Abstract

Background

For immune monitoring studies during HIV vaccine clinical trials, whole blood specimens from HIV seropositive (HIV+) patients may be collected at multiple sites and sent to a central location for peripheral blood mononuclear cell (PBMC) isolation, cryopreservation and functional evaluation. In this study we show a comparison of two PBMC preparation options, Ficoll density gradient separation (Ficoll) and Cell Preparation Tubes (CPT) using shipped whole blood specimens from 19 HIV+ patients (CD4 > 350, viral load < 50). The pre- and post- cryopreservation performance of samples collected by these two methods were compared by assessment of antigen-specific IFNγ expression in CD8+ and CD8- T cells, cellular viability, and cellular recovery.

Results

The results indicate that cryopreserved PBMC samples tested for CMV- and HIV- specific interferon-gamma (IFNγ) expression performed equivalent to the respective fresh PBMC processed under both collection conditions. Compared to fresh PBMC, the viability was significantly lower for cryopreserved PBMC derived using Ficoll, although it was never less than 90%. There were no significant differences in the IFNγ response, viability, or recovery between cryopreserved PBMC derived by Ficoll and by CPT.

Conclusion

These data suggest that CPT is an efficient system for the collection and cryopreservation of functionally active HIV+ PBMC, as well as a viable alternative to Ficoll gradient separation.
Appendix
Available only for authorised users
Literature
1.
go back to reference Betensky RA, Connick E, Devers J, Landay AL, Nokta M, Plaeger S, Rosenblatt H, Schmitz JL, Valentine F, Wara D, Weinberg A, Lederman HM: Shipment impairs lymphocyte proliferative responses to microbial antigens. Clin Diagn Lab Immunol. 2000, 7: 759-763. 10.1128/CDLI.7.5.759-763.2000.PubMedCentralPubMed Betensky RA, Connick E, Devers J, Landay AL, Nokta M, Plaeger S, Rosenblatt H, Schmitz JL, Valentine F, Wara D, Weinberg A, Lederman HM: Shipment impairs lymphocyte proliferative responses to microbial antigens. Clin Diagn Lab Immunol. 2000, 7: 759-763. 10.1128/CDLI.7.5.759-763.2000.PubMedCentralPubMed
2.
go back to reference Reimann KA, Chernoff M, Wilkening CL, Nickerson CE, Landay AL: Preservation of lymphocyte immunophenotype and proliferative responses in cryopreserved peripheral blood mononuclear cells from human immunodeficiency virus type 1-infected donors: implications for multicenter clinical trials. The ACTG Immunology Advanced Technology Laboratories. Clin Diagn Lab Immunol. 2000, 7: 352-359. 10.1128/CDLI.7.3.352-359.2000.PubMedCentralPubMed Reimann KA, Chernoff M, Wilkening CL, Nickerson CE, Landay AL: Preservation of lymphocyte immunophenotype and proliferative responses in cryopreserved peripheral blood mononuclear cells from human immunodeficiency virus type 1-infected donors: implications for multicenter clinical trials. The ACTG Immunology Advanced Technology Laboratories. Clin Diagn Lab Immunol. 2000, 7: 352-359. 10.1128/CDLI.7.3.352-359.2000.PubMedCentralPubMed
3.
go back to reference Costantini A, Mancini S, Giuliodoro S, Butini L, Regnery CM, Silvestri G, Montroni M: Effects of cryopreservation on lymphocyte immunophenotype and function. J Immunol Methods. 2003, 278: 145-155. 10.1016/S0022-1759(03)00202-3.CrossRefPubMed Costantini A, Mancini S, Giuliodoro S, Butini L, Regnery CM, Silvestri G, Montroni M: Effects of cryopreservation on lymphocyte immunophenotype and function. J Immunol Methods. 2003, 278: 145-155. 10.1016/S0022-1759(03)00202-3.CrossRefPubMed
4.
go back to reference Weinberg A, Betensky RA, Zhang L, Ray G: Effect of shipment, storage, anticoagulant, and cell separation on lymphocyte proliferation assays for human immunodeficiency virus-infected patients. Clin Diagn Lab Immunol. 1998, 5: 804-807.PubMedCentralPubMed Weinberg A, Betensky RA, Zhang L, Ray G: Effect of shipment, storage, anticoagulant, and cell separation on lymphocyte proliferation assays for human immunodeficiency virus-infected patients. Clin Diagn Lab Immunol. 1998, 5: 804-807.PubMedCentralPubMed
5.
go back to reference Pantaleo G, Koup RA: Correlates of immune protection in HIV-1 infection: what we know, what we don't know, what we should know. Nat Med. 2004, 10: 806-810. 10.1038/nm0804-806.CrossRefPubMed Pantaleo G, Koup RA: Correlates of immune protection in HIV-1 infection: what we know, what we don't know, what we should know. Nat Med. 2004, 10: 806-810. 10.1038/nm0804-806.CrossRefPubMed
6.
go back to reference Kleeberger CA, Lyles RH, Margolick JB, Rinaldo CR, Phair JP, Giorgi JV: Viability and recovery of peripheral blood mononuclear cells cryopreserved for up to 12 years in a multicenter study. Clin Diagn Lab Immunol. 1999, 6: 14-19.PubMedCentralPubMed Kleeberger CA, Lyles RH, Margolick JB, Rinaldo CR, Phair JP, Giorgi JV: Viability and recovery of peripheral blood mononuclear cells cryopreserved for up to 12 years in a multicenter study. Clin Diagn Lab Immunol. 1999, 6: 14-19.PubMedCentralPubMed
7.
go back to reference Weinberg A, Wohl DA, Brown DG, Pott GB, Zhang L, Ray MG, van der Horst C: Effect of cryopreservation on measurement of cytomegalovirus-specific cellular immune responses in HIV-infected patients. J Acquir Immune Defic Syndr. 2000, 25: 109-114. 10.1097/00042560-200010010-00004.CrossRefPubMed Weinberg A, Wohl DA, Brown DG, Pott GB, Zhang L, Ray MG, van der Horst C: Effect of cryopreservation on measurement of cytomegalovirus-specific cellular immune responses in HIV-infected patients. J Acquir Immune Defic Syndr. 2000, 25: 109-114. 10.1097/00042560-200010010-00004.CrossRefPubMed
8.
go back to reference Kreher CR, Dittrich MT, Guerkov R, Boehm BO, Tary-Lehmann M: CD4+ and CD8+ cells in cryopreserved human PBMC maintain full functionality in cytokine ELISPOT assays. J Immunol Methods. 2003, 278: 79-93. 10.1016/S0022-1759(03)00226-6.CrossRefPubMed Kreher CR, Dittrich MT, Guerkov R, Boehm BO, Tary-Lehmann M: CD4+ and CD8+ cells in cryopreserved human PBMC maintain full functionality in cytokine ELISPOT assays. J Immunol Methods. 2003, 278: 79-93. 10.1016/S0022-1759(03)00226-6.CrossRefPubMed
9.
go back to reference Maecker HT, Moon J, Bhatia S, Ghanekar SA, Maino VC, Payne JK, Kuus-Reichel K, Chang JC, Summers A, Clay TM, Morse MA, Lyerly HK, DeLaRosa C, Ankerst DP, Disis ML: Impact of cryopreservation on tetramer, cytokine flow cytometry, and ELISPOT. BMC Immunol. 2005, 6: 17-10.1186/1471-2172-6-17.PubMedCentralCrossRefPubMed Maecker HT, Moon J, Bhatia S, Ghanekar SA, Maino VC, Payne JK, Kuus-Reichel K, Chang JC, Summers A, Clay TM, Morse MA, Lyerly HK, DeLaRosa C, Ankerst DP, Disis ML: Impact of cryopreservation on tetramer, cytokine flow cytometry, and ELISPOT. BMC Immunol. 2005, 6: 17-10.1186/1471-2172-6-17.PubMedCentralCrossRefPubMed
10.
go back to reference Disis ML, dela Rosa C, Goodell V, Kuan L, Chang JC, Kuus-Reichel K, Clay T, Lyerly HK, Waters CA, Ghanekar SA, Maino VC, Maecker HT: Maximizing the Retention of Antigen-Specific Lymphocyte Function after Cryopreservation. J Immunol Methods. 2006, 308: 13-18. 10.1016/j.jim.2005.09.011.CrossRefPubMed Disis ML, dela Rosa C, Goodell V, Kuan L, Chang JC, Kuus-Reichel K, Clay T, Lyerly HK, Waters CA, Ghanekar SA, Maino VC, Maecker HT: Maximizing the Retention of Antigen-Specific Lymphocyte Function after Cryopreservation. J Immunol Methods. 2006, 308: 13-18. 10.1016/j.jim.2005.09.011.CrossRefPubMed
11.
go back to reference Weinberg A, Zhang L, Brown D, Erice A, Polsky B, Hirsch MS, Owens S, Lamb K: Viability and functional activity of cryopreserved mononuclear cells. Clin Diagn Lab Immunol. 2000, 7: 714-716. 10.1128/CDLI.7.4.714-716.2000.PubMedCentralPubMed Weinberg A, Zhang L, Brown D, Erice A, Polsky B, Hirsch MS, Owens S, Lamb K: Viability and functional activity of cryopreserved mononuclear cells. Clin Diagn Lab Immunol. 2000, 7: 714-716. 10.1128/CDLI.7.4.714-716.2000.PubMedCentralPubMed
12.
go back to reference Waldrop SL, Pitcher CJ, Peterson DM, Maino VC, Picker LJ: Determination of antigen-specific memory/effector CD4+ T cell frequencies by flow cytometry: evidence for a novel, antigen-specific homeostatic mechanism in HIV-associated immunodeficiency. J Clin Invest. 1997, 99: 1739-1750.PubMedCentralCrossRefPubMed Waldrop SL, Pitcher CJ, Peterson DM, Maino VC, Picker LJ: Determination of antigen-specific memory/effector CD4+ T cell frequencies by flow cytometry: evidence for a novel, antigen-specific homeostatic mechanism in HIV-associated immunodeficiency. J Clin Invest. 1997, 99: 1739-1750.PubMedCentralCrossRefPubMed
13.
go back to reference Suni MA, Picker LJ, Maino VC: Detection of antigen-specific T cell cytokine expression in whole blood by flow cytometry. J Immunol Methods. 1998, 212: 89-98. 10.1016/S0022-1759(98)00004-0.CrossRefPubMed Suni MA, Picker LJ, Maino VC: Detection of antigen-specific T cell cytokine expression in whole blood by flow cytometry. J Immunol Methods. 1998, 212: 89-98. 10.1016/S0022-1759(98)00004-0.CrossRefPubMed
14.
go back to reference Ghanekar SA, Maecker HT: Cytokine flow cytometry: multiparametric approach to immune function analysis. Cytotherapy. 2003, 5: 1-6. 10.1080/14653240310000029.CrossRefPubMed Ghanekar SA, Maecker HT: Cytokine flow cytometry: multiparametric approach to immune function analysis. Cytotherapy. 2003, 5: 1-6. 10.1080/14653240310000029.CrossRefPubMed
15.
go back to reference Suni MA, Dunn HS, Orr PL, deLaat R, Sinclair E, Ghanekar SA, Bredt BM, Dunne JF, Maino VC, Maecker HT: Performance of plate-based cytokine flow cytometry with automated data analysis. BMC Immunology. 2003, 4: 9-10.1186/1471-2172-4-9.PubMedCentralCrossRefPubMed Suni MA, Dunn HS, Orr PL, deLaat R, Sinclair E, Ghanekar SA, Bredt BM, Dunne JF, Maino VC, Maecker HT: Performance of plate-based cytokine flow cytometry with automated data analysis. BMC Immunology. 2003, 4: 9-10.1186/1471-2172-4-9.PubMedCentralCrossRefPubMed
16.
go back to reference Dunn HS, Haney DJ, Ghanekar SA, Stepick-Biek P, Lewis DB, Maecker HT: Dynamics of CD4 and CD8 T cell responses to cytomegalovirus in healthy human donors. J Infect Dis. 2002, 186: 15-22. 10.1086/341079.CrossRefPubMed Dunn HS, Haney DJ, Ghanekar SA, Stepick-Biek P, Lewis DB, Maecker HT: Dynamics of CD4 and CD8 T cell responses to cytomegalovirus in healthy human donors. J Infect Dis. 2002, 186: 15-22. 10.1086/341079.CrossRefPubMed
17.
go back to reference Maecker HT, Rinfret A, D'Souza P, Darden J, Roig E, Landry C, Hayes P, Birungi J, Anzala O, Garcia M, Harari A, Frank I, Baydo R, Baker M, Holbrook J, Ottinger J, Lamoreaux L, Epling CL, Sinclair E, Suni MA, Punt K, Calarota S, El-Bahi S, Alter G, Maila H, Kuta E, Cox J, Gray C, Altfeld M, Nougarede N, Boyer J, Tussey L, Tobery T, Bredt B, Roederer M, Koup R, Maino VC, Weinhold K, Pantaleo G, Gilmour J, Horton H, Sekaly RP: Standardization of cytokine flow cytometry assays. BMC Immunol. 2005, 6: 13-10.1186/1471-2172-6-13.PubMedCentralCrossRefPubMed Maecker HT, Rinfret A, D'Souza P, Darden J, Roig E, Landry C, Hayes P, Birungi J, Anzala O, Garcia M, Harari A, Frank I, Baydo R, Baker M, Holbrook J, Ottinger J, Lamoreaux L, Epling CL, Sinclair E, Suni MA, Punt K, Calarota S, El-Bahi S, Alter G, Maila H, Kuta E, Cox J, Gray C, Altfeld M, Nougarede N, Boyer J, Tussey L, Tobery T, Bredt B, Roederer M, Koup R, Maino VC, Weinhold K, Pantaleo G, Gilmour J, Horton H, Sekaly RP: Standardization of cytokine flow cytometry assays. BMC Immunol. 2005, 6: 13-10.1186/1471-2172-6-13.PubMedCentralCrossRefPubMed
18.
go back to reference Maecker HT, Dunn HS, Suni MA, Khatamzas E, Pitcher CJ, Bunde T, Persaud N, Trigona W, Fu TM, Sinclair E, Bredt BM, McCune JM, Maino VC, Kern F, Picker LJ: Use of overlapping peptide mixtures as antigens for cytokine flow cytometry. J Immunol Methods. 2001, 255: 27-40. 10.1016/S0022-1759(01)00416-1.CrossRefPubMed Maecker HT, Dunn HS, Suni MA, Khatamzas E, Pitcher CJ, Bunde T, Persaud N, Trigona W, Fu TM, Sinclair E, Bredt BM, McCune JM, Maino VC, Kern F, Picker LJ: Use of overlapping peptide mixtures as antigens for cytokine flow cytometry. J Immunol Methods. 2001, 255: 27-40. 10.1016/S0022-1759(01)00416-1.CrossRefPubMed
Metadata
Title
VACUTAINER® CPT™ and Ficoll density gradient separation perform equivalently in maintaining the quality and function of PBMC from HIV seropositive blood samples
Authors
Joyce J Ruitenberg
Candice B Mulder
Vernon C Maino
Alan L Landay
Smita A Ghanekar
Publication date
01-12-2006
Publisher
BioMed Central
Published in
BMC Immunology / Issue 1/2006
Electronic ISSN: 1471-2172
DOI
https://doi.org/10.1186/1471-2172-7-11

Other articles of this Issue 1/2006

BMC Immunology 1/2006 Go to the issue