Skip to main content
Top
Published in: Current Cardiovascular Imaging Reports 2/2013

01-04-2013 | Technological Advances in Cardiac Multi-modality Imaging (TH Schindler, Section Editor)

Cardiac PET/MRI

Authors: Stephan G. Nekolla, Christoph Rischpler, Anja Batrice, Markus Schwaiger

Published in: Current Cardiovascular Imaging Reports | Issue 2/2013

Login to get access

Abstract

The last decade saw an impressive increase in clinical utilization of hybrid imaging devices such as PET/CT and SPECT/CT, which enhanced the diagnostic quality of many examinations in nuclear medicine. Taking this concept to the integration of PET and MRI was a major technical challenge. Prior to this first generation of whole body scanners, preclinical and brain-only research systems were developed. Accordingly, clinical application is still in its infancy and many potential applications are currently in the proof of principle state. This holds true also for cardiac imaging and thus this review summarizes the core strengths of the individual modality, points to the areas where a synergetic effect is expected and presents initial experience with such a device. However, the additional value and potential clinical role with cardiac hybrid PET/MR imaging have yet to be documented.
Literature
1.
go back to reference Schwaiger M, Ziegler S, Nekolla SG. Pet/ct: challenge for nuclear cardiology. J Nucl Med Soc Nucl Med. 2005;46:1664–78. Schwaiger M, Ziegler S, Nekolla SG. Pet/ct: challenge for nuclear cardiology. J Nucl Med Soc Nucl Med. 2005;46:1664–78.
2.
go back to reference Kajander S, Ukkonen H, Sipila H, Teras M, Knuuti J. Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid pet/ct scanner. Clin Physiol Funct Imaging. 2009;29:81–8.PubMed Kajander S, Ukkonen H, Sipila H, Teras M, Knuuti J. Low radiation dose imaging of myocardial perfusion and coronary angiography with a hybrid pet/ct scanner. Clin Physiol Funct Imaging. 2009;29:81–8.PubMed
3.
go back to reference Souvatzoglou M, Bengel F, Busch R, Kruschke C, Fernolendt H, Lee D, et al. Attenuation correction in cardiac pet/ct with three different ct protocols: a comparison with conventional pet. Eur J Nucl Med Mol Imaging. 2007;34:1991–2000.PubMed Souvatzoglou M, Bengel F, Busch R, Kruschke C, Fernolendt H, Lee D, et al. Attenuation correction in cardiac pet/ct with three different ct protocols: a comparison with conventional pet. Eur J Nucl Med Mol Imaging. 2007;34:1991–2000.PubMed
4.
go back to reference Martinez-Moller A, Souvatzoglou M, Delso G, Bundschuh RA, Chefd'hotel C, Ziegler SI, et al. Tissue classification as a potential approach for attenuation correction in whole-body pet/mri: evaluation with pet/ct data. J Nucl Med Soc Nucl Med. 2009;50:520–6. Martinez-Moller A, Souvatzoglou M, Delso G, Bundschuh RA, Chefd'hotel C, Ziegler SI, et al. Tissue classification as a potential approach for attenuation correction in whole-body pet/mri: evaluation with pet/ct data. J Nucl Med Soc Nucl Med. 2009;50:520–6.
5.
go back to reference Antoch G, Bockisch A. Combined pet/mri: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S113–20.PubMed Antoch G, Bockisch A. Combined pet/mri: a new dimension in whole-body oncology imaging? Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S113–20.PubMed
6.
go back to reference Nekolla SG, Martinez-Moeller A, Saraste A. Pet and mri in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S121–30.PubMed Nekolla SG, Martinez-Moeller A, Saraste A. Pet and mri in cardiac imaging: from validation studies to integrated applications. Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S121–30.PubMed
7.
go back to reference Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P, et al. Design and performance evaluation of a whole-body ingenuity tf pet-mri system. Phys Med Biol. 2011;56:3091–106.PubMed Zaidi H, Ojha N, Morich M, Griesmer J, Hu Z, Maniawski P, et al. Design and performance evaluation of a whole-body ingenuity tf pet-mri system. Phys Med Biol. 2011;56:3091–106.PubMed
8.
go back to reference Delso G, Furst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, et al. Performance measurements of the siemens mmr integrated whole-body pet/mr scanner. J Nucl Med Soc Nucl Med. 2011;52:1914–22. Delso G, Furst S, Jakoby B, Ladebeck R, Ganter C, Nekolla SG, et al. Performance measurements of the siemens mmr integrated whole-body pet/mr scanner. J Nucl Med Soc Nucl Med. 2011;52:1914–22.
9.
go back to reference Hofmann M, Pichler B, Scholkopf B, Beyer T. Towards quantitative pet/mri: a review of mr-based attenuation correction techniques. Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S93–S104.PubMed Hofmann M, Pichler B, Scholkopf B, Beyer T. Towards quantitative pet/mri: a review of mr-based attenuation correction techniques. Eur J Nucl Med Mol Imaging. 2009;36 Suppl 1:S93–S104.PubMed
10.
go back to reference Martinez-Moller A, Souvatzoglou M, Navab N, Schwaiger M, Nekolla SG. Artifacts from misaligned ct in cardiac perfusion pet/ct studies: frequency, effects, and potential solutions. J Nucl Med. 2007;48:188–93.PubMed Martinez-Moller A, Souvatzoglou M, Navab N, Schwaiger M, Nekolla SG. Artifacts from misaligned ct in cardiac perfusion pet/ct studies: frequency, effects, and potential solutions. J Nucl Med. 2007;48:188–93.PubMed
11.
go back to reference Gould KL, Pan T, Loghin C, Johnson NP, Guha A, Sdringola S. Frequent diagnostic errors in cardiac pet/ct due to misregistration of ct attenuation and emission pet images: a definitive analysis of causes, consequences, and corrections. J Nucl Med Soc Nucl Med. 2007;48:1112–21. Gould KL, Pan T, Loghin C, Johnson NP, Guha A, Sdringola S. Frequent diagnostic errors in cardiac pet/ct due to misregistration of ct attenuation and emission pet images: a definitive analysis of causes, consequences, and corrections. J Nucl Med Soc Nucl Med. 2007;48:1112–21.
12.
go back to reference Huang SC, Carson RE, Phelps ME, Hoffman EJ, Schelbert HR, Kuhl DE. A boundary method for attenuation correction in positron computed tomography. J Nucl Med Soc Nucl Med. 1981;22:627–37. Huang SC, Carson RE, Phelps ME, Hoffman EJ, Schelbert HR, Kuhl DE. A boundary method for attenuation correction in positron computed tomography. J Nucl Med Soc Nucl Med. 1981;22:627–37.
13.
go back to reference Coombs BD, Szumowski J, Coshow W. Two-point dixon technique for water-fat signal decomposition with b0 inhomogeneity correction. Mag Res Med Soc Mag Res Med. 1997;38:884–9. Coombs BD, Szumowski J, Coshow W. Two-point dixon technique for water-fat signal decomposition with b0 inhomogeneity correction. Mag Res Med Soc Mag Res Med. 1997;38:884–9.
14.
go back to reference Steinberg J, Jia G, Sammet S, Zhang J, Hall N, Knopp MV. Three-region mri-based whole-body attenuation correction for automated pet reconstruction. Nucl Med Biol. 2010;37:227–35.PubMed Steinberg J, Jia G, Sammet S, Zhang J, Hall N, Knopp MV. Three-region mri-based whole-body attenuation correction for automated pet reconstruction. Nucl Med Biol. 2010;37:227–35.PubMed
15.
go back to reference Schulz V, Torres-Espallardo I, Renisch S, Hu Z, Ojha N, Bornert P, et al. Automatic, three-segment, mr-based attenuation correction for whole-body pet/mr data. Eur J Nucl Med Mol Imaging. 2011;38:138–52.PubMed Schulz V, Torres-Espallardo I, Renisch S, Hu Z, Ojha N, Bornert P, et al. Automatic, three-segment, mr-based attenuation correction for whole-body pet/mr data. Eur J Nucl Med Mol Imaging. 2011;38:138–52.PubMed
16.
go back to reference Samarin A, Burger C, Wollenweber SD, Crook DW, Burger IA, Schmid DT, et al. Pet/mr imaging of bone lesions–implications for pet quantification from imperfect attenuation correction. Eur J Nucl Med Mol Imaging. 2012;39:1154–60.PubMed Samarin A, Burger C, Wollenweber SD, Crook DW, Burger IA, Schmid DT, et al. Pet/mr imaging of bone lesions–implications for pet quantification from imperfect attenuation correction. Eur J Nucl Med Mol Imaging. 2012;39:1154–60.PubMed
17.
go back to reference Fürst S, Souvatzoglu M, Rischpler C, Ziegler S, Schwaiger M, Nekolla S. Effects of mr contrast agents on attenuation map generation and cardiac pet quantification in pet/mr. J Nucl Med. 2012;53 Suppl 1:139. Fürst S, Souvatzoglu M, Rischpler C, Ziegler S, Schwaiger M, Nekolla S. Effects of mr contrast agents on attenuation map generation and cardiac pet quantification in pet/mr. J Nucl Med. 2012;53 Suppl 1:139.
18.
go back to reference Hofmann M, Steinke F, Scheel V, Charpiat G, Farquhar J, Aschoff P, et al. Mri-based attenuation correction for pet/mri: a novel approach combining pattern recognition and atlas registration. J Nucl Med Soc Nucl Med. 2008;49:1875–83. Hofmann M, Steinke F, Scheel V, Charpiat G, Farquhar J, Aschoff P, et al. Mri-based attenuation correction for pet/mri: a novel approach combining pattern recognition and atlas registration. J Nucl Med Soc Nucl Med. 2008;49:1875–83.
19.
go back to reference Schreibmann E, Nye JA, Schuster DM, Martin DR, Votaw J, Fox T. Mr-based attenuation correction for hybrid pet-mr brain imaging systems using deformable image registration. Med Phys. 2010;37:2101–9.PubMed Schreibmann E, Nye JA, Schuster DM, Martin DR, Votaw J, Fox T. Mr-based attenuation correction for hybrid pet-mr brain imaging systems using deformable image registration. Med Phys. 2010;37:2101–9.PubMed
20.
go back to reference Hofmann M, Bezrukov I, Mantlik F, Aschoff P, Steinke F, Beyer T, et al. Mri-based attenuation correction for whole-body pet/mri: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med Soc Nucl Med. 2011;52:1392–9. Hofmann M, Bezrukov I, Mantlik F, Aschoff P, Steinke F, Beyer T, et al. Mri-based attenuation correction for whole-body pet/mri: quantitative evaluation of segmentation- and atlas-based methods. J Nucl Med Soc Nucl Med. 2011;52:1392–9.
21.
go back to reference Censor Y, Gustafson D, Lent A, Tuy H. A new approach to the emission computerized tomography problem: simultaneous calculation of attenuation and activity coefficients. IEEE Trans Nucl Sci. 1979;26:2275–9. Censor Y, Gustafson D, Lent A, Tuy H. A new approach to the emission computerized tomography problem: simultaneous calculation of attenuation and activity coefficients. IEEE Trans Nucl Sci. 1979;26:2275–9.
22.
go back to reference Nuyts J, Dupont P, Stroobants S, Bennick R, Mortelmans L, Suetens P. Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imaging. 1999;18(5):393–403.PubMed Nuyts J, Dupont P, Stroobants S, Bennick R, Mortelmans L, Suetens P. Simultaneous maximum a posteriori reconstruction of attenuation and activity distributions from emission sinograms. IEEE Trans Med Imaging. 1999;18(5):393–403.PubMed
23.
go back to reference Nuyts J, Michel C, Fenchel M, Bal G, Watson C. Completion of a truncated attenuation image from the attenuated pet emission data. IEEE Nucl Sci Symp Conf Record (NSS/MIC) 2010; 2123–7. Nuyts J, Michel C, Fenchel M, Bal G, Watson C. Completion of a truncated attenuation image from the attenuated pet emission data. IEEE Nucl Sci Symp Conf Record (NSS/MIC) 2010; 2123–7.
24.
go back to reference Delso G, Martinez-Moller A, Bundschuh RA, Nekolla SG, Ziegler SI. The effect of limited mr field of view in mr/pet attenuation correction. Med Phys. 2010;37:2804–12.PubMed Delso G, Martinez-Moller A, Bundschuh RA, Nekolla SG, Ziegler SI. The effect of limited mr field of view in mr/pet attenuation correction. Med Phys. 2010;37:2804–12.PubMed
25.
go back to reference Blumhagen JO, Ladebeck R, Fenchel M, Scheffler K. Mr-based field-of-view extension in mr/pet: B(0) homogenization using gradient enhancement (huge). Mag Res Med Soc Mag Res Med. 2012. doi:10.1002/mrm.24555. Blumhagen JO, Ladebeck R, Fenchel M, Scheffler K. Mr-based field-of-view extension in mr/pet: B(0) homogenization using gradient enhancement (huge). Mag Res Med Soc Mag Res Med. 2012. doi:10.​1002/​mrm.​24555.
26.
go back to reference Delso G, Martinez-Moller A, Bundschuh RA, Ladebeck R, Candidus Y, Faul D, et al. Evaluation of the attenuation properties of mr equipment for its use in a whole-body pet/mr scanner. Phys Med Biol. 2010;55:4361–74.PubMed Delso G, Martinez-Moller A, Bundschuh RA, Ladebeck R, Candidus Y, Faul D, et al. Evaluation of the attenuation properties of mr equipment for its use in a whole-body pet/mr scanner. Phys Med Biol. 2010;55:4361–74.PubMed
27.
go back to reference MacDonald LR, Kohlmyer S, Liu C, Lewellen TK, Kinahan PE. Effects of mr surface coils on pet quantification. Med Phys. 2011;38:2948–56.PubMed MacDonald LR, Kohlmyer S, Liu C, Lewellen TK, Kinahan PE. Effects of mr surface coils on pet quantification. Med Phys. 2011;38:2948–56.PubMed
28.
go back to reference Tellmann L, Quick HH, Bockisch A, Herzog H, Beyer T. The effect of mr surface coils on pet quantification in whole-body pet/mr: results from a pseudo-pet/mr phantom study. Med Phys. 2011;38:2795–805.PubMed Tellmann L, Quick HH, Bockisch A, Herzog H, Beyer T. The effect of mr surface coils on pet quantification in whole-body pet/mr: results from a pseudo-pet/mr phantom study. Med Phys. 2011;38:2795–805.PubMed
29.
go back to reference Brogsitter C, Gruning T, Weise R, Wielepp P, Lindner O, Korfer R, et al. 18f-fdg pet for detecting myocardial viability: validation of 3d data acquisition. J Nucl Med Soc Nucl Med. 2005;46:19–24. Brogsitter C, Gruning T, Weise R, Wielepp P, Lindner O, Korfer R, et al. 18f-fdg pet for detecting myocardial viability: validation of 3d data acquisition. J Nucl Med Soc Nucl Med. 2005;46:19–24.
30.
go back to reference Knesaurek K, Machac J, Krynyckyi BR, Almeida OD. Comparison of 2-dimensional and 3-dimensional 82rb myocardial perfusion pet imaging. J Nucl Med Soc Nucl Med. 2003;44:1350–6. Knesaurek K, Machac J, Krynyckyi BR, Almeida OD. Comparison of 2-dimensional and 3-dimensional 82rb myocardial perfusion pet imaging. J Nucl Med Soc Nucl Med. 2003;44:1350–6.
31.
go back to reference Knesaurek K, Machac J, Ho KJ. Comparison of 2d, 3d high dose and 3d low dose gated myocardial 82rb pet imaging. BMC Nucl Med. 2007;7:4.PubMed Knesaurek K, Machac J, Ho KJ. Comparison of 2d, 3d high dose and 3d low dose gated myocardial 82rb pet imaging. BMC Nucl Med. 2007;7:4.PubMed
32.
go back to reference Lekx KS, deKemp RA, Beanlands RS, Wisenberg G, Wells RG, Stodilka RZ, et al. Quantification of regional myocardial blood flow in a canine model of stunned and infarcted myocardium: comparison of rubidium-82 positron emission tomography with microspheres. Nuc Med Commun. 2010;31:67–74. Lekx KS, deKemp RA, Beanlands RS, Wisenberg G, Wells RG, Stodilka RZ, et al. Quantification of regional myocardial blood flow in a canine model of stunned and infarcted myocardium: comparison of rubidium-82 positron emission tomography with microspheres. Nuc Med Commun. 2010;31:67–74.
33.
go back to reference Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, et al. Absolute quantification of myocardial blood flow with 13n-ammonia and 3-dimensional pet. J Nucl Med Soc Nucl Med. 2007;48:1783–9. Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, et al. Absolute quantification of myocardial blood flow with 13n-ammonia and 3-dimensional pet. J Nucl Med Soc Nucl Med. 2007;48:1783–9.
34.
go back to reference DiFilippo FP, Brunken RC. Do implanted pacemaker leads and icd leads cause metal-related artifact in cardiac pet/ct? J Nucl Med. 2005;46:436–43.PubMed DiFilippo FP, Brunken RC. Do implanted pacemaker leads and icd leads cause metal-related artifact in cardiac pet/ct? J Nucl Med. 2005;46:436–43.PubMed
35.
go back to reference Cohen JD, Costa HS, Russo RJ. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators. Am J Cardiol. 2012;110:1631–6.PubMed Cohen JD, Costa HS, Russo RJ. Determining the risks of magnetic resonance imaging at 1.5 tesla for patients with pacemakers and implantable cardioverter defibrillators. Am J Cardiol. 2012;110:1631–6.PubMed
36.
go back to reference Marinskis G, Bongiorni MG, Dagres N, Dobreanu D, Lewalter T, Blomstrom-Lundqvist C. Performing magnetic resonance imaging in patients with implantable pacemakers and defibrillators: results of a european heart rhythm association survey. Europace Eur Soc Cardiol. 2012;14:1807–9. Marinskis G, Bongiorni MG, Dagres N, Dobreanu D, Lewalter T, Blomstrom-Lundqvist C. Performing magnetic resonance imaging in patients with implantable pacemakers and defibrillators: results of a european heart rhythm association survey. Europace Eur Soc Cardiol. 2012;14:1807–9.
37.
go back to reference Henneman MM, van der Wall EE, Ypenburg C, Bleeker GB, van de Veire NR, Marsan NA, et al. Nuclear imaging in cardiac resynchronization therapy. J Nucl Med Soc Nucl Med. 2007;48:2001–10. Henneman MM, van der Wall EE, Ypenburg C, Bleeker GB, van de Veire NR, Marsan NA, et al. Nuclear imaging in cardiac resynchronization therapy. J Nucl Med Soc Nucl Med. 2007;48:2001–10.
38.
go back to reference Uebleis C, Ulbrich M, Tegtmeyer R, Schuessler F, Haserueck N, Siebermair J, et al. Electrocardiogram-gated 18f-fdg pet/ct hybrid imaging in patients with unsatisfactory response to cardiac resynchronization therapy: initial clinical results. J Nucl Med Soc Nucl Med. 2011;52:67–71. Uebleis C, Ulbrich M, Tegtmeyer R, Schuessler F, Haserueck N, Siebermair J, et al. Electrocardiogram-gated 18f-fdg pet/ct hybrid imaging in patients with unsatisfactory response to cardiac resynchronization therapy: initial clinical results. J Nucl Med Soc Nucl Med. 2011;52:67–71.
39.
go back to reference Heyndrickx GR, Millard RW, McRitchie RJ, Maroko PR, Vatner SF. Regional myocardial functional and electrophysiological alterations after brief coronary artery occlusion in conscious dogs. J Clin Invest. 1975;56:978–85.PubMed Heyndrickx GR, Millard RW, McRitchie RJ, Maroko PR, Vatner SF. Regional myocardial functional and electrophysiological alterations after brief coronary artery occlusion in conscious dogs. J Clin Invest. 1975;56:978–85.PubMed
40.
go back to reference Schinkel AF, Poldermans D, Elhendy A, Bax JJ. Assessment of myocardial viability in patients with heart failure. J Nucl Med Soc Nucl Med. 2007;48:1135–46. Schinkel AF, Poldermans D, Elhendy A, Bax JJ. Assessment of myocardial viability in patients with heart failure. J Nucl Med Soc Nucl Med. 2007;48:1135–46.
41.
go back to reference Ghosh N, Rimoldi OE, Beanlands RS, Camici PG. Assessment of myocardial ischaemia and viability: role of positron emission tomography. Eur Heart J. 2010;31:2984–95.PubMed Ghosh N, Rimoldi OE, Beanlands RS, Camici PG. Assessment of myocardial ischaemia and viability: role of positron emission tomography. Eur Heart J. 2010;31:2984–95.PubMed
42.
go back to reference Schinkel AF, Bax JJ, Poldermans D, Elhendy A, Ferrari R, Rahimtoola SH. Hibernating myocardium: diagnosis and patient outcomes. Curr Probl Cardiol. 2007;32:375–410.PubMed Schinkel AF, Bax JJ, Poldermans D, Elhendy A, Ferrari R, Rahimtoola SH. Hibernating myocardium: diagnosis and patient outcomes. Curr Probl Cardiol. 2007;32:375–410.PubMed
43.
go back to reference vom Dahl J, Eitzman DT, al-Aouar ZR, Kanter HL, Hicks RJ, Deeb GM, et al. Relation of regional function, perfusion, and metabolism in patients with advanced coronary artery disease undergoing surgical revascularization. Circulation. 1994;90:2356–66. vom Dahl J, Eitzman DT, al-Aouar ZR, Kanter HL, Hicks RJ, Deeb GM, et al. Relation of regional function, perfusion, and metabolism in patients with advanced coronary artery disease undergoing surgical revascularization. Circulation. 1994;90:2356–66.
44.
go back to reference Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, et al. Reversibility of cardiac wall-motion abnormalities predicted by positron tomography. N Engl J Med. 1986;314:884–8.PubMed Tillisch J, Brunken R, Marshall R, Schwaiger M, Mandelkern M, Phelps M, et al. Reversibility of cardiac wall-motion abnormalities predicted by positron tomography. N Engl J Med. 1986;314:884–8.PubMed
45.
go back to reference Klein C, Nekolla SG, Balbach T, Schnackenburg B, Nagel E, Fleck E, et al. The influence of myocardial blood flow and volume of distribution on late gd-dtpa kinetics in ischemic heart failure. J Magn Reson Imaging. 2004;20:588–93.PubMed Klein C, Nekolla SG, Balbach T, Schnackenburg B, Nagel E, Fleck E, et al. The influence of myocardial blood flow and volume of distribution on late gd-dtpa kinetics in ischemic heart failure. J Magn Reson Imaging. 2004;20:588–93.PubMed
46.
go back to reference Klein C, Schmal TR, Nekolla SG, Schnackenburg B, Fleck E, Nagel E. Mechanism of late gadolinium enhancement in patients with acute myocardial infarction. J Cardiovasc Mag Res. 2007;9:653–8. Klein C, Schmal TR, Nekolla SG, Schnackenburg B, Fleck E, Nagel E. Mechanism of late gadolinium enhancement in patients with acute myocardial infarction. J Cardiovasc Mag Res. 2007;9:653–8.
47.
go back to reference Klein C, Nekolla SG, Bengel FM, Momose M, Sammer A, Haas F, et al. Assessment of myocardial viability with contrast-enhanced magnetic resonance imaging: comparison with positron emission tomography. Circulation. 2002;105:162–7.PubMed Klein C, Nekolla SG, Bengel FM, Momose M, Sammer A, Haas F, et al. Assessment of myocardial viability with contrast-enhanced magnetic resonance imaging: comparison with positron emission tomography. Circulation. 2002;105:162–7.PubMed
48.
go back to reference Kwong RY, Chan AK, Brown KA, Chan CW, Reynolds HG, Tsang S, et al. Impact of unrecognized myocardial scar detected by cardiac magnetic resonance imaging on event-free survival in patients presenting with signs or symptoms of coronary artery disease. Circulation. 2006;113:2733–43.PubMed Kwong RY, Chan AK, Brown KA, Chan CW, Reynolds HG, Tsang S, et al. Impact of unrecognized myocardial scar detected by cardiac magnetic resonance imaging on event-free survival in patients presenting with signs or symptoms of coronary artery disease. Circulation. 2006;113:2733–43.PubMed
49.
go back to reference Wagner A, Mahrholdt H, Holly TA, Elliott MD, Regenfus M, Parker M, et al. Contrast-enhanced mri and routine single photon emission computed tomography (spect) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study. Lancet. 2003;361:374–9.PubMed Wagner A, Mahrholdt H, Holly TA, Elliott MD, Regenfus M, Parker M, et al. Contrast-enhanced mri and routine single photon emission computed tomography (spect) perfusion imaging for detection of subendocardial myocardial infarcts: an imaging study. Lancet. 2003;361:374–9.PubMed
50.
go back to reference Schmidt M, Voth E, Schneider CA, Theissen P, Wagner R, Baer FM, et al. F-18-fdg uptake is a reliable predictory of functional recovery of akinetic but viable infarct regions as defined by magnetic resonance imaging before and after revascularization. Magn Reson Imaging. 2004;22:229–36.PubMed Schmidt M, Voth E, Schneider CA, Theissen P, Wagner R, Baer FM, et al. F-18-fdg uptake is a reliable predictory of functional recovery of akinetic but viable infarct regions as defined by magnetic resonance imaging before and after revascularization. Magn Reson Imaging. 2004;22:229–36.PubMed
51.
go back to reference Gerber BL, Rochitte CE, Bluemke DA, Melin JA, Crosille P, Becker LC, et al. Relation between gd-dtpa contrast enhancement and regional inotropic response in the periphery and center of myocardial infarction. Circulation. 2001;104:998–1004.PubMed Gerber BL, Rochitte CE, Bluemke DA, Melin JA, Crosille P, Becker LC, et al. Relation between gd-dtpa contrast enhancement and regional inotropic response in the periphery and center of myocardial infarction. Circulation. 2001;104:998–1004.PubMed
52.
go back to reference Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. Acc/aha/asnc guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the american college of cardiology/american heart association task force on practice guidelines (acc/aha/asnc committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging). J Am Coll Cardiol. 2003;42:1318–33.PubMed Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, et al. Acc/aha/asnc guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the american college of cardiology/american heart association task force on practice guidelines (acc/aha/asnc committee to revise the 1995 guidelines for the clinical use of cardiac radionuclide imaging). J Am Coll Cardiol. 2003;42:1318–33.PubMed
53.
go back to reference Fukushima K, Javadi MS, Higuchi T, Lautamaki R, Merrill J, Nekolla SG, et al. Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82rb pet perfusion imaging. J Nucl Med. 2011;52:726–32.PubMed Fukushima K, Javadi MS, Higuchi T, Lautamaki R, Merrill J, Nekolla SG, et al. Prediction of short-term cardiovascular events using quantification of global myocardial flow reserve in patients referred for clinical 82rb pet perfusion imaging. J Nucl Med. 2011;52:726–32.PubMed
54.
go back to reference Yoshinaga K, Chow BJ, Williams K, Chen L, deKemp RA, Garrard L, et al. What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Cardiol. 2006;48:1029–39.PubMed Yoshinaga K, Chow BJ, Williams K, Chen L, deKemp RA, Garrard L, et al. What is the prognostic value of myocardial perfusion imaging using rubidium-82 positron emission tomography? J Am Coll Cardiol. 2006;48:1029–39.PubMed
55.
go back to reference Merhige ME, Breen WJ, Shelton V, Houston T, D'Arcy BJ, Perna AF. Impact of myocardial perfusion imaging with pet and (82)rb on downstream invasive procedure utilization, costs, and outcomes in coronary disease management. J Nucl Med Soc Nucl Med. 2007;48:1069–76. Merhige ME, Breen WJ, Shelton V, Houston T, D'Arcy BJ, Perna AF. Impact of myocardial perfusion imaging with pet and (82)rb on downstream invasive procedure utilization, costs, and outcomes in coronary disease management. J Nucl Med Soc Nucl Med. 2007;48:1069–76.
56.
go back to reference Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107:2900–7.PubMed Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Comparison of the short-term survival benefit associated with revascularization compared with medical therapy in patients with no prior coronary artery disease undergoing stress myocardial perfusion single photon emission computed tomography. Circulation. 2003;107:2900–7.PubMed
57.
go back to reference Flotats A, Bravo PE, Fukushima K, Chaudhry MA, Merrill J, Bengel FM. (82)rb pet myocardial perfusion imaging is superior to (99m)tc-labelled agent spect in patients with known or suspected coronary artery disease. Eur J Nucl Med Mol Imaging. 2012;39(8):1233–9. doi:10.1007/s00259-012-2140-x.PubMed Flotats A, Bravo PE, Fukushima K, Chaudhry MA, Merrill J, Bengel FM. (82)rb pet myocardial perfusion imaging is superior to (99m)tc-labelled agent spect in patients with known or suspected coronary artery disease. Eur J Nucl Med Mol Imaging. 2012;39(8):1233–9. doi:10.​1007/​s00259-012-2140-x.PubMed
58.
go back to reference Bateman TM, Heller GV, McGhie AI, Friedman JD, Case JA, Bryngelson JR, et al. Diagnostic accuracy of rest/stress ecg-gated rb-82 myocardial perfusion pet: comparison with ecg-gated tc-99 m sestamibi spect. J Nucl Cardiol. 2006;13:24–33.PubMed Bateman TM, Heller GV, McGhie AI, Friedman JD, Case JA, Bryngelson JR, et al. Diagnostic accuracy of rest/stress ecg-gated rb-82 myocardial perfusion pet: comparison with ecg-gated tc-99 m sestamibi spect. J Nucl Cardiol. 2006;13:24–33.PubMed
59.
go back to reference Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, et al. Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography. Circulation. 2001;103:2230–5.PubMed Schwitter J, Nanz D, Kneifel S, Bertschinger K, Buchi M, Knusel PR, et al. Assessment of myocardial perfusion in coronary artery disease by magnetic resonance: a comparison with positron emission tomography and coronary angiography. Circulation. 2001;103:2230–5.PubMed
60.
go back to reference Ibrahim T, Nekolla SG, Schreiber K, Odaka K, Volz S, Mehilli J, et al. Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography. J Am Coll Cardiol. 2002;39:864–70.PubMed Ibrahim T, Nekolla SG, Schreiber K, Odaka K, Volz S, Mehilli J, et al. Assessment of coronary flow reserve: comparison between contrast-enhanced magnetic resonance imaging and positron emission tomography. J Am Coll Cardiol. 2002;39:864–70.PubMed
61.
go back to reference Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, et al. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J Am Coll Cardiol. 2012;60:1546–55.PubMed Morton G, Chiribiri A, Ishida M, Hussain ST, Schuster A, Indermuehle A, et al. Quantification of absolute myocardial perfusion in patients with coronary artery disease: comparison between cardiovascular magnetic resonance and positron emission tomography. J Am Coll Cardiol. 2012;60:1546–55.PubMed
62.
go back to reference Manning WJ, Atkinson DJ, Grossman W, Paulin S, Edelman RR. First-pass nuclear magnetic resonance imaging studies using gadolinium-dtpa in patients with coronary artery disease. J Am Coll Cardiol. 1991;18:959–65.PubMed Manning WJ, Atkinson DJ, Grossman W, Paulin S, Edelman RR. First-pass nuclear magnetic resonance imaging studies using gadolinium-dtpa in patients with coronary artery disease. J Am Coll Cardiol. 1991;18:959–65.PubMed
63.
go back to reference Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2007;50:1343–53.PubMed Nandalur KR, Dwamena BA, Choudhri AF, Nandalur MR, Carlos RC. Diagnostic performance of stress cardiac magnetic resonance imaging in the detection of coronary artery disease: a meta-analysis. J Am Coll Cardiol. 2007;50:1343–53.PubMed
64.
go back to reference de Jong MC, Genders TS, van Geuns RJ, Moelker A, Hunink MG. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. Eur Radiol. 2012;22(9):1881–95. doi:10.1007/s00330-012-2434-1.PubMed de Jong MC, Genders TS, van Geuns RJ, Moelker A, Hunink MG. Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis. Eur Radiol. 2012;22(9):1881–95. doi:10.​1007/​s00330-012-2434-1.PubMed
65.
go back to reference Parkash R, deKemp RA, Ruddy TD, Kitsikis A, Hart R, Beauchesne L, et al. Potential utility of rubidium 82 pet quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol. 2004;11:440–9.PubMed Parkash R, deKemp RA, Ruddy TD, Kitsikis A, Hart R, Beauchesne L, et al. Potential utility of rubidium 82 pet quantification in patients with 3-vessel coronary artery disease. J Nucl Cardiol. 2004;11:440–9.PubMed
66.
go back to reference Kajander SA, Joutsiniemi E, Saraste M, Pietila M, Ukkonen H, Saraste A, et al. Clinical value of absolute quantification of myocardial perfusion with (15)o-water in coronary artery disease. Circ Cardiovasc Imaging. 2011;4:678–84.PubMed Kajander SA, Joutsiniemi E, Saraste M, Pietila M, Ukkonen H, Saraste A, et al. Clinical value of absolute quantification of myocardial perfusion with (15)o-water in coronary artery disease. Circ Cardiovasc Imaging. 2011;4:678–84.PubMed
67.
go back to reference Schwaiger M, Melin J. Cardiological applications of nuclear medicine. Lancet. 1999;354:661–6.PubMed Schwaiger M, Melin J. Cardiological applications of nuclear medicine. Lancet. 1999;354:661–6.PubMed
68.
go back to reference Jerosch-Herold M. Quantification of myocardial perfusion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson Off J Soc Cardiovasc Magn Reson. 2010;12:57. Jerosch-Herold M. Quantification of myocardial perfusion by cardiovascular magnetic resonance. J Cardiovasc Magn Reson Off J Soc Cardiovasc Magn Reson. 2010;12:57.
69.
go back to reference Zierler K. Indicator dilution methods for measuring blood flow, volume, and other properties of biological systems: a brief history and memoir. Ann Biomed Eng. 2000;28:836–48.PubMed Zierler K. Indicator dilution methods for measuring blood flow, volume, and other properties of biological systems: a brief history and memoir. Ann Biomed Eng. 2000;28:836–48.PubMed
70.
go back to reference Ishida M, Schuster A, Morton G, Chiribiri A, Hussain S, Paul M, et al. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Mag Res. 2011;13:28. Ishida M, Schuster A, Morton G, Chiribiri A, Hussain S, Paul M, et al. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Mag Res. 2011;13:28.
71.
go back to reference Choi Y, Huang SC, Hawkins RA, Kuhle WG, Dahlbom M, Hoh CK, et al. A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic pet. J Nucl Med Soc Nucl Med. 1993;34:488–97. Choi Y, Huang SC, Hawkins RA, Kuhle WG, Dahlbom M, Hoh CK, et al. A simplified method for quantification of myocardial blood flow using nitrogen-13-ammonia and dynamic pet. J Nucl Med Soc Nucl Med. 1993;34:488–97.
72.
go back to reference McCommis KS, Zhang H, Herrero P, Gropler RJ, Zheng J. Feasibility study of myocardial perfusion and oxygenation by noncontrast mri: comparison with pet study in a canine model. Magn Reson Imaging. 2008;26:11–9.PubMed McCommis KS, Zhang H, Herrero P, Gropler RJ, Zheng J. Feasibility study of myocardial perfusion and oxygenation by noncontrast mri: comparison with pet study in a canine model. Magn Reson Imaging. 2008;26:11–9.PubMed
73.
go back to reference Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Mag Res. 2000;2:271–8. Bellenger NG, Davies LC, Francis JM, Coats AJ, Pennell DJ. Reduction in sample size for studies of remodeling in heart failure by the use of cardiovascular magnetic resonance. J Cardiovasc Mag Res. 2000;2:271–8.
74.
go back to reference Boyd HL, Gunn RN, Marinho NVS, Karwatowski SP, Bailey DL, Costa DC, et al. Non-invasive measurement of left ventricular volumes and function by gated positron emission tomography. Eur J Nucl Med. 1996;23:1594–602.PubMed Boyd HL, Gunn RN, Marinho NVS, Karwatowski SP, Bailey DL, Costa DC, et al. Non-invasive measurement of left ventricular volumes and function by gated positron emission tomography. Eur J Nucl Med. 1996;23:1594–602.PubMed
75.
go back to reference Rajappan K, Livieratos L, Camici PG, Pennell DJ. Measurement of ventricular volumes and function: a comparison of gated pet and cardiovascular magnetic resonance. J Nucl Med. 2002;43:806–10.PubMed Rajappan K, Livieratos L, Camici PG, Pennell DJ. Measurement of ventricular volumes and function: a comparison of gated pet and cardiovascular magnetic resonance. J Nucl Med. 2002;43:806–10.PubMed
76.
go back to reference Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, et al. Estimated radiation dose associated with cardiac ct angiography. JAMA J Am Med Assoc. 2009;301:500–7. Hausleiter J, Meyer T, Hermann F, Hadamitzky M, Krebs M, Gerber TC, et al. Estimated radiation dose associated with cardiac ct angiography. JAMA J Am Med Assoc. 2009;301:500–7.
77.
go back to reference Thompson RC, Cullom SJ. Issues regarding radiation dosage of cardiac nuclear and radiography procedures. J Nucl Cardiol. 2006;13:19–23.PubMed Thompson RC, Cullom SJ. Issues regarding radiation dosage of cardiac nuclear and radiography procedures. J Nucl Cardiol. 2006;13:19–23.PubMed
78.
go back to reference Fink C, Krissak R, Henzler T, Lechel U, Brix G, Takx RA, et al. Radiation dose at coronary ct angiography: second-generation dual-source ct versus single-source 64-mdct and first-generation dual-source ct. AJR Am J Roentgenol. 2011;196:W550–7.PubMed Fink C, Krissak R, Henzler T, Lechel U, Brix G, Takx RA, et al. Radiation dose at coronary ct angiography: second-generation dual-source ct versus single-source 64-mdct and first-generation dual-source ct. AJR Am J Roentgenol. 2011;196:W550–7.PubMed
79.
go back to reference Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001;345:1863–9.PubMed Kim WY, Danias PG, Stuber M, Flamm SD, Plein S, Nagel E, et al. Coronary magnetic resonance angiography for the detection of coronary stenoses. N Engl J Med. 2001;345:1863–9.PubMed
80.
go back to reference Yoon YE, Kitagawa K, Kato S, Ishida M, Nakajima H, Kurita T, et al. Prognostic value of coronary magnetic resonance angiography for prediction of cardiac events in patients with suspected coronary artery disease. J Am Coll Cardiol. 2012;60(22):2316–22. doi:10.1016/j.jacc.2012.07.060.PubMed Yoon YE, Kitagawa K, Kato S, Ishida M, Nakajima H, Kurita T, et al. Prognostic value of coronary magnetic resonance angiography for prediction of cardiac events in patients with suspected coronary artery disease. J Am Coll Cardiol. 2012;60(22):2316–22. doi:10.​1016/​j.​jacc.​2012.​07.​060.PubMed
81.
go back to reference Fayad ZA, Fuster V, Fallon JT, Jayasundera T, Worthley SG, Helft G, et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation. 2000;102:506–10.PubMed Fayad ZA, Fuster V, Fallon JT, Jayasundera T, Worthley SG, Helft G, et al. Noninvasive in vivo human coronary artery lumen and wall imaging using black-blood magnetic resonance imaging. Circulation. 2000;102:506–10.PubMed
82.
go back to reference Kim WY, Stuber M, Bornert P, Kissinger KV, Manning WJ, Botnar RM. Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease. Circulation. 2002;106:296–9.PubMed Kim WY, Stuber M, Bornert P, Kissinger KV, Manning WJ, Botnar RM. Three-dimensional black-blood cardiac magnetic resonance coronary vessel wall imaging detects positive arterial remodeling in patients with nonsignificant coronary artery disease. Circulation. 2002;106:296–9.PubMed
83.
go back to reference Ibrahim T, Makowski MR, Jankauskas A, Maintz D, Karch M, Schachoff S, et al. Serial contrast-enhanced cardiac magnetic resonance imaging demonstrates regression of hyperenhancement within the coronary artery wall in patients after acute myocardial infarction. JACC. Cardiovasc Imaging. 2009;2:580–8. Ibrahim T, Makowski MR, Jankauskas A, Maintz D, Karch M, Schachoff S, et al. Serial contrast-enhanced cardiac magnetic resonance imaging demonstrates regression of hyperenhancement within the coronary artery wall in patients after acute myocardial infarction. JACC. Cardiovasc Imaging. 2009;2:580–8.
84.
go back to reference Haubner R, Beer AJ, Wang H, Chen X. Positron emission tomography tracers for imaging angiogenesis. Eur J Nucl Med Mol Imaging. 2010;37 Suppl 1:S86–S103.PubMed Haubner R, Beer AJ, Wang H, Chen X. Positron emission tomography tracers for imaging angiogenesis. Eur J Nucl Med Mol Imaging. 2010;37 Suppl 1:S86–S103.PubMed
85.
go back to reference Haubner R, Weber WA, Beer AJ, Vabuliene E, Reim D, Sarbia M, et al. Noninvasive visualization of the activated alphavbeta3 integrin in cancer patients by positron emission tomography and [18f]galacto-rgd. PLoS Med. 2005;2:e70.PubMed Haubner R, Weber WA, Beer AJ, Vabuliene E, Reim D, Sarbia M, et al. Noninvasive visualization of the activated alphavbeta3 integrin in cancer patients by positron emission tomography and [18f]galacto-rgd. PLoS Med. 2005;2:e70.PubMed
86.
go back to reference Winter PM, Morawski AM, Caruthers SD, Fuhrhop RW, Zhang H, Williams TA, et al. Molecular imaging of angiogenesis in early-stage atherosclerosis with alpha(v)beta3-integrin-targeted nanoparticles. Circulation. 2003;108:2270–4.PubMed Winter PM, Morawski AM, Caruthers SD, Fuhrhop RW, Zhang H, Williams TA, et al. Molecular imaging of angiogenesis in early-stage atherosclerosis with alpha(v)beta3-integrin-targeted nanoparticles. Circulation. 2003;108:2270–4.PubMed
87.
go back to reference Sipkins DA, Cheresh DA, Kazemi MR, Nevin LM, Bednarski MD, Li KC. Detection of tumor angiogenesis in vivo by alphavbeta3-targeted magnetic resonance imaging. Nat Med. 1998;4:623–6.PubMed Sipkins DA, Cheresh DA, Kazemi MR, Nevin LM, Bednarski MD, Li KC. Detection of tumor angiogenesis in vivo by alphavbeta3-targeted magnetic resonance imaging. Nat Med. 1998;4:623–6.PubMed
88.
go back to reference Holloway C, Clarke K. Is mr spectroscopy of the heart ready for humans? Heart Lung Circ. 2010;19:154–60.PubMed Holloway C, Clarke K. Is mr spectroscopy of the heart ready for humans? Heart Lung Circ. 2010;19:154–60.PubMed
89.
go back to reference Bottomley PA, Weiss RG. Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium. Lancet. 1998;351:714–8.PubMed Bottomley PA, Weiss RG. Non-invasive magnetic-resonance detection of creatine depletion in non-viable infarcted myocardium. Lancet. 1998;351:714–8.PubMed
90.
go back to reference Szczepaniak LS, Dobbins RL, Metzger GJ, Sartoni-D'Ambrosia G, Arbique D, Vongpatanasin W, et al. Myocardial triglycerides and systolic function in humans: In vivo evaluation by localized proton spectroscopy and cardiac imaging. Mag Res Med Soc Mag Res Med. 2003;49:417–23. Szczepaniak LS, Dobbins RL, Metzger GJ, Sartoni-D'Ambrosia G, Arbique D, Vongpatanasin W, et al. Myocardial triglycerides and systolic function in humans: In vivo evaluation by localized proton spectroscopy and cardiac imaging. Mag Res Med Soc Mag Res Med. 2003;49:417–23.
91.
go back to reference Jansen MA, Van Emous JG, Nederhoff MG, Van Echteld CJ. Assessment of myocardial viability by intracellular 23na magnetic resonance imaging. Circulation. 2004;110:3457–64.PubMed Jansen MA, Van Emous JG, Nederhoff MG, Van Echteld CJ. Assessment of myocardial viability by intracellular 23na magnetic resonance imaging. Circulation. 2004;110:3457–64.PubMed
92.
go back to reference Wedeen VJ, Hagmann P, Tseng WY, Reese TG, Weisskoff RM. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Mag Res Med Soc Mag Res Med. 2005;54:1377–86. Wedeen VJ, Hagmann P, Tseng WY, Reese TG, Weisskoff RM. Mapping complex tissue architecture with diffusion spectrum magnetic resonance imaging. Mag Res Med Soc Mag Res Med. 2005;54:1377–86.
93.
go back to reference Sosnovik DE, Wang R, Dai G, Wang T, Aikawa E, Novikov M, et al. Diffusion spectrum mri tractography reveals the presence of a complex network of residual myofibers in infarcted myocardium. Circ Cardiovasc Imaging. 2009;2:206–12.PubMed Sosnovik DE, Wang R, Dai G, Wang T, Aikawa E, Novikov M, et al. Diffusion spectrum mri tractography reveals the presence of a complex network of residual myofibers in infarcted myocardium. Circ Cardiovasc Imaging. 2009;2:206–12.PubMed
94.
go back to reference Drzezga A, Souvatzoglou M, Eiber M, Beer AJ, Furst S, Martinez-Moller A, et al. First clinical experience with integrated whole-body pet/mr: comparison to pet/ct in patients with oncologic diagnoses. J Nucl Med Soc Nucl Med. 2012;53:845–55. Drzezga A, Souvatzoglou M, Eiber M, Beer AJ, Furst S, Martinez-Moller A, et al. First clinical experience with integrated whole-body pet/mr: comparison to pet/ct in patients with oncologic diagnoses. J Nucl Med Soc Nucl Med. 2012;53:845–55.
95.
go back to reference Eiber M, Souvatzoglou M, Pickhard A, Loeffelbein DJ, Knopf A, Holzapfel K, et al. Simulation of a mr-pet protocol for staging of head-and-neck cancer including dixon mr for attenuation correction. Eur J Radiol. 2012;81:2658–65.PubMed Eiber M, Souvatzoglou M, Pickhard A, Loeffelbein DJ, Knopf A, Holzapfel K, et al. Simulation of a mr-pet protocol for staging of head-and-neck cancer including dixon mr for attenuation correction. Eur J Radiol. 2012;81:2658–65.PubMed
96.
go back to reference Martinez-Moller A, Eiber M, Nekolla SG, Souvatzoglou M, Drzezga A, Ziegler S, et al. Workflow and scan protocol considerations for integrated whole-body pet/mri in oncology. J Nucl Med Soc Nucl Med. 2012;53:1415–26. Martinez-Moller A, Eiber M, Nekolla SG, Souvatzoglou M, Drzezga A, Ziegler S, et al. Workflow and scan protocol considerations for integrated whole-body pet/mri in oncology. J Nucl Med Soc Nucl Med. 2012;53:1415–26.
97.
go back to reference Adluru G, Chen L, Kim SE, Burgon N, Kholmovski EG, Marrouche NF, et al. Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing. JMRI. 2011;34:1465–71.PubMed Adluru G, Chen L, Kim SE, Burgon N, Kholmovski EG, Marrouche NF, et al. Three-dimensional late gadolinium enhancement imaging of the left atrium with a hybrid radial acquisition and compressed sensing. JMRI. 2011;34:1465–71.PubMed
98.
go back to reference Xue H, Zuehlsdorff S, Kellman P, Arai A, Nielles-Vallespin S, Chefdhotel C, et al. Unsupervised inline analysis of cardiac perfusion mri. Medical image computing and computer-assisted intervention: MICCAI …. Int Conf Med Image Comput Computer-Assisted Interv. 2009;12:741–9. Xue H, Zuehlsdorff S, Kellman P, Arai A, Nielles-Vallespin S, Chefdhotel C, et al. Unsupervised inline analysis of cardiac perfusion mri. Medical image computing and computer-assisted intervention: MICCAI …. Int Conf Med Image Comput Computer-Assisted Interv. 2009;12:741–9.
99.
go back to reference Reeps C, Bundschuh RA, Pellisek J, Herz M, van Marwick S, Schwaiger M, Eckstein HH, Nekolla SG, Essler M. Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction. Int J Cardiovasc Imaging. 2012;Jul 7. [Epub ahead of print]. Reeps C, Bundschuh RA, Pellisek J, Herz M, van Marwick S, Schwaiger M, Eckstein HH, Nekolla SG, Essler M. Quantitative assessment of glucose metabolism in the vessel wall of abdominal aortic aneurysms: correlation with histology and role of partial volume correction. Int J Cardiovasc Imaging. 2012;Jul 7. [Epub ahead of print].
100.
go back to reference Lautamaki R, Schuleri KH, Sasano T, Javadi MS, Youssef A, Merrill J, et al. Integration of infarct size, tissue perfusion, and metabolism by hybrid cardiac positron emission tomography/computed tomography: evaluation in a porcine model of myocardial infarction. Circ Cardiovasc Imaging. 2009;2:299–305.PubMed Lautamaki R, Schuleri KH, Sasano T, Javadi MS, Youssef A, Merrill J, et al. Integration of infarct size, tissue perfusion, and metabolism by hybrid cardiac positron emission tomography/computed tomography: evaluation in a porcine model of myocardial infarction. Circ Cardiovasc Imaging. 2009;2:299–305.PubMed
Metadata
Title
Cardiac PET/MRI
Authors
Stephan G. Nekolla
Christoph Rischpler
Anja Batrice
Markus Schwaiger
Publication date
01-04-2013
Publisher
Current Science Inc.
Published in
Current Cardiovascular Imaging Reports / Issue 2/2013
Print ISSN: 1941-9066
Electronic ISSN: 1941-9074
DOI
https://doi.org/10.1007/s12410-013-9190-8

Other articles of this Issue 2/2013

Current Cardiovascular Imaging Reports 2/2013 Go to the issue

Technological Advances in Cardiac Multi-modality Imaging (TH Schindler, Section Editor)

Cardiac PET-CT and CT Angiography

Technological Advances in Cardiac Multi-modality Imaging (TH Schindler, Section Editor)

Cardiac PET/MRI

Cardiac Magnetic Resonance (E Nagel, Section Editor)

Clinical Applications of Aortic 4D Flow Imaging