Skip to main content
Top
Published in: Journal of Nuclear Cardiology 4/2020

01-08-2020 | Angiography | Original Article

Ventricular peak emptying and filling rates measured by gated tomographic radionuclide angiography using a cadmium–zinc–telluride SPECT camera in chemotherapy-naïve cancer patients

Authors: Naja Liv Hansen, MD, PhD, Christian Haarmark, MD, PhD, Bo Zerahn, MD

Published in: Journal of Nuclear Cardiology | Issue 4/2020

Login to get access

Abstract

Introduction

Radionuclide angiography is widely used for left ventricular function assessment. This study establishes normative data and inter-study repeatability on peak ventricular filling and emptying rates obtained by a cadmium–zinc–telluride SPECT camera.

Method

Cancer patients (N = 764) without diabetes or cardiovascular diseases referred for baseline assessment of cardiac function were included. Repeatability was assessed in 46 patients where two separate acquisitions were performed. Left and right ventricular emptying rates (LPER, RPER) and filling rates (LPFR, RPFR) were obtained and whenever possible also atrial filling rates (PFRa).

Results

Filling rates were higher in women than men. Emptying rates tended to increase with age, whereas filling rates and the E/A ratio decreased. One patient was excluded from the repeatability analysis due to an unexplained high intra-observer variation. Intraclass correlation coefficients for LPER, RPER, LPFR, and RPFR were 0.99, 0.94, 0.99, and 0.84, no proportional biases were detected.

Conclusion

Reference values and relations to age and gender in chemotherapy-naïve cancer patients without cardiopulmonary disease are presented. The CZT camera provides reproducible estimates of peak emptying and filling rates.
Appendix
Available only for authorised users
Literature
1.
go back to reference Carver JR, Shapiro CL, Ng A, et al. American Society of Clinical Oncology clinical evidence review on the ongoing care of adult cancer survivors : Cardiac and pulmonary late effects late effects of cancer. J Clin Oncol 2016;25:3991-4008.CrossRef Carver JR, Shapiro CL, Ng A, et al. American Society of Clinical Oncology clinical evidence review on the ongoing care of adult cancer survivors : Cardiac and pulmonary late effects late effects of cancer. J Clin Oncol 2016;25:3991-4008.CrossRef
2.
go back to reference Curigliano G, Cardinale D, Suter T, et al. Cardiovascular toxicity induced by chemotherapy, targeted agents and radiotherapy: ESMO clinical practice guidelines. Ann Oncol 2012;23:155-66.CrossRef Curigliano G, Cardinale D, Suter T, et al. Cardiovascular toxicity induced by chemotherapy, targeted agents and radiotherapy: ESMO clinical practice guidelines. Ann Oncol 2012;23:155-66.CrossRef
3.
go back to reference Zamorano JL, Lancellotti P, Muñoz DR, et al. 2016 ESC position paper on cancer treatments and cardiovascular toxicity developed under the auspices of the ESC committee for practice guidelines: The task force for cancer treatments and cardiovascular toxicity of the european society of cardiology (ESC.). Russ J Cardiol 2017;143:105-39. Zamorano JL, Lancellotti P, Muñoz DR, et al. 2016 ESC position paper on cancer treatments and cardiovascular toxicity developed under the auspices of the ESC committee for practice guidelines: The task force for cancer treatments and cardiovascular toxicity of the european society of cardiology (ESC.). Russ J Cardiol 2017;143:105-39.
4.
go back to reference de Geus-Oei L-F, Mavinkurve-Groothuis AMC, Bellersen L, et al. Scintigraphic techniques for early detection of cancer treatment-induced cardiotoxicity. J Nucl Med Technol 2013;41:170-81.CrossRef de Geus-Oei L-F, Mavinkurve-Groothuis AMC, Bellersen L, et al. Scintigraphic techniques for early detection of cancer treatment-induced cardiotoxicity. J Nucl Med Technol 2013;41:170-81.CrossRef
5.
go back to reference Nagiub M, Nixon JV, Kontos MC. Ability of nonstrain diastolic parameters to predict doxorubicin-induced cardiomyopathy: A systematic review with meta-analysis. Cardiol Rev 2018;26:29-34.CrossRef Nagiub M, Nixon JV, Kontos MC. Ability of nonstrain diastolic parameters to predict doxorubicin-induced cardiomyopathy: A systematic review with meta-analysis. Cardiol Rev 2018;26:29-34.CrossRef
6.
go back to reference Ong G, Brezden-Masley C, Dhir V, et al. Myocardial strain imaging by cardiac magnetic resonance for detection of subclinical myocardial dysfunction in breast cancer patients receiving trastuzumab and chemotherapy. Int J Cardiol 2018;261:228-33.CrossRef Ong G, Brezden-Masley C, Dhir V, et al. Myocardial strain imaging by cardiac magnetic resonance for detection of subclinical myocardial dysfunction in breast cancer patients receiving trastuzumab and chemotherapy. Int J Cardiol 2018;261:228-33.CrossRef
7.
go back to reference Nair N, Gongora E. Heart failure in chemotherapy-related cardiomyopathy: Can exercise make a difference? BBA Clin 2016;6:69-75.CrossRef Nair N, Gongora E. Heart failure in chemotherapy-related cardiomyopathy: Can exercise make a difference? BBA Clin 2016;6:69-75.CrossRef
8.
go back to reference Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 2016;29:277-314.CrossRef Nagueh SF, Smiseth OA, Appleton CP, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography: An Update from the American Society of Echocardiography and the European Association of Cardiovascular Imaging. J Am Soc Echocardiogr 2016;29:277-314.CrossRef
9.
go back to reference Bocher M, Blevis IM, Tsukerman L, et al. A fast cardiac gamma camera with dynamic SPECT capabilities: Design, system validation and future potential. Eur J Nucl Med Mol Imaging 2010;37:1887-902.CrossRef Bocher M, Blevis IM, Tsukerman L, et al. A fast cardiac gamma camera with dynamic SPECT capabilities: Design, system validation and future potential. Eur J Nucl Med Mol Imaging 2010;37:1887-902.CrossRef
10.
go back to reference Songy B, Lussato D, Guernou M, et al. Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium–zinc–telluride cardiac camera and a conventional SPECT camera. Clin Nucl Med 2011;36:776-80.CrossRef Songy B, Lussato D, Guernou M, et al. Comparison of myocardial perfusion imaging using thallium-201 between a new cadmium–zinc–telluride cardiac camera and a conventional SPECT camera. Clin Nucl Med 2011;36:776-80.CrossRef
11.
go back to reference Garcia EV, Faber TL, Esteves FP. Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications. J Nucl Med 2011;52:210-7.CrossRef Garcia EV, Faber TL, Esteves FP. Cardiac dedicated ultrafast SPECT cameras: new designs and clinical implications. J Nucl Med 2011;52:210-7.CrossRef
12.
go back to reference Hesse B, Lindhardt TB, Acampa W, et al. EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Mol Imaging 2008;35:851-85.CrossRef Hesse B, Lindhardt TB, Acampa W, et al. EANM/ESC guidelines for radionuclide imaging of cardiac function. Eur J Nucl Mol Imaging 2008;35:851-85.CrossRef
13.
go back to reference Akincioglu C, Berman DS, Nishina H, et al. Assessment of diastolic function using 16-Frame 99m Tc-Sestamibi gated myocardial perfusion SPECT: normal values. J Nucl Med 2005;46:1102-9.PubMed Akincioglu C, Berman DS, Nishina H, et al. Assessment of diastolic function using 16-Frame 99m Tc-Sestamibi gated myocardial perfusion SPECT: normal values. J Nucl Med 2005;46:1102-9.PubMed
14.
go back to reference Nagueh SF, Appleton CP, Gillebert TC, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography. Eur J Echocardiogr 2009;10:165-93.CrossRef Nagueh SF, Appleton CP, Gillebert TC, et al. Recommendations for the evaluation of left ventricular diastolic function by echocardiography. Eur J Echocardiogr 2009;10:165-93.CrossRef
15.
go back to reference Martin Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;327:307-10.CrossRef Martin Bland J, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986;327:307-10.CrossRef
16.
go back to reference Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.CrossRef Bland JM, Altman DG. Measuring agreement in method comparison studies. Stat Methods Med Res 1999;8:135-60.CrossRef
17.
go back to reference Cochet A, Quilichini G, Dygai-Cochet I, et al. Baseline diastolic dysfunction as a predictive factor of trastuzumab-mediated cardiotoxicity after adjuvant anthracycline therapy in breast cancer. Breast Cancer Res Treat 2011;130:845-54.CrossRef Cochet A, Quilichini G, Dygai-Cochet I, et al. Baseline diastolic dysfunction as a predictive factor of trastuzumab-mediated cardiotoxicity after adjuvant anthracycline therapy in breast cancer. Breast Cancer Res Treat 2011;130:845-54.CrossRef
18.
go back to reference Reuvekamp EJ, Bulten BF, Nieuwenhuis AA, et al. Does diastolic dysfunction precede systolic dysfunction in trastuzumab-induced cardiotoxicity? Assessment with multigated radionuclide angiography (MUGA). J Nucl Cardiol 2016;23:824-32.CrossRef Reuvekamp EJ, Bulten BF, Nieuwenhuis AA, et al. Does diastolic dysfunction precede systolic dysfunction in trastuzumab-induced cardiotoxicity? Assessment with multigated radionuclide angiography (MUGA). J Nucl Cardiol 2016;23:824-32.CrossRef
19.
go back to reference Nichols KJ, van Tosh A, De Bondt P, et al. Normal limits of gated blood pool SPECT count-based regional cardiac function parameters. Int J Cardiovasc Imaging 2008;24:717-25.CrossRef Nichols KJ, van Tosh A, De Bondt P, et al. Normal limits of gated blood pool SPECT count-based regional cardiac function parameters. Int J Cardiovasc Imaging 2008;24:717-25.CrossRef
20.
go back to reference Dores H, Abecasis J, Correia MJ et al (2013) Detection of early sub-clinical trastuzumab-induced cardiotoxicity in breast cancer patients. Arq Bras Cardiol 100:328–332PubMed Dores H, Abecasis J, Correia MJ et al (2013) Detection of early sub-clinical trastuzumab-induced cardiotoxicity in breast cancer patients. Arq Bras Cardiol 100:328–332PubMed
21.
go back to reference Appel JM, Jensen BV, Nielsen DL, et al. Systolic versus diastolic cardiac function variables during epirubicin treatment for breast cancer. Int J Cardiovasc Imaging 2010;26:217-23.CrossRef Appel JM, Jensen BV, Nielsen DL, et al. Systolic versus diastolic cardiac function variables during epirubicin treatment for breast cancer. Int J Cardiovasc Imaging 2010;26:217-23.CrossRef
22.
go back to reference Zavadovsky KV, Krivonogov NG, Lishmanov YB. The usefulness of gated blood pool scintigraphy for right ventricular function evaluation in pulmonary embolism patients. Ann Nucl Med 2014;28:632-7.CrossRef Zavadovsky KV, Krivonogov NG, Lishmanov YB. The usefulness of gated blood pool scintigraphy for right ventricular function evaluation in pulmonary embolism patients. Ann Nucl Med 2014;28:632-7.CrossRef
23.
go back to reference Iskandrian AS, Hakki AH. Age-related changes in left ventricular diastolic performance. Am Heart J 1986;112:75-8.CrossRef Iskandrian AS, Hakki AH. Age-related changes in left ventricular diastolic performance. Am Heart J 1986;112:75-8.CrossRef
24.
go back to reference Lee KJ, Southee AE, Bautovich GJ, et al. Normalised radionuclide measures of left ventricular diastolic function. Eur J Nucl Med 1989;15:1237.CrossRef Lee KJ, Southee AE, Bautovich GJ, et al. Normalised radionuclide measures of left ventricular diastolic function. Eur J Nucl Med 1989;15:1237.CrossRef
25.
go back to reference Muntinga HJ, Van den Berg F, Knol HR, et al. Normal values and reproducibility of left ventricular filling parameters by radionuclide angiography. Int J Card Imaging 1997;13:165-71.CrossRef Muntinga HJ, Van den Berg F, Knol HR, et al. Normal values and reproducibility of left ventricular filling parameters by radionuclide angiography. Int J Card Imaging 1997;13:165-71.CrossRef
26.
go back to reference Miller TR, Grossman SJ, Schectman KB, et al. Left ventricular diastolic filling and its association with age. Am J Cardiol 1986;58:531-5.CrossRef Miller TR, Grossman SJ, Schectman KB, et al. Left ventricular diastolic filling and its association with age. Am J Cardiol 1986;58:531-5.CrossRef
27.
go back to reference Prasad A, Popovic ZB, Arbab-Zadeh A, et al. The effects of aging and physical activity on Doppler measures of diastolic function. Am J Cardiol 2007;99:1629-36.CrossRef Prasad A, Popovic ZB, Arbab-Zadeh A, et al. The effects of aging and physical activity on Doppler measures of diastolic function. Am J Cardiol 2007;99:1629-36.CrossRef
28.
go back to reference Ryu DR. Normal reference values for Doppler echocardiography : Influences of ageing, gender and ethnicity. J Cardiovasc Ultrasound 2016;24:112-4.CrossRef Ryu DR. Normal reference values for Doppler echocardiography : Influences of ageing, gender and ethnicity. J Cardiovasc Ultrasound 2016;24:112-4.CrossRef
29.
go back to reference Maceira AM, Prasad SK, Khan M, Pennell DJ. Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J 2006;27:2879-88.CrossRef Maceira AM, Prasad SK, Khan M, Pennell DJ. Reference right ventricular systolic and diastolic function normalized to age, gender and body surface area from steady-state free precession cardiovascular magnetic resonance. Eur Heart J 2006;27:2879-88.CrossRef
30.
go back to reference Maceira AM, Prasad SK, Khan M, Pennell DJ. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2006;8:417-26.CrossRef Maceira AM, Prasad SK, Khan M, Pennell DJ. Normalized left ventricular systolic and diastolic function by steady state free precession cardiovascular magnetic resonance. J Cardiovasc Magn Reson 2006;8:417-26.CrossRef
31.
go back to reference Wan SH, Vogel MW, Chen HH. Pre-clinical diastolic dysfunction. J Am Coll Cardiol 2014;63:407-16.CrossRef Wan SH, Vogel MW, Chen HH. Pre-clinical diastolic dysfunction. J Am Coll Cardiol 2014;63:407-16.CrossRef
32.
go back to reference Fleg JL, Strait J. Age-associated changes in cardiovascular structure and function: A fertile milieu for future disease. Heart Fail Rev 2012;17:545-54.CrossRef Fleg JL, Strait J. Age-associated changes in cardiovascular structure and function: A fertile milieu for future disease. Heart Fail Rev 2012;17:545-54.CrossRef
33.
go back to reference Dai D-F, Chen T, Johnson SC, et al. Cardiac aging: From molecular mechanisms to significance in human health and disease. Antioxid Redox Signal 2012;16:1492-526.CrossRef Dai D-F, Chen T, Johnson SC, et al. Cardiac aging: From molecular mechanisms to significance in human health and disease. Antioxid Redox Signal 2012;16:1492-526.CrossRef
34.
go back to reference Haarmark C, Haase C, Jensen MM, Zerahn B. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera. J Nucl Cardiol 2016;23:87-97.CrossRef Haarmark C, Haase C, Jensen MM, Zerahn B. Pre-chemotherapy values for left and right ventricular volumes and ejection fraction by gated tomographic radionuclide angiography using a cadmium-zinc-telluride detector gamma camera. J Nucl Cardiol 2016;23:87-97.CrossRef
Metadata
Title
Ventricular peak emptying and filling rates measured by gated tomographic radionuclide angiography using a cadmium–zinc–telluride SPECT camera in chemotherapy-naïve cancer patients
Authors
Naja Liv Hansen, MD, PhD
Christian Haarmark, MD, PhD
Bo Zerahn, MD
Publication date
01-08-2020
Publisher
Springer International Publishing
Published in
Journal of Nuclear Cardiology / Issue 4/2020
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-019-01756-2

Other articles of this Issue 4/2020

Journal of Nuclear Cardiology 4/2020 Go to the issue