01-07-2018 | Original Article

Frequency of a large drift caused by pressure wire using optical fibers

Authors: Yoshiaki Kawase, Toru Tanigaki, Akihiro Hirakawa, Hiroyuki Omori, Tetsuo Hirata, Syuuichi Okamoto, Hideaki Ota, Jun Kikuchi, Munenori Okubo, Hiroki Kamiya, Masanori Kawasaki, Takahiko Suzuki, Hitoshi Matsuo

Published in: Cardiovascular Intervention and Therapeutics | Issue 3/2018

Login to get access

Abstract

The frequency of a large pressure signal drift (PDs) caused by pressure wire using optical fibers and its effect on fractional flow reserve (FFR)-based decision-making is not clear. We used pressure wires using optical fibers as “workhorse wires” for 95 consecutive lesions. The wire was normalized at the tip of the guiding catheter just before performing the percutaneous coronary intervention (PCI) and was used without re-normalization until the end of the PCI. The drift value at the end of the procedures was evaluated. Four per cent (n = 4) of patients showed a large drift (PD >3 mmHg). Classification discordance between read-out and PD-corrected FFR values was detected in 8 (8%) measurements in total. The decision changed from FFR ≤0.80 to >0.80 in 7 (7%) measurements and vice versa in 1 (1%) measurement. PD showed no effect on decision-making when the FFR read-out value was <0.78 or >0.82. The frequency of large drifts caused by pressure wires using optical fibers was 4%. However, no case showed decision changes when the FFR gray zone was considered.
Literature
1.
go back to reference Nam CW, Hur SH, Cho YK, Park HS, Yoon HJ, Kim H, et al. Relation of fractional flow reserve after drug-eluting stent implantation to one-year outcomes. Am J Cardiol. 2011;107:1763–7.CrossRefPubMed Nam CW, Hur SH, Cho YK, Park HS, Yoon HJ, Kim H, et al. Relation of fractional flow reserve after drug-eluting stent implantation to one-year outcomes. Am J Cardiol. 2011;107:1763–7.CrossRefPubMed
2.
go back to reference Shin ES, Ann SH, Balbir Singh G, Lim KH, Kleber FX, Koo BK. Fractional flow reserve-guided paclitaxel-coated balloon treatment for de novo coronary lesions. Catheter Cardiovasc Interv. 2016;88:193–200.CrossRefPubMed Shin ES, Ann SH, Balbir Singh G, Lim KH, Kleber FX, Koo BK. Fractional flow reserve-guided paclitaxel-coated balloon treatment for de novo coronary lesions. Catheter Cardiovasc Interv. 2016;88:193–200.CrossRefPubMed
3.
go back to reference Agarwal SK, Kasula S, Hacioglu Y, Ahmed Z, Uretsky BF, Hakeem A. Utilizing post-intervention fractional flow reserve to optimize acute results and the relationship to long-term outcomes. JACC Cardiovasc Interv. 2016;9:1022–31.CrossRefPubMed Agarwal SK, Kasula S, Hacioglu Y, Ahmed Z, Uretsky BF, Hakeem A. Utilizing post-intervention fractional flow reserve to optimize acute results and the relationship to long-term outcomes. JACC Cardiovasc Interv. 2016;9:1022–31.CrossRefPubMed
4.
go back to reference Menon M, Jaffe W, Watson T, Webster M. Assessment of coronary fractional flow reserve using a monorail pressure catheter: the first-in-human ACCESS-NZ trial. EuroIntervention. 2015;11:257–63.CrossRefPubMed Menon M, Jaffe W, Watson T, Webster M. Assessment of coronary fractional flow reserve using a monorail pressure catheter: the first-in-human ACCESS-NZ trial. EuroIntervention. 2015;11:257–63.CrossRefPubMed
5.
go back to reference Kern MJ. Comparing FFR tools: new wires and a pressure microcatheter. Cathet Lab Digest. 2016;24:4–9. Kern MJ. Comparing FFR tools: new wires and a pressure microcatheter. Cathet Lab Digest. 2016;24:4–9.
6.
go back to reference Wakasa N, Kuramochi T, Mihashi N, Terada N, Kanaji Y, Murai T, et al. Impact of pressure signal drift on fractional flow reserve-based decision-making for patients with intermediate coronary artery stenosis. Circ J. 2016;80:1812–9.CrossRefPubMed Wakasa N, Kuramochi T, Mihashi N, Terada N, Kanaji Y, Murai T, et al. Impact of pressure signal drift on fractional flow reserve-based decision-making for patients with intermediate coronary artery stenosis. Circ J. 2016;80:1812–9.CrossRefPubMed
7.
go back to reference Park SJ, Ahn JM, Pijls NH, De Bruyne B, Shim EB, Kim YT, et al. Validation of functional state of coronary tandem lesions using computational flow dynamics. Am J Cardiol. 2012;110:1578–84.CrossRefPubMed Park SJ, Ahn JM, Pijls NH, De Bruyne B, Shim EB, Kim YT, et al. Validation of functional state of coronary tandem lesions using computational flow dynamics. Am J Cardiol. 2012;110:1578–84.CrossRefPubMed
Metadata
Title
Frequency of a large drift caused by pressure wire using optical fibers
Authors
Yoshiaki Kawase
Toru Tanigaki
Akihiro Hirakawa
Hiroyuki Omori
Tetsuo Hirata
Syuuichi Okamoto
Hideaki Ota
Jun Kikuchi
Munenori Okubo
Hiroki Kamiya
Masanori Kawasaki
Takahiko Suzuki
Hitoshi Matsuo
Publication date
01-07-2018
Publisher
Springer Japan
Published in
Cardiovascular Intervention and Therapeutics / Issue 3/2018
Print ISSN: 1868-4300
Electronic ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-017-0481-x

Other articles of this Issue 3/2018

Cardiovascular Intervention and Therapeutics 3/2018 Go to the issue