAC (WMD −0.54, 95% CI −1.40 to 0.32) but shorter in subgroup analysis with the use of VSC (WMD = −1.36, 95% CI −2.29 to −0.43). Sedation dose used with the two types of instruments showed no evidence of differences either. For all trials, only patients were blinded because of the nature of the interventions.

Conclusion

Use of the VSC significantly improved the cecal intubation rate and reduced ancillary maneuvers made during the procedure. Cecal intubation time was similar for the two colonoscope types over all trials, whereas a shortened time with the use of the adult VSC was seen in subgroup analysis.
Appendix
Available only for authorised users
Literature
1.
go back to reference Church JM: Complete colonoscopy: how often? And if not, why not?. Am J Gastroenterol. 1994, 89: 556-560.PubMed Church JM: Complete colonoscopy: how often? And if not, why not?. Am J Gastroenterol. 1994, 89: 556-560.PubMed
2.
go back to reference Mitchell RM, McCallion K, Gardiner KR, Watson RG, Collins JS: Successful colonoscopy; completion rates and reasons for incompletion. Ulster Med J. 2002, 71: 34-37.PubMedPubMedCentral Mitchell RM, McCallion K, Gardiner KR, Watson RG, Collins JS: Successful colonoscopy; completion rates and reasons for incompletion. Ulster Med J. 2002, 71: 34-37.PubMedPubMedCentral
3.
go back to reference Cardin F, Minicuci N, Andreotti A, Pinetti E, Campigotto F, Don BM, Martella B, Terranova O: Mximizing the general success of cecal intubation during propofol sedation in a multi-endoscopist academic center. BMC Gastroenterol. 2010, 10: 123-10.1186/1471-230X-10-123.CrossRefPubMedPubMedCentral Cardin F, Minicuci N, Andreotti A, Pinetti E, Campigotto F, Don BM, Martella B, Terranova O: Mximizing the general success of cecal intubation during propofol sedation in a multi-endoscopist academic center. BMC Gastroenterol. 2010, 10: 123-10.1186/1471-230X-10-123.CrossRefPubMedPubMedCentral
4.
go back to reference Ginsberg GG: Colonoscopy with the variable stiffness colonoscope. Gastrointest Endosc. 2003, 58: 579-584. 10.1067/S0016-5107(03)01873-X.CrossRefPubMed Ginsberg GG: Colonoscopy with the variable stiffness colonoscope. Gastrointest Endosc. 2003, 58: 579-584. 10.1067/S0016-5107(03)01873-X.CrossRefPubMed
5.
go back to reference Rodriguez SA, Ormseth E, Tsuchida A: Bowel perforation with the variable stiffness colonoscope. Gastrointest Endosc. 2003, 57: 271-273. 10.1067/mge.2003.58.CrossRefPubMed Rodriguez SA, Ormseth E, Tsuchida A: Bowel perforation with the variable stiffness colonoscope. Gastrointest Endosc. 2003, 57: 271-273. 10.1067/mge.2003.58.CrossRefPubMed
6.
go back to reference Odori T, Goto H, Arisawa T, Niwa Y, Ohimiya N, Hayakawa T: Clinical results and development of variable-stiffness video colonoscopes. Endoscopy. 2001, 33: 65-69. 10.1055/s-2001-11174.CrossRefPubMed Odori T, Goto H, Arisawa T, Niwa Y, Ohimiya N, Hayakawa T: Clinical results and development of variable-stiffness video colonoscopes. Endoscopy. 2001, 33: 65-69. 10.1055/s-2001-11174.CrossRefPubMed
7.
go back to reference Shah SG, Brooker JC, Williams CB, Thaper C, Suzuki N, Saunders BP: The variable stiffness colonoscope:assessment of efficacy by magnetic endoscope imaging. Gastrointest Endosc. 2002, 56: 195-210.CrossRefPubMed Shah SG, Brooker JC, Williams CB, Thaper C, Suzuki N, Saunders BP: The variable stiffness colonoscope:assessment of efficacy by magnetic endoscope imaging. Gastrointest Endosc. 2002, 56: 195-210.CrossRefPubMed
8.
go back to reference Rex DK: Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients. Endoscopy. 2001, 33: 60-64. 10.1055/s-2001-11179.CrossRefPubMed Rex DK: Effect of variable stiffness colonoscopes on cecal intubation times for routine colonoscopy by an experienced examiner in sedated patients. Endoscopy. 2001, 33: 60-64. 10.1055/s-2001-11179.CrossRefPubMed
9.
go back to reference Kaffes AJ, Mishra A, Ding SL, Hope R, Williams SJ, Gillespie PE: Bourke MJ.A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy. Gastrointest Endosc. 2003, 58: 685-689. 10.1016/S0016-5107(03)02017-0.CrossRefPubMed Kaffes AJ, Mishra A, Ding SL, Hope R, Williams SJ, Gillespie PE: Bourke MJ.A prospective trial of variable stiffness pediatric vs. standard instrument colonoscopy. Gastrointest Endosc. 2003, 58: 685-689. 10.1016/S0016-5107(03)02017-0.CrossRefPubMed
10.
go back to reference Baron TH: The variable stiffness colonoscope:A scope for all reasons?. Am J Gastroenterol. 2002, 97: 2942-2943. 10.1111/j.1572-0241.2002.07091.x.CrossRefPubMed Baron TH: The variable stiffness colonoscope:A scope for all reasons?. Am J Gastroenterol. 2002, 97: 2942-2943. 10.1111/j.1572-0241.2002.07091.x.CrossRefPubMed
11.
go back to reference Othman MO, Bradley AG, Choudhary A, Hoffman RM, Roy PK: Variable stiffness colonoscope versus regular adult colonoscope: meta-analysis of randomized controlled trials. Endoscopy. 2009, 41: 17-24. 10.1055/s-0028-1103488.CrossRefPubMed Othman MO, Bradley AG, Choudhary A, Hoffman RM, Roy PK: Variable stiffness colonoscope versus regular adult colonoscope: meta-analysis of randomized controlled trials. Endoscopy. 2009, 41: 17-24. 10.1055/s-0028-1103488.CrossRefPubMed
12.
go back to reference Martinez JL, Calleja JL: A new variable stiffness colonoscope makes colonoscopy easier: a randomized controlled trial. Gastrointest Endosc. 2001, 53 (6): 694-695.PubMed Martinez JL, Calleja JL: A new variable stiffness colonoscope makes colonoscopy easier: a randomized controlled trial. Gastrointest Endosc. 2001, 53 (6): 694-695.PubMed
13.
go back to reference Saunders BP, East JE: What are the benefits of the variable stiffness colonoscope?. Nat Clin Pract Gastroenterol Hepatol. 2008, 5 (1): 8-9.CrossRefPubMed Saunders BP, East JE: What are the benefits of the variable stiffness colonoscope?. Nat Clin Pract Gastroenterol Hepatol. 2008, 5 (1): 8-9.CrossRefPubMed
14.
go back to reference Saunder BP, Williams CB: The variable-stiffness colonoscope:”too stiff or not too stiff, that is the question:– a new twist to the plot. Endoscopy. 2001, 33 (1): 70-73. 10.1055/s-2001-11180.CrossRef Saunder BP, Williams CB: The variable-stiffness colonoscope:”too stiff or not too stiff, that is the question:– a new twist to the plot. Endoscopy. 2001, 33 (1): 70-73. 10.1055/s-2001-11180.CrossRef
16.
go back to reference Subramanian S, Rex DK: Variable stiffness colonoscopes: do they offer a better examination?. Curr Opin Gastroenterol. 2003, 19 (5): 492-496. 10.1097/00001574-200309000-00011.CrossRefPubMed Subramanian S, Rex DK: Variable stiffness colonoscopes: do they offer a better examination?. Curr Opin Gastroenterol. 2003, 19 (5): 492-496. 10.1097/00001574-200309000-00011.CrossRefPubMed
17.
go back to reference Shah SG, Saunders BP: Aids to insertion:magnetic imaging, variable stiffness, and overtubes. Gastrointest Endosc Clin N Am. 2005, 15 (4): 673-686. 10.1016/j.giec.2005.08.011.CrossRefPubMed Shah SG, Saunders BP: Aids to insertion:magnetic imaging, variable stiffness, and overtubes. Gastrointest Endosc Clin N Am. 2005, 15 (4): 673-686. 10.1016/j.giec.2005.08.011.CrossRefPubMed
18.
go back to reference Leung FW: Methods of reducing discomfort during colonoscopy. Dig Dis Sci. 2008, 53 (6): 1462-1467. 10.1007/s10620-007-0025-9.CrossRefPubMed Leung FW: Methods of reducing discomfort during colonoscopy. Dig Dis Sci. 2008, 53 (6): 1462-1467. 10.1007/s10620-007-0025-9.CrossRefPubMed
19.
go back to reference Baumann UA: Does retroflexion improve adenoma miss rates on the right side of the colon when using a pediatric variable-stiffness colonoscope during routine colonoscopy. Endoscopy. 2009, 41 (7): 654-10.1055/s-0029-1214876.CrossRefPubMed Baumann UA: Does retroflexion improve adenoma miss rates on the right side of the colon when using a pediatric variable-stiffness colonoscope during routine colonoscopy. Endoscopy. 2009, 41 (7): 654-10.1055/s-0029-1214876.CrossRefPubMed
20.
go back to reference Chen PJ, Shih YL, Chu HC, Chang WK, Hsieh TY, Chao YC: A prospective trial of variable stiffness colonoscopes with different tip diameters in unsedated patients. Am J Gastroenterol. 2008, 103 (6): 1365-1371. 10.1111/j.1572-0241.2008.01812.x.CrossRefPubMed Chen PJ, Shih YL, Chu HC, Chang WK, Hsieh TY, Chao YC: A prospective trial of variable stiffness colonoscopes with different tip diameters in unsedated patients. Am J Gastroenterol. 2008, 103 (6): 1365-1371. 10.1111/j.1572-0241.2008.01812.x.CrossRefPubMed
21.
go back to reference Hsieh YH, Zhou AL, Lin HJ: Comparing different methods of activating the variable stiffness function of a pediatric variable stiffness colonoscope. J Clin Med Assoc. 2008, 71 (1): 23-29. 10.1016/S1726-4901(08)70068-6.CrossRef Hsieh YH, Zhou AL, Lin HJ: Comparing different methods of activating the variable stiffness function of a pediatric variable stiffness colonoscope. J Clin Med Assoc. 2008, 71 (1): 23-29. 10.1016/S1726-4901(08)70068-6.CrossRef
22.
go back to reference Hawari R, Pasricha PJ: Going for the loop:a unique overtube for the difficult colonoscopy. J Clin Gastroenterol. 2007, 41 (2): 138-140. 10.1097/01.mcg.0000225595.01201.d2.CrossRefPubMed Hawari R, Pasricha PJ: Going for the loop:a unique overtube for the difficult colonoscopy. J Clin Gastroenterol. 2007, 41 (2): 138-140. 10.1097/01.mcg.0000225595.01201.d2.CrossRefPubMed
23.
go back to reference Horiuchi A, Nakayama Y: Colonoscopy in the sitting position:lessons learned from self-colonoscopy by using a small-caliber, variable-stiffness colonoscope. Gastrointest Endosc. 2006, 63 (1): 119-120. 10.1016/j.gie.2005.10.014.CrossRefPubMed Horiuchi A, Nakayama Y: Colonoscopy in the sitting position:lessons learned from self-colonoscopy by using a small-caliber, variable-stiffness colonoscope. Gastrointest Endosc. 2006, 63 (1): 119-120. 10.1016/j.gie.2005.10.014.CrossRefPubMed
24.
go back to reference Brown GJ, Saunders BP: Advances in colonic imaging:technical improvements in colonoscopy. Eur J Gastroenterol Hepatol. 2005, 17 (8): 785-792. 10.1097/00042737-200508000-00002.CrossRefPubMed Brown GJ, Saunders BP: Advances in colonic imaging:technical improvements in colonoscopy. Eur J Gastroenterol Hepatol. 2005, 17 (8): 785-792. 10.1097/00042737-200508000-00002.CrossRefPubMed
25.
go back to reference Shumaker DA, Zaman A, Katon RM: Use of variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope. Endoscopy. 2002, 34 (9): 711-714. 10.1055/s-2002-33442.CrossRefPubMed Shumaker DA, Zaman A, Katon RM: Use of variable-stiffness colonoscope allows completion of colonoscopy after failure with the standard adult colonoscope. Endoscopy. 2002, 34 (9): 711-714. 10.1055/s-2002-33442.CrossRefPubMed
26.
go back to reference Heigh RI, et al: Use of electromagnetic colonoscope to assess maneuvers associated with cecal intubation. BMC Gastroenterol. 2009, 9: 24-10.1186/1471-230X-9-24.CrossRefPubMedPubMedCentral Heigh RI, et al: Use of electromagnetic colonoscope to assess maneuvers associated with cecal intubation. BMC Gastroenterol. 2009, 9: 24-10.1186/1471-230X-9-24.CrossRefPubMedPubMedCentral
27.
go back to reference Seitz U, Seewald S, Bohnacker S, Soehendra N: Advances in interventional gastrointestinal endoscopy in colon and rectum. Int J Colorectal Dis. 2003, 18 (1): 12-18. 10.1007/s00384-002-0406-7.CrossRefPubMed Seitz U, Seewald S, Bohnacker S, Soehendra N: Advances in interventional gastrointestinal endoscopy in colon and rectum. Int J Colorectal Dis. 2003, 18 (1): 12-18. 10.1007/s00384-002-0406-7.CrossRefPubMed
28.
go back to reference Brooker JC, Saunders BP, Shah SG, Williams CB: A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial. Gut. 2000, 46: 801-805. 10.1136/gut.46.6.801.CrossRefPubMedPubMedCentral Brooker JC, Saunders BP, Shah SG, Williams CB: A new variable stiffness colonoscope makes colonoscopy easier: a randomised controlled trial. Gut. 2000, 46: 801-805. 10.1136/gut.46.6.801.CrossRefPubMedPubMedCentral
29.
go back to reference Sorbi D, Schleck CD, Zinsmeister AR, Gostout CJ: Clinical application of a new colonoscope with variable insertion tube rigidity: a pilot study. Gastrointest Endosc. 2001, 53: 638-642. 10.1067/mge.2001.114056.CrossRefPubMed Sorbi D, Schleck CD, Zinsmeister AR, Gostout CJ: Clinical application of a new colonoscope with variable insertion tube rigidity: a pilot study. Gastrointest Endosc. 2001, 53: 638-642. 10.1067/mge.2001.114056.CrossRefPubMed
30.
go back to reference Shumaker DA, Zaman A, Katon RM: A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope. Gastrointest Endosc. 2002, 55: 112-179.CrossRef Shumaker DA, Zaman A, Katon RM: A randomized controlled trial in a training institution comparing a pediatric variable stiffness colonoscope, a pediatric colonoscope, and an adult colonoscope. Gastrointest Endosc. 2002, 55: 112-179.CrossRef
31.
go back to reference Yoshikawa I, Honda H, Nagata K, Kanda K, Yamasaki T, Kume K, Tabaru A, Otsuki M: Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients. Am J Gastroenterol. 2002, 97: 3052-3055. 10.1111/j.1572-0241.2002.07100.x.CrossRefPubMed Yoshikawa I, Honda H, Nagata K, Kanda K, Yamasaki T, Kume K, Tabaru A, Otsuki M: Variable stiffness colonoscopes are associated with less pain during colonoscopy in unsedated patients. Am J Gastroenterol. 2002, 97: 3052-3055. 10.1111/j.1572-0241.2002.07100.x.CrossRefPubMed
32.
go back to reference Horiuchi A, Nakayama Y, Kajiyama M, Fujii H, Tanaka N: Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. American J Gastroenterology. 2004, 99: 1936-1940. 10.1111/j.1572-0241.2004.40201.x.CrossRef Horiuchi A, Nakayama Y, Kajiyama M, Fujii H, Tanaka N: Usefulness of a small-caliber, variable-stiffness colonoscope as a backup in patients with difficult or incomplete colonoscopy. American J Gastroenterology. 2004, 99: 1936-1940. 10.1111/j.1572-0241.2004.40201.x.CrossRef
33.
go back to reference Al−Shurieki SH, Marshall JB: Is the variable-stiffness paediatric colonoscopemore effective than a standard adult colonoscope for outpatient adult colonoscopy? A randomised controlled trial. Dig Liver Dis. 2005, 37: 698-704. 10.1016/j.dld.2005.03.011.CrossRefPubMed Al−Shurieki SH, Marshall JB: Is the variable-stiffness paediatric colonoscopemore effective than a standard adult colonoscope for outpatient adult colonoscopy? A randomised controlled trial. Dig Liver Dis. 2005, 37: 698-704. 10.1016/j.dld.2005.03.011.CrossRefPubMed
34.
go back to reference Lee DW, Li SAC, Ko CW, Chu DW, Chan KC, Poon CM, Sin KS, Leung KF, Sze TS, Chan AC, Chung SC: Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes. Gastrointest Endosc. 2007, 65: 424-429. 10.1016/j.gie.2006.08.027.CrossRefPubMed Lee DW, Li SAC, Ko CW, Chu DW, Chan KC, Poon CM, Sin KS, Leung KF, Sze TS, Chan AC, Chung SC: Use of a variable-stiffness colonoscope decreases the dose of patient-controlled sedation during colonoscopy: a randomized comparison of 3 colonoscopes. Gastrointest Endosc. 2007, 65: 424-429. 10.1016/j.gie.2006.08.027.CrossRefPubMed
35.
go back to reference Sola-Vera J, Uceda F, Brotons A, Sáez J, Girona E, Pérez E, Picó MD, Grau C, Sillero C: Does the use of a variable stiffness colonoscope offer advantages during colonscopy under deep sedation?Results of a randomized trial. Eur J Gastroenterol Hepatol. 2011, 23 (7): 593-597. 10.1097/MEG.0b013e32834793d3.CrossRefPubMed Sola-Vera J, Uceda F, Brotons A, Sáez J, Girona E, Pérez E, Picó MD, Grau C, Sillero C: Does the use of a variable stiffness colonoscope offer advantages during colonscopy under deep sedation?Results of a randomized trial. Eur J Gastroenterol Hepatol. 2011, 23 (7): 593-597. 10.1097/MEG.0b013e32834793d3.CrossRefPubMed
Metadata
Title
Does the variable-stiffness colonoscope makes colonoscopy easier? A meta-analysis of the efficacy of the variable stiffness colonoscope compared with the standard adult colonoscope
Authors
Qin Xie
Bin Chen
Liu Liu
Huatian Gan
Publication date
01-12-2012
Publisher
BioMed Central
Published in
BMC Gastroenterology / Issue 1/2012
Electronic ISSN: 1471-230X
DOI
https://doi.org/10.1186/1471-230X-12-151

Other articles of this Issue 1/2012

BMC Gastroenterology 1/2012 Go to the issue