Abstract

Background

The utility of endotracheal bioimpedance cardiography (ECOM) has been scarcely reported. We tested the hypothesis that it could be an alternative to pulse contour analysis for cardiac index measurement and prediction in fluid responsiveness.

Methods

Twenty-five consecutive adult patients admitted to the intensive care unit following conventional cardiac surgery were prospectively included and investigated at baseline, during passive leg raising, and after fluid challenge. Comparative cardiac index data points were collected from pulse contour analysis (CIPC) and ECOM (CIECOM). Correlations were determined by linear regression. Bland-Altman analysis was used to compare the bias, precision, and limits of agreement. Percentage error was calculated. Changes in CIPC (ΔCIPC) and CIECOM (ΔCIECOM) during passive leg raising were collected to assess their discrimination in predicting fluid responsiveness.

Results

A significant relationship was found between CIPC and CIECOM (r = 0.45; P < 0.001). Bias, precision, and limits of agreement were 0.44 L.min-1.m-2 (95% confidence interval, 0.33-0.56), 0.59 L.min-1.m-2, and −0.73 to 1.62 L.min-1.m-2, respectively. Percentage error was 45%. A significant relationship was found between percent changes in CIPC and CIECOM after fluid challenge (r = 0.42; P = 0.035). Areas under the ROC curves for ΔCIPC and ΔCIECOM to predict fluid responsiveness were 0.72 (95% confidence interval, 0.5–0.88) and 0.81 (95% confidence interval, 0.61-0.94), respectively.

Conclusions

ECOM is not interchangeable with pulse contour analysis but seems consistent to monitor cardiac index continuously and could help to predict fluid responsiveness by using passive leg raising.
Appendix
Available only for authorised users
Literature
1.
go back to reference Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37: 2642–2647. 10.1097/CCM.0b013e3181a590daPubMedCrossRef Marik PE, Cavallazzi R, Vasu T, Hirani A: Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med 2009, 37: 2642–2647. 10.1097/CCM.0b013e3181a590daPubMedCrossRef
2.
go back to reference Cannesson M: Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth 2010, 24: 487–497. 10.1053/j.jvca.2009.10.008PubMedCrossRef Cannesson M: Arterial pressure variation and goal-directed fluid therapy. J Cardiothorac Vasc Anesth 2010, 24: 487–497. 10.1053/j.jvca.2009.10.008PubMedCrossRef
3.
go back to reference Maguire S, Rinehart J, Vakharia S, Cannesson M: Respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg 2011, 112: 94–96. 10.1213/ANE.0b013e318200366bPubMedCrossRef Maguire S, Rinehart J, Vakharia S, Cannesson M: Respiratory variation in pulse pressure and plethysmographic waveforms: intraoperative applicability in a North American academic center. Anesth Analg 2011, 112: 94–96. 10.1213/ANE.0b013e318200366bPubMedCrossRef
4.
go back to reference Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B: Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "Gray Zone" approach. Anesthesiology 2011, 115: 231–241. 10.1097/ALN.0b013e318225b80aPubMedCrossRef Cannesson M, Le Manach Y, Hofer CK, Goarin JP, Lehot JJ, Vallet B, Tavernier B: Assessing the diagnostic accuracy of pulse pressure variations for the prediction of fluid responsiveness: a "Gray Zone" approach. Anesthesiology 2011, 115: 231–241. 10.1097/ALN.0b013e318225b80aPubMedCrossRef
5.
go back to reference Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G: Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest 2002, 121: 1245–1252. 10.1378/chest.121.4.1245PubMedCrossRef Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G: Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest 2002, 121: 1245–1252. 10.1378/chest.121.4.1245PubMedCrossRef
6.
go back to reference Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34: 1402–1407. 10.1097/01.CCM.0000215453.11735.06PubMedCrossRef Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34: 1402–1407. 10.1097/01.CCM.0000215453.11735.06PubMedCrossRef
7.
go back to reference Lafanechere A, Pene F, Goulenok C, Delahaye A, Mallet V, Choukroun G, Chiche JD, Mira JP, Cariou A: Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Crit Care 2006, 10: R132. 10.1186/cc5044PubMedCentralPubMedCrossRef Lafanechere A, Pene F, Goulenok C, Delahaye A, Mallet V, Choukroun G, Chiche JD, Mira JP, Cariou A: Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients. Crit Care 2006, 10: R132. 10.1186/cc5044PubMedCentralPubMedCrossRef
8.
go back to reference Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Mariglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36: 1475–1483. 10.1007/s00134-010-1929-yPubMedCrossRef Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Mariglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36: 1475–1483. 10.1007/s00134-010-1929-yPubMedCrossRef
9.
go back to reference Geerts B, de Wilde R, Aarts L, Jansen J: Pulse contour analysis to assess hemodynamic response to passive leg raising. J Cardiothorac Vasc Anesth 2011, 25: 48–52. 10.1053/j.jvca.2010.09.013PubMedCrossRef Geerts B, de Wilde R, Aarts L, Jansen J: Pulse contour analysis to assess hemodynamic response to passive leg raising. J Cardiothorac Vasc Anesth 2011, 25: 48–52. 10.1053/j.jvca.2010.09.013PubMedCrossRef
10.
go back to reference Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P: Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 2010, 36: 1875–1881. 10.1007/s00134-010-1990-6PubMedCrossRef Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P: Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med 2010, 36: 1875–1881. 10.1007/s00134-010-1990-6PubMedCrossRef
11.
go back to reference Wallace AW, Salahieh A, Lawrence A, Spector K, Owens C, Alonso D: Endotracheal cardiac output monitor. Anesthesiology 2000, 92: 178–189. 10.1097/00000542-200001000-00030PubMedCrossRef Wallace AW, Salahieh A, Lawrence A, Spector K, Owens C, Alonso D: Endotracheal cardiac output monitor. Anesthesiology 2000, 92: 178–189. 10.1097/00000542-200001000-00030PubMedCrossRef
12.
go back to reference Ball TR, Culp BC, Patel V, Gloyna DF, Ciceri DP, Culp WC: Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc Anesth 2010, 24: 762–766. 10.1053/j.jvca.2010.04.008PubMedCrossRef Ball TR, Culp BC, Patel V, Gloyna DF, Ciceri DP, Culp WC: Comparison of the endotracheal cardiac output monitor to thermodilution in cardiac surgery patients. J Cardiothorac Vasc Anesth 2010, 24: 762–766. 10.1053/j.jvca.2010.04.008PubMedCrossRef
13.
go back to reference Maus TM, Reber B, Banks DA, Berry A, Guerrero E, Manecke GR: Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor. J Cardiothorac Vasc Anesth 2011, 25: 770–775. 10.1053/j.jvca.2010.12.017PubMedCrossRef Maus TM, Reber B, Banks DA, Berry A, Guerrero E, Manecke GR: Cardiac output determination from endotracheally measured impedance cardiography: clinical evaluation of endotracheal cardiac output monitor. J Cardiothorac Vasc Anesth 2011, 25: 770–775. 10.1053/j.jvca.2010.12.017PubMedCrossRef
14.
go back to reference Fellahi JL, Fischer MO, Rebet O, Massetti M, Gerard JL, Hanouz JL: A comparison of endotracheal bioimpedance cardiography and transpulmonary thermodilution in cardiac surgery patients. J Cardiothorac Vasc Anesth 2012, 26: 217–222. 10.1053/j.jvca.2011.06.023PubMedCrossRef Fellahi JL, Fischer MO, Rebet O, Massetti M, Gerard JL, Hanouz JL: A comparison of endotracheal bioimpedance cardiography and transpulmonary thermodilution in cardiac surgery patients. J Cardiothorac Vasc Anesth 2012, 26: 217–222. 10.1053/j.jvca.2011.06.023PubMedCrossRef
15.
go back to reference Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Moher D, Rennie D, de Vet HC, Lijmer JG: The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration. Ann Intern Med 2003, 138: W1-W12.PubMedCrossRef Bossuyt PM, Reitsma JB, Bruns DE, Gatsonis CA, Glasziou PP, Irwig LM, Moher D, Rennie D, de Vet HC, Lijmer JG: The STARD statement for reporting studies of diagnostic accuracy: Explanation and elaboration. Ann Intern Med 2003, 138: W1-W12.PubMedCrossRef
16.
go back to reference Monnet X, Persichini R, Ktari M, Jozwiak M, Richard C, Teboul JL: Precision of the transpulmonary thermodilution measurements. Crit Care 2011, 15: R204. 10.1186/cc10421PubMedCentralPubMedCrossRef Monnet X, Persichini R, Ktari M, Jozwiak M, Richard C, Teboul JL: Precision of the transpulmonary thermodilution measurements. Crit Care 2011, 15: R204. 10.1186/cc10421PubMedCentralPubMedCrossRef
17.
go back to reference Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659–663. 10.1007/s00134-008-0994-yPubMedCrossRef Monnet X, Teboul JL: Passive leg raising. Intensive Care Med 2008, 34: 659–663. 10.1007/s00134-008-0994-yPubMedCrossRef
18.
go back to reference Fellahi JL, Caille V, Charron C, Deschamps-Berger PH, Vieillard-Baron A: Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth Analg 2009, 108: 1553–1559. 10.1213/ane.0b013e31819cd97ePubMedCrossRef Fellahi JL, Caille V, Charron C, Deschamps-Berger PH, Vieillard-Baron A: Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography. Anesth Analg 2009, 108: 1553–1559. 10.1213/ane.0b013e31819cd97ePubMedCrossRef
19.
go back to reference Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307–310.PubMedCrossRef Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986, 1: 307–310.PubMedCrossRef
20.
go back to reference Bland JM, Altman DG: Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007, 17: 571–582. 10.1080/10543400701329422PubMedCrossRef Bland JM, Altman DG: Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 2007, 17: 571–582. 10.1080/10543400701329422PubMedCrossRef
21.
go back to reference Critchley LA, Critchley JA: A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999, 15: 85–91. 10.1023/A:1009982611386PubMedCrossRef Critchley LA, Critchley JA: A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J Clin Monit Comput 1999, 15: 85–91. 10.1023/A:1009982611386PubMedCrossRef
22.
go back to reference DeLong ER, DeLong DM, Clarke-Pearson DL: Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988, 44: 837–845. 10.2307/2531595PubMedCrossRef DeLong ER, DeLong DM, Clarke-Pearson DL: Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988, 44: 837–845. 10.2307/2531595PubMedCrossRef
23.
go back to reference Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM: A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med 1999, 27: 1203–1213. 10.1097/00003246-199906000-00053PubMedCrossRef Raaijmakers E, Faes TJ, Scholten RJ, Goovaerts HG, Heethaar RM: A meta-analysis of three decades of validating thoracic impedance cardiography. Crit Care Med 1999, 27: 1203–1213. 10.1097/00003246-199906000-00053PubMedCrossRef
24.
go back to reference Spiess BD, Patel MA, Soltow LO, Wright IH: Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: evaluation of a second-generation bioimpedance device. J Cardiothorac Vasc Anesth 2001, 15: 567–573. 10.1053/jcan.2001.26533PubMedCrossRef Spiess BD, Patel MA, Soltow LO, Wright IH: Comparison of bioimpedance versus thermodilution cardiac output during cardiac surgery: evaluation of a second-generation bioimpedance device. J Cardiothorac Vasc Anesth 2001, 15: 567–573. 10.1053/jcan.2001.26533PubMedCrossRef
25.
go back to reference de Waal EEC, Konings MK, Kalkman CJ, Buhre WF: Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution. Intensive Care Med 2008, 34: 735–739. 10.1007/s00134-007-0938-yPubMedCentralPubMedCrossRef de Waal EEC, Konings MK, Kalkman CJ, Buhre WF: Assessment of stroke volume index with three different bioimpedance algorithms: lack of agreement compared to thermodilution. Intensive Care Med 2008, 34: 735–739. 10.1007/s00134-007-0938-yPubMedCentralPubMedCrossRef
26.
go back to reference Peyton PJ, Chong SW: Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 2010, 113: 1220–1235. 10.1097/ALN.0b013e3181ee3130PubMedCrossRef Peyton PJ, Chong SW: Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology 2010, 113: 1220–1235. 10.1097/ALN.0b013e3181ee3130PubMedCrossRef
27.
go back to reference Feldman JM: Is it a bird? Is it a plane? The role of patient monitors in medical decision making. Anesth Analg 2009, 108: 707–710. 10.1213/ane.0b013e318196c7b6PubMedCrossRef Feldman JM: Is it a bird? Is it a plane? The role of patient monitors in medical decision making. Anesth Analg 2009, 108: 707–710. 10.1213/ane.0b013e318196c7b6PubMedCrossRef
28.
go back to reference Linton NW, Linton RA: Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method? Br J Anaesth 2002, 89: 336–337. 10.1093/bja/aef530PubMedCrossRef Linton NW, Linton RA: Is comparison of changes in cardiac output, assessed by different methods, better than only comparing cardiac output to the reference method? Br J Anaesth 2002, 89: 336–337. 10.1093/bja/aef530PubMedCrossRef
29.
go back to reference Bein B, Renner J, Scholz J, Tonner PH: Comparing different methods of cardiac output determination: a call for consensus. Eur J Anaesthesiol 2006, 23: 710. 10.1017/S0265021506211128PubMedCrossRef Bein B, Renner J, Scholz J, Tonner PH: Comparing different methods of cardiac output determination: a call for consensus. Eur J Anaesthesiol 2006, 23: 710. 10.1017/S0265021506211128PubMedCrossRef
30.
go back to reference Critchley LA, Lee A, Ho AMH: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010, 111: 1180–1192. 10.1213/ANE.0b013e3181f08a5bPubMedCrossRef Critchley LA, Lee A, Ho AMH: A critical review of the ability of continuous cardiac output monitors to measure trends in cardiac output. Anesth Analg 2010, 111: 1180–1192. 10.1213/ANE.0b013e3181f08a5bPubMedCrossRef
31.
go back to reference Rutlen DL, Wackers FJ, Zaret BL: Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man. Circulation 1981, 64: 146–152. 10.1161/01.CIR.64.1.146PubMedCrossRef Rutlen DL, Wackers FJ, Zaret BL: Radionuclide assessment of peripheral intravascular capacity: a technique to measure intravascular volume changes in the capacitance circulation in man. Circulation 1981, 64: 146–152. 10.1161/01.CIR.64.1.146PubMedCrossRef
Metadata
Title
Can endotracheal bioimpedance cardiography assess hemodynamic response to passive leg raising following cardiac surgery?
Authors
Jean-Luc Fellahi
Marc-Olivier Fischer
Audrey Dalbera
Massimo Massetti
Jean-Louis Gérard
Jean-Luc Hanouz
Publication date
01-12-2012
Publisher
Springer Paris
Published in
Annals of Intensive Care / Issue 1/2012
Electronic ISSN: 2110-5820
DOI
https://doi.org/10.1186/2110-5820-2-26

Other articles of this Issue 1/2012

Annals of Intensive Care 1/2012 Go to the issue