Skip to main content
Top
Published in: Journal of Nuclear Cardiology 3/2014

01-06-2014 | Original Article

Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border

Authors: Omosalewa O. Lalude, MBBS, FACC, Mell F. Gutarra, MD, Eduardo N. Pollono, MD, Soyoung Lee, MSCS, Patrick M. Tarwater, PhD

Published in: Journal of Nuclear Cardiology | Issue 3/2014

Login to get access

Abstract

Background

The American College of Cardiology/American Society of Nuclear Cardiology published revised appropriate use criteria (AUC) for SPECT MPI in 2009. We assessed adherence to these guidelines and factors associated with inappropriate utilization at the University Medical Center.

Methods

The AUC was applied retrospectively to 420 SPECT MPI studies. Two-sample t test, Fisher’s exact test, and multivariable logistic regression models were used for analysis.

Results

There were 322 appropriate (86%) and 54 (14%) inappropriate studies. The odds of having an inappropriate test increased with younger age (P < .001) and female gender (P < .001). Subjects with diabetes (P = .007) and chest pain (P < .001) were less likely to have an inappropriate test. Academic outpatients were three times more likely to have an inappropriate study (P = .123), while community PCPs were 5.6 times (P = .011) and community cardiologists eight times more likely to order inappropriate tests (P = .031).

Conclusions

Inappropriate SPECT MPI in low risk younger women is an important issue on the USA-Mexico border. Initiatives to reduce inappropriate SPECT MPI should focus on a few indications and evaluation of cardiovascular symptoms in younger age women in outpatient/community practices.
Literature
1.
go back to reference Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.PubMedCrossRef Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.PubMedCrossRef
2.
go back to reference Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef
3.
go back to reference Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef
4.
go back to reference Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.PubMedCrossRef Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.PubMedCrossRef
5.
go back to reference Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef
6.
go back to reference Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation appropriate use criteria task force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.PubMedCrossRef Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation appropriate use criteria task force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. J Am Coll Cardiol 2009;53:2201-29.PubMedCrossRef
7.
go back to reference Gibbons RJ, Askew WJ, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.PubMedCrossRef Gibbons RJ, Askew WJ, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.PubMedCrossRef
8.
go back to reference Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.PubMedCrossRef Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.PubMedCrossRef
9.
go back to reference Carryer DJ, Askew JW, Hodge D, Miller TD, Gibbons RJ. The impact of ordering provider specialty on appropriateness classification. J Nucl Cardiol 2012;19:285-90.PubMedCrossRef Carryer DJ, Askew JW, Hodge D, Miller TD, Gibbons RJ. The impact of ordering provider specialty on appropriateness classification. J Nucl Cardiol 2012;19:285-90.PubMedCrossRef
10.
go back to reference Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian Tertiary Cardiac Center. J Nucl Cardiol 2011;18:324-30.PubMedCrossRef Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian Tertiary Cardiac Center. J Nucl Cardiol 2011;18:324-30.PubMedCrossRef
12.
13.
go back to reference Iglehart JK. Health insurers and medical-imaging policy—A work in progress. N Engl J Med 2009;360:1030-7.PubMedCrossRef Iglehart JK. Health insurers and medical-imaging policy—A work in progress. N Engl J Med 2009;360:1030-7.PubMedCrossRef
14.
go back to reference Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.PubMedCrossRef Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.PubMedCrossRef
15.
go back to reference Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-15.PubMedCrossRef Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-15.PubMedCrossRef
16.
go back to reference Saifi S, Taylor AJ, Allen J, Hendel R. The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging. J Am Coll Cardiol Imaging 2013;6:823-9.CrossRef Saifi S, Taylor AJ, Allen J, Hendel R. The use of a learning community and online evaluation of utilization for SPECT myocardial perfusion imaging. J Am Coll Cardiol Imaging 2013;6:823-9.CrossRef
Metadata
Title
Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border
Authors
Omosalewa O. Lalude, MBBS, FACC
Mell F. Gutarra, MD
Eduardo N. Pollono, MD
Soyoung Lee, MSCS
Patrick M. Tarwater, PhD
Publication date
01-06-2014
Publisher
Springer US
Published in
Journal of Nuclear Cardiology / Issue 3/2014
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-014-9881-9

Other articles of this Issue 3/2014

Journal of Nuclear Cardiology 3/2014 Go to the issue

Editor's Page

Do We Need PET?