Skip to main content
Top
Published in: Journal of Nuclear Cardiology 4/2011

01-08-2011 | Original Article

Incremental prognostic value of coronary flow reserve assessed with single-photon emission computed tomography

Authors: Stefania Daniele, PhD, Carmela Nappi, MD, Wanda Acampa, MD, PhD, Giovanni Storto, MD, PhD, Teresa Pellegrino, MD, PhD, Francesca Ricci, MD, Evgjeni Xhoxhi, MD, Francesco Porcaro, MD, Mario Petretta, MD, Alberto Cuocolo, MD

Published in: Journal of Nuclear Cardiology | Issue 4/2011

Login to get access

Abstract

Background

We assessed the prognostic value of coronary flow reserve (CFR) estimated by single-photon emission computed tomography (SPECT) in patients with suspected myocardial ischemia.

Methods and Results

Myocardial perfusion and CFR were assessed in 106 patients using dipyridamole/rest Tc-99m sestamibi SPECT and follow-up was obtained in 103 (97%) patients. Four early revascularized patients were excluded and 99 were assigned to normal (summed stress score <3) vs abnormal myocardial perfusion and to normal (≥2.0) vs abnormal CFR. During the follow-up (5.8 ± 2.1 years), 28 patients experienced a cardiac event (cardiac death, nonfatal myocardial infarction, and late revascularization). Abnormal perfusion (P < .01) and abnormal CFR (P < .05) were independent predictors of cardiac events at Cox proportional hazard regression analysis. Also in patients with normal perfusion, abnormal CFR was associated with a higher annual event rate compared with normal CFR (5.2% vs 0.7%; P < .05). CFR data improved the prognostic power of the model including clinical and myocardial perfusion data increasing the global chi-square from 18.6 to 22.8 (P < .05). Finally, at parametric survival analysis, in patients with normal perfusion the time to achieve ≥2% risk of events was >60 months in those with normal and <12 months in those with abnormal CFR.

Conclusions

Myocardial perfusion findings and CFR at SPECT imaging are both independent predictors of cardiac events. Estimated CFR provides incremental prognostic information over those obtained from clinical and myocardial perfusion data, particularly in patients with normal perfusion findings.
Literature
1.
go back to reference Cuocolo A, Petretta M, Acampa W, De Falco T. Gated SPECT myocardial perfusion imaging: The further improvements of an excellent tool. Q J Nucl Med Mol Imaging 2010;54:129-44.PubMed Cuocolo A, Petretta M, Acampa W, De Falco T. Gated SPECT myocardial perfusion imaging: The further improvements of an excellent tool. Q J Nucl Med Mol Imaging 2010;54:129-44.PubMed
2.
go back to reference Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al.; American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American Society of Nuclear Cardiology, American Heart Association. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al.; American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group, American Society of Nuclear Cardiology, American Heart Association. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.PubMedCrossRef
3.
go back to reference Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed Hachamovitch R, Berman DS, Shaw LJ, Kiat H, Cohen I, Cabico JA, et al. Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death: Differential stratification for risk of cardiac death and myocardial infarction. Circulation 1998;97:535-43.PubMed
4.
go back to reference Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol 2004;43:200-8.PubMedCrossRef Hachamovitch R, Hayes SW, Friedman JD, Cohen I, Berman DS. Stress myocardial perfusion single-photon emission computed tomography is clinically effective and cost effective in risk stratification of patients with a high likelihood of coronary artery disease (CAD) but no known CAD. J Am Coll Cardiol 2004;43:200-8.PubMedCrossRef
5.
go back to reference Brunken RC. Challenges for measurement of myocardial perfusion and perfusion reserve by SPECT imaging. J Nucl Cardiol 2007;14:145-9.PubMedCrossRef Brunken RC. Challenges for measurement of myocardial perfusion and perfusion reserve by SPECT imaging. J Nucl Cardiol 2007;14:145-9.PubMedCrossRef
6.
go back to reference Ragosta M. The clinical assessment of coronary flow reserve in patients with coronary artery disease. J Nucl Cardiol 2004;11:651-5.PubMedCrossRef Ragosta M. The clinical assessment of coronary flow reserve in patients with coronary artery disease. J Nucl Cardiol 2004;11:651-5.PubMedCrossRef
7.
go back to reference Sugihara H, Yonekura Y, Kataoka K, Fukai D, Kitamura N, Taniguchi Y. Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin. J Nucl Cardiol 2001;8:575-9.PubMedCrossRef Sugihara H, Yonekura Y, Kataoka K, Fukai D, Kitamura N, Taniguchi Y. Estimation of coronary flow reserve with the use of dynamic planar and SPECT images of Tc-99m tetrofosmin. J Nucl Cardiol 2001;8:575-9.PubMedCrossRef
8.
go back to reference Taki J, Fujino S, Nakajima K, Matsunari I, Okazaki H, Saga T, et al. Tc-99m sestamibi retention characteristics during pharmacological hyperemia in human myocardium: Comparison with coronary flow reserve measured by Doppler flowire. J Nucl Med 2001;42:1457-63.PubMed Taki J, Fujino S, Nakajima K, Matsunari I, Okazaki H, Saga T, et al. Tc-99m sestamibi retention characteristics during pharmacological hyperemia in human myocardium: Comparison with coronary flow reserve measured by Doppler flowire. J Nucl Med 2001;42:1457-63.PubMed
9.
go back to reference Ito Y, Katoh C, Noriyasu K, Kuge Y, Furuyama H, Morita K, et al. Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: Comparison with the results of O-15 H2O PET. Eur J Nucl Med Mol Imaging 2003;30:281-7.PubMedCrossRef Ito Y, Katoh C, Noriyasu K, Kuge Y, Furuyama H, Morita K, et al. Estimation of myocardial blood flow and myocardial flow reserve by 99mTc-sestamibi imaging: Comparison with the results of O-15 H2O PET. Eur J Nucl Med Mol Imaging 2003;30:281-7.PubMedCrossRef
10.
go back to reference Storto G, Cirillo P, Vicario ML, Pellegrino T, Sorrentino AR, Petretta M, et al. Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique. J Nucl Cardiol 2004;11:682-8.PubMedCrossRef Storto G, Cirillo P, Vicario ML, Pellegrino T, Sorrentino AR, Petretta M, et al. Estimation of coronary flow reserve by Tc-99m sestamibi imaging in patients with coronary artery disease: Comparison with the results of intracoronary Doppler technique. J Nucl Cardiol 2004;11:682-8.PubMedCrossRef
11.
go back to reference Petretta M, Soricelli A, Storto G, Cuocolo A. Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers. J Nucl Cardiol 2008;15:456-65.PubMedCrossRef Petretta M, Soricelli A, Storto G, Cuocolo A. Assessment of coronary flow reserve using single photon emission computed tomography with technetium 99m-labeled tracers. J Nucl Cardiol 2008;15:456-65.PubMedCrossRef
12.
go back to reference Storto G, Pellegrino T, Sorrentino AR, Luongo L, Petretta M, Cuocolo A. Estimation of coronary flow reserve by sestamibi imaging in type 2 diabetic patients with normal coronary arteries. J Nucl Cardiol 2007;14:194-9.PubMedCrossRef Storto G, Pellegrino T, Sorrentino AR, Luongo L, Petretta M, Cuocolo A. Estimation of coronary flow reserve by sestamibi imaging in type 2 diabetic patients with normal coronary arteries. J Nucl Cardiol 2007;14:194-9.PubMedCrossRef
13.
go back to reference Storto G, Soricelli A, Pellegrino T, Petretta M, Cuocolo A. Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: Comparison of two different approaches. Eur J Nucl Med Mol Imaging 2009;36:2034-41.PubMedCrossRef Storto G, Soricelli A, Pellegrino T, Petretta M, Cuocolo A. Assessment of the arterial input function for estimation of coronary flow reserve by single photon emission computed tomography: Comparison of two different approaches. Eur J Nucl Med Mol Imaging 2009;36:2034-41.PubMedCrossRef
14.
go back to reference Pellegrino T, Storto G, Filardi PP, Sorrentino AR, Silvestro A, Petretta M, et al. Relationship between brachial artery flow-mediated dilation and coronary flow reserve in patients with peripheral artery disease. J Nucl Med 2005;46:1997-2002.PubMed Pellegrino T, Storto G, Filardi PP, Sorrentino AR, Silvestro A, Petretta M, et al. Relationship between brachial artery flow-mediated dilation and coronary flow reserve in patients with peripheral artery disease. J Nucl Med 2005;46:1997-2002.PubMed
15.
go back to reference Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.PubMedCrossRef Hansen CL, Goldstein RA, Akinboboye OO, Berman DS, Botvinick EH, Churchwell KB, et al. American Society of Nuclear Cardiology. Myocardial perfusion and function: Single photon emission computed tomography. J Nucl Cardiol 2007;14:e39-60.PubMedCrossRef
16.
go back to reference Acampa W, Petretta M, Evangelista L, Nappi G, Luongo L, Petretta MP, et al. Stress cardiac single-photon emission computed tomographic imaging late after coronary artery bypass surgery for risk stratification and estimation of time to cardiac events. J Thorac Cardiovasc Surg 2008;136:46-51.PubMedCrossRef Acampa W, Petretta M, Evangelista L, Nappi G, Luongo L, Petretta MP, et al. Stress cardiac single-photon emission computed tomographic imaging late after coronary artery bypass surgery for risk stratification and estimation of time to cardiac events. J Thorac Cardiovasc Surg 2008;136:46-51.PubMedCrossRef
17.
go back to reference Thygesen K, Alpert JS, White HD. Universal definition of myocardial infarction. J Am Coll Cardiol 2007;50:2173-95.PubMedCrossRef Thygesen K, Alpert JS, White HD. Universal definition of myocardial infarction. J Am Coll Cardiol 2007;50:2173-95.PubMedCrossRef
18.
go back to reference Lawless J. Statistical models and methods for lifetime data. New York, NY: John Wiley and Sons; 1982. Lawless J. Statistical models and methods for lifetime data. New York, NY: John Wiley and Sons; 1982.
19.
go back to reference Harrell FE Jr. Predicting outcomes: Applied survival analysis and logistic regression. Charlottesville, VA: University of Virginia; 2000. Harrell FE Jr. Predicting outcomes: Applied survival analysis and logistic regression. Charlottesville, VA: University of Virginia; 2000.
20.
go back to reference Bergmann SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.PubMedCrossRef Bergmann SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial blood flow in human subjects with oxygen-15-labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.PubMedCrossRef
21.
go back to reference Araujo LI, Lammertsma AA, Rhodes CG, McFalls EO, Iida H, Rechavia E, et al. Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography. Circulation 1991;83:875-85.PubMed Araujo LI, Lammertsma AA, Rhodes CG, McFalls EO, Iida H, Rechavia E, et al. Noninvasive quantification of regional myocardial blood flow in coronary artery disease with oxygen-15-labeled carbon dioxide inhalation and positron emission tomography. Circulation 1991;83:875-85.PubMed
22.
go back to reference Masuda D, Nohara R, Tamaki N, Hosokawa R, Inada H, Hikai T, et al. Evaluation of coronary blood flow reserve by 13N-NH3 positron emission computed tomography (PET) with dipyridamole in the treatment of hypertension with the ACE inhibitor (Cilazapril). Ann Nucl Med 2000;14:353-60.PubMedCrossRef Masuda D, Nohara R, Tamaki N, Hosokawa R, Inada H, Hikai T, et al. Evaluation of coronary blood flow reserve by 13N-NH3 positron emission computed tomography (PET) with dipyridamole in the treatment of hypertension with the ACE inhibitor (Cilazapril). Ann Nucl Med 2000;14:353-60.PubMedCrossRef
23.
go back to reference Herzog BA, Husmann L, Valenta I, Gaemperli O, Siegrist PT, Tay FM, et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol 2009;54:150-6.PubMedCrossRef Herzog BA, Husmann L, Valenta I, Gaemperli O, Siegrist PT, Tay FM, et al. Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol 2009;54:150-6.PubMedCrossRef
24.
go back to reference Hachamovitch R, Hayes S, Friedman JD, Cohen I, Shaw LJ, Germano G, et al. Determinants of risk and its temporal variation in patients with normal stress myocardial perfusion scans: What is the warranty period of a normal scan? J Am Coll Cardiol 2003;41:1329-40.PubMedCrossRef Hachamovitch R, Hayes S, Friedman JD, Cohen I, Shaw LJ, Germano G, et al. Determinants of risk and its temporal variation in patients with normal stress myocardial perfusion scans: What is the warranty period of a normal scan? J Am Coll Cardiol 2003;41:1329-40.PubMedCrossRef
25.
go back to reference Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin 2009;27:227-36.PubMedCrossRef Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin 2009;27:227-36.PubMedCrossRef
26.
go back to reference Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.PubMedCrossRef Slomka PJ, Patton JA, Berman DS, Germano G. Advances in technical aspects of myocardial perfusion SPECT imaging. J Nucl Cardiol 2009;16:255-76.PubMedCrossRef
Metadata
Title
Incremental prognostic value of coronary flow reserve assessed with single-photon emission computed tomography
Authors
Stefania Daniele, PhD
Carmela Nappi, MD
Wanda Acampa, MD, PhD
Giovanni Storto, MD, PhD
Teresa Pellegrino, MD, PhD
Francesca Ricci, MD
Evgjeni Xhoxhi, MD
Francesco Porcaro, MD
Mario Petretta, MD
Alberto Cuocolo, MD
Publication date
01-08-2011
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue 4/2011
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-011-9345-4

Other articles of this Issue 4/2011

Journal of Nuclear Cardiology 4/2011 Go to the issue