Abstract

The aim of this study was to compare the stability and clinical outcomes between the two miniplates and sagittal split plate (SSOP) in angle fracture fixation. Thirty-eight patients with a mandibular angle fracture were selected and divided randomly into two groups. Intervention was treated with SSOP, and the control group was treated with conventional two miniplates. Clinical evaluation included occlusion, edema, nerve affection, wound dehiscence and mouth opening. Radiographic parameters included the measurement of inter-ramus distance, inter-mental distance and bone density. All clinical parameters were evaluated at one week, one month and three months intervals. Radiographic parameters were evaluated immediately postoperative, and after three months. Results showed that SSOP had less postoperative complications (10.50%) than the two miniplates (31.60%). It can be concluded that both methods offered high performance in management of mandibular angle fractures. However, SSOP group had a significantly shorter operating time, increased bone density and less edema.
Clinical trial registration number: NCT03839368.
Literature
1.
go back to reference Darwich A, Darwich K, Al-Shurbaji MHD (2016) 3D finite element analysis of miniplate fixation techniques in mandibular angle fractures. J Indian Dent Assoc 9:10 Darwich A, Darwich K, Al-Shurbaji MHD (2016) 3D finite element analysis of miniplate fixation techniques in mandibular angle fractures. J Indian Dent Assoc 9:10
3.
go back to reference Iizuka T, Lindqvist C, Hallikainen D, Paukku P (1991) Infection after rigid internal fixation of mandibular fractures: a clinical and radiologic study. J oral Maxillofac Surg 49(6):585–593CrossRefPubMed Iizuka T, Lindqvist C, Hallikainen D, Paukku P (1991) Infection after rigid internal fixation of mandibular fractures: a clinical and radiologic study. J oral Maxillofac Surg 49(6):585–593CrossRefPubMed
7.
go back to reference Ellis Iii E (1999) Treatment methods for fractures of the mandibular angle. Int J Oral Maxillofac Surg 28(4):243–252CrossRef Ellis Iii E (1999) Treatment methods for fractures of the mandibular angle. Int J Oral Maxillofac Surg 28(4):243–252CrossRef
9.
go back to reference Al-Moraissi EA and 3rd Ellis E (2014) What method for management of unilateral mandibular angle fractures has the lowest rate of postoperative complications? A systematic review and meta-analysis. J Oral Maxillofac Surg Off J Am Assoc Oral Maxillofac Surg. 72(11): 2197–2211. https://doi.org/10.1016/j.joms.2014.05.023 Al-Moraissi EA and 3rd Ellis E (2014) What method for management of unilateral mandibular angle fractures has the lowest rate of postoperative complications? A systematic review and meta-analysis. J Oral Maxillofac Surg Off J Am Assoc Oral Maxillofac Surg. 72(11): 2197–2211. https://​doi.​org/​10.​1016/​j.​joms.​2014.​05.​023
17.
go back to reference Suojanen J, Järvinen S, Hodzic Z, Reunanen J, Leikola J, Stoor P (2019) No differences in infections between patient-specific implants and conventional mini-plates in mandibular bilateral sagittal split osteotomy - Up to 3-year follow-up. J Cranio-Maxillo-Fac Surg Off Publ Eur Assoc Cranio-Maxillo-Fac Surg 47(8):1181–1184. https://doi.org/10.1016/j.jcms.2018.10.009CrossRef Suojanen J, Järvinen S, Hodzic Z, Reunanen J, Leikola J, Stoor P (2019) No differences in infections between patient-specific implants and conventional mini-plates in mandibular bilateral sagittal split osteotomy - Up to 3-year follow-up. J Cranio-Maxillo-Fac Surg Off Publ Eur Assoc Cranio-Maxillo-Fac Surg 47(8):1181–1184. https://​doi.​org/​10.​1016/​j.​jcms.​2018.​10.​009CrossRef
18.
go back to reference Bouchard C, Mansouri M (2017) Open reduction with internal fixation of mandibular angle fractures: a retrospective study. J Can Dent Assoc 82:h3PubMed Bouchard C, Mansouri M (2017) Open reduction with internal fixation of mandibular angle fractures: a retrospective study. J Can Dent Assoc 82:h3PubMed
20.
go back to reference Melek LN, El Mahallawy AS, Sharara AA (2015) Evaluation of the 3-dimensional threadlock plate in the management of mandibular angle fractures: a clinical and radiographic study. Tanta Dent J 12(2):140–148CrossRef Melek LN, El Mahallawy AS, Sharara AA (2015) Evaluation of the 3-dimensional threadlock plate in the management of mandibular angle fractures: a clinical and radiographic study. Tanta Dent J 12(2):140–148CrossRef
22.
go back to reference Singh R, Singh A, Singh DK, Nazeer J, Singh S (2020) Comparative evaluation of 2D miniplates and 3D miniplates fixation in mandibular angle fracture-A clinical study. Indian J Dent Res 31(1):134CrossRefPubMed Singh R, Singh A, Singh DK, Nazeer J, Singh S (2020) Comparative evaluation of 2D miniplates and 3D miniplates fixation in mandibular angle fracture-A clinical study. Indian J Dent Res 31(1):134CrossRefPubMed
Metadata
Title
Stability and Clinical Outcomes of Angle Fracture Fixation Using Sagittal Split Plate (SSOP) Versus Two Miniplates: Randomized Clinical Trial
Authors
Hagar M. El-Sherif
Sherif Ali
Mostafa Talaat
Fahmy Mubarak
Publication date
16-11-2022
Publisher
Springer India
Published in
Journal of Maxillofacial and Oral Surgery / Issue 1/2024
Print ISSN: 0972-8279
Electronic ISSN: 0974-942X
DOI
https://doi.org/10.1007/s12663-022-01817-z

Other articles of this Issue 1/2024

Journal of Maxillofacial and Oral Surgery 1/2024 Go to the issue